Aims. The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems. Methods. A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies based on registry data were analyzed separately. Results. The review included nine studies which covered a total of 2,190 short stems. The mean follow-up was 6.4 years (2 to 12) with an all-cause survival of 95.4%. When revisions due to
Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m. 2. , and 59% were female. An uncemented metaphyseal fixation stem was used in 30%, an uncemented diaphyseal fixation stem in 28%, an uncemented modular body stem with metaphyseal fixation sleeve in 24%, and a cemented stem in 18%. Simultaneous corrective femoral osteotomy was performed in 18%. Kaplan-Meier survivorships and Harris hip scores were reported. Mean follow-up was 8 years. The 10-year survivorships free of femoral loosening, aseptic femoral revision, any revision, and any reoperation were 95%, 93%, 90% and 88%, respectively. Revisions occurred in 13 hips for: aseptic femoral component loosening (3), stem fracture (2), dislocation (2),
Chronic pelvic discontinuity (CPD) during revision hip arthroplasty is a challenging entity to address. The aim of this study was to evaluate the clinical and radiologic outcomes, and complications of the “acetabular distraction technique” for the management of CPD during revision hip arthroplasty. Patients with CPD, who underwent acetabular revision between 2014 and 2022 at two tertiary care centres, using an identical distraction technique, were evaluated. Demographic parameters, pre-operative acetabular bone loss, duration of follow-up, clinical and radiologic outcomes, and survivorship were evaluated. In all, 46 patients with a mean follow-up of 34.4 (SD=19.6, range: 24–120) months were available for evaluation. There were 25 (54.3%) male, and 21 (45.7%) female patients, with a mean age of 58.1 (SD=10.5, range: 40–81) years at the time of revision surgery. Based on the Paprosky classification of acetabular bone loss, 19 (41.3%), 12 (26.1%), and 15 (32.6%) patients had type 3b, 3a, and 2c defects. All patients were managed using the Trabecular Metal™ Acetabular Revision System; 16 patients required additional Trabecular Metal™ augments. The mean HHS improved from 50.1 (SD=7.6, range: 34.3 – 59.8) pre-operatively, to 86.6 (SD=4.2, range: 74.8 -91.8) at the last follow-up. Two patients (4.3 %) developed partial sciatic nerve palsy, two (4.3%) had posterior dislocation, and one (2.2%) required re-revision for aseptic loosening. Radiologically, 36 (78.3%) patients showed healing of the pelvic discontinuity. The Kaplan-Meier construct survivorship was 97.78% when using re-revision for
There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75).Aims
Methods
The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification.Aims
Methods
The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA). We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail.Aims
Methods
The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups. Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively.Aims
Methods
THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for implantation were revisions for aseptic loosening of the cup (n=45), aseptic loosening of the femoral stem (n=3), bipolar loosening (n=11), septic loosening (n=10), periprosthetic fracture (n=5), chronic dislocation (n=4), intraprosthetic dislocation (n=2), cup impingement (n=1), primary posttraumatic arthroplasty (n=8), and acetabular dysplasia (n=4). The jumbo cups used were COPTOS TH (SERF), which combines press-fit fixation with supplemental fixation (acetabular hook, two superior flanges with one to four screws, two acetabular pegs). A bone graft was added in 74 cases (80%). The clinical assessment consisted of the Harris hip score. The primary endpoint was surgical revision for
Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; SERF, DÉCINES-CHARPIEU, FRANCE) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of
The benefit of using acetabular screws in primary total hip arthroplasty (THA) has been questioned in recent years. The disadvantages of using screws include increased operative time, risk of injury to surrounding neurovascular structures and metal ware breakage. Recent large registry studies have reported that screws do not confer a protective effect against acetabular loosening or the presence of osteolysis. Other studies have even described an increased risk of
The decision to undertake total hip replacement (THA) in a child is complex and daunting. This is augmented by the paucity of data on potential quality of life (QoL) improvement and functional outcomes. Therefore, the aim of this study was to ascertain whether outcomes after surgery are influenced by the nature of the primary diagnosis. This was a prospective, consecutive cohort study of patients under the age of 18 years undergoing THA by a single arthroplasty surgeon in collaboration with colleagues at a regional paediatric hospital. Patient electronic notes, radiographs and PROMS (EQ5D-Y, Oxford Hip Score (OHS) and modified Harris Hip Score(mHHS)) were reviewed. Twenty-two THAs were performed in patients less than 18 years (median 15 (range 10.7–17.9), with 7 patients undergoing bilateral surgery. Mean follow-up was 2 years. Thirteen of the THAs were undertaken for systemic conditions effecting multiple joints (Mucopolysaccharidoses, Mucolipidosis and Scwachman-Diamond syndrome) with the hip the worst affected joint and 9 for single joint disease (AVN, Perthes, dysplasia and idiopathic chondrolysis). PROMS scores showed reliable improvements with no differences between the two groups. Health related QoL was calculated from EQ5D-Y and indicated an overall improvement of 1.06(0.879–1.25). 6 patients were wheelchair users preop. All patients were independent walkers at follow-up. One patient underwent successful revision surgery for
The aim of this study was to determine the outcome of all primary total hip arthroplasties (THAs) and their subsequent revision procedures in patients aged under 50 years performed at our institution. All 1,049 primary THAs which were undertaken in 860 patients aged under 50 years between 1988 and 2018 in our tertiary care institution were included. We used cemented implants in both primary and revision surgery. Impaction bone grafting was used in patients with acetabular or femoral bone defects. Kaplan-Meier analyses were used to determine the survival of primary and revision THA with the endpoint of revision for any reason, and of revision for aseptic loosening.Aims
Methods
Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA.Aims
Methods
Aims. We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods. We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results. The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the
Aims. Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. Methods. Using the database of
a single academic centre, 126 revision THAs in 117 patients using a single
design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for
Aims. Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA. Methods. This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m. 2. , and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported. Results. A total of 43 patients were enrolled. At minimum follow-up of five years, 23 (53.4%) returned for clinical and radiological review, 25 (58.1%) had metal ion analysis performed, 19 (44.2%) underwent dual energy x-ray absorptiometry scans, and 25 (58%) completed a pain-drawing questionnaire. The mean modified Harris Hip Scores improved significantly from 54.8 (SD 19) preoperatively to 93.08 (SD 10.5) five years postoperatively (p < 0.001). One patient was revised for
Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation.Aims
Methods
Introduction. Patients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of
Background. Reduced dislocation rates using lipped polyethylene (PE) liners in modular uncemented acetabular components has been shown, yet there may be increased wear because of impingement, which may lead to aseptic loosening. We used New Zealand Joint Registry (NZJR) data to compare survival rates, revision rates for dislocation and aseptic loosening between lipped and neutral liners. Methods. 31,247 primary THAs using the four commonly used uncemented modular cups were identified (January 1, 1999 to December 31, 2018). The lipped liner group comprised 49% males vs 42% in the neutral group (p < 0.001); 96% had OA vs 95% in the neutral group (p < 0.001). There was no difference in other patient characteristics. Mean follow-up was 5.1 years (SD 3.9); longest follow-up 19.3 years. Kaplan Meier survival rates were compared (20,240 lipped and 11,007 neutral PE liners). Highly cross-linked PE was used in 99% of lipped liner cups vs 85% of neutral liner cups. Associated hazard ratios were calculated using a Cox regression analysis. Results. KM survival at 10 years for lipped PE liners was 96% for lipped (95%CI 95.4%-96.2%) and 95% for neutral liners (95%CI 94.7%-95.9%). Controlling for age, gender approach, head size, image guidance, the all-cause revision risk was greater for neutral liner (HR 1.17 [95% CI 1.06 to 1.36]; p = 0.032). There was a higher risk of revision for dislocation in those with neutral liners (HR 1.84 [95%CI 1.41–2.41]; p < 0.001) but no difference in the revision rate for
Introduction. Many surgeons are reluctant to use a constrained liner at the time of acetabular component revision given concerns this might result in early acetabular component loosening. We hypothesized that with appropriate initial implant stabilization of highly porous acetabular components with supplemental screw fixation, constrained liners could be safely used at the time of acetabular revision. Methods. We retrospectively identified 148 revision total hip arthroplasties (THAs) where a constrained liner of one design was cemented into a newly placed highly porous acetabular component fixed with supplemental screws (mean 5 screws). Mean age at revision THA was 69 years, with 68% being female. The most common indications for revision were two-stage re-implantation (33%), recurrent dislocation (30%), and