The June 2024 Knee Roundup360 looks at: The estimated lifetime risk of revision after primary knee arthroplasty influenced by age, sex, and indication; Should high-risk patients seek out care from high-volume surgeons?; Stability and fracture rates in medial unicondylar knee arthroplasties; Rethinking antibiotic prophylaxis for dental procedures post-arthroplasty; Evaluating DAIR: a viable alternative for acute periprosthetic joint infection; The characteristics and predictors of mortality in periprosthetic fractures around the knee; Patient health-related quality of life deteriorates significantly while waiting six to 12 months for total hip or knee arthroplasty; The importance of looking for diversity in knee implants.
Aims. The localization of necrotic areas has been reported to impact the prognosis and treatment strategy for osteonecrosis of the femoral head (ONFH). Anteroposterior localization of the necrotic area after a femoral neck fracture (FNF) has not been properly investigated. We hypothesize that the change of the weight loading direction on the femoral head due to residual posterior tilt caused by malunited FNF may affect the location of ONFH. We investigate the relationship between the
This study aimed to describe the morphology of the coracoid process and determine the frequency of commonly observed patterns. The second purpose was to determine the location of inferior tunnel exit with superior based tunnel drilling and the superior tunnel exit with inferior based tunnel drilling. A sample of 100 dry scapulae for the morphology aspect and 52 cadaveric embalmed shoulders for tunnel drilling were used. The coracoid process was described qualitatively and categorized into 6 different shapes. A transcoracoid tunnel was drilled at the centre of the base. Twenty-six shoulders were used for the superior-inferior tunnel drilling approach and 26 for the inferior-superior tunnel drilling approach. The distances to the margins of the coracoid process, from both the entry and exit points of the tunnel, were measured. Eight coracoid processes were of convex shape, 31 of hooked shape, 18 of irregular shape, 18 of narrow shape, 25 of straight shape, and 13 of wide shape. The mean difference for the distances between superior entry and inferior exit from the apex was Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation 3.65+3.51mm (p=0.002); 1.57+2.27mm for the lateral border (p=0.40) and 5.53+3.45mm for the medial border (p=0.001). The mean difference for the distances between inferior entry and superior exit from the apex was 16.95+3.11mm (p=0.0001); 6.51+3.2mm for the lateral border (p=0.40) and 1.03+2.32 mm for the medial border (p=0.045). The most common coracoid process shape observed was a hooked pattern. Both superior to inferior and inferior to superior tunnel drilling directed the tunnel from a more anterior and medial entry to a posterior-lateral exit. Superior to inferior drilling resulted in a more
Abstract. Introduction. Changes in posterior tibial slope (PTS) and patellar height (PH) following proximal tibial osteotomies have been a recent focus for knee surgeons. Increased PTS and decreased PH following medial opening wedge high tibial osteotomy (MOWHTO) have been repeatedly reported in the literature. However, this has been disputed in more recent biomechanical studies. Methodology. A total of 62 cases who underwent MOWHTO were included. Surgery was performed using a dedicated step-by-step protocol focusing on the risks of unintentional slope changes. Clinically, all patients were evaluated preoperatively and at 2 years follow-up with the KOOS scores and UCLA physical activity scale. Preoperative and postoperative radiographic lower limb alignment parameters were measured on full-length lower limb radiographs, including (HKA), (MPTA), (mLDFA), proximal
The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients more than 60 years with a minimum follow up of one year. We retrospectively reviewed 51 consecutive patients aged more than 60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative
Abstract. Background. The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients >60 years with a minimum follow up of one year. Methods. We retrospectively reviewed 51 consecutive patients >60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative
Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with preoperative radiographs and 47 with post-operative radiographs treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in pelvic tilt angle was measured both by the Sacro-Femoral-Pubic (SFP) angle and the Pubic Symphysis to Sacro-iliac (PS-SI) Index. In the supine position, the mean calculated pelvic tilt angle (by SFP) was 1.05° which changed on standing to a pelvic tilt of 8.64°. A significant increase in
Aims. In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. Methods. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival. Results. A total of 114 operations were performed on 112 patients with a mean age of 80.2 years (SD 8.9). The 30-day and one-year mortality were 1% (n = 1) and 13% (n = 15), respectively. Median follow-up was 6.6 years (interquartile range 6.0 to 7.3). Kaplan-Meier estimates showed a survivorship of 95% at one year and 90% at five years (95% confidence interval 84% to 95%) for cannulated screws. Nine patients underwent further hip surgery: four revision to total hip arthroplasty, one revision to hemiarthroplasty, three removals of screws, and one haematoma washout. Posterior tilt was assessable in 106 patients; subsequent surgery was required in two of the six patients identified with a
Introduction and Objective. The geometry of the proximal tibia and distal femur is intimately linked with the biomechanics of the knee and it is to be considered in total knee arthroplasty (TKA) component positioning. The aim of the present study was to evaluate the proximal tibial torsion in relation to the flexion-extension axis of the knee in healthy and pathological cohort affected by knee osteoarthritis (OA). Materials and Methods. We retrospectively analyzed computed tomography scans of OA knee of 59 patients prior to TKA and non-arthritic knee of 39 patients as control.
Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with preoperative radiographs and 47 with post-operative radiographs treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in pelvic tilt angle was measured both by the Sacro-Femoral-Pubic (SFP) angle and the Pubic Symphysis to Sacro-iliac (PS-SI) Index. In the supine position, the mean calculated pelvic tilt angle (by SFP) was 1.05° which changed on standing to a pelvic tilt of 8.64°. A significant increase in
Aims. Pelvic incidence (PI) is considered an important anatomical parameter for determining the sagittal balance of the spine. The contribution of an abnormal PI to hip osteoarthritis (OA) remains controversial. In this study, we aimed to investigate the relationship between PI and hip OA, and the difference in PI between hip OA without anatomical abnormalities (primary OA) and hip OA with developmental dysplasia of the hip (DDH-OA). Methods. In this study, 100 patients each of primary OA, DDH-OA, and control subjects with no history of hip disease were included. CT images were used to measure PI, sagittal femoral head coverage, α angle, and acetabular anteversion. PI was also subdivided into three categories: high PI (larger than 64.0°), medium PI (42.0° to 64.0°), and low PI (less than 42.0°). The anterior centre edge
Aim. To investigate the effect of the eight plate position in sagittal plane on tibial slope in temporary epiphysiodesis technique applied to the proximal tibia and whether there is a rebound effect after removing the plate. Method. Forty New Zealand rabbits (6 weeks old) were divided into four groups. In all groups, two 1.3 mm mini plates and cortical screws implantation were placed on both medial and lateral side of the proximal epiphysis of the right tibia. In Group 1 and 3, the plates were placed on anterior of the proximal tibial anatomical axis in the sagittal plane, and placed posteriorly in Group 2 and 4. The left tibia was examined as control in all groups. Group 1 and Group 2 were sacrificed after four week-follow-up. In Group 3 and Group 4, the implants were removed four weeks after index surgery and the rabbits were followed four more weeks to investigate the rebound effect. The tibial slope was measured on lateral X-rays every two weeks. Both medial and lateral plateau slopes were evaluated on photos of the dissected tibia. Results. In Group 1, right MTPA (medial tibial plateau angle) and left MTPA, right LTPA (lateral tibial plateau angle) and left LTPA, and right 4wTPPA (the tibial proximal
Our retrospective analysis reports the outcome of patients operated for slipped capital femoral epiphysis using the modified Dunn procedure. Results, complications, and the need for revision surgery are compared with the recent literature. We retrospectively evaluated 17 patients (18 hips) who underwent the modified Dunn procedure for the treatment of slipped capital femoral epiphysis. Outcome measurement included standardized scores. Clinical assessment included ambulation, leg length discrepancy, and hip mobility. Radiographically, the quality of epiphyseal reduction was evaluated using the Southwick and Alpha-angles. Avascular necrosis, heterotopic ossifications, and osteoarthritis were documented at follow-up.Aims
Methods
Introduction. Instability, loosening, and patellofemoral pain belong to the main causes for revision of total knee arthroplasty (TKA). Currently, the diagnostic pathway requires various diagnostic techniques such as x-rays, CT or SPECT-CT to reveal the original cause for the failed knee prosthesis, but increase radiation exposure and fail to show soft-tissue structures around TKA. There is a growing demand for a diagnostic tool that is able to simultaneously visualize soft tissue structures, bone, and TKA without radiation exposure. MRI is capable of visualising all the structures in the knee although it is still disturbed by susceptibility artefacts caused by the metal implant. Low-field MRI (0.25T) results in less metal artefacts and offers the ability to visualize the knee in weight-bearing condition. Therefore, the aim of this study is to investigate the possibilities of low field MRI to image, the patellofemoral joint and the prosthesis to evaluate the knee joint in patients with and without complaints after TKA. Method. Ten patients, eight satisfied and two unsatisfied with their primary TKA, (NexGen posterior stabilized, BiometZimmer) were included. The patients were scanned in sagittal, coronal, and transversal direction on a low field MRI scanner (G-scan Brio, 0.25T, Esaote SpA, Italy) in weight-bearing and non-weight-bearing conditions with T1, T2 and PD-weighted metal artefact reducing sequences (TE/TR 12–72/1160–7060, slice thickness 4.0mm, FOV 260×260×120m. 3. , matrix size 224×216). Scans were analysed by two observers for:. - Patellofemoral joint: Caton-Descamps index and Tibial Tuberosity-Trochlear Groove (TT-TG) distance. - Prosthesis malalignment: femoral component rotation using the
The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases? A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).Aims
Patients and Methods
Introduction. Implant malalignment is an important predictor of prosthetic failure following total knee arthroplasty (TKA). The purpose of this study was to determine the incidence of outliers for common alignment targets and the impact of surgeon volume and experience on the accuracy of implant alignment with current generation manual instrumentation. Methods. This study was a retrospective, multi-center, radiographic analysis of 1675 consecutive primary uncomplicated TKAs from seven surgeons at three academic and state-funded centers in the US and UK. Surgeons were categorized as “high-volume” (≥50 TKAs/year) and “high-experience” (≥5 years post-fellowship). Femorotibial, tibial varus/valgus, and posterior tibial slope angles were digitally measured using postoperative radiographs. Femorotibial (<2° or >8° valgus), tibial (> ±3° deviation from the neutral axis), and tibial slope (<0° or >7° of flexion for cruciate retaining, <0° or >5° of flexion for
The aim of this study was to investigate the clinical and radiographic
outcomes of microendoscopic laminotomy in patients with lumbar stenosis
and concurrent degenerative spondylolisthesis (DS), and to determine
the effect of this procedure on spinal stability. A total of 304 consecutive patients with single-level lumbar
DS with concomitant stenosis underwent microendoscopic laminotomy
without fusion between January 2004 and December 2010. Patients
were divided into two groups, those with and without advanced DS
based on the degree of spondylolisthesis and dynamic instability. A
total of 242 patients met the inclusion criteria. There were 101
men and 141 women. Their mean age was 68.1 years (46 to 85). Outcome
was assessed using the Japanese Orthopaedic Association and Roland
Morris Disability Questionnaire scores, a visual analogue score
for pain and the Short Form Health-36 score. The radiographic outcome
was assessed by measuring the slip and the disc height. The clinical
and radiographic parameters were evaluated at a mean follow-up of
4.6 years (3 to 7.5).Aims
Patients and Methods
The morphometry of the distal femur was largely studied to improve
bone-implant fit in total knee arthroplasty (TKA), but little is
known about the asymmetry of the posterior condyles. This study
aimed to investigate the dimensions of the posterior condyles and
the influence of externally rotating the femoral component on potential prosthetic
overhang or under-coverage. We analysed the shape of 110 arthritic knees at the time of primary
TKA using pre-operative CT scans. The height and width of each condyle
were measured at the posterior femoral cut in neutral position,
and in 3º and 5º of external rotation, using both central and medial
referencing systems. We compared the morphological characteristics
with those of 14 TKA models.Aims
Patients and Methods
Introduction. A femoral rotational alignment is one of the essential factors, affecting the postoperative knee balance and patellofemoral tracking in total knee arthroplasty (TKA). To obtain an adequate alignment, the femoral component must be implanted parallel to the surgical epicondylar axis (SEA). We have developed “a superimposable Computed Tomography (CT) scan-based template”, in which the SEA is drawn on a distal femoral cross section of the CT image at the assumed bone resection level, to determine the precise SEA. Therefore, the objective of this study was to evaluate the accuracy of the rotational alignment of the femoral component positioned with the superimposed template in TKA. Patients and methods. Twenty-six consecutive TKA patients, including 4 females with bilateral TKAs were enrolled. To prepare a template, all knees received CT scans with a 2.5 mm slice thickness preoperatively. Serial three slices of the CT images, in which the medial epicondyle and/or lateral epicondyle were visible, were selected. Then, these images were merged into a single image onto which the SEA was drawn. Thereafter, another serial two CT images, which were taken at approximately 9 mm proximal from the femoral condyles, were also selected, and the earlier drawn SEA was traced onto each of these pictures. These pictures with the SEA were then printed out onto transparent sheets to be used as potential “templates” (Fig. 1-a). In the TKA, the distal femur was resected with the modified measured resection technique. Then, one template, whichever of the two potential templates, was closer to the actual shape, was selected and its SEA was duplicated onto the distal femoral surface (Fig. 1-b). Following that, the distal femur was resected parallel to this SEA. The rotational alignment of the femoral component was evaluated with CT scan postoperatively. For convention, an external rotation of the femoral component from the SEA was given a positive numerical value, and an internal rotation was given a negative numerical value. Results. The subjects were 4 knees in 4 males and 26 knees in 22 females. A mean age (for 30 knees) at the operation was 76.7 ± 6.1 years (range from 66.4 to 88.3). The