Advertisement for orthosearch.org.uk
Results 1 - 20 of 58
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 20 - 20
16 May 2024
Bernasconi A Cooper L Lyle S Patel S Cullen N Singh D Welck M
Full Access

Introduction. Pes cavovarus is a foot deformity that can be idiopathic (I-PC) or acquired secondary to other pathology. Charcot-Marie-Tooth disease (CMT) is the most common adult cause for acquired pes cavovarus deformity (CMT-PC). The foot morphology of these distinct patient groups has not been previously investigated. The aim of this study was to assess if morphological differences exist between CMT-PC, I-PC and normal feet (controls) using weightbearing computed tomography (WBCT). Methods. A retrospective analysis of WBCT scans performed between May 2013 and June 2017 was undertaken. WBCT scans from 17 CMT-PC, 17 I-PC and 17 healthy normally-aligned control feet (age-, side-, sex- and body mass index-matched) identified from a prospectively collected database, were analysed. Eight 2-dimensional (2D) and three 3-dimensional (3D) measurements were undertaken for each foot and mean values in the three groups were compared using one-way ANOVA with the Bonferroni correction. Results. Significant differences were observed between CMT-PC or I-PC and controls (p< 0.05). Two-dimensional measurements were similar in CMT-PC and I-PC, except for forefoot arch angle (p= 0.04). 3D measurements (foot and ankle offset, calcaneal offset and hindfoot alignment angle) demonstrated that CMT-PC exhibited more severe hindfoot varus malalignment than I-PC (p= 0.03, 0.04 and 0.02 respectively). Discussion. CMT-related cavovarus and idiopathic cavovarus feet are morphologically different from healthy feet, and CMT feet exhibit increased forefoot supination and hindfoot malalignment compared to idiopathic forms. The use of novel three-dimensional analysis may help highlight subtle structural differences in patients with similar foot morphology but aetiologically different pathology


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 53 - 53
1 Dec 2021
De Vecchis M Naili JE Wilson C Whatling GM Holt CA
Full Access

Abstract. Objectives. Exploring the relationship of gait function pre and post total knee replacement (TKR) in two groups of patients. Methods. Three-dimensional gait analysis was performed at Cardiff University, UK, and Karolinska University Hospital, Sweden, on 29 and 25 non-pathological (NP) volunteers, and 39 and 28 patients with end-stage knee osteoarthritis (OA), respectively. Patients were assessed pre and one-year post-TKR. Data reduction was performed via Principal Component (PC) analysis on twenty-four kinematic and kinetic waveforms in both NP and pre/post-TKR. Cardiff's and Karolinska's cohorts were analysed separately. The Cardiff Classifier, a classification system based on the Dempster-Shafer theory, was trained with the first 3 PCs of each variable for each cohort. The Classifier classifies each participant by assigning them a belief in NP, belief in OA (BOA) and belief in uncertainty, based on their biomechanical features. The correlation between patient's BOA values (range: 0–1, 0 indicates null BOA and 1 high BOA) pre and post-TKR was tested through Spearman's correlation coefficient in each cohort. The related-samples Wilcoxon signed-rank test (α=0.05) determined the significant changes in BOA in each cohort of patients. The Mann-Whitney U test (α=0.05) was run to explore differences between the patients’ cohorts. Results. There were no significant differences between patients’ cohorts in median age (p=0.096), height (p=0.673), weight (p=0.064) or KOOS sub-scores pre or post-TKR (p-value ranged 0.069 to 0.955) but Cardiff's patients had a significantly higher BMI (p=0.047). There was a significant, median decrease of 0.12 and 0.19 in the BOA pre to post TKR (p<0.001) in Cardiff's and Karolinska's patients, respectively. There was a statistically significant, strong positive correlation between the BOA pre and post-TKR (Cardiff:r. s. =0.706, p<0.001; Karolinska:r. s. =0.669, p<0.001). Conclusions. In two distinct cohorts of patients, having a more compromised gait function in end-stage knee OA was correlated with poorer gait function post-TKR


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 59 - 59
1 Mar 2021
Bowd J van Rossom S Wilson C Elson D Jonkers I Whatling G Holt C
Full Access

Abstract. Objective. Explore whether high tibial osteotomy (HTO) changes knee contact forces and to explore the relationship between the external knee adduction moment (EKAM) pre and 12 months post HTO. Methods. Three-dimensional gait analysis was performed on 17 patients pre and 12-months post HTO using a modified Cleveland marker-set. Tibiofemoral contact forces were calculated in SIMM. The scaled musculoskeletal model integrated an extended knee model allowing for 6 degrees of freedom in the tibiofemoral and patellofemoral joint. Joint angles were calculated using inverse kinematics then muscle and contact forces and secondary knee kinematics were estimated using the COMAC algorithm. Paired samples t-test were performed using SPSS version 25 (SPSS Inc., USA). Testing for normality was undertaken with Shapiro-Wilk. Pearson correlations established the relationships between EKAM1 to medial KCF1, and EKAM2 to medial KCF2, pre and post HTO. Results. Total knee contact force peak 1 significantly reduced from 2.6 x body weight pre-HTO to 2.3 x body weight 12-months post-HTO. Medial contact force peak 1 significantly reduced from 1.7 x body weight pre-HTO to 1.5 x body weight 12-months post-HTO. Second peak lateral knee contact force significantly increased from 0.9 body weight pre-HTO to 1.1 x body weight 12-months post-HTO. Furthermore, this study found very strong correlations between EKAM1 and medial KCF1 pre-HTO (r=0.85) as well as post-HTO (r=0.91). There was a significantly moderate relationship between EKAM2 and medial KCF2 pre-HTO (r=0.625). Conclusion. HTO significantly reduced overall and medial KCF during the first half of stance whilst increasing second half of stance peak lateral knee contact force. This study demonstrated a strong relationship between EKAM peaks and respective medial KCF peaks, supporting the usefulness of EKAM as a surrogate measure of medial compartment tibiofemoral contact forces. This demonstrates HTO successfully offloads the tibiofemoral joint overall, as well as offloading the medial compartment


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 14 - 14
1 Jul 2020
Young K Wilson JA Dunbar MJ Roy P Abidi S
Full Access

Identifying knee osteoarthritis (OA) patient phenotypes is relevant to assessing treatment efficacy, yet biomechanical variability has not been applied to phenotyping. This study aimed to identify demographic and gait related groups (clusters) among total knee arthroplasty (TKA) candidates, and examine inter-cluster differences in gait feature improvement post-TKA. Knee OA patients scheduled for TKA underwent three-dimensional gait analysis one-week pre and one-year post-TKA, capturing lower-limb external ground reaction forces and kinematics using a force platform and optoelectronic motion capture. Principal component analysis was applied to frontal and sagittal knee angle and moment waveforms (n=135 pre-TKA, n=106 post-TKA), resulting in a new uncorrelated dataset of subject PCscores and PC vectors, describing major modes of variability throughout one gait cycle (0–100%). Demographics (age, gender, body mass index (BMI), gait speed), and gait angle and moment PCscores were standardized and assessed for outliers. One patient exceeding Tukey's outer (3IQR) fence was removed. Two-dimensional multidimensional scaling followed by k-medoids clustering was applied to scaled demographics and pre-TKA PCscores [134×15]. Number of clusters (k=2:10) were assessed by silhouette coefficients, s, and stability by Adjusted Rand Indices (ARI) of 100 data subsets. Clusters were validated by examining inter-cluster differences at baseline, and inter-cluster gait changes (PostPCscore–PrePCscore, n=105) by k-way ANOVA and Tukey's honestly significant difference (HSD) criterion. Four (k=4) TKA candidate groups yielded optimum clustering metrics (s = 0.4, ARI=0.75). Cluster 1 was all-males (male:female=19:0) who walked with faster gait speeds (1>2,3), larger flexion angle magnitudes and stance-phase angle range (PC1 & PC4 1>2,3,4), and more flexion (PC2 1>2,3,4) and adduction moment (PC2 & PC3 1>2,3) range patterns. Cluster 1 had the most dynamic kinematics and kinetic loading/unloading range amongst the clusters, representing a higher-functioning (less “stiff”) male subset. Cluster 2 captured older (2>1,3) males (31:1) with slower gait speeds (2 4), and lower flexion angle magnitude (PC1 3 2,3) and less stiff kinematic and kinetic patterns relative to Clusters 2 and 3, representing a higher-functioning female subset. Radiographic severity did not differ between clusters (Kellgren-Lawrence Grade, p=0.9, n=102), and after removing demographics and re-clustering, gender differences remained (p < 0 .04). Pre-TKA, higher-functioning clusters (1&4) had more dynamic loading/un-loading kinetic patterns. Post-TKA, high-functioning clusters experienced less gait improvement (flexion angle PC2, 1,4 < 3, p≥0.004, flexion moment PC2, 4 < 2,3), with some sagittal range patterns decreasing postoperatively. TKA candidates can be characterized by four clusters, differing by demographics and biomechanical severity features. Post-TKA, functional gains were cluster-specific, stiff-gait clusters experienced more improvement, while higher-functioning clusters experienced less gain and showed some decline. Results suggest the presence of cohorts who may not benefit functionally from TKA. Cluster profiling may support triaging and developing targeted OA treatment strategies, meeting individual function needs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 109 - 109
1 Jul 2020
Kowalski E Lamontagne M Catelli D Beaulé P
Full Access

The literature indicates that femoroacetabular impingement (FAI) patients do not return to the level of controls (CTRL) following surgery. The purpose of this study was to compare hip biomechanics during stair climbing tasks in FAI patients before and two years after undergoing corrective surgery against healthy controls (CTRL). A total of 27 participants were included in this study. All participants underwent CT imaging at the local hospital, followed by three-dimensional motion analysis done at the human motion biomechanics laboratory at the local university. Participants who presented a cam deformity >50.5° in the oblique-axial or >60° in the radial planes, respectively, and who had a positive impingement test were placed in the FAI group (n=11, age=34.1±7.4 years, BMI=25.4±2.7 kg/m2). The remaining participants had no cam deformity and negative impingement test and were placed in the CTRL group (n=16, age=33.2±6.4 years, BMI=26.3±3.2 kg/m2). The CTRL group completed the biomechanics protocol once, whereas the FAI group completed the protocol twice, once prior to undergoing corrective surgery for the cam FAI, and the second time at approximately two years following surgery. At the human motion biomechanics laboratory, participants were outfitted with 45 retroreflective markers placed according to the UOMAM marker set. Participants completed five trials of stairs task on a three step instrumented stair case to measure ground reaction forces while 10 Vicon MX-13 cameras recorded the marker trajectories. Data was processed using Nexus software and divided into stair ascent and stair descent tasks. The trials were imported into custom written MatLab software to extract peak pelvis and hip kinematics and hip kinetic variables. Non-parametric Kruskal-Wallis tests were used to determine significant (p < 0.05) differences between the groups. No significant differences occurred during the stair descent task between any of the groups. During the stair ascent task, the CTRL group had significantly greater peak hip flexion angle (Pre-Op=58±7.1°, Post-Op=58.1±6.6°, CTRL=64.1±5.1°) and sagittal hip range of motion (ROM) (Pre-Op=56.7±6.7°, Post-Op=56.3±5.5°, CTRL=61.7±4.2°) than both the pre- and post-operative groups. Pre-operatively, the FAI group had significantly less peak hip adduction angle (Pre-Op=2±4.5°, Post-Op=3.4±4.4°, CTRL=5.5±3.7°) and hip frontal ROM (Pre-Op=9.9±3.4°, Post-Op=11.9±5.4°, CTRL=13.4±2.5°) compared to the CTRL group. No significant differences occurred in the kinetic variables. Our findings are in line with the Rylander and colleagues (2013) who also found that hip sagittal ROM did not improve following corrective surgery. Their study included a mix of cam and pincer-type FAI, and had a mean follow-up of approximately one year. Our cohort included only cam FAI and they had a mean follow-up of approximately two years, indicating with the extra year, the patients still did not show sagittal hip kinematics improvement. In the frontal plane, there was no significant difference between the post-op and the CTRL, indicating that the postoperative FAI reached the level of the CTRLs. This is in line with recent work that indicates a more medialized hip contact force vector following surgery, suggesting better hip stabilization


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 78 - 78
1 Jan 2018
Maranho D Kiapour A Kim Y Novais E
Full Access

The intra-epiphyseal growth of the proximal femur has been focus of studies because of the potential relationship with the development of slipped capital femoral epiphysis and cam deformity in femoroacetabular impingement. We aimed to evaluate the developmental pattern of the epiphyseal tubercle and extension in normal boys and girls from eight to fifteen years, without hip conditions. We performed three-dimensional (3D) analysis of pelvic computed tomographic scans of 80 subjects with suspect of appendicitis, consisting of five boys and five girls for each age, from eight to 15 years old. Images were segmented slice by slice at the level of the growth plate using biplanar orientation. The 3D-segmented epiphyses were used to measure the location and height of the tubercle, the height of the epiphyseal extension, and the epiphyseal diameter. We found that the epiphyseal tubercle was eccentrically located at the posterolateral quadrant of the physeal surface. The absolute height of the epiphyseal tubercle did not vary between ages (R. 2. =0.04; p=0.101). The epiphyseal diameter increased with age (R. 2. =0.74; p<0.001), making the tubercle height proportionally smaller with the epiphyseal growth (9% reduction in tubercle height normalised by the epiphyseal diameter). The normalised epiphyseal extension height significantly increased by 160% from 8 to 15 years of age. Our observation validates the hypothesis of the cupping mechanism provided by the peripheral growth of the epiphyseal extension, while the epiphyseal tubercle relatively decreases in size during the skeletal growth. Further research will be important to determine the role of these structures in the epiphyseal stability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 98 - 98
1 Jan 2017
Bonnin M Saffarini M de KoK A Verstraete M Van Hoof T Van der Straten C Victor J
Full Access

To determine the mechanisms and extents of popliteus impingements before and after TKA and to investigate the influence of implant sizing. The hypotheses were that (i) popliteus impingements after TKA may occur at both the tibia and the femur and (ii) even with an apparently well-sized prosthesis, popliteal tracking during knee flexion is modified compared to the preoperative situation. The location of the popliteus in three cadaver knees was measured using computed tomography (CT), before and after implantation of plastic TKA replicas, by injecting the tendon with radiopaque liquid. The pre- and post-operative positions of the popliteus were compared from full extension to deep flexion using normosized, oversized and undersized implants (one size increments). At the tibia, TKA caused the popliteus to translate posteriorly, mostly in full extension: 4.1mm for normosized implants, and 15.8mm with oversized implants, but no translations were observed when using undersized implants. At the femur, TKA caused the popliteus to translate laterally at deeper flexion angles, peaking between 80º-120º: 2.0 mm for normosized implants and 2.6 mm with oversized implants. Three-dimensional analysis revealed prosthetic overhang at the postero-superior corner of normosized and oversized femoral components (respectively, up to 2.9 mm and 6.6 mm). A well-sized tibial component modifies popliteal tracking, while an undersized tibial component maintains more physiologic patterns. Oversizing shifts the popliteus considerably throughout the full arc of motion. This study suggests that both femoro- and tibio-popliteus impingements could play a role in residual pain and stiffness after TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 25 - 25
1 May 2016
Matsumura N Oki S Iwamoto T Ochi K Sato K Nagura T
Full Access

Introduction

For anatomical reconstruction in shoulder arthroplasty, it is important to understand normal glenohumeral geometry. Unfortunately, however, the details of the glenohumeral joint in Asian populations have not been sufficiently evaluated. There is a racial difference in body size, and this difference probably results in a difference in glenohumeral size.

The purpose of this study was to evaluate three-dimensional geometry of the glenohumeral joint in the normal Asian population and to clarify its morphologic features.

Methods

Anthropometric analysis of the glenohumeral joint was performed using computed tomography scans of 160 normal shoulders from healthy volunteers in age from 20 to 40 years. Using OsiriX MD, Geomagic Studio, and AVIZO software, the dimensions of humeral head width, humeral head diameter, glenoid height, glenoid width, and glenoid diameter were analyzed three-dimensionally (Figure 1). In diameter analyses, the humeral head was assumed to be a sphere and the glenoid was to fit a sphere (Figure 2–3).

Sex differences in height, humeral length, humeral head width, humeral head diameter, glenoid height, glenoid width, and glenoid diameter were compared using Mann-Whitney U tests. The correlations between sides and among the respective parameters in the glenohumeral dimensions were evaluated with Spearman rank correlation tests. The significance level was set at 0.05 for all analyses.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 105 - 105
1 Jan 2016
Onishi Y Ishimaru M Hino K Shiraishi Y Miura H
Full Access

Introduction. MERA Quest Knee System (Quest Knee) is a posterior cruciate ligament–retaining prosthesis considering the anatomical features and lifestyles of the Japanese. As for the anatomical features, we reduced the size of prosthesis and set a smaller interval of sizes because Japanese knees are smaller and flatter than those of Caucasians. As for the lifestyles, we evaluated in vivo patellar tracking during deep knee flexion and the condylar geometry in the axial plane of magnetic resonance imaging. It was found that the patella sank deeply into the intercondylar notch and that the articular surface of the lateral condyle began to curve steeply. We adopted this shape and engraved the lateral condyle deep to reduce the pressure of the patellofemoral joint and to get better range of motion (ROM). For the contact pressure rise in the femorotibial joint by engraving the lateral condyle, the insert was suited to the shape of the femoral component. Furthermore, we increased the thickness of the posterior flange of the femoral component and changed the posterior radius of curvature gradually, and this shape allowed the flexion of 155°. We have used Quest Knee for clinical applications from October 2009. We studied the short-term results of Quest Knee. Methods. Between June 2010 and July 2013, the same senior surgeon performed 59 consecutive primary operations with Quest Knee. Forty patients (44 knees) were women, and 14 patients (15 knees) were men. The mean patient age was 72.5 years (range, 59–89 years). All were osteoarthritis knees. Coronal deformity was varus in 58 knees and valgus in one knee. All operations were performed with a measured resection technique, and all patellae were resurfaced. Clinical evaluations were assessed using the Japanese Orthopaedic Association knee rating score (JOA score), and clinical ROM and standing femorotibial angle (FTA) were measured. Additionally, three-dimensional motion analysis of the patellar component during squatting was performed by the image matching method with image correlations. Results. The mean follow-up period was 17.4 months (range, 6–43 months). The JOA score at preoperative and follow-up were 57.5 ± 10.1 and 87.5 ± 5.6 points, respectively (P < 0.0001) (Fig. 1). The ROM at preoperative and follow-up were 127.4 ± 11.1 and 126.2 ± 9.0° (P = 0.47) (Fig. 2). The mean FTA at preoperative and follow-up were 184.2 and 172.3°. With regard to the three-dimensional motion analysis, the patella showed lateral shift during squatting (Fig. 3). Discussion. As for the patellofemoral contact pressure at flexion in total knee arthroplasty, a biomechanical study has reported that the pressures of posterior cruciate ligament–retaining and posterior-stabilized knees were 3.2 and 2.8 times as much as the body weight. This report suggests that the reduction of the pressure of the patellofemoral joint during deep knee flexion results in better ROM. We suppose that Quest Knee reduced the pressure, led the patella to the lateral side, and achieved better ROM. Conclusions. Short-term results of Quest Knee were good. More detailed studies are needed to get better function and long-term durability


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 564 - 571
1 Apr 2015
Tinney A Thomason P Sangeux M Khot A Graham HK

We report the results of Vulpius transverse gastrocsoleus recession for equinus gait in 26 children with cerebral palsy (CP), using the Gait Profile Score (GPS), Gait Variable Scores (GVS) and movement analysis profile. All children had an equinus deformity on physical examination and equinus gait on three-dimensional gait analysis prior to surgery. The pre-operative and post-operative GPS and GVS were statistically analysed. There were 20 boys and 6 girls in the study cohort with a mean age at surgery of 9.2 years (5.1 to 17.7) and 11.5 years (7.3 to 20.8) at follow-up. Of the 26 children, 14 had spastic diplegia and 12 spastic hemiplegia. Gait function improved for the cohort, confirmed by a decrease in mean GPS from 13.4° pre-operatively to 9.0° final review (p < 0.001). The change was 2.8 times the minimal clinically important difference (MCID). Thus the improvements in gait were both clinically and statistically significant. The transverse gastrocsoleus recession described by Vulpius is an effective procedure for equinus gait in selected children with CP, when there is a fixed contracture of the gastrocnemius and soleus muscles.

Cite this article: Bone Joint J 2015;97-B:564–71.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 53 - 53
1 Jul 2014
Wada H Mishima H Hyodo K Yamazaki M
Full Access

Summary Statement

We used three-dimensional software to assess different anatomic variables in the femur. The canal of Femur twisted slightly below the lesser trochanter in cases with a larger angle of anteversion.

Introduction

Accurate positioning of the joint prosthesis is essential for successful total hip arthroplasty (THA). To aid in tailoring of the prosthesis, we used three-dimensional software to assess different anatomic variables in the femur.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 237 - 241
1 Feb 2014
Miyake J Shimada K Oka K Tanaka H Sugamoto K Yoshikawa H Murase T

We retrospectively assessed the value of identifying impinging osteophytes using dynamic computer simulation of CT scans of the elbow in assisting their arthroscopic removal in patients with osteoarthritis of the elbow. A total of 20 patients were treated (19 men and one woman, mean age 38 years (19 to 55)) and followed for a mean of 25 months (24 to 29). We located the impinging osteophytes dynamically using computerised three-dimensional models of the elbow based on CT data in three positions of flexion of the elbow. These were then removed arthroscopically and a capsular release was performed.

The mean loss of extension improved from 23° (10° to 45°) pre-operatively to 9° (0° to 25°) post-operatively, and the mean flexion improved from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively. The mean Mayo Elbow Performance Score improved from 62 (30 to 85) to 95 (70 to 100) post-operatively. All patients had pain in the elbow pre-operatively which disappeared or decreased post-operatively. According to their Mayo scores, 14 patients had an excellent clinical outcome and six a good outcome; 15 were very satisfied and five were satisfied with their post-operative outcome.

We recommend this technique in the surgical management of patients with osteoarthritis of the elbow.

Cite this article: Bone Joint J 2014;96-B:237–41.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 355 - 355
1 Dec 2013
Ishimaru M Shiraishi Y Hino K Onishi Y Miura H
Full Access

Introduction:

The widespread use of TKA promoted studies on kinematics after TKA, particularly of the femorotibial joint. Knee joint kinematics after TKA, including the range of motion (ROM) and the physical performance, are also influenced by the biomechanical properties of the patella. Surgeons sometimes report complications after TKA involvinganterior knee pain, patellofemoral impingement and instability. However, only few studies have focused specially on the patella. Because the patella bone is small and overlapped with the femoral component on scan images. In addition, the patellar component in TKA is made of x-ray–permeable ultra-high molecular weight polyethylene. It is impossible to radiographically determine the external contour of the patellar component precisely. No methods have been established to date to track the dynamic in vivo trajectory of the patella component. In this study, we analyzed the in vivo three-dimensional kinematics of the patellar component in TKA by applying our image matching method with image correlations.

Methods:

A computed tomography (CT) and an x-ray flat panel detector system (FPD) were used. FPD-derived post-TKA x-ray images of the residual patellar bone were matched by computer simulation with the virtual simulation images created using pre-TKA CT data. For the anatomic location of the patellar component, the positions of the holes drilled for the patellar component pegs were used. This study included three patients with a mean age of 68 years (three females with right knee replacement) who had undergone TKA with the Quest Knee System and achieved a mean passive ROM of 0 to ≥ 130° after 6 or more month post-TKA. We investigated three-dimensional movements of the patellar component in six degrees of freedom (6 DOF) during squatting and kneeling. Furthermore, we simulated the three-dimensional movement of the patellar component, and we estimated and visualized the contact points between the patellar and femoral components on a three-dimensional model.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 448 - 448
1 Dec 2013
Nakata K Kitada M Akiyama K Owaki H Fuji T
Full Access

[Introduction]

Short tapered wedge-shaped cementless (TW) stems have been widely used for several years. The concept of fixation of TW stem is wedge-fit fixation in the proximal metaphysis. Developmental dysplasia of the hip (DDH) has anatomical abnormality, such as excessive femoral anteversion, short femoral neck length, narrow femoral cavity, or proximal-distal mismatching of the femoral canal. Therefore, Mismatching between stem and bone might be occurred in DDH. We evaluated intramedullary matching of short TW stem for DDH by three dimensional (3D) digital template in order to clarify whether mismatching between stem and bone is seen in DDH implanted short TW stem.

[Materials and Methods]

One hundred hips (92 patients) with DDH were performed preoperative simulation for total hip arthroplasty by 3D digital template system (ZedHip: Lexi, Tokyo, Japan). The average age was 63.5 years old. There were 12 males and 80 females. The average bone mass index was 21.5 kg/m2. Femoral canal shape was normal in 71, champagne-flute in 16 and stovepipe in 13 hips. Bone quality was classified into type A in 23, type B in 74 and type C in 3 hips. Preoperative computed tomography data were used for 3D digital template and reconstructed to 3D femoral model. Short TW stem (Taperloc Complete Microplasty: Biomet, Warsaw, IN) model constructed from computer-assisted design was matched to the reconstructed femoral model. Short TW stem model was in principle implanted according to the femoral neck anteversion with neutral alignment (varus and valgus < 2 degrees, flexion and extension < 2 degrees) at the coronal and sagittal plane of the femur. Stem size was determined in order to obtain the largest intramedullary matching at the coronal plane. Area of stem fitting with the cortical bone was investigated at 10 mm intervals above and below of mid minor trochanter. Intramedullary matching pattern was classified into proximal mediolateral metaphyseal fit, proximal flare fit and diaphyseal fit at multiple reconstructed planes of the 3D femoral model according to stem fitting area.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 189 - 189
1 Dec 2013
Verstraete M Luyckx T De Roo K Dewaele W Bellemans J Victor J
Full Access

Purpose

As human soft tissue is anisotropic, non-linear and inhomogeneous, its properties are difficult to characterize. Different methods have been described that are either based on contact or noncontact protocols. In this study, three-dimensional (3D) digital image correlation (DIC) was adopted to examine the mechanical behaviour of the human Achilles tendon. Despite its wide use in engineering research and its great potential for strain and displacement measurements in biological tissue, the reported biomedical applications are rather limited. To our knowledge, no validation of 3D DIC measurement on human tendon tissue exists.

The first goal of this study was to determine the feasibility to evaluate the mechanical properties of the human Achilles tendon under uniaxial loading conditions with 3D Digital Image Correlation. The second goal was to compare the accuracy and reproducibility of the 3D DIC against two linear variable differential transformer (LVDT's).

Methods

Six human Achilles tendon specimens were prepared out of fresh frozen lower limbs. Prior to preparation, all limbs underwent CT-scanning. Using Mimics software, the volume of the tendons and the cross sectional area at each level could be calculated. Subsequently, the Achilles tendons were mounted in a custom made rig for uni-axial loading. Tendons were prepared for 3D DIC measurements with a modified technique that enhanced contrast and improved the optimal resolution. Progressive static loading up to 628,3 N en subsequent unloading was performed. Two charge-coupled device camera's recorded images of each loading position for subsequent strain analysis. Two LVDT's were mounted next to the clamped tendon in order to record the displacement of the grips.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 893 - 899
1 Jul 2013
Diaz-Ledezma C Novack T Marin-Peña O Parvizi J

Orthopaedic surgeons have accepted various radiological signs to be representative of acetabular retroversion, which is the main characteristic of focal over-coverage in patients with femoroacetabular impingement (FAI). Using a validated method for radiological analysis, we assessed the relevance of these signs to predict intra-articular lesions in 93 patients undergoing surgery for FAI. A logistic regression model to predict chondral damage showed that an acetabular retroversion index (ARI) > 20%, a derivative of the well-known cross-over sign, was an independent predictor (p = 0.036). However, ARI was less significant than the Tönnis classification (p = 0.019) and age (p = 0.031) in the same model. ARI was unable to discriminate between grades of chondral lesions, while the type of cam lesion (p = 0.004) and age (p = 0.047) were able to. Other widely recognised signs of acetabular retroversion, such as the ischial spine sign, the posterior wall sign or the cross-over sign were irrelevant according to our analysis. Regardless of its secondary predictive role, an ARI > 20% appears to be the most clinically relevant radiological sign of acetabular retroversion in symptomatic patients with FAI.

Cite this article: Bone Joint J 2013;95-B:893–9.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 782 - 787
1 Jun 2013
Niki Y Takeda Y Udagawa K Enomoto H Toyama Y Suda Y

We investigated the characteristics of patients who achieved Japanese-style deep flexion (seiza-sitting) after total knee replacement (TKR) and measured three-dimensional positioning and the contact positions of the femoral and tibial components. Seiza-sitting was achieved after surgery by 23 patients (29 knees) of a series of 463 TKRs in 341 patients. Pre-operatively most of these patients were capable of seiza-sitting, had a lower body mass index and a favourable attitude towards the Japanese lifestyle (27 of 29 knees). According to two-/three-dimensional image registration analysis in the seiza-sitting position, flexion, varus and internal rotation angles of the tibial component relative to the femoral component had means of 148° (sd 8.0), 1.9° (sd 3.2) and 13.4° (sd 5.9), respectively. Femoral surface contact positions tended to be close to the posterior edge of the tibial polyethylene insert, particularly in the lateral compartment, but only 8.3% (two of 24) of knees showed femoral subluxation over the posterior edge. The mean contact positions of the femoral cam on the tibial post were located 7.8 mm (sd 1.5) proximal to the lowest point of the polyethylene surface and 5.5 mm (sd 0.9) medial to the centre of the post, indicating that the post-cam contact position translated medially during seiza-sitting, but not proximally. Collectively, the seiza-sitting position seems safe against component dislocation, but the risks of posterior edge loading and breakage of the tibial polyethylene post remain.

Cite this article: Bone Joint J 2013;95-B:782–7.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 20 - 20
1 Apr 2013
Jamal B Pillai A Fogg Q Kumar S
Full Access

Introduction

The anatomy of the first metatarsophalangeal (MTP) joint and, in particular, the metatarsosesamoid articulation remains poorly understood. The movements of the sesamoids in relation to the metatarsal plays a key role in the function of the first MTP joint. Although the disorders affecting the sesamoids are described well, the movements of the metatarsosesamoid joints and the pathomechanics of these joints have not been described. We have performed a cadaver study detailing and quantifying the three dimensional movements occurring at these joints.

Methods

Fresh frozen cadaveric specimens without evidence of forefoot deformity were dissected to assess the articulating surfaces throughout a normal range of motion. The dissections were digitally reconstructed in positions ranging from 10 degrees of dorsiflexion to 60 degrees of plantarflexion using a MicroScribe, enabling quantitative analyses in a virtual 3D environment.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 37 - 37
1 Mar 2013
Ul Islam S Dandachli W Richards R Hall-Craggs M Witt J
Full Access

The position of the pelvis has been shown to influence acetabular orientation. However there have been no studies quantifying that effect on the native acetabulum. Our aims were to investigate whether it is possible to quantify the relationship between pelvic tilt and acetabular orientation in native hips, and whether pelvic tilt affects acetabular cover of the femoral head. Computerized tomography scans of 93 hips (36 normal, 31 dysplastic and 26 with acetabular retroversion) were analyzed. We used a CT technique that allows standardised three-dimensional (3D) analysis of acetabular inclination and anteversion and calculation of femoral head cover in relation to the anterior pelvic plane and at different degrees of forward and backward tilt. Acetabular anteversion, inclination and cover of the femoral head were measured at pelvic tilt angles ranging from −20° to 20° in relation to the anterior pelvic plane using 5° increments. The effect of pelvic tilt on version was similar in the normal, dysplastic and retroverted groups, with a drop in anteversion ranging from 2.5° to 5° for every 5° of forward tilt. The effect on inclination was less marked and varied among the three groups. Pelvic tilt increased femoral head cover in both normal and dysplastic hips. The effect was less marked, and tended to be negligible at higher positive tilt angles, in the retroverted group. This study has provided benchmark data on how pelvic tilt affects various acetabular parameters which in turn may be helpful in promoting greater understanding of acetabular abnormalities and how pelvic tilt affects the interpretation of pelvic radiographs