Advertisement for orthosearch.org.uk
Results 1 - 20 of 152
Results per page:
Bone & Joint Research
Vol. 13, Issue 10 | Pages 611 - 621
24 Oct 2024
Wan Q Han Q Liu Y Chen H Zhang A Zhao X Wang J

Aims

This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture.

Methods

Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 27 - 27
19 Aug 2024
Solomon M Plaskos C Pierrepont J
Full Access

The purpose of this study was to investigate the influence of surgical approach on femoral stem version in THA. This was a retrospective database review of 830 THAs in 830 patients that had both preoperative and postoperative CT scans. All patients underwent staged bilateral THAs and received CT-based 3D planning on both sides. Stem version was measured in the second CT-scan and compared to the native neck axis measured in the first CT-scan, using the posterior condyles as the reference for both. Cases were performed by 104 surgeons using either a direct anterior (DAA, n=303) or posterior (PA, n=527) approach and one of four stem designs: quadrangular taper, calcar-guided short stem, flat taper and fit-and-fill. Sub-analyses investigated changes in version for low (≤5°), neutral (5–25°) and high (≥25°) native version subgroups and for the different implant types. Native version was not different between approaches (DAA = 12.6°, PA = 13.6°, p = 0.16). Overall, DAA stems were more anteverted relative to the native neck axis vs PA stems (5.9° vs 1.4°, p<0.001). This trend persisted in hips with high native version (3.2° vs -5.3°, p<0.01) and neutral native version (5.3° vs 1.3°, p<0.001), but did not reach significance in the low native version subgroup (8.9° vs 5.9°, p=0.13). Quadrangular taper, calcar-guided, and flat taper stem types had significantly more anteversion than native for DAA, while no differences were found for PA. Stems implanted with a direct anterior approach had more anteversion than those implanted with a posterior approach. The smaller surgical field, soft tissue tension and lack of a “tibial” vertical reference frame may contribute to this finding


Bone & Joint Open
Vol. 5, Issue 8 | Pages 681 - 687
19 Aug 2024
van de Graaf VA Shen TS Wood JA Chen DB MacDessi SJ

Aims

Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies.

Methods

In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference.


Bone & Joint Research
Vol. 13, Issue 6 | Pages 306 - 314
19 Jun 2024
Wu B Su J Zhang Z Zeng J Fang X Li W Zhang W Huang Z

Aims

To explore the clinical efficacy of using two different types of articulating spacers in two-stage revision for chronic knee periprosthetic joint infection (kPJI).

Methods

A retrospective cohort study of 50 chronic kPJI patients treated with two types of articulating spacers between January 2014 and March 2022 was conducted. The clinical outcomes and functional status of the different articulating spacers were compared. Overall, 17 patients were treated with prosthetic spacers (prosthetic group (PG)), and 33 patients were treated with cement spacers (cement group (CG)). The CG had a longer mean follow-up period (46.67 months (SD 26.61)) than the PG (24.82 months (SD 16.46); p = 0.001).


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 79 - 86
1 Feb 2024
Sato R Hamada H Uemura K Takashima K Ando W Takao M Saito M Sugano N

Aims

This study aimed to investigate the incidence of ≥ 5 mm asymmetry in lower and whole leg lengths (LLs) in patients with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH-OA) and primary hip osteoarthritis (PHOA), and the relationship between lower and whole LL asymmetries and femoral length asymmetry.

Methods

In total, 116 patients who underwent unilateral total hip arthroplasty were included in this study. Of these, 93 had DDH-OA and 23 had PHOA. Patients with DDH-OA were categorized into three groups: Crowe grade I, II/III, and IV. Anatomical femoral length, femoral length greater trochanter (GT), femoral length lesser trochanter (LT), tibial length, foot height, lower LL, and whole LL were evaluated using preoperative CT data of the whole leg in the supine position. Asymmetry was evaluated in the Crowe I, II/III, IV, and PHOA groups.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 961 - 970
1 Sep 2023
Clement ND Galloway S Baron YJ Smith K Weir DJ Deehan DJ

Aims

The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA.

Methods

A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims

The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution.

Methods

We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 100 - 100
10 Feb 2023
Mactier L Baker M Twiggs J Miles B Negus J
Full Access

A primary goal of revision Total Knee Arthroplasty (rTKA) is restoration of the Joint Line (JL) and Posterior Condylar Offsets (PCO). The presence of a native contralateral joint allows JL and PCO to be inferred in a way that could account for patient-specific anatomical variations more accurately than current techniques. This study assesses bilateral distal femoral symmetry in the context of defining targets for restoration of JL and PCO in rTKA. 566 pre-operative CTs for bilateral TKAs were segmented and landmarked by two engineers. Landmarks were taken on both femurs at the medial and lateral epicondyles, distal and posterior condyles and hip and femoral centres. These landmarks were used to calculate the distal and posterior offsets on the medial and lateral sides (MDO, MPO, LDO, LPO respectively), the lateral distal femoral angle (LDFA), TEA to PCA angle (TEAtoPCA) and anatomic to mechanical axis angle (AAtoMA). Mean bilateral differences in these measures were calculated and cases were categorised according to the amount of asymmetry. The database analysed included 54.9% (311) females with a mean population age of 68.8 (±7.8) years. The mean bilateral difference for each measure was: LDFA 1.4° (±1.0), TEAtoPCA 1.3° (±0.9), AAtoMA 0.5° (±0.5), MDO 1.4mm (±1.1), MPO 1.0mm (±0.8). The categorisation of asymmetry for each measure was: LDFA had 39.9% of cases with <1° bilateral difference and 92.4% with <3° bilateral difference, TEAtoPCA had 45.8% <1° and 96.6% <3°, AAtoMA had 85.7% <1° and 99.8% <3°, MDO had 46.2% <1mm and 90.3% <3mm, MPO had 57.0% <1mm and 97.9% <3mm. This study presents evidence supporting bilateral distal femoral symmetry. Using the contralateral anatomy to obtain estimates for JL and PCO in rTKA may result in improvements in intraoperative accuracy compared to current techniques and a more patient specific solution to operative planning


Bone & Joint Research
Vol. 11, Issue 2 | Pages 82 - 90
7 Feb 2022
Eckert JA Bitsch RG Sonntag R Reiner T Schwarze M Jaeger S

Aims. The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. Methods. Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. Results. At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. Conclusion. Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82–90


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 9 - 9
1 Jul 2020
Vendittoli P Blakeney W Kiss M Riviere C Puliero B Beaulieu Y
Full Access

Mechanical alignment (MA) techniques for total knee arthroplasty (TKA) may introduce significant anatomic modifications, as it is known that few patients have neutral femoral, tibial or overall lower limb mechanical axes. A total of 1000 knee CT-Scans were analyzed from a database of patients undergoing TKA. MA tibial and femoral bone resections were simulated. Femoral rotation was aligned with either the trans-epicondylar axis (TEA) or with 3° of external rotation to the posterior condyles (PC). Medial-lateral (DML) and flexion-extension (DFE) gap differences were calculated. Extension space ML imbalances (3mm) occurred in 25% of varus and 54% of valgus knees and significant imbalances (5mm) were present in up to 8% of varus and 19% of valgus knees. For the flexion space DML, higher imbalance rates were created by the TEA technique (p < 0 .001). In valgus knees, TEA resulted in a DML in flexion of 5 mm in 42%, compared to 7% for PC. In varus knees both techniques performed better. When all the differences between DML and DFE are considered together, using TEA there were 18% of valgus knees and 49% of varus knees with < 3 mm imbalances throughout, and using PC 32% of valgus knees and 64% of varus knees. Significant anatomic modifications with related ML or FE gap imbalances are created using MA for TKA. Using MA techniques, PC creates less imbalances than TEA. Some of these imbalances may not be correctable by the surgeon and may explain post-operative TKA instability. Current imaging technology could predict preoperatively these intrinsic imitations of MA. Other alignment techniques that better reproduce knee anatomies should be explored


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 43 - 43
1 Jul 2020
Rollick N Bear J Diamond O Helfet D Wellman D
Full Access

Dual plating of the medial and lateral distal femur has been proposed to reduce angular malunion and hardware failure secondary to delayed union or nonunion. This strategy improves the strength and alignment of the construct, but it may compromise the vascularity of the distal femur paradoxically impairing healing. This study investigates the effect of dual plating versus single plating on the perfusion of the distal femur. Ten matched pairs of fresh-frozen cadaveric lower extremities were assigned to either isolated lateral plating or dual plating of a single limb. The contralateral lower extremity was used as a matched control. A distal femoral locking plate was applied to the lateral side of ten legs using a standard sub-vastus approach. Five femurs had an additional 3.5mm reconstruction plate applied to the medial aspect of the distal femur using a medial sub-vastus approach. The superficial femoral artery and the profunda femoris were cannulated at the level of the femoral head. Gadolinium MRI contrast solution (3:1 gadolinium to saline ration) was injected through the arterial cannula. High resolution fat-suppressed 3D gradient echo sequences were completed both with and without gadolinium contrast. Intra-osseous contributions were quantified within a standardized region of interest (ROI) using customized IDL 6.4 software (Exelis, Boulder, CO). Perfusion of the distal femur was assessed in six different zones. The signal intensity on MRI was then quantified in the distal femur and comparison was made between the experimental plated limb and the contralateral, control limb. Following completion of the MRI protocol, the specimens were injected with latex medium and the extra-osseous vasculature was dissected. Quantitative MRI revealed that application of the lateral distal femoral locking plate reduced the perfusion of the distal femur by 21.7%. Within the dual plating group there was a reduction in perfusion by 24%. There was no significant difference in the perfusion between the isolated lateral plate and the dual plating groups. There were no regional differences in perfusion between the epiphyseal, metaphyseal or meta-diaphyseal regions. Specimen dissection in both plating groups revealed complete destruction of any periosteal vessels that ran underneath either the medial or lateral plates. Multiple small vessels enter the posterior condyles off both superior medial and lateral geniculate arteries and were preserved in all specimens. Furthermore, there was retrograde flow to the distal most aspect of the condyles medially and laterally via the inferior geniculate arteries. The medial vascular pedicle was proximal to the medial plate in all the dual plated specimens and was not disrupted by the medial sub-vastus approach in any specimens. Fixation of the distal femur via a lateral sub-vastus approach and application of a lateral locking plate results in a 21% reduction in perfusion to the distal femur. The addition of a medial 3.5mm reconstruction plate does not significantly compromise the vascularity of the distal femur. The majority of the vascular insult secondary to open reduction, internal fixation of the distal femur occurs with application of the lateral locking plate


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 54 - 54
1 Jul 2020
Vendittoli P Blakeney W Kiss M Puliero B Beaulieu Y
Full Access

Mechanical alignment (MA) techniques for total knee arthroplasty (TKA) introduces significant anatomic modifications and secondary ligament imbalances. A restricted kinematic alignment (rKA) protocol was proposed to minimise these issues and improve TKA clinical results. A total of 1000 knee CT-Scans were analyzed from a database of patients undergoing TKA. rKA tibial and femoral bone resections were simulated. rKA is defined by the following criteria: Independent tibial and femoral cuts within ± 5° of the bone neutral mechanical axis and, a resulting HKA within ± 3° of neutral. Medial-lateral (ΔML) and flexion-extension (ΔFE) gap differences were calculated and compared with MA results. With the MA technique, femoral rotation was aligned with either the trans-epicondylar axis (TEA) or with 3° of external rotation to the posterior condyles (PC). Extension space ML imbalances (>/=3mm) occurred in 33% of TKA with MA technique versus 8% of the knees with rKA (p /=5mm) were present in up to 11% of MA knees versus 1% rKA (p < 0 .001). Using the MA technique, for the flexion space ΔML, higher imbalance rates were created by the TEA technique (p < 0 .001). rKA again performed better than both MA techniques using TEA of 3 degrees PC techniques (p < 0 .001). When all the differences between ΔML and ΔFE are considered together: using TEA there were 40.8% of the knees with < 3 mm imbalances throughout, using PC this was 55.3% and using rKA it was 91.5% of the knees (p < 0 .001). Significantly less anatomic modifications with related ML or FE gap imbalances are created using rKA versus MA for TKA. Using rKA may help the surgeon to balance a TKA, whilst keeping the alignment within a safe range


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 868 - 873
1 Jul 2020
Yang G Dai Y Dong C Kang H Niu J Lin W Wang F

Aims. The purpose of this study was to explore the correlation between femoral torsion and morphology of the distal femoral condyle in patients with trochlear dysplasia and lateral patellar instability. Methods. A total of 90 patients (64 female, 26 male; mean age 22.1 years (SD 7.2)) with lateral patellar dislocation and trochlear dysplasia who were awaiting surgical treatment between January 2015 and June 2019 were retrospectively analyzed. All patients underwent CT scans of the lower limb to assess the femoral torsion and morphology of the distal femur. The femoral torsion at various levels was assessed using the a) femoral anteversion angle (FAA), b) proximal and distal anteversion angle, c) angle of the proximal femoral axis-anatomical epicondylar axis (PFA-AEA), and d) angle of the AEA–posterior condylar line (AEA-PCL). Representative measurements of distal condylar length were taken and parameters using the ratios of the bianterior condyle, biposterior condyle, bicondyle, anterolateral condyle, and anteromedial condyle were calculated and correlated with reference to the AEA, using the Pearson Correlation coefficient. Results. The femoral torsion had a strong correlation with distal condylar morphology. The FAA was significantly correlated with the ratio of the bianterior condyle (r = 0.355; p = 0.009), the AEA-PCL angle (r = 0.340; p = 0.001) and the ratio of the anterolateral condyle and lateral condyle (ALC-LC) (r = 0.309; p = 0.014). The PFA-AEA angle was also significantly correlated with the ratio of the bianterior condyle (r = 0.319; p = 0.008), the AEA-PCL angle (r = 0.231; p = 0.031), and the ratio of ALC-LC (r = 0.261; p = 0.034). In addition, the bianterior condyle ratio showed a significant correlation with the biposterior condyle ratio (r = -0.324; p = 0.027) and the AEA-PCL angle (r = 0.342; p = 0.021). Conclusion. Increased femoral torsion correlated with a prominent anterolateral condyle and a shorter posterolateral condyle compared with the medial condyle. The deformities of the anterior and posterior condyles are combined deformities rather than being isolated and individual deformities in patients with trochlear dysplasia and patella instability. Cite this article: Bone Joint J 2020;102-B(7):868–873


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims

To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps.

Methods

In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 137 - 137
1 Feb 2020
Dessinger G Argenson J Bizzozero P LaCour M Komistek R
Full Access

Introduction. Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both gender and ethnicity. Therefore, the objective of this study was to assess in vivo kinematics for subjects having this TKA type to determine if subjects having this PS TKA experienced more optimal knee kinematics. Methods. Twenty-five subjects in this study were asked to perform a deep knee bend to maximum knee flexion and a step-up maneuver while under fluoroscopic surveillance. All subjects were patients of one experienced surgeon and received the same PS TKA. Using a 3D-2D registration technique, the CAD models, supplied by the sponsoring company, were superimposed over x-ray images at specified increments throughout the fluoroscopic footage. The kinematics were then analyzed to evaluate lateral anterior/posterior (LAP) and medial anterior/posterior (MAP) condyle translation as well as axial rotation of the femur with respect to the tibia. Results. During the DKB activity, the average flexion for the PS TKA subjects was 1108°. On average subjects experienced a lateral condyle motion in the posterior direction of 7.3mm, with the maximum amount of posterior rollback being 12.8 mm. These same subjects experienced an average medial condyle motion in the posterior direction of 4.8 mm with the maximum amount of posterior motion being 7.8 mm. Therefore, with the lateral condyle rolling more posterior than the medial condyle, these subjects experienced an average amount of 7.1° of axial rotation, with a maximum of 12.0°. Only one subject in this study experienced a reverse axial rotation from full extension to maximum knee flexion. During the step-up maneuver, subjects consistently experienced a roll forward motion of both their condyles. Discussion. Subjects in this study experienced a high incidence and magnitude of lateral condyle posterior femoral rollback, leading a normal-like axial rotation pattern, although less in magnitude compared to the normal knee. There was variability occurring with the medial condyle as some experience experienced an anterior slide while others rolled in the posterior direction. As seen in previous studies, during mid flexion both condyles experienced a more variable motion pattern. Twenty-five subjects having a posterior cruciate retaining TKA are being added to this study to determine if retention of the PCL in a similarly designed TKA leads to more normal-like kinematic patterns


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 10 - 10
1 Feb 2020
Vendittoli P Blakeney W Puliero B Beaulieu Y Kiss M
Full Access

INTRODUCTION. Mechanical alignment in TKA introduces significant anatomic modifications for many individuals, which may result in unequal medial-lateral or flexion-extension bone resections. The objective of this study was to calculate bone resection thicknesses and resulting gap sizes, simulating a measured resection mechanical alignment technique for TKA. METHODS. Measured resection mechanical alignment bone resections were simulated on 1000 consecutive lower limb CT-Scans from patients undergoing TKA. Bone resections were simulated to reproduce the following measured resection mechanical alignment surgical technique. The distal femoral and proximal tibial cuts were perpendicular to the mechanical axis, setting the resection depth at 8mm from the most distal femoral condyle and from the most proximal tibial plateau (Figure 1). If the resection of the contralateral side was <0mm, the resection level was increased such that the minimum resection was 0mm. An 8mm resection thickness was based on an implant size of 10mm (bone +2mm of cartilage). Femoral rotation was aligned with either the trans-epicondylar axis or with 3 degrees of external rotation to the posterior condyles. After simulation of the bone cuts, media-lateral gap difference and flexion-extension gaps difference were calculated. The gap sizes were calculated as the sum of the femoral and tibial bone resections, with a target bone resection of 16mm (+ cartilage corresponding to the implant thickness). RESULTS. For both the varus and valgus knees, the created gaps in the medial and lateral compartments were reduced in the vast majority of cases (<16mm). The insufficient lateral condyle resection distalises the lateral joint surface by a mean of 2.1mm for the varus and 4.4mm for the valgus knees. The insufficient medial tibial plateau resection proximalises the medial joint surface by 3.3mm for the varus and 1.2mm for the valgus knees. Medio-lateral gap imbalances in the extension space of more than 2mm) occurred in 25% of varus and 54% of valgus knees and significant imbalances of more than 5mm were present in up to 8% of varus and 19% of valgus knees. Higher medio-lateral gap imbalances in the flexion space were created with trans epicondylar axis versus 3 degrees to the posterior condyles (p<0.001). Using trans epicondylar axis, only 49% of varus and 18% of valgus knees had less than 3mm of imbalance in both media-lateral and flexion-extension gaps together. DISCUSSION AND CONCLUSION. A systematic use of the tested measured resection mechanical alignment technique for TKA leads to many cases with medio-lateral or flexion-extension gap asymmetries. Some medio-lateral imbalances may not be correctable surgically and may results in TKA instability. Other versions of the mechanical alignment technique or other alignment methods that better reproduce knee anatomies should be explored. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 38 - 38
1 Feb 2020
Kawamoto T Iida S Sakashita K
Full Access

Background. Total knee arthroplasty (TKA) was primarily considered a successful procedure, several new knee implants were introduced in recent years that seek to obtain improved stability and higher flexion. One of the implant, Vanguard XP. TM. BiCruciate retaining (BCR), Zinmmer-Biomet, USA recreates a specific kinematic model through the principle of normal joint. Patients and Method. An unselected consecutive series of sixty-two patients undergoing primary TKA using the cemented total knee system between August 2016 and April 2018 were studied. Twenty-seven knees was operated using Vanguard XP, subsequently thirty-five knees were received a TKA using cruciate retaining cemented total knee system FINE. TM. CR, Nakashimamedical, Japan. Postoperatively standing AP hip-to-ankle radiographs were obtained, from which the lower extremity mechanical axis, component angle were measured. The alignment goals were a neutral mechanical axis defined as a hip-to-ankle angle of 0°with the femoral and tibial components aligned perpendicular to the mechanical axis. The total operating time were quantified utilising an operating room database. The total operating time between TKAs performed with Vanguard XP BCR and those performed with FINE CR was compared in each group. All patients postoperatively was evaluated of clinical results the Japan Orthopedics Association(JOA) Knee scores. We evaluated femoral component posterior offset (PFCO) in both of two group. The maximal protrusion of the posterior condyle, posteriorly to the extension line parallel to the tibial shaft from the edge of the posterior tibial component was measured on true lateral radiographs. Results. The JOA Knee score of Vanguard XP BCR group was 86.5±4.7 points, and the score of FINE group was 82.7±5.9 points, there was no statistical significance between the two groups on the clinical score. The operative time in Vanguard XP BCR was 137.2±14.6 minutes and significantly more compared to the time of FINE group 111.3±11.9 minutes. The mechanical axis angle in Vanguard XP BCR group was −1.3°±2.7, while FINE CR group was −0.7°±3.2, there was no statistical significance. The number of outliers for mechanical axis angle was Vanguard XP BCR group 25%, the FINE group 24%, between the two groups there was no statistical significance. The mean value of the femoral component posterior offset ratio of Vanguard XP BCR was 14.4%±0.1. The mean value of the posterior offset ratio of FINE group was 16.7%±0.1, between the two groups there was statistical significance. Discussion. Bellemans et al. first defined the concept of posterior condylar offset. They demonstrated that the maximum active flexion possible was limited by direct impingement of the posterior aspect of the tibial component against the posterior aspect of the femur. However, the offset also reduces the extension gap. An enlarged posterior femoral component may reduce the extension gap due to posterior tissue tightness. In this study, the femoral component posterior offset ratio of Vanguard XP BCR was good results compared to the CR type FINE. Clinical results and the mechanical axis angle was good both of the group, but the operative time in Vanguard XP BCR was significantly more compared to the time of FINE group. Conclusion. Good early clinical results were obtained with Vanguard XP BCR knee implant, long-term follow-up studies are needed to confirm our findings


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 7 - 7
1 Feb 2020
Wakelin E Shalhoub S Lawrence J DeClaire J Koenig J Ponder C Randall A Keggi J Plaskos C
Full Access

Introduction. Achieving a well-balanced midflexion and flexion soft tissue envelope is a major goal in Total Knee Arthroplasty (TKA). The definition of soft tissue balance that results in optimal outcomes, however, is not well understood. Studies have investigated the native soft tissue envelope in cadaveric specimen and have shown loosening of the knee in flexion, particularly on the lateral side. These methods however do not reflect the post TKA environment, are invasive, and not appropriate for intra-operative use. This study utilizes a digital gap measuring tool to investigate the impact of soft tissue balance in midflexion and flexion on post-operative pain. Methods. A prospective multicenter multi-surgeon study was performed in which patients underwent TKA with a dynamic ligament-balancing tool in combination with a robotic-assisted navigation platform. All surgeries were performed with APEX implants (Corin Ltd., USA) using a variety of tibia and femur first techniques. Gap measurements were acquired under load (average 80 N) throughout the range of motion during trialing with the balancing tool inserted in place of the tibial trial. Patients completed KOOS pain questionnaires at 3months±2weeks post-op. Linear correlations were investigated between KOOS pain and coronal gap measurements in midflexion (30°–60°) and flexion (>70°). T-tests were used to compare outcomes between categorical data. Results. 92 patients underwent TKA and completed questionnaires, with an average age of 68±9 years, 51% left and 57% female. No significant correlations were found between the medial and lateral gap size in midflexion or flexion and post-operative pain. Significant correlations were found between the absolute difference in the medial and lateral gaps in midflexion (r=−0.3, p=0.005) and flexion (r=−0.27, p=0.01) indicating knees with a more balance soft tissue profile reported improved pain outcomes at 3-months. Knees with less than 1mm difference in ML gap reported improved pain scores compared to those with greater gap differences in flexion (Δ=6.6, p=0.03). A significant correlation was found between the difference in average gaps in midflexion and flexion, and post-op pain (r=0.22, p=0.04) in which knees that were looser in flexion than midflexion reported improved pain outcomes. When dichotomizing these results in to looser or tighter in flexion compared to midflexion, knees that were looser reported significantly improved pain outcomes (Δ=8.2, p=0.02). Discussion and Conclusion. Improved outcomes correlated with a symmetrically balanced coronal midflexion gap and looser flexion space is consistent with the soft tissue balance of the native knee. The lack of a correlation between lateral loosening in flexion and improved outcomes may be a result of greater congruency between the femoral component and tibial insert than the native knee, preventing medial pivot lateral posterior condyle rollback motion. These results indicate that targeting the native soft tissue profile may not result in optimal outcomes when performing a TKA with a neutral tibial resection and an externally rotated femoral component. Further investigation is required to determine if these results hold with a larger data set and the effect on functional outcomes at both 3-months and longer follow-up periods. For any figures or tables, please contact authors directly