Aim. Orthopedic implants play a tremendous role in fixing bone damages due to aging as well as fractures. However, these implants tend to get colonized by bacteria on the surface, leading to infections and subsequently prevention of healing and osteointegration. Recently, Roupie et al. showed that a nisin layer-by-layer based coating applied on biomaterials has both osteogenic and antibacterial properties. The Galleria mellonella larva is a well-known insect infection model that has been used to test the virulence of bacterial and fungal strains as well as for the high throughput screening of antimicrobial compounds against infections. Recently, we have developed an insect infection model with G. mellonella larvae to study implant-associated biofilm infections using Kirschner (K)-wires as implant material. Here, we would like to test the antibacterial capacity of nisin layer-by-layer based coatings on K-wires against Staphylococcus aureus in the G. mellonella larva implant infection model. Method. Prior to the implantation procedure, G. mellonella larvae are maintained at room temperature on wheat germ in an incubator. The larvae received bare titanium K-wires (uncoated), or either control-coated or nisin-coated K-wires. After one hour, the larvae were injected with 5×10. 5. S. aureus bacteria per larva (i.e., hematogenous implant infection model). Next, the larvae were incubated at 37. o. C in an incubator and the
Aim. Periprosthetic joint infection (PJI) and periprosthetic fracture (PF) are one of the most devastating complications in arthroplasty. Each complication by itself is challenging to solve. Yet, simultaneously, both complications are inconceivably complex to deal with, while the treatment regimen of PJI and PF are contradictory. Chronic PJI most often requires implant removal, while PF requires stability, regularly achieved by stable osteosynthesis. This study aims to (1) analyse the success rate of PJI with following concomitant PF during the treatment course in total hip arthroplasties (THA) and (2) to determine the risk factors for reinfection and subsequent revision surgery after treatment of PJI and PF. Method. This restrospective study analyzed 41 patients with concomitant PJI and PF during the PJI treatment period from 2013 to 2022 involving THA. Patients were divided in two cohorts termed success and failure and were statistically compared. The median follow-up time was 66 months (>12 months). All patients were considered individually and treated according to their individual needs in fracture and infection treatment. Re-arthroplasty
Background. Postoperative dislocation is one of the main surgical complications and the primary cause for revision surgery after 2-stage implant exchange due to periprosthetic infection of a total hip arthroplasty. Objective. The aims of our study were (1) to determine the incidence of dislocation after two-stage THA reimplantation without spacer placement, (2) to evaluate relevant risk factors for dislocation and (3) to assess the final functional outcome of those patients. Method. We prospectively analyzed 187 patients who underwent a two-stage total hip arthroplasty (THA) revision after being diagnosed with periprosthetic joint infection (PJI) from 2013 to 2019. The mean duration of follow-up was 54.2 ± 24.9 months (>36 months). The incidence of postoperative dislocation and subsequent revision was estimated through Kaplan-Meier curves and potential risk factors were identified using Cox hazard regression. The functional outcome of the patients was assessed using the modified Harris Hip Score (mHHS). Results. The estimated cumulative dislocation-free
Aim. To report outcomes of soft tissue reconstruction using free tissue transfer for the treatment of tibial osteomyelitis as part of a single-stage, ortho-plastic procedure. Method. Patients who underwent ortho-plastic reconstructive surgery to excise tibial osteomyelitis in combination with free tissue transfer in one stage were included. Patients underwent surgery between 2015 and 2024 in a single specialist centre within the UK. Baseline patient information, demographics, and infection information was recorded. Adverse outcomes were defined as (i) flap salvage required, (ii) flap failure and (iii) recurrence of infection. Patient reported quality of life was measured using the EuroQol EQ-5D-5L index score. Pre-operative QoL was compared to QoL at 1 year with a control group of 53 similar patients who underwent surgical treatment for tibial osteomyelitis without a free flap (local flap or primary closure). Results. Ninety-three patients were eligible for inclusion, with a mean age of 52 years (range 18–90). 77/93 (82.8%) had a free muscle flap with the remainder (17.2%) receiving a fasciocutaneous flap. The donor tissue was defined as 57 gracilis, 6 latissimus dorsi, 14 hemi-latissimus dorsi, and 16 anterolateral thigh. The recipient area of the tibia was distal 1/3 in 52 cases, middle 1/3 in 27 cases and proximal 1/3 in 12 cases. The average flap ischaemic time was 70 minutes (range 28 to 125). Seven patients (7.5%) required urgent flap salvage at a median time of 1.0 day (range 0.5 – 4.0). Of these, 4 (4.3%) went on to have total flap failure, of which 2 patients underwent below knee amputation subsequently. Flap failure was due to either arterial (n=2) or venous (n=2) anastomotic thrombus. There were 3 (3.2%) episodes of confirmed infection recurrence within the first year after the index procedure. EQ-index scores at 1-year post-operatively were significantly improved when compared to pre-operative scores (p=0.008). At 1-year post-operatively, EQ-index scores in patients who underwent free flap was similar compared to local flaps (p=0.410) and in those who underwent primary closure for tibial osteomyelitis (p=0.070). Conclusions. Microsurgical single stage surgery can achieve high flap
Aim. In trauma surgery, the development of biomaterial-associated infections (BAI) is one of the most common complications affecting trauma patients, requiring prolonged hospitalization and the intensive use of antibiotics. Following the attachment of bacteria on the surface of the biomaterial, the biofilm-forming bacteria could initiate a chronic implant-related infection. Despite the use of conventional local and systemic antibiotic therapies, persistent biofilms involve various resistance mechanisms that contribute to therapeutic failures. The development of in vivo chronic BAI models to optimize antibiofilm treatments is a major challenge. Indeed, the biofilm pathogenicity and the host response need to be finely regulated, and compatible with the animal lifestyle. Previously, a Galleria mellonella larvae model for the formation of an early-stage biofilm on the surface of a Kirschner (K)-wire was established. In the present study, two models of mature biofilm using clinical Staphylococcus aureus strains were assessed: one related to contaminated K-wires (in vitro biofilm maturation) and the second to hematogenous infections (in vivo biofilm maturation). Rifampicin was used as a standard drug for antibiofilm treatment. Method. In the first model, biofilms were formed following an incubation period (up to 7 days) in the CDC Biofilm Reactor (CBR, BioSurface Technologies). Then, after implantation of the pre-incubated K-wire in the larvae, rifampicin (80 mg/kg) was injected and the
Aim. In Two-Stage Revision, utilizing temporary antibiotic spacers is widely accepted. These spacers are available prefabricated or can be individually moulded intraoperatively. In this study, we analysed the efficacy of prefabricated and individual spacers in infection eradication of periprosthetic joint infection in knee and hip arthroplasties. Method. All spacers implanted at a tertiary academic center during two-stage exchanges between June 2010 and December 2019 were retrospectively analysed. Among 249 patients, 167 cases (minimum follow-up ≥ 12 months) were included. Commercial spacers contained vancomycin and gentamycin, while individual spacers contained vancomycin alone. Subgroup analysis by manufacturers was conducted using non-parametric methods including Mann-Whitney U and Kruskal-Wallis tests.
Aim. There is controversy regarding the use of Antibiotic-loaded cement (ALBC) as compared to non-antibiotic-loaded cement (NALBC) to reduce the overall infection rate without affecting implant
In recent years, many studies demonstrated the efficacy of an early switch to oral antibiotics after surgical treatment in orthopaedic related infections. However, large analyses on periprosthetic joint infections (PJIs) are lacking. We conducted a retrospective observational multicenter study in patients diagnosed with an early postoperative PJI (i.e less than 3 months after the index arthroplasty) treated with debridement, antibiotics and implant retention (DAIR). Patients from Europe and the USA were included. These two cohorts served as a quasi-randomised trial since an early oral antibiotic switch is routine practice in Europe versus a long duration of intravenous (IV) antibiotic treatment in the USA. Failure was defined as the clinical need for: i) a second DAIR, ii) implant removal, iii) suppressive antibiotic treatment or iv) infection related death.Introduction
Material and Methods
The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents. We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.Aims
Methods
Introduction. When designing a new osteosynthesis device, the biomechanical competence must be evaluated with respect to the acting loads. In a previous study, the loads on the proximal phalanx during rehabilitation exercises were calculated. This study aimed to assess the safety of a novel customizable osteosynthesis device compared to those loads to determine when failure would occur. Method. Forty proximal phalanges were dissected from skeletally mature female sheep and divided into four testing groups. A custom 3D printed cutting and drilling guide was used to create a reduced osteotomy and pilot holes to insert four 1.5 mm cortical screws. A novel light-curable polymer composite was used to fixate the bones with an in situ fixation patch. The constructs were tested in cyclic four-point bending in a bioreactor with ringer solution at 37°C with a valley load of 2 N. Four groups (N = 10) had increasing peak loads based on varying safety factors relative to the physiological loading (G1:100x, G2:150x, G3:175x, G4:250x). Each specimen was tested for 12,600 cycles (6 weeks of rehabilitation) or until failure occurred. After the test the thickness of the patch was measured with digital calipers and data analysis was performed in Python and R. Result. All samples survived in G1, and all failed in G4. G2 and G3 had 1 and 8 failures, respectively. There was no significant difference in patch thickness in all survivor samples against failures (p = 0.131), however, there was a significant difference in the displacement amplitude in the final cycle (0.072 mm vs. 0.15 mm; p < 0.001). Conclusion. This study found the
Introduction. Symptomatic hip dysplasia is often treated with periacetabular osteotomy (PAO). Studies investigating the effect of PAO have primarily focused on radiographic measurements, pain-related outcomes, and hip
Introduction. Diabetes mellitus type 2 (DMT2) patients often develop Achilles tendon (AS) degeneration. The ZDF rat model is often used to study DMT2. Hence, this study investigated whether tenocytes isolated from diabetic and non diabetic ZDF rats respond differentially to normo- (NG) and hyperglycemic (HG) conditions in the presence of tumor necrosis (TNF)α. Method. AS tenocytes isolated from adult diabetic (fa/fa) or lean (fa/+) Zucker Diabetic Fatty (ZDF) rats were treated with 10 ng/mL TNFα either under NG or HG conditions (1 g/L versus 4.5 g/L glucose). Tendons were characterized histopathologically using Movin score. Tenocyte
Introduction. Vascularized fibular grafting following tumor resection is an essential treatment option in limb salvage surgery. This study aimed to assess the surgical and oncological outcomes of patients treated in Denmark between 2010 and 2022. Method. We present a retrospective review of a national cohort comprising 27 patients. The indications were 13 cases of Ewing sarcoma, 12 cases of osteosarcoma, and 2 cases of giant cell tumor. The median age at surgery was 16 years (range: 2-39), and the median follow-up was 82 months (range: 12-138). Patients were analyzed overall and stratified into upper and lower extremity groups based on tumor location. Result. The primary rate of graft union was 63%, and after secondary procedures, the overall rate of graft union was 67%, with a median time to union of 13 months (range: 7-29). The reoperation rate was 74%, while the rate of limb salvage was 93%, with two patients undergoing amputation during follow-up. The 5-year overall
Introduction. Most western countries have implemented fast-track hip fracture aiming at surgery within 24 hours, since the mortality rate hereafter rises markedly. In Greenland, it is not achievable to operate within 24 hours. Arctic people live in sparsely populated areas and Greenland's population is scattered along the vast coastline. All patients must be chartered to Nuuk by airplane which can take up till several days to weeks, due to logistics and the Arctic weather. This presents a challenge regarding adhering to western guidelines. The operative delay may be acceptable though, as it is the impression that the Greenlandic population survives and endures better than patients of western populations. However, as data are lacking, we aimed to describe mortality among hip fracture patients in Greenland taking frailty and comorbidities into account. Method. All patients with ICD-10 codes DS720, DS721 and DS722 from 2018-2022 were identified as 261 patients diagnosed with hip fractures. Variables including time of diagnosis, time to operation, reasons for delay, ASA-score, Charlson Comorbidity index, time of death, and other possible confounding variables were analyzed. Primary outcome was mortality rates at 30-day post-OP and 1-year post-OP. Results. The average time from fracture to operation was 91.4 hours. In the Danish Cohort (DC) 70,6 % of patient were operated within 24 hours. Overall, 30-day mortality was 9,9 %, and 1-year mortality was 29,4 %, compared to the DC with 10,8 % 30-day mortality and 28,3 % 1-year mortality. Multivariate regression was conducted, showing no statiscal significant increase in mortality, despite extended delay. Conclusion. With no increase in death, the authors find it justifiable that patients in Greenland endure longer delays than the western population. The influence on further adverse effects needs to be investigated as well as causes of
Aims. For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. Methods. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan. Results. Postoperative pathological assessment revealed a negative surgical margin was achieved in all patients. At final follow-up, 13.3% (2/15) died and no recurrence occurred. The overall
Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group. The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up.Aims
Methods
The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against We performed in vitro growth and viability assays to determine the capability of Aims
Methods
While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes. This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected.Aims
Methods
Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion. When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically,
Understanding spinopelvic mechanics is important for the success of total hip arthroplasty (THA). Despite significant advancements in appreciating spinopelvic balance, numerous challenges remain. It is crucial to recognize the individual variability and postoperative changes in spinopelvic parameters and their consequential impact on prosthetic component positioning to mitigate the risk of dislocation and enhance postoperative outcomes. This review describes the integration of advanced diagnostic approaches, enhanced technology, implant considerations, and surgical planning, all tailored to the unique anatomy and biomechanics of each patient. It underscores the importance of accurately predicting postoperative spinopelvic mechanics, selecting suitable imaging techniques, establishing a consistent nomenclature for spinopelvic stiffness, and considering implant-specific strategies. Furthermore, it highlights the potential of artificial intelligence to personalize care. Cite this article: