The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength, range of motion, radiological parameters, healthcare resource use, and cost-effectiveness between the groups. A prospectively registered (ISRCTN95922938) randomized parallel group trial will be conducted. Elderly patients meeting the inclusion criteria with a dorsally displaced distal radius facture will be randomized (1:1 ratio) to either conservative management (cast without further manipulation) or surgery. Patients will be assessed at six, 12, 26 weeks, and 52 weeks post intervention. The primary outcome measure and endpoint will be the Patient-Rated Wrist Evaluation (PRWE) at 52 weeks. In addition, the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH), EuroQol five-dimension questionnaire, pain score (visual analogue scale 1 to 10), complications, grip strength (dynamometer), range of motion (goniometer), and radiological assessments will be undertaken. A cost-utility analysis will be performed to assess the cost-effectiveness of surgery. We aim to recruit 89 subjects per arm (total sample size 178).Aims
Methods
The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support. The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared.Aims
Methods
The October 2024 Wrist & Hand Roundup360 looks at: Circumferential casting versus plaster splinting in preventing redisplacement of distal radial fractures; Comparable outcomes for operative versus nonoperative treatment of scapholunate ligament injuries in distal radius fractures; Perceived pain during the reduction of Colles fracture without anaesthesia; Diagnostic delays and physician training are key to reducing scaphoid fracture nonunion; Necrotizing fasciitis originating in the hand: a systematic review and meta-analysis; Study design influences outcomes in distal radial fracture research; Long-term results of index finger pollicization for congenital thumb anomalies: a systematic review; Enhancing nerve injury diagnosis: the evolving role of imaging and electrodiagnostic tools.
The December 2023 Wrist & Hand Roundup. 360. looks at:
The December 2022 Trauma Roundup360 looks at: Anterior approach for acetabular fractures using anatomical plates; Masquelet–Ilizarov for the management of bone loss post debridement of infected tibial nonunion; Total hip arthroplasty – better results after low-energy displaced femoral neck fracture in young patients; Unreamed intramedullary nailing versus external fixation for the treatment of open tibial shaft fractures in Uganda: a randomized clinical trial; The Open-Fracture Patient Evaluation Nationwide (OPEN) study: the management of open fracture care in the UK; Cost-utility analysis of cemented hemiarthroplasty versus hydroxyapatite-coated uncemented hemiarthroplasty; Unstable ankle fractures: fibular nail fixation compared to open reduction and internal fixation; Long-term outcomes of randomized clinical trials: wrist and calcaneus; ‘HeFT’y follow-up of the UK Heel Fracture Trial.
The purpose was to compare operative treatment with a volar plate and nonoperative treatment of displaced distal radius fractures in patients aged 65 years and over in a cost-effectiveness analysis. A cost-utility analysis was performed alongside a randomized controlled trial. A total of 50 patients were randomized to each group. We prospectively collected data on resource use during the first year post-fracture, and estimated costs of initial treatment, further operations, physiotherapy, home nursing, and production loss. Health-related quality of life was based on the Euro-QoL five-dimension, five-level (EQ-5D-5L) utility index, and quality-adjusted life-years (QALYs) were calculated.Aims
Methods
Aims. To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. Methods. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a
Aims. Fixation of scaphoid nonunion with a
The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius. We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.Aims
Methods
Distal radius fracture is one of the most common fractures in older women (∼70,000 cases annually in Canada). Treatment of this fracture has been shifting toward surgery (mainly
Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of
Distal radius fractures are the most common osteoporotic fractures among women. The treatment of these fractures has been shifting from a traditional non-operative approach to surgery, using