Advertisement for orthosearch.org.uk
Results 1 - 20 of 220
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 4 - 4
11 Oct 2024
Sattar M Lennox L Lim JW Medlock G Mitchell M
Full Access

The Covid-19 pandemic restricted access to elective arthroplasty theatres. Consequently, there was a staggering rise in waiting times for patients awaiting total hip arthroplasty (THA). Concomitantly, rapidly destructive osteoarthritis (RDOA) incidence also increased. Two cohorts of patients were reviewed: patients undergoing primary THA, pre-pandemic (December 2017-December 2018) and patients with RDOA (ascertained by dual consultant review of pre-operative radiographs) undergoing THA after the pandemic started (March 2020 – March 2022). There were 236 primary THA cases in the pre-pandemic cohort. Out of the 632 primary THA cases post-pandemic, 186 cases (29%) had RDOA. Within this RDOA cohort, the pre-operative mean OHS, EQ5D3L and EQVAS (12.7, 10.5 and 57.6 respectively) were all poorer than in the pre-pandemic population (18.3, 9.4 and 66.7 respectively) (p<0.05). There was no significant difference between the RDOA and pre-pandemic cohort in Patient Reported Outcome Measures (PROMS) at 12 months, perhaps due to their ceiling effect. Within the RDOA cohort, 7 cases required acetabular augments, 1 of which also required femoral shortening. The rate of intra-operative fracture, dislocation, infection, return to theatre, and revision were 2.2%, 2.7%, 4.3%, 3.8% and 2.2% respectively, greater than those reported in the literature. No fractures nor dislocations occurred in robot assisted arthroplasties. With ever increasing waiting lists, RDOA prevalence will continue to rise. Increased surgical challenges and potential use of additional implants generated by its presence excludes these patients from waiting list initiative pathways, potentiating the complexity of the operative procedure. Going forwards, the economic burden and training implications must be considered


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 129 - 129
4 Apr 2023
Adla P Iqbal A Sankar S Mehta S Raghavendra M
Full Access

Intraoperative fractures although rare are one of the complications known to occur while performing a total hip arthroplasty (THA). However, due to lower incidence rates there is currently a gap in this area of literature that systematically reviews this important issue of complications associated with THA. Method: We looked into Electronic databases including PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), the archives of meetings of orthopaedic associations and the bibliographies of included articles and asked experts to identify prospective studies, published in any language that evaluated intra-operative fractures occurring during total hip arthroplasty from the year 1950-2020. The screening, data extraction and quality assessment were carried out by two researchers and if there was any discrepancy, a third reviewer was involved. Fourteen studies were identified. The reported range of occurrence of fracture while performing hip replacement surgery was found to be 0.4-7.6%. Major risk factors identified were surgical approaches, Elderly age, less Metaphyseal-Diaphyseal Index score, change in resistance while insertion of the femur implants, inexperienced surgeons, uncemented femoral components, use of monoblock elliptical components, implantation of the acetabular components, patients with ankylosing spondylitis, female gender, uncemented stems in patients with abnormal proximal femoral anatomy and with cortices, different stem designs, heterogeneous fracture patterns and toothed design. Intraoperative fractures during THA were managed with cerclage wire, femoral revision, intramedullary nail and cerclage wires, use of internal fixation plates and screws for management of intra operative femur and acetabular fractures. The main reason for intraoperative fracture was found to be usage of cementless implants but planning and timely recognition of risk factors and evaluating them is important in management of intraoperative fractures. Adequate surgical site exposure is critical especially during dislocation of hip, reaming of acetabulum, impaction of implant and preparing the femoral canal for stem insertion. Eccentric and increased reaming of acetabulum to accommodate a larger cup is to be avoided, especially in females and elderly patients as the acetabulum is thinner. However, this area requires more research in order to obtain more evidence on effectiveness, safety and management of intraoperative fractures during THA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 29 - 29
1 May 2021
Rouse B Giles S Fernandes J
Full Access

Introduction. We have previously published limb lengthening using external fixation in pathological bone diseases. We would like to report a case series of femoral lengthening using the PRECICE system in a similar pathological group especially looking at it's feasibility and complications. Materials and Methods. This is a case series of four patients, two patients with osteogenesis imperfecta and two with Ollier's disease, who underwent femoral lengthening via distraction osteogenesis using the PRECICE intramedullary nail system. It was a retrospective study from a prospective database from clinical records and radiographs. Results. The mean age at the time of surgery was 15.5 years, the mean preoperative leg length discrepancy was 30mm, and the mean distraction distance achieved was 28.75mm. Since these patients were of shorter heigh, limb lengthening was considered. All 4 patients had successful insertion of the nail. The outcomes noted from the 4 patients are collated, with several complications occurring including delayed femoral union, fixed flexion deformity of the hip, persisting pain and quadriceps weakness. Those with Ollier's disease underwent an increased rate of distraction to prevent premature healing. The implications of long-term bisphosphonate therapy in OI are discussed with regards to the risk of delayed femoral union and intra-operative fracture. Conclusions. Intramedullary femoral lengthening in pathological bone disease is possible, but the surgeon needs to give attention to certain details. The regenerate formation is based on the background pathology irrespective of the hardware used. There is much more compliance with the nail technique


Bone & Joint 360
Vol. 9, Issue 4 | Pages 15 - 17
1 Aug 2020


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 24 - 24
1 Jul 2020
Di Laura A Henckel J Belzunce M Hothi H Hart A
Full Access

Introduction. The achieved anteversion of uncemented stems is to a large extent limited by the internal anatomy of the bone. A better understanding of this has recently become an unmet need because of the increased use of uncemented stems. We aimed to assess plan compliance in six degrees of freedom to evaluate the accuracy of PSI and guides for stem positioning in primary THAs. Materials and Methods. We prospectively collected 3D plans generated from preoperative CTs of 30 consecutive THAs (17 left and 13 right hips), in 29 patients with OA, consisting of 16 males and 13 females (median age 68 years, range 46–83 years). A single CT-based planning system and cementless type of implant were used. Post operatively, all patients had a CT scan which was reconstructed using state-of-the-art software solution: the plan and CT reconstruction models were. Outcome measures: 1) discrepancy between planned and achieved stem orientation angles Fig.2&3; 2) clinical outcome. Results. 1) The mean (±SD) discrepancy was low for: Varus-valgus −1.1 ± 1.4 deg (IQR −2.2 – 0.3 deg); Anterior-posterior 0.1 ± 1.6 deg (IQR −0.7 – 1.3 deg). The discrepancy was higher for femoral version −1.4 ± 8.2 deg (IQR −8.3 – 7.2 deg). 3D-CT planning correctly predicted sizes in 93% of the femoral components. 2) There was no intra-operative fracture, no case showed evidence of early periprosthetic osseous injury. Discussion. Surgeons and engineers should be cautious with their expectation of achieving the planned femoral stem version of an uncemented femoral stem from the pre-operative 3D-CT plan. Conclusion. This is the first study to 3D-mensionally evaluate 3D-printed patient-specific instrumentation and guides for achieved femoral stem component orientation vis-à-vis to the plan. The tools allow accurate implant orientation, however there is still potential for improvement. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 60 - 60
1 Feb 2020
Kaper B
Full Access

Introduction/Aim. The NAVIO robotic-assisted TKA (RA-TKA) application received FDA clearance in May 2017. This semi-active robotic technique aims to improve the accuracy and precision of total knee arthroplasty. The addition of robotic-assisted technology, however, also introduces another potential source of surgery-related complications. This study evaluates the safety profile of NAVIO RA-TKA. Materials and Methods. Beginning in May 2017, the first 250 patients undergoing NAVIO RA-TKA were included in this study. All intra-operative complications were recorded, including: bleeding; neuro-vascular injury; peri-articular soft tissue injury; extensor mechanism complications; and intra-operative fracture. During the first 90 days following surgery, patients were monitored for any post-operative complications, including: superficial and deep surgical site infection; pin-tract infection; pin site fractures; peri-prosthetic fractures; axial or sagittal joint instability; axial mal-alignment; patello-femoral instability; DVT/PE; re-operation or re-admission due to surgical-related complications. Surgical technique and multi-modality pain management protocol was consistent for all patients in the study. A combined anesthetic technique was employed for all cases, including: low-dose spinal, adductor canal block and general anesthetic. Patients were mobilized per our institution's rapid recovery protocol. Results. No patients were lost to follow-up. During the study period, no intra-operative complications were recorded. Specifically, no complications related to the introduction of the high-speed burr associated with the NAVIO RA-TKA were noted. Within the 90-day follow-up period, there was one case of deep infection. One patient sustained a fall resulting in a peri-prosthetic femoral fracture, that occurred remote from the femoral pin tracts. No cases of axial or sagittal joint instability, axial mal-alignment, patello-femoral instability, pin site infections or fractures; or DVT/PE were identified. Four patients underwent manipulation under anesthesia. No other patients required a re-operation or re-admission due to surgical-related complications. Discussion/Conclusions. The initial experience with the NAVIO robotic assisted total knee arthroplasty has demonstrated excellent safety profile. Relative to known risks associated with total knee arthroplasty, no increased risk of peri-operative complications, re-operation or re-admission for surgical related complications was identified with the introduction of the NAVIO RA-TKA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 62 - 62
1 Jun 2018
Garbuz D
Full Access

The goals of revision total hip on the femoral side are to achieve long term stable fixation, improve quality of life and minimise complications such as intra-operative fracture or dislocation. Ideally these stems will preserve or restore bone stock. Modular titanium stems were first introduced in North America around 2000. They gained popularity as an option for treating Paprosky 3B and 4 defects. Several studies at our institution have compared modular titanium stems with monoblock cobalt chromium stems. The main outcomes of interest were quality of life. We also looked at complications such as intra-operative fracture and post-operative dislocation. We also compared these 2 stems with respect to restoration or preservation of bone stock. In 2 studies we showed that modular titanium stems gave superior functional outcomes as well as decreased complications compared to a match cohort of monoblock cobalt chromium stems. As mentioned, one of the initial reasons for introduction of these stems was to address larger femoral defects where failure rates with monoblock cobalt chromium stems were unacceptably high. We followed a group of 65 patients at 5–10 years post revision with a modular fluted titanium stem. Excellent fixation was obtained with no cases of aseptic loosening. However, there were 5 cases of fracture of the modular junction. Due to concerns of fracture of the modular junction, more recently, at our institution, we have switched to almost 100% monoblock fluted titanium stems. We recently reviewed our first 100 cases of femoral revision with a monoblock stem. Excellent fixation was achieved with no cases of aseptic loosening. Quality of life outcomes were similar to our previous reported series on modular tapered titanium stems. Both monoblock and modular fluted titanium stems can give excellent fixation and excellent functional outcomes. This leaves a choice for the surgeon. For the low volume revision surgeon modular tapered stems are probably the right choice. Higher volume surgeons or surgeons very comfortable with performing femoral revision may want to consider monoblock stems. If one is making the switch it would be easiest to start with a simple case. Such a case would be one that can be done with a endofemoral approach. In this approach the greater trochanter is available as the key landmark for reaming. After the surgeon is comfortable with this stem more complex cases can easily be handled with the monoblock stem. In summary, both modular and monoblock titanium stems are excellent options for femoral revision. As one becomes more familiar with the monoblock stem it can easily become your workhorse for femoral revision. At our institution we introduced a monoblock titanium stem in 2011. It started out at 50% of cases and now it is virtually used in almost 100% of revision cases


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 19 - 19
1 Jun 2018
Garbuz D
Full Access

Intra-operative fractures of the femur are on the rise mainly due to the increased use of cementless implants and the desire to get a tight press fit. The prevalence has been reported to be between 1–5% in cementless THAs. The key to preventing these fractures is to identify patients at high risk and careful surgical technique. Surgical risk factors include the use of cementless devices, revision hip surgery, the use of flat tapered wedges and MIS surgery. Patient factors that increased risk include increasing age, female gender, osteopenia and rheumatoid arthritis. These risk factors tend to be additive and certainly when more than one is present extra caution needs to be taken. Surgical technique is critical to avoid these intra-operative fractures. Fractures can occur during exposure and dislocation, during implant removal (in revision THA), during canal preparation and most commonly during stem insertion. In both primary, and especially in revision, THA be wary of the stiff hip in association with osteopenia or osteolysis. These patients require a very gentle dislocation. If this cannot be achieved, then alteration of the standard approach and dislocation may be needed. Examples of these include protrusion with an osteopenic femur and revision THA with a very stiff hip with lysis in the femur. Lastly, in cases with retained hardware, dislocate prior to removing plates and screws. After dislocation, the next challenge is gentle preparation of the femoral canal. A reasonable exposure is required to access the femoral canal safely. MIS procedures do not offer good access to femoral canal and this probably results in increased risk of fracture during broaching or implant insertion. When broaching, stop when broach will not advance further. When inserting a tapered wedge stem, be worried if stem goes further in than broach. In revision surgery, when taking the stem out from above, make sure the area of the greater trochanter does not overhang the canal. A high speed burr can clear the shoulder for easier access for removal. In revision THA with an ETO, place a cerclage wire prior to reaming and retighten prior to stem insertion. Even with careful surgical technique intra-operative femoral fractures will still occur. When inserting the stem, a sudden change in resistance is highly suggestive of fracture. Wide exposure of the entire proximal femur is necessary to confirm the diagnosis. The distal extent of the fracture must be seen. Only on occasion is an intra-operative radiograph needed. Management is directed to ensuring component stability and good fracture fixation. In primary total hip arthroplasty, calcar fractures are by far the most common. If using proximal fixation and you are certain the stem is stable, then all that is needed is cerclage wiring. As already mentioned, you must follow the fracture line distally so you are aware of how far down it goes. Often what appears to be a calcar split actually propagates distal to the lesser trochanter. In these cases, one would probably go for distal fixation plus wiring. In conclusion, intra-operative femoral fractures are on the rise. Prevention is the key


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 71 - 71
1 Apr 2018
Hood B Nelson J Lewis R Urquhart A Maratt J
Full Access

The purpose of this study is to assess the accuracy of component positioning and incidence of peri-operative and 90-day post-operative complications following robotic arm-assisted and conventional total hip arthroplasty (THA). Three groups of patients were analyzed for this study: those that underwent conventional THA performed by Surgeon 1, conventional THA performed by Surgeon 2, or robotic arm-assisted THA performed by Surgeon 2. All patients underwent primary uncemented THA via a posterior approach. Patient characteristics, intra-operative data, and 90-day post-operative complications were collected. Post-operative standing pelvic radiographs were utilized to measure acetabular position and to identify post-operative complications. Acetabular component position measurements revealed substantially less variation in both inclination and anteversion in the Surgeon 2 – Robotic group. Nine patients had intra-operative cables placed for intra-operative calcar fracture in the Surgeon 1 group compared to one patient and three patients in Surgeon 2 – Robotic and Surgeon 2 – Traditional groups, respectively. Nine instances of femoral stems subsidence were identified in the Surgeon 1 group compared to one patient in Surgeon 2 – Traditional. There were four instances of dislocation in the Surgeon 1 group compared to one in the Surgeon 2 – Robotic group. Robotic arm-assisted THA decreases the variation in acetabular component positioning compared to conventional THA. However, the benefit of this is unclear as there is little difference in dislocation rate. This study may demonstrate additional value in CT-based implant planning as this cohort had the lowest incidence of femoral component complications


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 17 - 21
1 Jan 2018
Konan S Duncan CP

Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation.

In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival.

Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication.

Cite this article: Bone Joint J 2018;100-B(1 Supple A):17–21.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 14 - 16
1 Dec 2017


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 96 - 96
1 Aug 2017
Garbuz D
Full Access

The goals of revision total hip on the femoral side are to achieve long term stable fixation, improve quality of life and minimise complications such as intra-operative fracture or dislocation. Ideally these stems will preserve or restore bone stock. Modular titanium stems were first introduced in North America around 2000. They gained popularity as an option for treating Paprosky 3B and 4 defects. Several studies at our institution have compared the modular titanium stems with monoblock cobalt chromium stems. The main outcomes of interest were quality of life. We also looked at complications such as intra-operative fracture and post-operative dislocation. We also compared these 2 stems with respect to restoration or preservation of bone stock. In 2 studies we showed that modular titanium stems gave superior functional outcomes as well as decreased complications compared to a match cohort of monoblock cobalt chromium stems. As mentioned one of the initial reasons for introduction of these stems was to address larger femoral defects where failure rates with monoblock cobalt chromium stems were unacceptably high. We followed a group of 65 patients at 5–10 years post-revision with a modular fluted titanium stem. Excellent fixation was obtained with no cases of aseptic loosening. However, there were 5 cases of fracture of the modular junction. Due to concerns of fracture of the modular junction more recently at our institution we have switched to almost 100% monoblock fluted titanium stems. We recently reviewed our first 100 cases of femoral revision with monoblock stem. Excellent fixation was achieved with no cases of aseptic loosening. Quality of life outcomes were similar to our previous reported series on modular tapered titanium stems. Both monoblock and modular fluted titanium stems can give excellent fixation and excellent functional outcomes. This leaves a choice for the surgeon. For the low volume revision surgeon modular tapered stems are probably the right choice. Higher volume surgeons or surgeons very comfortable with performing femoral revision may want to consider monoblock stems. If one is making the switch it would be easiest to start with a simple case. Such a case would be one that can be done with an endofemoral approach. In this the greater trochanter is available as the key landmark for reaming. After the surgeon is comfortable with this stem more complex cases can easily be handled with the monoblock stem. In summary, both modular and monoblock titanium stems are excellent options for femoral revision. As one becomes more familiar with the monoblock stem it can easily become your workhorse for femoral revision. At our institution we introduced a monoblock titanium stem in 2011. It started out at 50% of cases and now it is virtually used in almost 100% of revision cases


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 958 - 963
1 Jul 2017
Mamarelis G Key S Snook J Aldam C

Aims

Hip hemiarthroplasty is a standard treatment for intracapsular proximal femoral fractures in the frail elderly. In this study we have explored the implications of early return to theatre, within 30 days, on patient outcome following hip hemiarthroplasty.

Patients and Methods

We retrospectively reviewed the hospital records of all hip hemiarthroplasties performed in our unit between January 2010 and January 2015. Demographic details, medical backround, details of the primary procedure, complications, subsequent procedures requiring return to theatre, re-admissions, discharge destination and death were collected.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 749 - 758
1 Jun 2017
García-Rey E Cruz-Pardos A García-Cimbrelo E

Aims

To determine the effect of a change in design of a cementless ceramic acetabular component in fixation and clinical outcome after total hip arthroplasty

Patients and Methods

We compared 342 hips (302 patients) operated between 1999 and 2005 with a relatively smooth hydroxyapatite coated acetabular component (group 1), and 337 hips (310 patients) operated between 2006 and 2011 using a similar acetabular component with a macrotexture on the entire outer surface of the component (group 2). The mean age of the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70) in group 2. The mean follow-up was 12.7 years (10 to 17) for group 1 and 7.2 years (4 to 10) for group 2.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 18 - 18
1 Jun 2017
Wilson S Unsworth R Ajwani S Sochart D
Full Access

Litigation costs are significant and increasing annually within the National Health Service (NHS) in England. The aim of this work was to evaluate the burden of successful litigation relating to hip surgery in England. Secondary measures looked at identifying the commonest causes of successful legal action. A retrospective review was conducted on the National Health Service Litigation Authority (NHSLA) database. All successful claims related to hip surgery over a 10 year period from 2003–2013 were identified. A total of 798 claims were retrieved and analysed. The total cost of successful claims to the NHS was £66.3 million. This compromised £59 million in damages and £7.3 million in NHS defence-related legal costs. The mean damages for settling a claim were £74,026 (range £197-£1.6million). The commonest cause of claim was post-operative pain with average damages paid in relation to this injury being £99,543. Nerve damage and intra-operative fractures were the next commonest cause of claim with average damages settled at £103,465. Legal action in relation to hip surgery is a considerable source of cost to the NHS. The complexity of resolving these cases is reflected in the associated legal costs which represent a significant proportion of payouts. With improved understanding of factors instigating successful legal proceedings, physicians can recognise areas where practice and training need to be improved and steps can be taken to minimise complications leading to claims


Bone & Joint 360
Vol. 6, Issue 3 | Pages 10 - 12
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims

In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder.

Patients and Methods

All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 440 - 444
1 Apr 2017
Lee KH Jo W Ha YC Lee YK Goodman SB Koo KH

Aims. Modular or custom-made femoral components have been preferred for total hip arthroplasty (THA) in patients with a history of Perthes’ disease because of the distortion in the anatomy of the proximal femur. However, it has not been established whether a monobloc cementless stem will fit the distorted proximal femur or whether the results of the procedure are satisfactory in this group of patients. Patients and Methods. We reviewed 68 consecutive patients who had undergone THA for childhood Perthes’ disease between June 2003 and December 2008. There were 35 men and 33 women with a mean age of 48 years (16 to 73) at the time of index arthroplasty. Their mean body mass index was 24.4 (18.3 to 32.9). Of the 68 hips, 32 were classified as Stulberg class III and 36 as class IV. The mean pre-operative shortening of the affected leg was 17.2 mm (5 to 34). The minimum follow-up was five years (mean 8.5 years; 5.2 to 10). Results. An intra-operative calcar fracture occurred in eight hips (11.8%) and was successfully treated by cerclage wiring. The mean stem version was 14.6° (-2.3 to 30; standard deviation (. sd. ) 7.3). The mean acetabular component abduction was 40.2° (23.7 to 56.0; . sd. 6.5) and the mean anteversion 28.3° (6.4 to 43.0; . sd. 7.6), respectively. The mean follow-up was 8.5 years (5.2 to 10). No dislocations occurred and no hips were revised during the course of the study. At final follow-up, the mean Harris Hip Score was 91 points (59 to 100) and the mean University of California, Los Angeles activity score was 3.2 (2 to 8). Conclusion. Monobloc cementless stems reliably restore the anatomy in Perthes’ disease at THA without the need for custom-made or modular implants. Cite this article: Bone Joint J 2017;99-B:440–444


Bone & Joint 360
Vol. 6, Issue 2 | Pages 14 - 17
1 Apr 2017