Advertisement for orthosearch.org.uk
Results 1 - 20 of 37
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 89 - 89
7 Nov 2023
Greenwood K Molepo M Mogale N Keough N Hohmann E
Full Access

The posterior compartments of the knee are currently accessed arthroscopically through anterior, posteromedial or posterolateral portals. A direct posterior portal to access the posterior compartments has been overlooked due to a perceived high-risk of injury to the popliteal neurovascular structures. Therefore, this study aimed to investigate the safety and accessibility of a direct posterior portal into the knee. This cross-sectional study comprised a sample of 95 formalin-embalmed cadaveric knees and 9 fresh-frozen knees. Cannulas were inserted into the knees, 16mm from the vertical plane between the medial epicondyle of the femur and medial condyle of the tibia and 8 and 14mm (females and males respectively) from the vertical plane connecting the lateral femoral epicondyle and lateral tibial condyle. Landmarks were identified in full extension and cannula insertion was completed with the formalin-embalmed knees in full extension and the fresh-frozen in 90-degree flexion. Posterior aspects of the knees were dissected from superficial to deep, to assess potential damage caused by cannula insertion. Incidence of neurovascular damage was 9.6% (n=10); 0.96% medial cannula and 8.7% lateral cannula. The medial cannula damaged one small saphenous vein (SSV) in a male specimen. The lateral cannula damaged one SSV, 7 common fibular nerves (CFN) and both CFN and lateral cutaneous sural nerve in one specimen. All incidences of damage occurred in formalin-embalmed knees. The posterior horns of the menisci were accessible in all specimens. A medial-lying direct posterior portal into the knee is safe in 99% of occurrences. The lateral-lying direct posterior portal is of high risk to the CFN


Bone & Joint Open
Vol. 4, Issue 3 | Pages 158 - 167
10 Mar 2023
Landers S Hely R Hely A Harrison B Page RS Maister N Gwini SM Gill SD

Aims

This study investigated the effects of transcatheter arterial embolization (TAE) on pain, function, and quality of life in people with early-stage symptomatic knee osteoarthritis (OA) compared to a sham procedure.

Methods

A total of 59 participants with symptomatic Kellgren-Lawrence grade 2 knee OA were randomly allocated to TAE or a sham procedure. The intervention group underwent TAE of one or more genicular arteries. The control group received a blinded sham procedure. The primary outcome was knee pain at 12 months according to the Knee injury and Osteoarthritis Outcome Score (KOOS) pain scale. Secondary outcomes included self-reported function and quality of life (KOOS, EuroQol five-dimension five-level questionnaire (EQ-5D-5L)), self-reported Global Change, six-minute walk test, 30-second chair stand test, and adverse events. Subgroup analyses compared participants who received complete embolization of all genicular arteries (as distinct from embolization of some arteries) (n = 17) with the control group (n = 29) for KOOS and Global Change scores at 12 months. Continuous variables were analyzed with quantile regression, adjusting for baseline scores. Dichotomized variables were analyzed with chi-squared tests.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 102 - 108
1 Feb 2023
MacDessi SJ Oussedik S Abdel MP Victor J Pagnano MW Haddad FS

Orthopaedic surgeons are currently faced with an overwhelming number of choices surrounding total knee arthroplasty (TKA), not only with the latest technologies and prostheses, but also fundamental decisions on alignment philosophies. From ‘mechanical’ to ‘adjusted mechanical’ to ‘restricted kinematic’ to ‘unrestricted kinematic’ — and how constitutional alignment relates to these — there is potential for ambiguity when thinking about and discussing such concepts. This annotation summarizes the various alignment strategies currently employed in TKA. It provides a clear framework and consistent language that will assist surgeons to compare confidently and contrast the concepts, while also discussing the latest opinions about alignment in TKA. Finally, it provides suggestions for applying consistent nomenclature to future research, especially as we explore the implications of 3D alignment patterns on patient outcomes.

Cite this article: Bone Joint J 2023;105-B(2):102–108.


Aims

Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation.

Methods

We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Tibial cut is a crucial step in ensuring adequate and appropriate proximal tibial resection for mechanical orientation and axis in total knee replacement. We evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects individual mechanical orientation and alignment. We used Condylar Differential in 37 consecutive total knee replacements including valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis. The distances between the horizontal line and the lowest reproducible points of articular surfaces of medial and lateral tibial condyles respectively are measured. The difference between two measurements obviously represents Condylar Differential. Condylar Differential, adjusted to the nearest millimetre, is maintained in executing tibial cuts, successively if necessary. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualises the tibial cut for optimal templating of tibia. We encountered no problems, adopting this technique, in our series. Condylar Differential contributes to optimal individualised tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique in digitised radiographs, this technique can also be applied to plain films, allowing for magnification


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 145 - 145
1 Apr 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Background. Mechanics and kinematics of the knee following total knee replacement are related to the mechanics and kinematics of the normal knee. Restoration of neutral alignment is an important factor affecting the long-term results of total knee replacement. Tibial cut is a vital and crucial step in ensuring adequate and appropriate proximal tibial resection, which is essential for mechanical orientation and axis in total knee replacement. Tibial cut must be individually reliable, reproducible, consistent and an accurate predictor of individual anatomical measurements. Conventional tibial cuts of tibia with fixed measurements cannot account for individual variations. While computer navigated total knee replacement serves as a medium to achieve this objective, the technology is not universally applicable for differing reasons. Therefore we evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects the individual mechanical orientation and alignment. Methods. We used the Condylar Differential in 37 consecutive total knee replacements. We also applied the technique in valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on the digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis of tibia. The distances between the horizontal line and the lowest reproducible points of the articular surfaces of the medial and lateral tibial condyles respectively are measured. The difference between the two measurements obviously represents the Condylar Differential. Condylar Differential, adjusted to the nearest millimeter, is maintained in executing the tibial cuts, if necessary successive cuts. Results. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualizes the tibial cut for optimal templating of tibia in total knee replacement. We encountered no problems, adopting this technique, in our consecutive series of total knee replacements. Conclusions. Condylar Differential contributes to optimal individualized tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique of Condylar Differential in digitized radiographs, this technique can also be applied to plain films, allowing for the magnification


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1319 - 1328
1 Oct 2017
Shelton TJ Nedopil AJ Howell SM Hull ML

Aims

The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces.

Patients and Methods

The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria.


Bone & Joint Research
Vol. 6, Issue 1 | Pages 43 - 51
1 Jan 2017
Nakamura S Tian Y Tanaka Y Kuriyama S Ito H Furu M Matsuda S

Objectives

Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments.

Materials and Methods

Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1020 - 1026
1 Aug 2016
Śmigielski R Zdanowicz U Drwięga M Ciszek B Williams A

Anterior cruciate ligament (ACL) reconstruction is commonly performed and has been for many years. Despite this, the technical details related to ACL anatomy, such as tunnel placement, are still a topic for debate. In this paper, we introduce the flat ribbon concept of the anatomy of the ACL, and its relevance to clinical practice.

Cite this article: Bone Joint J 2016;98-B:1020–6.


Bone & Joint Research
Vol. 5, Issue 7 | Pages 294 - 300
1 Jul 2016
Nishioka H Nakamura E Hirose J Okamoto N Yamabe S Mizuta H

Objectives

The purpose of this study was to clarify the appearance of the reparative tissue on the articular surface and to analyse the properties of the reparative tissue after hemicallotasis osteotomy (HCO) using MRI T1ρ and T2 mapping.

Methods

Coronal T1ρ and T2 mapping and three-dimensional gradient-echo images were obtained from 20 subjects with medial knee osteoarthritis. We set the regions of interest (ROIs) on the full-thickness cartilage of the medial femoral condyle (MFC) and medial tibial plateau (MTP) of the knee and measured the cartilage thickness (mm) and T1ρ and T2 relaxation times (ms). Statistical analysis of time-dependent changes in the cartilage thickness and the T1ρ and T2 relaxation times was performed using one-way analysis of variance, and Scheffe’s test was employed for post hoc multiple comparison.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 74 - 74
1 May 2016
Kanagawa H Kodama T Tsuji O Nakayama M Shiromoto Y Ogawa Y
Full Access

Introduction. We report a case which total knee arthroplasty (TKA) was able to be performed on schedule for the patient with occult fracture of proximal tibia which seemed to have occurred three months prior to the surgery, and has healed in short period of time by the use of Teriparatide. Case report. The patient is 84-year-old female, having right knee pain for past 7 years. Her knee pain increased by passive extension maneuver that was done by a bonesetter 3 months prior to the surgery. On her initial visit, the X-ray finding was severe medial osteoarthritis, and femorotibial angle (FTA) in the upright film was 197°, but there was no other disorder including fracture. Since the bone mineral density (BMD) of affected femoral neck was 62%YAM, and affected lateral femoral condyle as well as lateral tibial condyle seemed very porotic, we started using daily 20μg Teriparatide injection from 3 months prior to the surgery. Proximal tibial fracture was presented in the X-ray taken on the day before surgery, but since adequate bone union has already been formed, surgery was performed on schedule. Tibial implant with long stem was used for just to be certain. Thanks to the Teriparatide, the condition of cancellous bone in cut surface was excellent, and reaming of the tibia through fracture area felt very solid. Discussion. Proximal tibial fracture that occurred just before TKA is very rare. The fracture in this case was probably due to the maneuver done by the bonesetter. Teriparatide is indicated when osteoporosis is severe and the patient is at risk for fracture. We also indicate Teriparatide for the patients whose femoral neck BMD is very low and severe valgus knee or varus knee is present. Unloaded side of femoral or tibial condyle is usually very porotic in such a case. In our case, the fracture was so called fragility fracture which was found incidentally the day before surgery, but TKA could be done on schedule since adequate callus has been formed by the use of Teriparatide which started 3 months prior to the surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 68 - 68
1 May 2016
Muratsu H Takemori T Matsumoto T Annziki K Kudo K Yamaura K Minamino S Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction. To achieve well aligned and balanced knee is essential for the post-operative outcome in total knee arthroplasty (TKA). Gap balancing technique can adjust the bone cut depending on the soft tissue balance in addition to soft tissue releases. Therefore, gap balancing technique would be more advantageous in soft tissue balance comparing to measured resection technique (MRT) in which soft tissue balancing relayed on soft tissue releases alone. Nevertheless, the influence of surgical technique on the post-operative knee stability has not been fully investigated. Objective. We introduced a new surgical technique (medial gap technique: MGT) according to modified gap technique regarding medial knee stability as important. The intra-operative soft tissue balance and post-operative knee stability were compared between MGT and MRT in posterior-stabilized (PS) TKA for varus type osteoarthritic knees. Materials & Methods. Sixty varus type osteoarthritis knees were involved in this study. PS type TKAs (NexGen LPS flexR) were performed using MGT in 30 knees (MGT group) and MRT in 30 knees (MRT group). The extension gap was made in the same manners in both groups. Both femoral and tibial bone cuts were perpendicular to the mechanical axis. Medial soft tissue releases were limited until the spacer block with the thickness corresponding to the resected lateral tibial condyle could be inserted. After extension gap was prepared, OFR-tensorR was used to assess soft tissue balance (center gap, varus angle) at extension and flexion prior to posterior femoral condyle bone resection. Both differences of the center gap and varus angle between at extension and flexion were calculated and used for size selection and external rotation angle of femoral component in MGT. The final joint component gaps were evaluated using OFR-tensorR with both femoral trial in place and patello-femoral joint reduced at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. Quantitative stress radiographies were performed at 1 month, 6 months and 1 year post-operatively to assess joint stability. Joint opening distance (mm) at both medial and lateral joint compartment were measured with knee extension and flexion. Each parameter was compared between MGT and MRT group using unpaired t-test (p<0.05). Results. Pre-operative factors showed no significant differences between 2 groups. The joint component gaps were significantly larger in MRT group from 45 to 135 degrees of flexion (Fig.1). The joint opening at the lateral compartment was significantly larger than medial at both knee extension and flexion in both groups. The joint openings were significantly larger bilaterally in MRT group comparing to MGT group at both extension and flexion (Fig.2, 3). Discussions. Medial instability has been reported as a possible reason for the persistent knee pain after TKA in the varus knees. We proposed a new surgical technique (MGT) not to deteriorate medial stability and allow lateral looseness in TKA. Post-operative knee stability was superior in MGT group comparing to MRT group from one month to one year after surgery. The difference of the intra-operative soft tissue balance might play an important role on the post-operative knee stability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2016
Choi CH Chung KS Lee JK Lee HJ
Full Access

Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty. Materials and Methods. We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter. Results. At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews. Conclusions. The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period. Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3)


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1631 - 1636
1 Dec 2014
Parkkinen M Madanat R Mäkinen TJ Mustonen A Koskinen SK Lindahl J

The role of arthroscopy in the treatment of soft-tissue injuries associated with proximal tibial fractures remains debatable. Our hypothesis was that MRI over-diagnoses clinically relevant associated soft-tissue injuries. This prospective study involved 50 consecutive patients who underwent surgical treatment for a split-depression fracture of the lateral tibial condyle (AO/OTA type B3.1). The mean age of patients was 50 years (23 to 86) and 27 (54%) were female. All patients had MRI and arthroscopy. Arthroscopy identified 12 tears of the lateral meniscus, including eight bucket-handle tears that were sutured and four that were resected, as well as six tears of the medial meniscus, of which five were resected. Lateral meniscal injuries were diagnosed on MRI in four of 12 patients, yielding an overall sensitivity of 33% (95% confidence interval (CI) 11 to 65). Specificity was 76% (95% CI 59 to 88), with nine tears diagnosed among 38 menisci that did not contain a tear. MRI identified medial meniscal injuries in four of six patients, yielding an overall sensitivity of 67% (95% CI 24 to 94). Specificity was 66% (95% CI 50 to 79), with 15 tears diagnosed in 44 menisci that did not contain tears. MRI appears to offer only a marginal benefit as the specificity and sensitivity for diagnosing meniscal injuries are poor in patients with a fracture. There were fewer arthroscopically-confirmed associated lesions than reported previously in MRI studies. Cite this article: Bone Joint J 2014;96-B:1631–6


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 643 - 648
1 May 2013
Wang J Hsu C Huang C Lin P Chen W

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft.

We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft–host junctions were packed with cancellous autograft.

At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required.

The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft.

Cite this article: Bone Joint J 2013;95-B:643–8.


Bone & Joint Research
Vol. 2, Issue 1 | Pages 1 - 8
1 Jan 2013
Costa AJ Lustig S Scholes CJ Balestro J Fatima M Parker DA

Objectives

There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design.

Methods

A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported.

The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured.

One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (sd 5.3), the mean Objective American Knee Society score was 91 (sd 13.9) and the mean Functional American Knee Society score was 90 (sd 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group.

Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 638 - 641
1 May 2012
Ha C Na S

We aimed to obtain anthropometric data on Korean knees and to compare these with data on commonly available total knee arthroplasties (TKAs). The dimensions of the femora and tibiae of 1168 knees were measured intra-operatively. The femoral components were found to show a tendency toward mediolateral (ML) under-coverage in small femurs and ML overhang in the large femurs. The ML under-coverage was most prominent for the small prostheses. The ML/anteroposterior (ML/AP) ratio of Korean tibiae was greater than that of tibial components.

This study shows that, for different reasons, current TKAs do not provide a reasonable fit for small or large Korean knees, and that the ‘gender-specific’ and ‘stature-specific’ components help for large Korean femurs but offer less satisfactory fits for small femurs. Specific modifications of prostheses are needed for Asian knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1118 - 1121
1 Aug 2011
Berber O Dawson-Bowling S Jalgaonkar A Miles J Pollock RC Skinner JA Aston WJS Briggs TWR

We describe 22 cases of bizarre parosteal osteochondromatous proliferation, or Nora’s lesion. These are surface-based osteocartilaginous lesions typically affecting the hands and feet. All patients were identified from the records of a regional bone tumour unit and were treated between 1985 and 2009. Nine lesions involved the metacarpals, seven the metatarsals, one originated from a sesamoid bone of the foot and five from long bones (radius, ulna, tibia, and femur in two). The mean age of the patients was 31.8 years (6 to 66), with 14 men and eight women. Diagnosis was based on the radiological and histological features. The initial surgical treatment was excision in 21 cases and amputation of a toe in one. The mean follow-up was for 32 months (12 to 162). Recurrence occurred in six patients (27.3%), with a mean time to recurrence of 49 months (10 to 120). Two of the eight patients with complete resection margins developed a recurrence (25.0%), compared with four of 14 with a marginal or incomplete resection (28.6%).

Given the potential surgical morbidity inherent in resection, our data suggest that there may be a role for a relatively tissue-conserving approach to the excision of these lesions.