The October 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after
Adequate visual clarity is paramount to performing
Adequate visual clarity is paramount to performing
Interscalene brachial plexus block is the standard regional analgesic technique for shoulder surgery. Given its adverse effects, alternative techniques have been explored. Reports suggest that the erector spinae plane block may potentially provide effective analgesia following shoulder surgery. However, its analgesic efficacy for shoulder surgery compared with placebo or local anaesthetic infiltration has never been established. We conducted a randomised controlled trial to compare the analgesic efficacy of pre-operative T2 erector spinae plane block with peri-articular infiltration at the end of surgery. Sixty-two patients undergoing arthroscopic shoulder repair were randomly assigned to receive active erector spinae plane block with saline peri-articular injection (n = 31) or active peri-articular injection with saline erector spinae plane block (n = 31) in a blinded double-dummy design. Primary outcome was resting pain score in recovery. Secondary outcomes included pain scores with movement; opioid use; patient satisfaction; adverse effects in hospital; and outcomes at 24 h and 1 month. There was no difference in pain scores in recovery, with a median difference (95%CI) of 0.6 (-1.9-3.1), p = 0.65. Median postoperative oral morphine equivalent utilisation was significantly higher in the erector spinae plane group (21 mg vs. 12 mg; p = 0.028). Itching was observed in 10% of patients who received erector spinae plane block and there was no difference in the incidence of significant nausea and vomiting. Patient satisfaction scores, and pain scores and opioid use at 24 h were similar. At 1 month, six (peri-articular injection) and eight (erector spinae plane block) patients reported persistent pain. Erector spinae plane block was not superior to peri-articular injection for
Introduction and Objective. Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes. Materials and Methods. This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion. Results. Eight RCTs were included in the systematic review and data from 7 of these studies pooled in the meta-analysis. A total of 708 patients were randomized across the studies (406 received TXA, 302 received placebo). Studies included patients undergoing anatomic or reverse total shoulder arthroplasty, open Latarjet surgery, and arthroscopic rotator cuff repair. Pooled analysis demonstrated significant reduction in perioperative bleeding with TXA compared to controls; estimated total blood loss (mean difference [MD], −209.66; 95% CI −389.11 to −30.21; p=0.02), and post-operative blood loss (via drain output) (MD, −84.8ml; 95% CI, −140.04 to −29.56; p=0.003). A mean difference in Visual Analogue Scale (VAS) of 2.93 was noted in favour of TXA (95% CI 0.2 to 5.66; p=0.04). Conclusions. Whilst noting some risk of bias within the studies, TXA was effective in reducing blood loss and pain in shoulder surgery. There may be a benefit of TXA use in both open and
The purpose of this study is the evaluate the net promotor score of arthroscopic subacromial decompression and rotator cuff repair. The Friends and Family Test, a variant of the Net Promoter Score, was adapted for the National Health Service to evaluate overall patient satisfaction and how likely patients are to recommend an intervention. It ranges from −100 to 100. Positive scores indicate good performance. This study quantifies the scores in 71 patients at 1 year following arthroscopic sub acromial decompression and rotator cuff repair. All of the procedures were performed by 1 consultant shoulder specialist. The patient filled out a shoulder questionnaire pre-operatively, at 6 months and 1 year. The score was 72 for subacromial decompression (n = 32) and 85 for rotator cuff repair +/− decompression (n = 39). Oxford shoulder score was also taken and had a rise of 4.3 and 6.9 respectively. Our study indicates that these procedures are highly valued and are recommended by patients according to the Friends and Family Test. The results of the Friends and Family Test correlated well with postoperative functional improvement and satisfaction. We conclude from this study that a compound score based on the Friends and Family Test is a useful addition to traditional measures of patient satisfaction.
Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
The aim of this study was to investigate the influence of age on the cost-effectiveness of arthroscopic rotator cuff repair. A total of 112 patients were prospectively monitored for two years after arthroscopic rotator cuff repair using the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH), the Oxford Shoulder Score (OSS), and the EuroQol five-dimension questionnaire (EQ-5D). Complications and use of healthcare resources were recorded. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). Propensity score-matching was used to compare those aged below and above 65 years of age. Satisfaction was determined using the Net Promoter Score (NPS). Linear regression was used to identify variables that influenced the outcome at two years postoperatively.Aims
Patients and Methods
Objectives. Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Methods. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio). Results. ICG fluorescence angiography allowed for visualization of blood flow in the rotator cuff in all groups. The adhesive capsulitis group showed significantly earlier enhancement than the other groups. Furthermore, the adhesive capsulitis group had a significantly smaller hypovascular area ratio than the other groups. Conclusion. ICG fluorescence angiography allowed for evaluation of real-time blood flow of the rotator cuff in
The purpose of this study was to examine the bactericidal efficacy of hydrogen peroxide (H2O2) on The effect of H2O2 was assessed by testing bactericidal effect, time course analysis, growth inhibition, and minimum bactericidal concentration. To assess the bactericidal effect, bacteria were treated for 30 minutes with 0%, 1%, 3%, 4%, 6%, 8%, or 10% H2O2 in saline or water and compared with 3% topical H2O2 solution. For time course analysis, bacteria were treated with water or saline (controls), 3% H2O2 in water, 3% H2O2 in saline, or 3% topical solution for 5, 10, 15, 20, and 30 minutes. Results were analyzed with a two-way analysis of variance (ANOVA) (p < 0.05).Objectives
Methods
Alarmins- also referred to as damage associated molecular patterns (DAMPS)- are endogenous molecules mobilized in response to tissue damage known to activate the innate immune system and regulate tissue repair and remodelling. The molecular mechanisms that regulate inflammatory and remodelling pathways in tendinopathy are largely unknown therefore identifying early immune effectors is essential to understanding the pathology. S100A8 and S100A9 are low molecular weight calcium binding proteins primarily released by activated phagocytes in an inflammatory setting and also secreted as a heterodimeric complex that exhibits cytokine like functions. Based on our previous investigations we sought evidence of S100A8/A9 expression in human tendinopathy and thereafter, to explore mechanisms whereby S100 proteins may regulate inflammatory mediators and matrix regulation in human tenocytes. Torn supraspinatus tendon (established pathology) and matched intact subscapularis tendon (representing ‘early pathology’) biopsies were collected from patients undergoing
The October 2015 Shoulder &
Elbow Roundup360 looks at: Culture time important in propionibacterium acnes; Microvascularisation of the cuff footprint; Degenerative cuff tears: evidence for repair; Middle ground in distal humeral fractures?; Haste needed in elbow heterotopic ossification; Iatrogenic frozen shoulder; Salvage of failed humeral fixation
The August 2015 Shoulder &
Elbow Roundup360 looks at: Clavicular fractures are being fixed – but how?;