Advertisement for orthosearch.org.uk
Results 1 - 20 of 60
Results per page:
Bone & Joint 360
Vol. 12, Issue 5 | Pages 30 - 34
1 Oct 2023

The October 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after arthroscopic shoulder surgery; Level of pain catastrophizing rehab in subacromial impingement: secondary analyses from a pragmatic randomized controlled trial (the SExSI Trial); Anterosuperior versus deltopectoral approach for primary reverse total shoulder arthroplasty: a study of 3,902 cases from the Dutch National Arthroplasty Registry with a minimum follow-up of five years; Assessment of progression and clinical relevance of stress-shielding around press-fit radial head arthroplasty: a comparative study of two implants; A number of modifiable and non-modifiable factors increase the risk for elbow medial ulnar collateral ligament injury in baseball players: a systematic review


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 27 - 27
1 Dec 2022
Suter T Old J McRae S Woodmass J Marsh J Dubberley J MacDonald PB
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 5 - 5
1 Dec 2022
McRae S Suter T Old J Zhang Y Woodmass J Marsh J Dubberley J MacDonald P
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 29 - 29
1 Dec 2022
Alolabi B Shanthanna H Czuczman M Moisiuk P O'Hare T Khan M Forero M Davis K Moro JK Foster G Thabane L
Full Access

Interscalene brachial plexus block is the standard regional analgesic technique for shoulder surgery. Given its adverse effects, alternative techniques have been explored. Reports suggest that the erector spinae plane block may potentially provide effective analgesia following shoulder surgery. However, its analgesic efficacy for shoulder surgery compared with placebo or local anaesthetic infiltration has never been established. We conducted a randomised controlled trial to compare the analgesic efficacy of pre-operative T2 erector spinae plane block with peri-articular infiltration at the end of surgery. Sixty-two patients undergoing arthroscopic shoulder repair were randomly assigned to receive active erector spinae plane block with saline peri-articular injection (n = 31) or active peri-articular injection with saline erector spinae plane block (n = 31) in a blinded double-dummy design. Primary outcome was resting pain score in recovery. Secondary outcomes included pain scores with movement; opioid use; patient satisfaction; adverse effects in hospital; and outcomes at 24 h and 1 month. There was no difference in pain scores in recovery, with a median difference (95%CI) of 0.6 (-1.9-3.1), p = 0.65. Median postoperative oral morphine equivalent utilisation was significantly higher in the erector spinae plane group (21 mg vs. 12 mg; p = 0.028). Itching was observed in 10% of patients who received erector spinae plane block and there was no difference in the incidence of significant nausea and vomiting. Patient satisfaction scores, and pain scores and opioid use at 24 h were similar. At 1 month, six (peri-articular injection) and eight (erector spinae plane block) patients reported persistent pain. Erector spinae plane block was not superior to peri-articular injection for arthroscopic shoulder surgery


Bone & Joint 360
Vol. 11, Issue 5 | Pages 27 - 30
1 Oct 2022


Bone & Joint 360
Vol. 11, Issue 2 | Pages 31 - 34
1 Apr 2022


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 33 - 33
1 Nov 2021
Hartland A Teoh K Rashid M
Full Access

Introduction and Objective. Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes. Materials and Methods. This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion. Results. Eight RCTs were included in the systematic review and data from 7 of these studies pooled in the meta-analysis. A total of 708 patients were randomized across the studies (406 received TXA, 302 received placebo). Studies included patients undergoing anatomic or reverse total shoulder arthroplasty, open Latarjet surgery, and arthroscopic rotator cuff repair. Pooled analysis demonstrated significant reduction in perioperative bleeding with TXA compared to controls; estimated total blood loss (mean difference [MD], −209.66; 95% CI −389.11 to −30.21; p=0.02), and post-operative blood loss (via drain output) (MD, −84.8ml; 95% CI, −140.04 to −29.56; p=0.003). A mean difference in Visual Analogue Scale (VAS) of 2.93 was noted in favour of TXA (95% CI 0.2 to 5.66; p=0.04). Conclusions. Whilst noting some risk of bias within the studies, TXA was effective in reducing blood loss and pain in shoulder surgery. There may be a benefit of TXA use in both open and arthroscopic shoulder procedures. Larger, low risk of bias, RCTs for specific surgical shoulder procedures are required


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 8 - 8
1 May 2021
Jabbal A Stirling PHC Sharma S
Full Access

The purpose of this study is the evaluate the net promotor score of arthroscopic subacromial decompression and rotator cuff repair.

The Friends and Family Test, a variant of the Net Promoter Score, was adapted for the National Health Service to evaluate overall patient satisfaction and how likely patients are to recommend an intervention. It ranges from −100 to 100. Positive scores indicate good performance.

This study quantifies the scores in 71 patients at 1 year following arthroscopic sub acromial decompression and rotator cuff repair. All of the procedures were performed by 1 consultant shoulder specialist. The patient filled out a shoulder questionnaire pre-operatively, at 6 months and 1 year.

The score was 72 for subacromial decompression (n = 32) and 85 for rotator cuff repair +/− decompression (n = 39). Oxford shoulder score was also taken and had a rise of 4.3 and 6.9 respectively. Our study indicates that these procedures are highly valued and are recommended by patients according to the Friends and Family Test. The results of the Friends and Family Test correlated well with postoperative functional improvement and satisfaction.

We conclude from this study that a compound score based on the Friends and Family Test is a useful addition to traditional measures of patient satisfaction.


Bone & Joint 360
Vol. 9, Issue 3 | Pages 8 - 9
1 Jun 2020


Bone & Joint 360
Vol. 9, Issue 3 | Pages 26 - 29
1 Jun 2020


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1479 - 1488
1 Dec 2019
Laverdière C Corban J Khoury J Ge SM Schupbach J Harvey EJ Reindl R Martineau PA

Aims

Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics.

Materials and Methods

A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 26 - 29
1 Dec 2019


Bone & Joint 360
Vol. 8, Issue 4 | Pages 22 - 23
1 Aug 2019


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 860 - 866
1 Jul 2019
Nicholson JA Searle HKC MacDonald D McBirnie J

Aims

The aim of this study was to investigate the influence of age on the cost-effectiveness of arthroscopic rotator cuff repair.

Patients and Methods

A total of 112 patients were prospectively monitored for two years after arthroscopic rotator cuff repair using the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH), the Oxford Shoulder Score (OSS), and the EuroQol five-dimension questionnaire (EQ-5D). Complications and use of healthcare resources were recorded. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). Propensity score-matching was used to compare those aged below and above 65 years of age. Satisfaction was determined using the Net Promoter Score (NPS). Linear regression was used to identify variables that influenced the outcome at two years postoperatively.


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives. Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Methods. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio). Results. ICG fluorescence angiography allowed for visualization of blood flow in the rotator cuff in all groups. The adhesive capsulitis group showed significantly earlier enhancement than the other groups. Furthermore, the adhesive capsulitis group had a significantly smaller hypovascular area ratio than the other groups. Conclusion. ICG fluorescence angiography allowed for evaluation of real-time blood flow of the rotator cuff in arthroscopic shoulder surgery. The techniques of ICG fluorescence angiography are simple and easy to observe, observer reliability is high, and it has utility for evaluating blood flow during surgery. Cite this article: N. Doi, T. Izaki, S. Miyake, T. Shibata, T. Ishimatsu, Y. Shibata, T. Yamamoto. Intraoperative evaluation of blood flow for soft tissues in orthopaedic surgery using indocyanine green fluorescence angiography: A pilot study. Bone Joint Res 2019;8:118–125. DOI: 10.1302/2046-3758.83.BJR-2018-0151.R1


Bone & Joint Research
Vol. 8, Issue 1 | Pages 3 - 10
1 Jan 2019
Hernandez P Sager B Fa A Liang T Lozano C Khazzam M

Objectives

The purpose of this study was to examine the bactericidal efficacy of hydrogen peroxide (H2O2) on Cutibacterium acnes (C. acnes). We hypothesize that H2O2 reduces the bacterial burden of C. acnes.

Methods

The effect of H2O2 was assessed by testing bactericidal effect, time course analysis, growth inhibition, and minimum bactericidal concentration. To assess the bactericidal effect, bacteria were treated for 30 minutes with 0%, 1%, 3%, 4%, 6%, 8%, or 10% H2O2 in saline or water and compared with 3% topical H2O2 solution. For time course analysis, bacteria were treated with water or saline (controls), 3% H2O2 in water, 3% H2O2 in saline, or 3% topical solution for 5, 10, 15, 20, and 30 minutes. Results were analyzed with a two-way analysis of variance (ANOVA) (p < 0.05).


Bone & Joint 360
Vol. 7, Issue 3 | Pages 21 - 24
1 Jun 2018


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 16 - 16
1 Oct 2016
Crowe L Akbar M Kitson S Reilly J Kerr S Murrell G McInnes I Gilchrist D Millar N
Full Access

Alarmins- also referred to as damage associated molecular patterns (DAMPS)- are endogenous molecules mobilized in response to tissue damage known to activate the innate immune system and regulate tissue repair and remodelling. The molecular mechanisms that regulate inflammatory and remodelling pathways in tendinopathy are largely unknown therefore identifying early immune effectors is essential to understanding the pathology. S100A8 and S100A9 are low molecular weight calcium binding proteins primarily released by activated phagocytes in an inflammatory setting and also secreted as a heterodimeric complex that exhibits cytokine like functions. Based on our previous investigations we sought evidence of S100A8/A9 expression in human tendinopathy and thereafter, to explore mechanisms whereby S100 proteins may regulate inflammatory mediators and matrix regulation in human tenocytes. Torn supraspinatus tendon (established pathology) and matched intact subscapularis tendon (representing ‘early pathology’) biopsies were collected from patients undergoing arthroscopic shoulder surgery. Control samples of subscapularis tendon were collected from patients undergoing arthroscopic stabilisation surgery. S100A8/A9 expression was analysed at transcript and protein level using quantitative RT-PCR and immunohistochemistry, respectively. Primary human tenocytes were cultured from hamstring tendon tissue obtained during hamstring tendon ACL reconstruction. The in vitro effect of recombinant human S100 A8/A9 on primary human tenocytes was measured using quantitative RT-PCR and ELISA. Immunohistochemistry of tendinopathic tissues demonstrated the presence of S100 A8/A9 in diseased tissues compared to control tissue. In addition, early pathological diseased tissue indicated greater S100A9 expression compared with established diseased pathology. These findings were reflected by data obtained at transcript level from diseased tissues. Recombinant human S100A8, A9 and A8/A9 complex led to significant increase in expression of inflammatory mediators, including IL-6 in vitro. Further analysis via quantitative RT-PCR demonstrated recombinant S100A8, A9 and A8/A9 complex treatment on tenocytes, in vitro, had no direct effect on the expression of genes involved in matrix remodelling. The presence of S100A8 and S100A9 in early tendinopathic lesions suggests expression is upregulated in response to cellular damage. S100A8 and S100A9 are endogenous ligands of Toll-like receptors (TLRs) and receptor for advanced glycation end products (RAGE). These receptors have known regulatory effects on immune mediated cytokine production. We propose S100A8 and S100A9 as active alarmins in the early stages of tendinopathy and thus targeting of its downstream signalling may offer novel therapeutic approaches in the management of human tendon disorders


Bone & Joint 360
Vol. 4, Issue 5 | Pages 18 - 20
1 Oct 2015

The October 2015 Shoulder & Elbow Roundup360 looks at: Culture time important in propionibacterium acnes; Microvascularisation of the cuff footprint; Degenerative cuff tears: evidence for repair; Middle ground in distal humeral fractures?; Haste needed in elbow heterotopic ossification; Iatrogenic frozen shoulder; Salvage of failed humeral fixation


Bone & Joint 360
Vol. 4, Issue 4 | Pages 23 - 24
1 Aug 2015

The August 2015 Shoulder & Elbow Roundup360 looks at: Clavicular fractures are being fixed – but how?; Propionibacterium acnes: a pain in the shoulder?; Bacteria, armpits and arthroplasty; Living longer, but unhappy: the woes of shoulder arthroplasty in the under 50s; Recurrent dislocations in the adolescent population; Splinting for elbow stiffness; Revision Bankart repair