Background. Charcot neuroarthropathy is a destructive disease characterized by progressive bony fragmentation as a result of the isolated or accumulative trauma in patients with decreased sensation that manifests as dislocation, periarticular fractures and instability. Although amputation can be a reasonable cost economic solution, many patients are willing to avoid that if possible. We explored here one of the salvage procedures. Methods. 23 patients with infected ulcerated unstable Charcot neuroarthropathy of the ankle were treated between 2012 and 2017. The mean age was 63.5 ±7.9 years; 16 males and 7 females. Aggressive open debridement of ulcers and joint surfaces, with talectomy in some cases, were performed followed by external fixation with an
By utilising the inherent variability achievable with circular frames, surgeons can manage a wide spectrum of complex injuries, and can deal with deformity at multiple levels, in multiple planes. The aim of this study was to assess functional outcomes utilising patients reported outcome measures (PROMs) of patients being treated with circular (Ilizarov) frame fixation for complex lower limb injuries and assess these results in conjunction with the observed postoperative alignment of the patients’ limbs. Cases were identified using a prospectively collected database of adult patients presenting between July 2018 and August 2021. Functional outcomes were assessed using the American Orthopaedic Foot and Ankle Score (AOFAS), the 5-level EQ-5D (EQ5D5L), the Lysholm Knee Scoring Scale (LKSS), the Olerud-Molendar Ankle Score (OMAS), and the Tegner Activity Scale (TAS). Postoperative radiographs were analysed for fracture union and to quantify malunion (as described in Dror Paleys Principles of Deformity Correction).Introduction
Materials & Methods
Introduction. Traditionally, radiological union of fractures treated with an
Aim. This study assessed quality of life (QoL) in patients having external fixation for treatment of osteomyelitis and fracture-related infection (OM/FRI). Method. Patients who had surgery for OM/FRI and who completed the EuroQoL EQ-5D-5L or EQ-5D- 3L questionnaires, were identified between 2010 and 2020. Patients were followed-up for 2 years after surgery. QoL was compared between patients who had either an
Abstract. OBJECTIVES. To determine if force measured using a strain gauge in circular external fixation frames is different for 1) different simulated stages of bone healing, and for 2) fractures clinically deemed either united or un-united. METHODS. In a laboratory study, 3 similar
Dead-space management, following dead bone resection, is an important element of successful chronic osteomyelitis treatment. This study compared two different biodegradable antibiotic carriers used for dead-space management, and reviewed clinical and radiological outcomes. All cases underwent single-stage surgery and had a minimum one-year follow-up. A total of 179 patients received preformed calcium sulphate pellets containing 4% tobramycin (Group OT), and 180 patients had an injectable calcium sulphate/nanocrystalline hydroxyapatite ceramic containing gentamicin (Group CG). Outcome measures were infection recurrence, wound leakage, and subsequent fracture involving the treated segment. Bone-void filling was assessed radiologically at a minimum of six months post-surgery.Aims
Methods
The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for limb lengthening in children. In this study, there were 59 consecutive tibial lengthening and deformity corrections in 57 children using a circular frame. All were performed or supervised by the senior author between January 2013 and June 2019. A total of 25 who underwent a distal tibial osteotomy were analyzed and compared to a group of 34 who had a standard proximal tibial osteotomy. For each patient, the primary diagnosis, time in frame, complications, and lengthening achieved were recorded. From these data, the frame index was calculated (days/cm) and analyzed.Aims
Methods
The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.Aims
Methods
Introduction. This study aims to evaluate the effect of using different types of fixator on the quality of callus and complications during distraction osteogenesis in patients with achondroplasia. Materials and Methods. Forty-nine achondroplasia patients with a minimum follow-up of 36 months who underwent limb lengthening between 2005 and 2017 with external fixator only were included. Thirty-three of the patients underwent lengthening using classical
Introduction. Despite all modern advances the indications and possibilities of treatment in Legg-Calvé-Perthes Disease (LCPD) are still controversial. In the past 15 years we started using arthrodiastasis of the hip creating negative pressure over the avascular femoral head in some selected cases of LCPD in the active phasis of the disease. Now we present our experience with distraction in LCPD using the original
Introduction. Orthopaedic rehabilitation of adolescences and young adults with high dislocation of the femur is rather challenging. The role of palliative salvage procedures is controversial enough in the cohort of patients. Materials and Methods. Treatment outcomes of 10 patients with congenital hip dislocation were analyzed. Mean age at intervention was 17,8 years (15–22). The grade of dislocation were assessed according to Eftekhar: type C − 2, type D − 8. The mean baseline shortening was 4.7±0.36 cm. All subjects underwent PSO with the Ilizarov method. Another osteotomy for lengthening and realignment was produced at the boundary of the upper and middle third of the femur. The mean time in the
Management of gap non-union of the tibia, the major weight bearing bone of the leg remains controversial. The different internal fixation techniques are often weighed down by relatively high complication rates that include fractures which fail to heal (non-union). Minimally invasive techniques with ring fixators and bone transport (distraction osteogenesis) have come into picture as an alternative allowing alignment and stabilization, avoiding a graduated approach. This study was focused on fractures that result in a gap non-union of > 6 cm. Ilizarov technique was employed for management of such non-unions in this case series. The Ilizarov apparatus consists of rings, rods and kirschner wires that encloses the limb as a cylinder and uses kirschner wires to create tension allowing early weight bearing and stimulating bone growth. Ilizarov technique works on the principle of distraction osteogenesis, that is, pulling apart of bone to stimulate new bone growth. Usually, 4–5 rings are used in the setup depending on fracture site and pattern for stable fixation. In this study, we demonstrate effective bone transport and formation of gap non-union more than 6 cm in 10 patients using only 3 rings construct Ilizarov apparatus. This case study was conducted at Dr. D. Y. Patil Medical Hospital, Navi Mumbai, Maharashtra, India. The study involved 10 patients with a non-union or gap > 6 cm after tibial fracture. 3 rings were used in the setup for the treatment of all the patients. Wires were passed percutaneously through the bone using a drill and the projecting ends of the wires were attached to the metal rings and tensioned to increase stability. The outcome of the study was measured using the Oxford Knee scoring system, Functional Mobility Scale, the American Foot and Ankle Score and Visual Analog Scale. Further, follow up of patients was done upto 2 years.Introduction and Objective
Materials and Methods
Introduction. In my paediatric Orthopaedic practice I use Kirchner wires for the fixation of the TSF on bone. I noted a significant percentage of wire loosening during the post-operative period. The aim of this project was to establish the effectiveness of the wire clamping mechanism and find ways to reduce the incidence of wire loosening when using the TSF. Materials and Methods. In the first instance wire slippage was measured intra-operatively after the tensioner was removed using an intra-operative professional camera. Following this study mechanical tests were performed in the lab measuring the pull out properties of Kirchner wires using different bolts and different torque levels in order to tighten the wire on the fixator. Results. Our clinical study confirmed wire slippage intra-operatively immediately after the tensioner was removed. Wire slippage after the tensioner was removed was found to vary from 0.01 mm to 0.51 mm (mean 0.19 mm). Our mechanical tests showed that the ideal torque for tightening the wire on the frame using a bolt was around 15 N.m. A comparison between cannulated and slotted bolts suggested that cannulated bolts are more effective as a clamping mechanism. A comparison between aluminium made Taylor Spatial frame rings and stainless steel made Ilizarov rings suggested that the Taylor Spatial frame rings are more effective as part of a clamping mechanism. Conclusions. It is important that clinicians routinely measure the torque they use to clamp wires on circular external fixators. Clinicians and manufacturers are informed that the type of bolt used is important in maintaining wire tension. Manufacturers should design the ideal bolt which effectively grips the wire without the risk of fracture. The
Introduction. Deformity influences the weight bearing stresses on the knee joint. Correction of mechanical alignment is performed to offload the knee and slow the rate of degenerative change. Fixator assisted deformity correction facilitates accurate correction prior to internal fixation. We present our results with standard Ilizarov and UNYCO system assisted deformity correction of the lower limb. Materials and Methods. Retrospective analysis of adult surgical cases of mechanical re-alignment performed between 2010 and 2019 in a tertiary referral centre. We recorded standard demographics and operative time from the electronic patient record. We analysed digitalised radiographs to record pre- and post-operative measurements of: Mechanical axis deviation (MAD), femoral tibial angle (FTA), Medial Proximal tibial angle (MPTA) and Mechanical lateral distal femoral angle (mLDFA). The accuracy of the correction was analysed. Time to healing, secondary interventions and complications were also recorded. Results. 7 patients underwent fixator assisted deformity correction with the UNYCO system and 11 with a standard
The aim of the study is to evaluate the results of using Ilizarov technique for correcting the post traumatic lower limb deformities. This prospective study included 25 femurs (Group A) and 65 tibias (Group B) underwent correction with Ilizarov technique and frame. Both groups had moderate and complex deformed segments. Outcomes were Ilizarov correction time, distraction index (DI), consolidation index (CI), Ilizarov index (II) and complications.Introduction
Materials and Methods
Introduction. Ashford and St Peter's Hospital (ASPH) is a district general hospital in Chertsey, Surrey. It is a tertiary referral unit offering a circular frame service to manage complex trauma patients in the South East of England. This study analyses the patient pathway in 66 consecutive tertiary referrals from 2015–2020. All patients were managed with an
Introduction. The BOAST (British Orthopaedic Association Standards for Trauma) guidelines do advise that open pilon fractures amongst other open lower limb fractures need to be treated at a specialist centre with Orthoplastic care. The purpose of this study was to determine clinical outcomes in patients with open pilon fractures treated as per BOAST guidelines including relatively aggressive bone debridement. Methods. A retrospective analysis of a single surgeon series of open pilon fractures treated between 2014 and 2019 was conducted. Injuries were graded according to the Gustillo-Anderson classification and all patients were included for the assessment of the rate of infection and fracture healing. Functional outcome assessment was performed in all patients according to the American Orthopedic Foot and Ankle Score (AOFAS) at 6 months after definitive surgery. Initial wound with bone debridement and application of a spanning external fixator was performed within an average of 13.5 (Range: 3–24) hours. Fixation with FWF (Fine Wire Frame) was performed when the wound was healed, with the mean time from primary surgery to application of FWF being 24.5 (Range: 7–60) days. Results. There was a total of 20 patients including 16 males and 4 females. The mean age was 50.45 (Range: 16–88) years. Follow-up was for an average of 23.2 (Range: 5–51) months. There were 3 patients with Gustilo Type I injuries, 6 with Type II, 4 Type with type IIIa and 7 with Type IIIb injuries. Average time to bone union was 9.3 (Range: 2–18) months. The mean AOFAS score was 66 (Range: 15–97) points. TSF was used on 18 patients, while 2 patients had an
To systematically review the outcomes and complications of cosmetic stature lengthening. PubMed and Embase were searched on 10 November 2019 by three reviewers independently, and all relevant studies in English published up to that date were considered based on predetermined inclusion/exclusion criteria. The search was done using “cosmetic lengthening” and “stature lengthening” as key terms. The Preferred Reporting Item for Systematic Reviews and Meta-Analyses statement was used to screen the articles.Aims
Methods