The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis.Aims
Methods
Introduction. We have investigated middle-term clinical results of total hip arthroplasty (THA) cemented socket with improved technique using
Objectives. To explore the therapeutic potential of combining bone marrow-derived mesenchymal stem cells (BM-MSCs) and
Introduction. IBBC (interfacial bioactive bone cement method, Oonishi) (1) is an excellent technique for augmenting cement-bone fixation in the long term. However, the technique is difficult and there are concerns over some points, such as bleeding control, disturbance of cement intrusion to anchoring holes by granules, difficulty of the uniform granular dispersion to the acetabular bone (Zone 1 in particular). To improve this technique, we have modified IBBC (M-IBBC), and investigated the short-term clinical results and radiographic changes. Materials and Methods. K-MAX HS-3 THA (Kyocera Medical, Japan), with cemented stem and all polyethylene cemented socket, was used for THA implants. Basically the third generation cementing technique was used for THA using bone cement. The socket fixation was performed with bone cement (Endurance, DePuy) and
Between 1993 and 2003, 67 consecutive revision total hip arthroplasties were performed in 65 patients, including 52 women and 13 men, using
Purpose. One of the drawbacks of cemented total hip arthroplasty (THA) is aseptic loosening after long period, major reason for which is bioinertness of PMMA bone cement. To improve longevity of THA, interface bioactive bone cement (IBBC) technique which is characterized with smearing
Purpose. We have compared the short-term clinical results of total hip arthroplasty (THA) using PMMA bone cement and
INTRODICTION. Since 1985, not resorbable crystalline osteoconductive
INTRODUCTION. We have conducted interface bioactive bone cement method (IBBC) in total hip arthoplasty (THA) to prevent generation of connective tissue and osteolysis for the longevity of cemented THA since 1985, in which non-resorbable crystalline osteoconductive
In revision total hip arthroplasty (THA), it is essential to cope with the bone stock loss. The acetabular bone loss is reconstructed by bulk bone grafts, bone chips, bone cement or jumbo cup. The impaction bone-grafting (IBG) technique is a technique that can restore acetabular bone loss, while enough bone allografts are not easy to obtain and the quality is not always sufficient. Thus we mixed
The long-term results of grafting with hydroxyapatite granules for acetabular deficiency in revision total hip replacement are not well known. We have evaluated the results of revision using a modular cup with hydroxyapatite grafting for Paprosky type 2 and 3 acetabular defects at a minimum of ten years’ follow-up. We retrospectively reviewed 49 acetabular revisions at a mean of 135 months (120 to 178). There was one type 2B, ten 2C, 28 3A and ten 3B hips. With loosening as the endpoint, the survival rate was 74.2% (95% confidence interval 58.3 to 90.1). Radiologically, four of the type 3A hips (14%) and six of the type 3B hips (60%) showed aseptic loosening with collapse of the hydroxyapatite layer, whereas no loosening occurred in type 2 hips. There was consolidation of the hydroxyapatite layer in 33 hips (66%). Loosening was detected in nine of 29 hips (31%) without cement and in one of 20 hips (5%) with cement (p = 0.03, Fisher’s exact probability test). The linear wear and annual wear rate did not correlate with loosening. These results suggest that the long-term results of hydroxyapatite grafting with cement for type 2 and 3A hips are encouraging.
Improved cement technique by interposing less than two layers of