Advertisement for orthosearch.org.uk
Results 1 - 20 of 185
Results per page:
Bone & Joint 360
Vol. 11, Issue 2 | Pages 5 - 10
1 Apr 2022
Zheng A Rocos B


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 321 - 330
1 Mar 2022
Brzeszczynski F Brzeszczynska J Duckworth AD Murray IR Simpson AHRW Hamilton DF

Aims

Sarcopenia is characterized by a generalized progressive loss of skeletal muscle mass, strength, and physical performance. This systematic review primarily evaluated the effects of sarcopenia on postoperative functional recovery and mortality in patients undergoing orthopaedic surgery, and secondarily assessed the methods used to diagnose and define sarcopenia in the orthopaedic literature.

Methods

A systematic search was conducted in MEDLINE, EMBASE, and Google Scholar databases according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Studies involving sarcopenic patients who underwent defined orthopaedic surgery and recorded postoperative outcomes were included. The quality of the criteria by which a diagnosis of sarcopenia was made was evaluated. The quality of the publication was assessed using Newcastle-Ottawa Scale.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 97 - 102
1 Jan 2022
Hijikata Y Kamitani T Nakahara M Kumamoto S Sakai T Itaya T Yamazaki H Ogawa Y Kusumegi A Inoue T Yoshida T Furue N Fukuhara S Yamamoto Y

Aims

To develop and internally validate a preoperative clinical prediction model for acute adjacent vertebral fracture (AVF) after vertebral augmentation to support preoperative decision-making, named the after vertebral augmentation (AVA) score.

Methods

In this prognostic study, a multicentre, retrospective single-level vertebral augmentation cohort of 377 patients from six Japanese hospitals was used to derive an AVF prediction model. Backward stepwise selection (p < 0.05) was used to select preoperative clinical and imaging predictors for acute AVF after vertebral augmentation for up to one month, from 14 predictors. We assigned a score to each selected variable based on the regression coefficient and developed the AVA scoring system. We evaluated sensitivity and specificity for each cut-off, area under the curve (AUC), and calibration as diagnostic performance. Internal validation was conducted using bootstrapping to correct the optimism.


Abstract. Objectives. To evaluate the safety and efficacy of vertebroplasty with short segmented cement augmented pedicle screws fixation for severe osteoporotic vertebral compression fractures (OVCF) with posterior/anterior wall fractured patients. Methods. A retrospective study of 24 patients of DGOU type-4 (vertebra plana) OVCF with posterior/anterior wall fracture, were treated by vertebroplasty and short segment PMMA cement augmented pedicle screws fixation. Radiological parameters (kyphosis angle and compression ratio) and clinical parameters Visual analogue scale (VAS) and Oswestry disability index (ODI) were analysed. Results. A significant improvement was noted in VAS (preoperative, 7.90 ± 0.60; final follow-up 2.90 ± 0.54) and ODI (77.10 ± 6.96 to 21.30 ± 6.70), (P < 0.05). Neurological improvement was noted in all patients. Kyphosis corrected significantly from preoperative 23.20 ± 5.90 to 5.30 ± 1.40 postoperative with 5% (3.30 ± 2.95) loss of correction at final follow-up. Anterior vertebral height restored significantly from 55.80 ± 11.9% to 87.6 ± 13.1% postoperative with 4.5 ± 4.0% loss at final follow-up. One case had cement leakage was found, but the patient is asymptomatic. No implant-related complication was seen. No iatrogenic dural or nerve injury. Conclusions. Treatment with vertebroplasty with cement augmented screw fixation and direct decompression is a great option in treating such a complex situation in fragile age with fragile bones because. Vertebroplasty is viable option for restoring vertebral anterior column in patients who are considered as contraindications for vertebroplasty, like DGOU-4. It provides anterior support avoiding corpectomy, minimise blood loss and also duration of surgery. Addition of short segment fixation gives adequate support with less stress risers at the junctional area


Abstract. Objectives. The principle of osteoporotic vertebral compression fracture (OVCF) is fixing instability, providing anterior support, and decompression. Contraindication for vertebroplasty is anterior or posterior wall fracture. The study objectives was to evaluate the efficacy and safety of vertebroplasty with short segmented PMMA cement augmented pedicle screws for OVCF with posterior/anterior wall fracture patients. Methods. A retrospective study of 24 patients of DGOU type-4 (vertebra plana) OVCF with posterior/anterior wall fracture, were treated by vertebroplasty and short segment PMMA cement augmented pedicle screws fixation. Radiological parameters (kyphosis angle and compression ratio) and clinical parameters Visual analogue scale (VAS) and Oswestry disability index (ODI) were analysed. Results. A significant improvement was noted in VAS (preoperative, 7.90 ±0.60; final follow-up 2.90 ± 0.54) and ODI (77.10 ± 6.96 to 21.30 ± 6.70), (P < 0.05). Neurological improvement was noted in all patients. Kyphosis corrected significantly from preoperative 23.20±5.90 to 5.30±1.40 postoperative with 5% (3.30± 2.95) loss of correction at final follow-up. Anterior vertebral height restored significantly from 55.80±11.9% t0 87.6±13.1% postoperative with 4.5±4.0% loss at final follow-up. One case had cement leakage was found, but the patient is asymptomatic. No implant-related complication was seen. No iatrogenic dural or nerve injury. Conclusions. Treatment with vertebroplasty with cement augmented screw fixation and direct decompression is a great option in treating such a complex situation in fragile age with fragile bones because It provides anterior support with cementing that avoids corpectomy. Short segment fixation has less stress risers at the junctional area


Bone & Joint 360
Vol. 9, Issue 5 | Pages 35 - 37
1 Oct 2020


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 2 - 2
1 Jul 2020
Ali Z Sahgal A David E Chow E Burch S Wilson B Yee AJ Whyne C Detsky J Fisher C
Full Access

The spine is a common site of metastasis. Complications include pathologic fracture, spinal cord compression, and neurological deficits. Vertebroplasty (VP) and Balloon Kyphoplasty (KP) are minimally invasive stabilization procedures used as a palliative treatment to improve mechanical stability, quality of life, and reduce pain. Photodynamic therapy (PDT) is a tumour-ablative modality that may complement mechanical stability afforded by VP/KP. This first-in-human study evaluates PDT safety when applied in conjunction with VP/KP. This dose escalation trial involved one light only control group and four light-drug doses (50,100,150,200J;n=6) delivered at 150mW from a 690nm diode laser by 800-micron optical fibers prior to KP/VP. Patients eligible for VP/KP in treating pathologic fracture or at-risk lesions at a single level were recruited. Exclusion criteria included spinal canal compromise or neurologic impairment. PDT is a two-step binary therapy of systemic drug followed by intravertebral light activation. Light was applied via bone trochar prior to cementation. This study used a benzoporphyrin derivative monoacid (BPD-MA), Verteporfin (VisudyneTm), as the photosensitizer drug in the therapy. Drug/light safety, neurologic safety, generic (SF-36), and disease-specific outcomes (VAS, EORTC-QLQ-BM22, EORTC-QLQ-C15-PAL) were recorded through six weeks. Phototoxicity and the side effects of the BPD-MA were also examined following PDT use. Thirty (10 male, 20 female) patients were treated (13 KP, 17 VP). The average age was 61 and significantly different between genders (Male 70yrs vs. Female 57yrs: p 0.05), and tumour status (lytic vs. mixed blastic/lytic: p>0.05). In most cases, fluence rates were similar throughout PDT treatment time, indicating a relatively stable treatment. Twelve (40%) of patients experienced complications during the study, none of which were attributed to PDT therapy. This included two kyphoplasty failures due to progression of disease, one case of shingles, one ankle fracture, one prominent suture, one case of constipation due to a lung lesion, one case of fatigue, and five patients experienced pain that was surgically related or preceded therapy. Vertebral PDT appears safe from pharmaceutical and neurologic perspectives. KP/VP failure rate is broadly in line with reported values and PDT did not compromise efficacy. The 50J group demonstrated an improved response. Ongoing study determining safe dose range and subsequent efficacy studies are necessary


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 568 - 572
1 May 2020
McDonnell JM Ahern DP Ó Doinn T Gibbons D Rodrigues KN Birch N Butler JS

Continuous technical improvement in spinal surgical procedures, with the aim of enhancing patient outcomes, can be assisted by the deployment of advanced technologies including navigation, intraoperative CT imaging, and surgical robots. The latest generation of robotic surgical systems allows the simultaneous application of a range of digital features that provide the surgeon with an improved view of the surgical field, often through a narrow portal.

There is emerging evidence that procedure-related complications and intraoperative blood loss can be reduced if the new technologies are used by appropriately trained surgeons. Acceptance of the role of surgical robots has increased in recent years among a number of surgical specialities including general surgery, neurosurgery, and orthopaedic surgeons performing major joint arthroplasty. However, ethical challenges have emerged with the rollout of these innovations, such as ensuring surgeon competence in the use of surgical robotics and avoiding financial conflicts of interest. Therefore, it is essential that trainees aspiring to become spinal surgeons as well as established spinal specialists should develop the necessary skills to use robotic technology safely and effectively and understand the ethical framework within which the technology is introduced.

Traditional and more recently developed platforms exist to aid skill acquisition and surgical training which are described.

The aim of this narrative review is to describe the role of surgical robotics in spinal surgery, describe measures of proficiency, and present the range of training platforms that institutions can use to ensure they employ confident spine surgeons adequately prepared for the era of robotic spinal surgery.

Cite this article: Bone Joint J 2020;102-B(5):568–572.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1479 - 1488
1 Dec 2019
Laverdière C Corban J Khoury J Ge SM Schupbach J Harvey EJ Reindl R Martineau PA

Aims

Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics.

Materials and Methods

A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.


Bone & Joint 360
Vol. 8, Issue 4 | Pages 32 - 34
1 Aug 2019


Bone & Joint 360
Vol. 8, Issue 3 | Pages 29 - 31
1 Jun 2019


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 10 - 10
1 Nov 2018
Kelly A McEvoy F Tiernan S Morris S
Full Access

Balloon kyphoplasty (BKP) is a minimally invasive surgical technique used to correct kyphosis and vertebral compression fractures. BKP uses cement to fill a void created by the inflation of a balloon in a vertebra, it can be used as an alternative to vertebroplasty to reduce cement extravasation. Issues such as poor inter digitisation of the cement and the trabecular bone can arise with the BKP method. This can be due to a compacted layer created during the procedure which can cause complications post-surgery. The primary aim of this study was to investigate alternative cement application methods which could improve the mechanical strength of the bone-cement interface. Three alternative methods were investigated, and cylindrical bone-cement specimens were created for all methods (BKP and three alternatives). An important part of this study was to replicate the compacted layer created by the inflation of the balloon tamp in BKP. Synthetic trabecular bone specimens (Sawbones®, Pacific Research Laboratories, Vashon Island, Washington, USA) were pre-loaded in compression and the resultant compacted layers were found to replicate the compacted layers found in surgery. Mechanical testing was carried out with an MTS Model 858 Bionix. ®. Servohydraulic load frame using static tensile and torsion loads. Static tests revealed that two of the three alternative methods were an improvement on BKP, with a high statistical significance in relation to the mechanical performance of the bone-cement interface (P < 0.001). This data illustrates the potential to improve the standard BKP technique, in terms of bone-cement interface performance


Bone & Joint 360
Vol. 7, Issue 4 | Pages 25 - 28
1 Aug 2018


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims

Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically.

Methods

Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 38 - 39
1 Jun 2018
Das A


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 80 - 80
1 Dec 2017
Liao J
Full Access

Aim. Infection after vertebroplasty (VP) is a rare but serious complication. Previous literatures showed most pathogens for infection after VP were bacteria; tuberculosis (TB) induced infection after VP was extremely rare. In this study, we reported our treatment experiences of 18 cases with infectious spondylitis after VP, and compared the differences between developed pyogenic and TB spondylitis. Method. From January 2001 to December 2015, 5749 patients underwent VP at our department were reviewed retrospectively. The causative organisms were obtained from tissue culture of revision surgery. Parameters including type of surgery, the interval between VP and revision surgery, neurologic status, and visual analog scale of back pain were recorded. Laboratory data at the time of VP and revision surgery were collected. Risk factors including the Charlson comorbidity index (CCI), preoperative bacteremia, urinary tract infection (UTI), pulmonary TB history were also analyzed. Results. 18 patients developed infectious spondylitis after VP (0.32%, 18/5749). Two were male and 16 were female. The median age at the time of VP was 73.4 years. The mean CCI score was 1.7. The causative organisms were TB in nine patients (Fig. 1), and bacteria in nine patients (Fig. 2). The interval between VP and revision surgery ranged from 7 to 1140 days (mean 123.2 days). C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were elevated in most patients especially at readmission. The most common type of revision surgery was anterior combined posterior surgery. Seven patients developed neurologic deficit before revision surgery. Three patients died within 6 months after revision surgery, with a mortality of 16.7%. Finally, VAS of back pain was improved from 7.4 to 3.1. 7 patients could walk normally, 5 patients needed walker support, 3 patients depended on wheelchair for ambulation (Table 1). Both pyogenic and TB group had similar age, sex, and CCI distribution. The interval between VP and revision surgery was shorter in the patients with pyogenic organisms (75.9 vs 170.6 days). At revision surgery, WBC and CRP were prominently elevated in the pyogenic group. Five in the pyogenic group had UTI or bacteremia; five in TB group had a history of lung TB (Table 2). Conclusions. VP is a minimal procedure but sustains possibility of postoperative infection, which required major surgery for salvage with a relevant part of residual disability. Before surgery, any bacteremia/ UTI or history of pulmonary TB should be reviewed rigorously; any elevation of infection parameters should be scrutinized strictly. For any figures and tables, please contact authors directly (click on ‘Info & Metrics’ tab above for contact details)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 107 - 107
1 Jan 2017
Danesi V Tozzi G Soffiatti R Cristofolini L
Full Access

Prophylactic augmentation is meant to reinforce the vertebral body (VB), but in some cases it is suspected to actually weaken it. To elucidate the biomechanical efficacy of prophylactic augmentation, the full-field three-dimensional strain distributions were measured for the first time inside prophylactic-augmented vertebrae. Twelve thoracic porcine vertebrae were assigned to three groups: 4 were augmented with bone cement for vertebroplasty (Mendec-Spine, Tecres), 4 were treated with another bone cement for vertebroplasty (Calcemex-Spine, Tecres) while the other 4 were tested untreated as a control. Destructive tests were carried out under axial compression, in a step-wise fashion (unloaded, 5%, 10% and 15% compression). At each loading step, μCT-images were acquired. The internal strain distribution was investigated by means of DVC analysis. Some augmented specimens were stronger than the respective control, while others were weaker. In most of the specimens, the strain distribution in the elastic regime (5% compression) seemed to predict the location of the micro-damage initiation before it actually became identifiable (at 10% and 15% compression). The measured strain had the same order of magnitude for all groups. However, in the control vertebrae, the highest strain would unpredictably appear at any location inside the VB. Conversely, for both augmentation groups, the highest strains were measured in the regions adjacent to the injected cement mass, whereas the cement-interdigitated-bone was less strained. Localization of high strains and failure was consistent between specimens, but different between the two cement types: with Mendec-Spine failure the highest strains were mainly localized at mid-height and at the same level where the cement mass was localized; with Calcemex-Spine failure the highest strains were mainly cranial and caudal to the cement mass. Both the micro-CT images, and the DVC strain analysis highlighted that:. The cement mass was less strained than any other regions in the vertebra. Failure never started inside the cement mass. This can be explained with the additional stiffening and reinforcement associated with the infiltration of the cement inside the trabecular bone. The highest strains and failure were localized in the bone adjacent to the cement-bone interdigitated region. This can be explained by the strain concentration between the cement-interdigitated bone (stiffer and stronger), and the adjacent non-augmented trabecular bone. The strain maps in the elastic regime and the localization of failure was different in the augmented vertebrae, when compared to the natural controls. This suggests an alteration of the load sharing in the augmented structure where the load is mostly carried by the cement region. The different localization of failure initiation between the two augmented groups could be explained by the different mechanical properties of the two cements. This study has demonstrated the potential of DVC in measuring the internal strain and failure in prophylactic-augmented vertebrae. It has been shown that failure starts inside the augmented VB, next to the injected cement mass. This can help establishing better criteria (in terms of localization of the cement mass) in order to improve clinical protocols for vertebroplasty surgical procedures


Bone & Joint 360
Vol. 5, Issue 6 | Pages 37 - 39
1 Dec 2016


Bone & Joint Research
Vol. 5, Issue 11 | Pages 544 - 551
1 Nov 2016
Kim Y Bok DH Chang H Kim SW Park MS Oh JK Kim J Kim T

Objectives. Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients. Patients and Methods. Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores. Results. A total of 342 patients finished the 12-week follow-up, and 120 patients underwent vertebroplasty (35.1%). The effect of vertebroplasty over conservative treatment was significant regardless of age, body mass index, medical comorbidity, previous fracture, pain duration, bone mineral density, degree of vertebral body compression, and canal encroachment. However, the effect of vertebroplasty was not significant at all time points in patients with increased sagittal vertical axis. Conclusions. For single-level acute osteoporotic vertebral compression fractures, the effect of vertebroplasty was less favourable in patients with increased sagittal vertical axis (> 5 cm) possible due to aggravation of kyphotic stress from walking imbalance. Cite this article: Y-C. Kim, D. H. Bok, H-G. Chang, S. W. Kim, M. S. Park, J. K. Oh, J. Kim, T-H. Kim. Increased sagittal vertical axis is associated with less effective control of acute pain following vertebroplasty. Bone Joint Res 2016;5:544–551. DOI: 10.1302/2046-3758.511.BJR-2016-0135.R1


Bone & Joint 360
Vol. 5, Issue 4 | Pages 31 - 33
1 Aug 2016