Bone & Joint Research
Vol. 13, Issue 10 | Pages 611 - 621
24 Oct 2024
Wan Q Han Q Liu Y Chen H Zhang A Zhao X Wang J

Aims

This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture.

Methods

Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.


Bone & Joint Research
Vol. 11, Issue 10 | Pages 739 - 750
4 Oct 2022
Shu L Abe N Li S Sugita N

Aims

To fully quantify the effect of posterior tibial slope (PTS) angles on joint kinematics and contact mechanics of intact and anterior cruciate ligament-deficient (ACLD) knees during the gait cycle.

Methods

In this controlled laboratory study, we developed an original multiscale subject-specific finite element musculoskeletal framework model and integrated it with the tibiofemoral and patellofemoral joints with high-fidelity joint motion representations, to investigate the effects of 2.5° increases in PTS angles on joint dynamics and contact mechanics during the gait cycle.


Bone & Joint Open
Vol. 3, Issue 1 | Pages 20 - 28
10 Jan 2022
Fujii H Hayama T Abe T Takahashi M Amagami A Matsushita Y Otani T Saito M

Aims

Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population.

Methods

This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 40 - 40
1 May 2018
Del-Valle-Mojica J Alonso-Rasgado T Bailey C Jimenez-Cruz D Board T
Full Access

Introduction. The use of larger femoral heads in Total Hip Arthroplasty has increased in order to reduce the risk of dislocation and to improve the range of motion of the joint. In 2003, within the UK, the “standard” head size of 28mm was used in 73% of all hip procedures, whereas by 2012, this figure dropped to 36%. Concerns regarding the impact of this increment in head size on the cement and bone stresses have arisen; however, this has yet to be clearly determined. Methods. To understand the relationship between femoral head size and cement mantle and bone stress in cemented hip arthroplasty, 3D-Finite-Element models of a hemipelvis with cemented cup[tb6] (50mm outer-diameter) were developed. Loading conditions of single-leg-stance (average and overweight) were simulated for three head sizes (28, 32 and 36mm). The models were validated with an in-vitro experiment using the average loading condition. Results. Stresses were evaluated at the periacetabular bone and cement mantle. In the pelvic bone the peak von Mises stress value presented no change in magnitude due to change in head size for the average patient; for the overweight patient, there was a small increment. In the cement mantle, there was a noticeable difference in the pattern distribution and magnitude of the stresses for the two loading conditions[tb7]. For the average patient, average stresses in the cement were 1.7MPa, 1.8MPa and 1.9MPa for 28, 32 and 36mm heads, respectively; whereas for the overweight patient the stresses were 3.4MPa, 3.6MPa and 3.8MPa. Conclusions. Pelvic bone remained largely unaffected by the changes in femoral head size. The major effect of femoral head size occurs in the stress level and stress distribution pattern in the cement mantle. The current predicted cement stresses are below the cement endurance limit, this indicates that the cement fatigue life is not affected by the increasing head size


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 17 - 17
1 Apr 2018
Lee J
Full Access

Purpose. The purpose of this study is to report the results of the first 1000 cases hip arthroplasty using the Bencox. ®. hip stem, the first hip prosthesis developed and manufactured in Korea. Material & Method. This study reviewed 1000 cases retrospectively who underwent arthroplasty using Bencox. ®. hip system. The Bencox. ®. hip stem is the first hip prosthesis developed and manufactured in Korea. This stem have a double-tapered, wedge shape figure with a rectangular-shaped cross-section and specially designed neck shape, which is design to achieve normal stress pattern of the proximal femur and to increase initial stability and to increase range of motion. Surface is treated with MAO (Micro Arc Oxidation) coating. From the first arthroplasty with this system in September 2006, sequentially 1000 arthroplasties were performed by single surgeon until the July 2014. This material included 439 men and 561 female. Average age of patients was 65 year old. Follow up period was average 72.1 month (minimum 34 months to maximum 120 months). 1000 cases consisted of 569 hips in patients with femoral neck or intertrochanteric fracture or subtrochanteric fracture (fracture group), 155 hips in osteoarthritis, 192 hips in patients with osteonecrosis of the femoral head (arthritis group), 84 hips in revision surgery (revision group). Revision cases consisted of 58 hips with aseptic loosening and 26 hips with loosening due to infection sequelae. They were underwent hip arthroplasty using a Bencox. ®. hip stem in combination with Bencox. ®. bipolar cup and Bencox. ®. acetabular cup. Patients in the fracture group usually underwent bipolar hip arthroplasty, and those in the arthritis group and revision group underwent total hip arthroplasty. They were reviewed by medical records, clinically and radiologically. Results. During the follow-up period, there were no cases of revision of the femoral stem. Radiographically, there were no cases of radiolucent line except very proximal part of the stem endosteal bone ongrowth was found in most cases. Postoperative complications such as stem loosening, infection, dislocation, and ceramic breakage were not noted. But periprosthetic fracture was encountered in 7 hips due to slip down. They were treated by open reduction and internal fixation with plate and cables. There were no cases of failure of these treatments. Conclusion. Clinical and radiographic evaluations of hip arthroplasty using the Bencox. ®. hip system showed excellent outcomes with average 72.1 month follow-up in 1000 case


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 95 - 95
1 Apr 2018
Polak-Kraśna K MacLeod A Fletcher J Whitehouse M Preatoni E Gill H
Full Access

The screw fastening torque applied during bone fracture fixation has a decisive influence on subsequent bone healing. Insufficient screw tightness can result in device/construct instability; conversely, excessive torques risk damaging the bone causing premature fixation failure. This effect is even more prominent in osteoporotic bone, a condition associated annually with almost 9 million fractures worldwide. During fracture fixation, screw tightening torque is applied using subjective feel. This approach may not be optimal for patient”s recovery, increasing risk of fixation failure, particularly in osteoporotic bone, and potentially require revision surgical interventions. Besides bone density, various factors influence the performance of screw fixation. These factors include bone geometry, cortical thickness and time-dependant relaxation behaviour of the bone. If the influence of screw fastening torque on the bone and relationships between these factors was better understood, the surgical technique could be optimised to reduce the risk of complications. Within this study, we developed an axisymmetric finite element (FE) model of bone screw tightening incorporating viscoelastic behaviour of the cortical bone such as creep and stress relaxation. The model anticipated time-dependent behaviour of the bone for different bone thickness and density after a typical bone fixation screw had been inserted. The idealised model has been developed based on CT scans of bones with varying densities and inserted screws. The model was validated through a series of experiments involving bovine tibiae (4–5 months) to evaluate the evolution of surface strains with time (Ncorr v1.2). Stress distribution was assessed in photoelastic experiments using acrylic analogues. Relaxation tests have been performed in aqueous environment for up to 48 hours to ensure the relaxation would be complete. The creep behaviour (maximum principal strain) was compared against computational predictions. Our early simulations predicted relaxation strains on the surface of the bone to be 1.1% within 24 hours comparing favourably to 1.3% measured experimentally. Stress distribution patterns were in agreement with photoelastic results. Using experimentally derived viscoelastic properties, the model has the potential to predict creep and stress relaxation patterns after screw insertion with different fastening torques for bones with varying density and geometry. We aim to develop this into a planning tool providing guidance to surgeons for optimal tightening when using screw fixation, particularly in reduced quality bone


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 75 - 75
1 May 2017
Koris J Blunn G Coathup M
Full Access

Background. Children suffering from primary bone cancer necessitating resection of growth plates, may suffer progressive leg length discrepancy, which can be attenuated with extendable prostheses. A serious complication is catastrophic implant failure. Over time, bone will remodel, altering the stress pattern in the implant. By using finite element analysis we can model different bone remodeling conditions to ascertain the effect that this will have on stress distribution and magnitude. A finite element analysis was performed. Simplified computer generated models were designed of a cemented femoral Stanmore growing massive endoprosthesis. Three scenarios were designed, modelled on post-operative radiographs. Scenario 1 had a gap between the end of the femur and the implant collar, scenario 2 had no gap, but with no bone attachment into the collar, and scenario 3 had growth of the bone over the length of the collar with attachment. Physiological loading conditions were applied. The resultant stress in the implant for each scenario was measured, and compared to the strength of the material. Peak stresses were recorded at the stem-collar junction. The maximum stress recorded in the implant in scenario 1 was 3104.2Mpa, compared to 1054.4Mpa in scenario 2, and 321.2Mpa in scenario 3. Conclusions. Both accurate reduction and bone growth with attachment to the stem of a massive endoprosthesis will greatly reduce the resultant stress in the implant under loading conditions. The load is redistributed throughout the length of the bone. This may help to prevent catastrophic failure in the implant under loading conditions. Further investigations of patient findings are needed to ensure the model findings are verified. Level of Evidence. IIb (Theoretical)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 100 - 100
1 Mar 2017
Gabaran N Mirghasemi S Rashidinia S Sadeghi M Talebizadeh M
Full Access

Background

Surgical reconstruction of the anterior cruciate ligament is a common practice to treat the disability or chronic instability of the knee. Several factors associated with success or failure of the ACL reconstruction, including surgical technique and graft material and graft tension. We aimed to show how we can optimize the graft properties and achieve better post surgical outcomes during ACL reconstruction using 3-dimensional computational finite element simulation.

Methods

In this paper, 3-dimensional model of the knee was constructed to investigate the effect of graft tensioning on the knee joint biomechanics. Four different grafts were compared: 1) bone-patellar tendon-bone graft (BPTB) 2) Hamstring tendon 3) BPTB and a band of gracilis 4) Hamstring and a band of gracilis. The initial graft tension was set as “0, 20, 40, or 60N”. The anterior loading was set to 134 N.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 14 - 14
1 Feb 2017
Higa M Manabe T Nakamura Y Tanino H
Full Access

Introduction. Although total hip arthroplasty (THA) has been one of the most successful, reliable and common prosthetic techniques since the introduction of cemented low-friction arthroplasty by Charnley in the early 1960s, aseptic loosening due to stem-cement and cement-bone interface failures as well as cement fractures have been known to occur. To overcome this loosening, the stem should be mechanically retentive and stable for long term repetitive loading. Migration studies have shown that all stems migrate within their cement mantle, sometimes leading to the stem being debonded from the cement [1]. If we adopt the hypothesis that the stems debond from the cement mantle, the stem surface should be polished. For the polished stem, the concept of a double taper design, which is tapered in the anteroposterior (AP) and mediolateral (ML) planes, and a triple-tapered design, which has trapezoidal cross-section with the double tapered, have been popularized. Both concepts performed equally well clinically [2]. In this study, we aimed to analyze stress patterns for both models in detail using the finite element (FE) method. Methods. An ideal cemented stem with bone was made using three dimensional FE analyses (ANSYS 13). The cortical bone was 105 mm long and 7 mm thick and the PMMA cement mantle was 5 mm in thickness surrounding the stem. Young's modulus was set at 200 GPa for the bone and 2.2 GPa for the cement. Poisson's ratio was 0.3 for both materials. The bone-cement interface was completely bonded and cement-stem interface was not bonded in cases where a polished stem surface was used. The two types of stems were compared. One being the double tapered (Fig 1 left) and the other the triple tapered (Fig 1 right). The coefficient of friction (μ) at the stem-cement interface was set at 0 for both models. The distal ends of the stems were not capsulated by the PMMA and therefore the stems were free to subside. All materials were assumed to be linearly isotropic and homogeneous. The distal ends of the bone were completely constrained against any movements and rotations. An axial load of 1200 N and a transverse load of 600 N were applied at the same time simulating the bending condition [3]. Results. Although the stress distribution differences between the designs were minor, the positions where higher stresses and absolute values in the cement were observed varied. For double tapered model, the highest maximum principal stress was 1.98 MPa observed around the corner of the stem at the proximal region. For the triple tapered model, the highest maximum principal stress was 1.67 MPa observed at more medial side than the double tapered model


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 79 - 79
1 Jan 2017
Zaffagnini S Signorelli C Bontempi M Bragonzoni L Raggi F Marchiori G Lopomo N Marcacci M
Full Access

Anterior cruciate ligament (acl) reconstruction is one of the most commonly performed procedures in orthopedics for acl injury. While literature suggest short-term good-to-excellent functional results, a significant number of long-term studies report unexplained early oa development, regardless type of reconstruction. The present study reports the feasibility analysis and development of a clinical protocol, integrating different methodologies, able to determine which acl reconstruction technique could have the best chance to prevent oa. It gives also clinicians an effective tool to minimize the incidence of early oa. A prospective clinical trial was defined to evaluate clinical outcome, biochemical changes in cartilage, biomechanical parameters and possible development of oa. The most common reconstruction techniques were selected for this study, including hamstring single-bundle, single-bundle with extraarticular tenodesis and anatomical double-bundle. Power analysis was performed in terms of changes at cartilage level measurable by mri with t2 mapping. A sample size of 42 patients with isolated traumatic acl injury were therefore identified, considering a possible 10% to follow-up. Subjects presenting skeletal immaturity, degenerative tear of acl, other potential risk factors of oa and previous knee surgery were excluded. Included patients were randomized and underwent one of the 3 specified reconstruction techniques. The patients were evaluated pre-operatively, intra-operatively and post-operatively at 4 and 18 months of follow-up. Clinical evaluation were performed at each time using subjective scores (koos) and generic health status (sf-12). The activity level were documented (marx) as well as objective function (ikdc). Preliminary results allow to verify kinematic patterns during active tasks, including level walking, stair descending and squatting using dynamic roentgen sterephotogrammetric analysis (rsa) methodology before and after the injured ligament reconstruction. Intra-operative kinematics was also available by using a dedicated navigation system, thus to verify knee laxity at the time of surgery. Additionally, non-invasive assessment was possible both before the reconstruction and during the whole follow-up period by using inertial sensors. Integrating 3d models with kinematic data, estimation of contact areas of stress patterns on cartilage was also possible. The presented integrate protocol allowed to acquired different types of information concerning clinical assessment, biochemical changes in cartilage and biomechanical parameters to identify which acl reconstruction could present the most chondroprotective behavior. Preliminary data showed all the potential of the proposed workflow. The study is on-going and final results will be shortly provided


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 4 - 4
1 Jan 2016
Yang X Chen W Yu S Zhang Y Luo G Wang H Sheng P
Full Access

Objective. To investigate the biomechanical basis and report preliminary clinical efficacy of eccentric rotational acetabular osteotomy (ERAO) when treating developmental dysplasia of the hip (DDH). Methods. Biomechanical model of the hip joint was established on cadaveric hips. After performed ERAO on the biomechanical model, we explored the impact of this surgery on biomechanics of the hip joint. Meanwhile, we reported postoperative follow-up cases who underwent ERAO in our hospital between November 2007 to July 2012. A total of 14 patients (15 hips) were reported, including 4 males and 10 females, mean age was 30 years old. Harris hip score was defined as clinical evaluation standard and radiographic assessment was based on the measurement and further comparison of pre- and post-operative AHI (Acetabular-head index), CE angle (Center-edge angle) and Sharp angle. Results. The established biomechanical model was accord with the physiological state of normal hip joint. Postoperative stress was not statistically significant compared with the preoperative stress. Meanwhile, by the end of follow-up, 13 patients (14 hips) were followed for an average time of 26 months, thus, the follow-up rate was 92.9%. Harris hip score improved from preoperative (67.1 ± 8.7) points to (88.1 ± 7.3) points; postoperative AHI increased an average of 39.6%, CE angle increased an average of 33.2 ° and sharp angle reduced an average of 9.6 °. Conclusions. Both biomechanical study and preliminary clinical observation show that ERAO has the ability to correct the deformity of acetabulum. It enlarges the acetabular coverage of the femoral head and thus corrects the abnormal stress pattern. No bone graft is needed during the operation and postoperative rehabilitation is short, therefore, ERAO may have good curative effect when treating the DDH


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 85 - 85
1 Jan 2016
Goh S Chua K Chong D Yew A Lo NN
Full Access

Introduction. Total hip replacement is an established surgical procedure done to alleviate hip pain due to joint diseases. However, this procedure is avoided in yonger patients with higher functional demands due to the potential for early failure. An ideal prosthesis will have have a high endurance against impact loading, with minimal micromotion at the bone cement interface, and a reduced risk of fatigue failure, with a favourable stress distribution pattern in the femur. We study the effect of varying the material properties and design element in a standard cemented total hip using Finite Element Analysis. Methods. A patient-specific 3D model of femur will be constructed from CT scan data, while a Summit® Cemented Hip System (DePuy Orthopedic) will be used to as a control for comparative evaluation. We vary the material stiffness of different parts of the prosthesis(see Fig.1) to formulate a design concept for a new total hip prosthesis design; and use Finite Element Method to predict the micromotion of the hip prosthesis at the bone cement interface, as well as the stress distribution in the the femur. Result. Validation of computational protocol was being done by comparing the principal maximum strain of the femoral cortex along the diaphysis, and the amount of deflection, with published literature, similarly, contact modelling validation was also done. Model 1–4 induced lower peak Von Mises stress in the cement, which takes a much lower value than any of the cement mechanical limits postulated. Therefore, the risk of cement failure is greatly reduced in Model 1–4. However, the effect of varying stiffness in different regions is not significant in terms of load transmission to the cement. Micromotion at the bone-cement interface was studied via two approaches: Peak micromotion at the bone cement interface; and the micromotion data at 12 Regions of Interest (ROI)s. Both results showed that model 2 and 3 are capable of reducing micromotion at bone-cement interface, in comparison with the Summit® Cemented Hip System. By comparing the Von Mises Stress distribution in the proximal femur; model 1 is found to result in a significantly reduced stress shielding effect, while model 2–4 are also favourable in comparison to the standard Summit® prosthesis in terms of stress distribution in the femur. Figure 2 shows the effects of the performance of model 1–4, presented as percentage difference from the Summit® prosthesis. Model 1 is unfavourable, despite its favourable stress distribution, because its peak and overall micromotion at the bone-cement interface is greatly increased. Conclusion. Model 2 and 3 have favourable design elements. They both have reduced micromotion at the bone-cement interface; and a favourable stress distribution in the femur. Further refining and testing of model 2 and 3 should done, as these models may provide information which may be useful in improving the performance of the current range of total hip replacement prostheses


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1332 - 1338
1 Oct 2013
Van Der Straeten C Van Quickenborne D De Roest B Calistri A Victor J De Smet K

A retrospective study was conducted to investigate the changes in metal ion levels in a consecutive series of Birmingham Hip Resurfacings (BHRs) at a minimum ten-year follow-up. We reviewed 250 BHRs implanted in 232 patients between 1998 and 2001. Implant survival, clinical outcome (Harris hip score), radiographs and serum chromium (Cr) and cobalt (Co) ion levels were assessed.

Of 232 patients, 18 were dead (five bilateral BHRs), 15 lost to follow-up and ten had been revised. The remaining 202 BHRs in 190 patients (136 men and 54 women; mean age at surgery 50.5 years (17 to 76)) were evaluated at a minimum follow-up of ten years (mean 10.8 years (10 to 13.6)). The overall implant survival at 13.2 years was 92.4% (95% confidence interval 90.8 to 94.0). The mean Harris hip score was 97.7 (median 100; 65 to 100). Median and mean ion levels were low for unilateral resurfacings (Cr: median 1.3 µg/l, mean 1.95 µg/l (< 0.5 to 16.2); Co: median 1.0 µg/l, mean 1.62 µg/l (< 0.5 to 17.3)) and bilateral resurfacings (Cr: median 3.2 µg/l, mean 3.46 µg/l (< 0.5 to 10.0); Co: median 2.3 µg/l, mean 2.66 µg/l (< 0.5 to 9.5)). In 80 unilateral BHRs with sequential ion measurements, Cr and Co levels were found to decrease significantly (p < 0.001) from the initial assessment at a median of six years (4 to 8) to the last assessment at a median of 11 years (9 to 13), with a mean reduction of 1.24 µg/l for Cr and 0.88 µg/l for Co. Three female patients had a > 2.5 µg/l increase of Co ions, associated with head sizes ≤ 50 mm, clinical symptoms and osteolysis. Overall, there was no significant difference in change of ion levels between genders (Cr, p = 0.845; Co, p = 0.310) or component sizes (Cr, p = 0.505; Co, p = 0.370). Higher acetabular component inclination angles correlated with greater change in ion levels (Cr, p = 0.013; Co, p = 0.002). Patients with increased ion levels had lower Harris hip scores (p = 0.038).

In conclusion, in well-functioning BHRs the metal ion levels decreased significantly at ten years. An increase > 2.5 µg/l was associated with poor function.

Cite this article: Bone Joint J 2013;95-B:1332–8.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 164 - 164
1 Mar 2013
Devadasan B Asgari S Mansor S Hamouda A Singh H
Full Access

Stress shielding of the proximal femur occurs in stemmed implants. Resurfacing implant does not invade the intramedullary region. We studied the stress patterns in conventional and nonstemmed designs. Methods. FE model geometry was based on standard femur from the international Society of Biomechanics Mesh Repository. Loading simulated for one- legged stance with body weight of 826 N. 2 regions were defined, R1 (40 mm from tip of head) and R2 41 mm–150 mm) of the intramedullary part of the stemmed model's interface with bone. 2 different loading conditions bending and torsion were compared for stress and strain. The FE model was solved with ANSYS version 6.1 on a single processor NT station. Results. With conventional implants, stem shields cortical bone from being loaded. In nonstemmed implants, Von Misses stress contours show a similar distribution as intact bone, transferring loads to the cortical shell but with higher stresses and a maximum displacement of 17.39% higher than that of intact bone. 15–23 mm proximal to R2 and around 110 mm, region of the stem tip, there were higher stress and strain concentrations. Conclusion. Based on simulations, nonstemmed implants provide more physiological loading compared to conventional implants though stress shielding increases in region of the stem in resurfacing implant


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 16 - 16
1 Jul 2012
White J Ahir S Hua J
Full Access

Hip resurfacing arthroplasty is emerging as an increasingly popular, conservative option for the treatment of end-stage osteoarthritis in the young and active patient. Despite the encouraging clinical results of hip resurfacing, aseptic loosening and femoral neck fracture remains concerns for the success of this procedure. This study used finite element analysis (FEA) to analyse the stresses within proximal femoral bone resulting from implantation with a conservative hip prosthesis. FEA is a computational method used to analyse the performance of real-world structures through the development of simplified computational models using essential features. The aim of this study was to examine the correlation between the orientation of the femoral component of a hip resurfacing prosthesis (using the Birmingham Hip Resurfacing as a model) and outcomes during both walking and stair climbing. The outcomes of interest were stresses in the femoral neck predisposing to fracture, and bone remodelling within the proximal femur. Multiple three-dimensional finite element models of a resurfaced femur were generated, with stem-shaft angles representing anatomic (135°), valgus (145°), and varus (125°) angulations. Applied loading conditions included normal walking and stair climbing. Bone remodelling was assessed in both the medial and lateral cortices. Analyses revealed that amongst all orientations, valgus positioning produced the most physiological stress patterns within these regions, thereby encouraging bone growth. Stress concentration was observed in cortical and cancellous bone regions adjacent to the rim of the prosthesis. As one would expect, stair climbing produced consistently higher stress than walking. The highest stress values occurred in the varus-orientated femur during both walking and stair climbing, whilst anatomic angulation resulted in the lowest stress values of all implanted femurs in comparison to the intact femur. This study has shown through the use of FEA that optimising the stem-shaft angle towards a valgus orientation is recommended when implanting a hip resurfacing arthroplasty. This positioning produces physiological stress patterns within the proximal femur that are conducive to bone growth, thus reducing the risk of femoral neck fracture associated with conservative hip arthroplasty


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 427 - 427
1 Nov 2011
Takemoto R Arno S Kinariwala N Chan K Hennessy D Nguyen N Walker P Fetto J
Full Access

Over the last two decades, design modifications in cementless total hip arthoplasty have led to longer lasting implants and an increased success rate. However, there remains limitations to the cementless femoral stem implant. Traditional cementless femoral components require large amounts of bone to be broached prior to stem insertion (. 1. ). This leads to a decrease in host bone stock, which can become problematic in a young patient who may eventually require a revision operation during his or her lifetime. Osteopenia, only second to distal stress shielding can lead to aseptic loosening of the implant and stem subsidence, which also accelerates the need for a revision operation (. 2. –. 4. ). Recent literature suggests that thigh pain due to distal canal fixation, micro-motion, uneven stress patterns or cortex impingement by the femoral stem is directly correlated to increased stem sizes and often very disabling to a patient (. 5. –. 8. ). In this study, we sought to determine whether reducing stem length in the femoral implant would produce more physiologic loading characteristics in the proximal femur and thus eliminate any remaining stress shielding that is present in the current design. We analyzed the surface strains in 13 femurs implanted with. no implants,. stemless,. ultra short and. short stem proximal fill implants in a test rig designed to assimilate muscle forces across the hip joints, including the ilio-tibial band and the hip abductors. Analysis of the resulting surface strains was performed using the photoelastic method. For each femur, intact and with the different stem length components in place, the fringe patterns were compared at the same applied loads. The highest fringe orders observed for all tests were located on the lateral proximal femur and medial proximal femur. The fringes decreased as they approached the neutral axis of bending (posterior and anterior). Distal fringe patterns were more prominent as the stem length increased. The results demonstrate that the stemless design most closely replicated normal strain patterns seen in a native femur during simulated gait. The presence of a stemless, ultra short and short stem reduced proximal strain and increased distal strain linearly, thereby increasing the potential for stress shielding. The stemless design most closely replicated normal strain patterns observed in a native femur and for this reason has the potential to address the shortcomings of the traditional cementless femoral implant


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 760 - 768
1 Jun 2011
ten Broeke RHM Alves A Baumann A Arts JJC Geesink RGT

Four uncemented Symax hip stems were extracted at three weeks and nine, 13 and 32 months, respectively, for reasons other than loosening. The reasons for implant removal were infection in two cases, recurrent dislocation in one and acetabular fracture in one. They were analysed to assess the effect and behaviour of an electrochemically deposited, completely resorbable biomimetic BONIT-hydroxyapatite (HA) coating (proximal part) and a DOTIZE surface treatment (distal part) using qualitative histology, quantitative histomorphometry and scanning electron microscopy (SEM). Early and direct bone-implant bonding with signs of active remodelling of bone and the HA coating were demonstrated by histology and SEM. No loose BONIT-HA particles or delamination of the coating were observed, and there was no inflammation or fibrous interposition at the interface.

Histomorphometry showed bone-implant contact varying between 26.5% at three weeks and 83.5% at 13 months at the HA-coated implant surface. The bone density in the area of investigation was between 24.6% at three weeks and 41.1% at 32 months. The DOTIZE surface treatment of the distal part of the stem completely prevented tissue and bone apposition in all cases, thereby optimising proximal stress transfer.

The overall features of this implant, in terms of geometry and surface texture, suggest a mechanically stable design with a highly active biomimetic coating, resulting in rapid and extensive osseo-integration, exclusively in the metaphyseal part of the stem. Early remodelling of the HA coating does not seem to have a detrimental effect on short-term bone-implant coupling. There were no adverse effects identified from either the BONIT-HA coating or the DOTIZE surface treatment.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 124 - 124
1 Mar 2010
Zelle J Barink M Verdonschot N
Full Access

Introduction: Recently, high-flexion knee implants have been developed to provide for a large range of motion (ROM > 120°) after total knee arthroplasty (TKA). High-flexion knee implants are more likely subjected to large knee loads than conventional implants since knee joint forces increase with larger flexion angles. Highly conforming knee replacements are designed to minimise polyethylene peak stresses during (deep) knee flexion. The Birmingham Knee Replacement (BKR, Jointmedica, UK) is a newly designed knee replacement which combines a high conformity during the complete ROM with the principles of rotating platform and high-flexion TKA. The main objective of this study was to analyze the mechanical performance of the BKR during its full ROM (0°–155°) and investigate whether its high conformity could be maintained during high-flexion. In addition, the BKR polyethylene loading computed in this study was compared with other mobile bearings. Materials & methods: TKA performance was analyzed using a three-dimensional dynamic finite element (FE) model of the knee joint. The FE knee model consisted of a distal femur, a proximal tibia and fibula, a quadriceps and patella tendon, a non-resurfaced patella and TKA components. Tibio-femoral and patello-femoral contact were defined in the knee model. Three different posterior stabilised rotating platform TKAs were subsequently incorporated: the high-flexion BKR, the high-flexion PFC Sigma RP-F and the standard PFC Sigma RP (Depuy, J& J, USA). The polyethylene insert was modelled as a non-linear elastic-plastic material in each TKA system. Polyethylene loading parameters as well as the tibio-femoral contact point locations were computed during an entire flexion movement (0°–155°). Results: In the normal flexion range (flexion ≤ 120°) the three knee implants behaved very similar except for the polyethylene loading at the post. At 120° of flexion, the contact stress at the dish was ±45 MPa for all implants whereas the maximal post-cam contact stress came down to 26.7 MPa for the BKR which was half the amount of contact stress experienced by both PFC Sigma implants. During high-flexion (flexion > 120°), the contact stress difference at the post between the BKR and the PFC Sigma RP-F became smaller and came down to 37.9 MPa and 60.7 MPa, respectively. The total amount of plastic deformation at maximal flexion (155°) was smaller for the BKR (577 mm3) in comparison with the Sigma RP-F (2256 mm3). Femoral rollback was negligible for the BKR in the high-flexion range in comparison with the Sigma RP-F (1.9 mm). Discussion: A comparison between different geometrical models using finite element techniques is jeopardised by differences in element distribution within the various models. These differences may affect calculated parameters such as peak stress values. However, in this study the models were very similar which would indicate that the differences in stress patterns found are due to design differences rather than model artefacts. The current study therefore indicates that the BKR benefits from its high conformity during the full ROM. Hence, the BKR demonstrated relatively low polyethylene stresses. The quadriceps efficiency during deep knee flexion may be lower in case of the BKR since the femoral rollback was negligible at these flexion angles. Whether this phenomenon is of any clinical relevance is unknown


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 474 - 474
1 Sep 2009
Dong N Li N Schmidt W Kester M Wang A Nogler M Krismer M
Full Access

High tensile stress has been considered as a contributing factor to the rim fracture of polyethylene acetabular cup liner. We performed the 3 D Finite Element Analysis (FEA) to compare the stress patterns at the polyethylene liner rim as a function of polyethylene thicknesses and whether or not rim was supported by the titanium acetabular shell extension. Two 3.1 mm thick generic 52 mm titanium alloy acetabular shells with and without 2 mm high rim support extension were modelled. Six corresponding Ultra High Molecular Weight Polyethylene (UHMWPE) liners with inner bearing diameters ranging from 22 mm to 44 mm and same outer diameters, were fixed in the shells. A 2 450 N load was applied through the corresponding CoCr femoral heads to the rims of liners while the acetabular shells were fixed on the outer spherical surface. The FEA was performed in half body of the assembly. The maximum principal stresses at the rim regions of UHMWPE liners were recorded. The results showed that in all rim supported conditions, the maximum principal stress were in compressive patterns, a preferred pattern to reduce the potential polyethylene liner fracture. In rim unsupported conditions, the stresses was in tensile on the internal bearing surface when polyethylene liner thickness was bellow 5 mm, or was bellow 9 mm if the average maximum principal stress cross the rim was considered. We conclude that the metal rim support changes the stress pattern in the rim region of UHMWPE liner to compressive for all liner thicknesses. The stress pattern turns to tensile, or there will be a higher potential for rim fracture, if UHMWPE liner is unsupported and the polyethylene rim thickness is less than 9 mm. Although components used this study did not include the locking details which add higher stress concentrations, the trend of stress patterns should follow the results found in this study