Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 62 - 62
2 May 2024
Afzal S Sephton B Wilkinson H Hodhody G Ammori M Kennedy J Hoggett L Board T
Full Access

Total Hip Arthroplasty (THA) and Hip Hemiarthroplasties (HA) are successful, cost-effective procedures that improve quality of life. Dislocation is a well recognised complication with a significant health and economic burden. We aim to establish the current management practices across the United Kingdom (UK) for Prosthetic Hip Dislocations (PHD). Our definition of a PHD includes; THA, HA and revision THA. This national study builds on our regional pilot study and records one of the largest datasets of Prosthetic Hip Dislocation management within the UK. A trainee-led collaborative; the North West Orthopaedic Research Collaborative (NWORC). Conducted a retrospective audit, registered as Quality Improvement (QI) projects, collected data from 38 hospital trusts across the UK. Data was collected on patient-related factors, inpatient management, and outpatient follow up of each PHD episode between January and July 2019. Primary outcome measured definitive management, in the form of revision surgery or the consideration for this through a referral pathway. A total of 673 (THA 504, Revision THA 141, HA 28) patients were included with a total of 740 dislocation episodes. Mean age was 75.6 years with female to male ratio 2:1. The majority of PHDs were a result of a low energy mechanism (98.7%) and presented over 6 months post index procedure (80.5%). Over half (53.8%) attended with a first or second time dislocation. Only 29.9% patients received onward revision referral; whereas 70.1% followed diverse management patterns, including local non-arthroplasty and primary arthroplasty surgeon follow-ups. Revision THAs had higher rates of referral for revision (p<0.001) compared to primary THA and HA dislocations. A high number of PHDs present across the UK, with under a third receiving definitive management plans. This variation increases the economical burden to the National Health Service, highlighting the need for national guidance to manage these complex patients


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 20 - 20
1 Apr 2022
Afzal S Hodhody G Kennedy J Board T
Full Access

Total Hip Replacements (THR) and Hip Hemiarthroplasties (HA) are both successful and common orthopaedic procedures. Dislocation is a well-recognised complication carrying significant morbidity and, in some cases, increased mortality risks. We define prosthetic hip dislocations (PHDs) to include both THRs and HAs. Prosthetic Hip Dislocations (PHDs) are a common acute admission yet there are no published guidelines or consensus on management following reduction. A retrospective audit was undertaken by the North West Orthopaedic Research Collaborative (NWORC) between January 2019 and July 2019. A questionnaire was used to capture the management of each dislocation episode presenting to 11 Hospital trusts. The study was registered as a Quality Improvement (QI) project at each site. Data regarding the surgical management physiotherapy input, ongoing care and further management plans were recorded. A total of 183 patients with 229 dislocations were submitted for initial analysis (171 THRs, 10 HAs, 2 PFRs). Female to male ratio was 2:1 with mean age of 76.7 years. Average time to first dislocation was 8.1 years. 61.1% were first or second time dislocators and 38.9% presented with 3 or more dislocations. Initial reductions were predominantly attempted in theatre (96.5%, n=221) with only 3.5% (n=8) attempted in the emergency department. In theatre 89% (n=201) were reduced closed. There was no plan for revision surgery in 70.6% cases with no difference seen between patients with >=3 dislocations and <=2 dislocations. Of the patients with a revision plan, 71% of these were performed or planned locally. The high number of patients with 3 or more dislocations and the lack of plans for definitive interventions in the majority of cases highlights the significant variation in the management of this complex group of patients. This variation in the quality of care increases the burden on the National Health Service through repeat hospital episodes. We aim to roll out this study nationally to assess regional variations and ultimately make the case for national guidance on the management of prosthetic hip dislocations


Bone & Joint Open
Vol. 2, Issue 10 | Pages 806 - 812
1 Oct 2021
Gerritsen M Khawar A Scheper H van der Wal R Schoones J de Boer M Nelissen R Pijls B

Aims

The aim of this meta-analysis is to assess the association between exchange of modular parts in debridement, antibiotics, and implant retention (DAIR) procedure and outcomes for hip and knee periprosthetic joint infection (PJI).

Methods

We conducted a systematic search on PubMed, Embase, Web of Science, and Cochrane library from inception until May 2021. Random effects meta-analyses and meta-regression was used to estimate, on a study level, the success rate of DAIR related to component exchange. Risk of bias was appraised using the (AQUILA) checklist.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1447 - 1458
1 Nov 2019
Chatziagorou G Lindahl H Kärrholm J

Aims

We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis.

Patients and Methods

The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B periprosthetic femoral fracture between 2001 and 2011. The primary outcome measure was any further reoperation between 2001 and 2013. Cross-referencing with the National Patient Register was performed in two stages, in order to identify all surgical procedures not recorded on the SHAR.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 52 - 52
1 Jun 2017
Pradhan R Grammatopoulos G Wilson H Asopa V Andrade T
Full Access

A modular hemiarthroplasty has a Metal-on-Metal (MoM) taper-trunnion junction, which may lead to increased wear and Adverse-Reaction-to-Metal-Debris (ARMD). To-date no wear related issues have been described in the elderly and less active that receives a hemiarthroplasty. This study aims to determine in vivo wear (i.e. serum metal ion levels) in hip hemiarthroplasty, and identify factors associated with increased wear.

This is a prospective, IRB approved, single-centre, cohort study of patients that received an uncemented, modular hemiarthroplasty of proven design for the treatment of hip fracture between 2013–2015. All, alive, patients at 12-months post-implantation with AMTS≥6 were invited to participate. Of the 125 eligible patients, 50 accepted the invitation and were reviewed, including clinical/radiological assessment, metal-ion ([Chromium (Cr) and Cobalt (Co)]) measurement and Oxford Hip Score (OHS). Acetabular erosion was graded (0–3: normal-protrusio). Metal ion levels were considered high if ≥7ppb.

The mean OHS was 37 (SD: 10). No acetabular erosion was detected in 21, whilst the remaining had either grade-1 (n=21) or grade-2 (n=8). The median Cr and Co levels were 2.9 (SD:9) and 2.2 (SD:4) respectively. There were 8 cases (16%) with high ion levels. To-date only 2 of them has an ARMD lesion, and none have been revised. Patients with metal ion levels had similar pre-fall mobility, taper- and head- size and OHS to those with low metal ion levels (p=0.2–0.7) However, all hips with high metal ion levels had evidence of acetabular erosion (≥1).

Modular Hip hemiarthroplasties and their taper-trunnion junction are not immune to high wear and ARMD despite being implanted in a less active cohort. Acetabular erosion should alert clinicians, as it is associated with 20× increased-risk of taper wear, presumably due to the increased transmitted torque. Whether the use of modular hemiarthroplasties should remain is debatable.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1262 - 1269
1 Sep 2016
Pinder EM Bottle A Aylin P Loeffler MD

Aims

To determine whether there is any difference in infection rate at 90 days between trauma operations performed in laminar flow and plenum ventilation, and whether infection risk is altered following the installation of laminar flow (LF).

Patients and Methods

We assessed the impact of plenum ventilation (PV) and LF on the rate of infection for patients undergoing orthopaedic trauma operations. All NHS hospitals in England with a trauma theatre(s) were contacted to identify the ventilation system which was used between April 2008 and March 2013 in the following categories: always LF, never LF, installed LF during study period (subdivided: before, during and after installation) and unknown. For each operation, age, gender, comorbidity, socio-economic deprivation, number of previous trauma operations and surgical site infection within 90 days (SSI90) were extracted from England’s national hospital administrative Hospital Episode Statistics database. Crude and adjusted odds ratios (OR) were used to compare ventilation groups using hierarchical logistic regression. Subanalysis was performed for hip hemiarthroplasties.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 152 - 159
1 Feb 2016
Corbacho B Duarte A Keding A Handoll H Chuang LH Torgerson D Brealey S Jefferson L Hewitt C Rangan A

Aims

A pragmatic multicentre randomised controlled trial (PROFHER) was conducted in United Kingdom National Health Service (NHS) hospitals to evaluate the clinical effectiveness and cost effectiveness of surgery compared with non-surgical treatment for displaced fractures of the proximal humerus involving the surgical neck in adults.

Methods

A cost utility analysis from the NHS perspective was performed. Differences between surgical and non-surgical treatment groups in costs and quality adjusted life years (QALYs) at two years were used to derive an estimate of the cost effectiveness of surgery using regression methods.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 117 - 117
1 Dec 2015
Nayar D Hornsby J Aldridge C Scott S Longstaff L Jennings A Shaw N Duffy P
Full Access

Bone and joint infections of the lower limbs cause significant morbidity for patients. Infection is a devastating complication for prosthetic joint replacements. In this large case series from a single centre in the NE of England, we present our experience of using antibiotic impregnated dissolvable synthetic pure calcium sulphate beads [Stimulan R]1 for local elution of antibiotics at the site of infection. At our centre, from August 2012 to Jan 2015, antibiotic impregnated dissolvable synthetic pure calcium sulphate beads [Stimulan R]1 was used for local elution of antibiotics in 45 patients with lower limb bone or joint infections. Tailored plans were made by Orthopedic surgeon and Microbiologist MDTs based on bacteria and sensitivities. Cases included 20 THR, 13 TKR, 5 Hemiarthroplasties, 4 tibial nonunions, 1 infected femoral plate and 2 paediatric osteomyelitis. Organisms isolated – Coagulase negative Staphs, Staph aureus, MRSA, E coli, Enterococcus, Enterobacter cloacae, Serratia and 1 Salmonella typhimurium!!. In our cases, a combination of Vancomycin and Gentamicin was added to Stimulan beads following manufacturer's mixing guide. In 2 cases, we added Ceftazidime to the beads and Daptomycin in 1 case. In bone infections, surgical debridement and systemic antibiotics were also needed. All arthroplasty infections underwent explantation with addition of antibiotic impregnated beads either at single stage or both stages of 2 stage revisions and systemic antibiotics. Follow up (ranging 9months to 2 years) indicates no failure so far. The beads caused no excessive wound drainage. There was no need to remove beads as they dissolve. In the cases where a staged revision was performed, the beads were inserted at first stage and there was microbiological clearance of infection at 2nd stage. Our series includes some experince in paediatric cases too. As far as we are aware, this is the largest series in the UK from a single centre reporting experience with Stimulan in infected bone and joints of the lower limbs. Our experience suggests use of dissolvable pure Calcium sulphate beads impregnated with carefully selected antibiotics, works as an effective adjunct to current treatments and offers flexibility with choice of antiobiotics that can be added locally. Acknowledgements. Biocomposites UK for supporting attendance at EBJIS. Authors control ownership of all data and analysis


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 43 - 47
1 Nov 2014
Su EP Su SL

Surgical interventions consisting of internal fixation (IF) or total hip replacement (THR) are required to restore patient mobility after hip fractures. Conventionally, this decision was based solely upon the degree of fracture displacement. However, in the last ten years, there has been a move to incorporate patient characteristics into the decision making process. Research demonstrating that joint replacement renders superior functional results when compared with IF, in the treatment of displaced femoral neck fractures, has swayed the pendulum in favour of THR. However, a high risk of dislocation has always been the concern. Fortunately, there are newer technologies and alternative surgical approaches that can help reduce the risk of dislocation. The authors propose an algorithm for the treatment of femoral neck fractures: if minimally displaced, in the absence of hip joint arthritis, IF should be performed; if arthritis is present, or the fracture is displaced, then THR is preferred.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):43–7.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 165 - 165
1 Mar 2013
Devadasan B Loo W Johari J
Full Access

Most studies about hemi-arthroplasty of hip have focused on clinical aspects. Design features of various implants of hemi-arthroplasty have not been studied extensively. The aim was to investigate the relationships between radiological variables and possible mode of failure in various hemiarthroplasty implants in intracapsular neck of femur fractures.

A retrospective review of 42 hemi hip arthroplasties, Austin Moore and Thompson prosthesis by Biomet, Medical Product Service (Tipsan) and Smit Medimed (SMPL) used in our hospital. Controversy exists between indication for a particular design in an unselected series of patients once excluding the choice of cementing or uncementing the prosthesis. In monoblock prosthesis not only the head-neck region affects the stability but also the stem fit in proximal femur.

Surgeon preference to technique and approach excluded. Premorbidly all patients were mobilising independently. 5 criteria reviewed. 1) head size of prosthesis 2) neck length 3) prosthesis stem shaft angle 4) stem-cortical distance ratio and 5) shape of the femoral canal as classified by Dorr. Head size compared in AP views of involved hip and normal head size compared with that of prosthesis. A difference <2 mm or >3 mm indicative of incorrect size. Neck length measured by the vertical distance from center of head to superior aspect greater trochanter was zero. A range of +/− 5 mm was acceptable. Neck shaft angle with a difference of >5 degrees was indicative of varus position of the stem. Canals of the proximal femoral categorized as a) stove pipe b) champagne c) fluted varieties radiologically. X-ray magnification corrected. All measurements were done on immediate postoperative radiographs.

Stability of various design features of straight stemmed and curved implants are dependant on the anterior bowing angle and canal ratio of femur to prosthesis. A prospective study with CT from selected shapes of the proximal femoral is being carried out. Inappropriate head size as reported by Thompson or neck length was related to incidence of dislocation resulting in failure. Our findings emphasise importance of careful selection of a particular implant design towards the morphology of the femoral canal.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 15 - 15
1 Mar 2013
Noureddine H Roberts G
Full Access

Following the recommendation of NICE guidelines (CG124) we have recently started using cemented smooth tapered stem hemiarthroplasty as our standard management of intra-capsular neck of femur fractures. Prior to publication of the above guidelines the standard implant utilised was Thompson Hemiarthroplasty prosthesis. The cost implications of this change have not been fully appreciated and the benefit of these changes in ASA grade 3–4 patients has not previously been analysed.

We identified a cohort of 89 patients admitted with displaced intra-capsular neck of femur fracture with an ASA grade 3–4. These underwent hip hemiarthroplaties at our centre over a period of 12 months (before and after guideline implementation). Data regarding in-hospital mortality, dislocation, reoperation and place of discharge were retrospectively collected and analysed.

Our cohort included 46 patients who underwent a Thompsons Hemiarthroplasty, 30 patients who had a cemented smooth tapered stem hemiarthroplasty and 13 patients who had an Austin-moore Hemiarthroplasty.

In-patient mortality rates were highest in the Austin-moore group, followed by the Thompsons group compared to none in the smooth tapered stem group. However, this was not statistically significant. One patient in the Thompsons group and one patient in the smooth tapered group had multiple dislocations and re-operations, compared with none in the Austin-moore group. In terms of percentage of patients who were discharged home from hospital the smooth tapered stem group had a percentage that was more than twice that of the Thompson's which was in turn higher than that found in the Austin-moore group.

In conclusion, our data suggests that in patients with an ASA grade of 3–4 there is no significant benefit from using cemented smooth tapper stems when performing a Hip Hemiarthroplasty compared with a well performed Thompsons and that the cost savings of this is significant. We accept that our current numbers are relatively small and further work is needed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 118 - 118
1 Sep 2012
Leonardsson O Garellick G Kärrholm J Akesson K Rogmark C
Full Access

Background

In Sweden approximately 6000 patients yearly sustain displaced femoral neck fractures. During the last decade there has been a shift towards more arthroplasties at the expense of internal fixation. In 2008 approximately 75% of the dislocated femoral neck fractures in Sweden were treated with arthroplasties. Those patients are typically elderly and frail and the vast majority of them receive hemiarthroplasties. In 2005 a national hemiarthroplasty registration was established as part of the Swedish Hip Arthroplasty Register (SHAR).

Material & Method

The SHAR aims to register all hemiarthroplasties performed in Sweden, including primary and salvage procedures. Surgical and patient details are recorded and re-operations are registered.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 5 - 5
1 Jul 2012
McKenna S Kelly S
Full Access

Current evidence suggests that we should be moving away from Thompson's hemiarthroplasties for patients with intracapsular hip fractures. Furthermore, the use of cement when inserting these prostheses is controversial. We aim to show the Inverness experience.

We performed a retrospective review of all NHS Highland patients who underwent a hemiarthroplasty for an intracapsular neck of femur fracture over the last 15 years. Demographics and the use of cement were documented. Further analysis of this group was performed to identify any of these patients who required revision. Patients requiring revision had their case-notes reviewed to identify the cause for further surgery.

2221 patients from the Highland area had a hemiarthroplasty for an intracapsular neck of femur fracture since 1996. 1708 female (77%) and 513 male (23%). Ages ranged from 28 years to 104 years (mean 80). 2180 of this group had their operations in Raigmore with the remaining 41 at various centres throughout Scotland. 623 (28%)had a cemented hemiarthroplasty, with the remaining 1578 (72%) having an uncemented Thompson's hemiarthroplasty. The revision rate for the cemented group was 2% (13 of 623 patients). In the uncemented group it was 0.4% (6 of 1578). Reasons from revision included dislocation, periprosthetic fracture, infection and pain.

Current evidence from some joint registers regarding the use of Thompson's hemiarthroplasty in the elderly is discouraging. The use of bone cement in this group with multiple co-morbidities is not without it's risks. Our data suggests that uncemented Thompson's hemiarthroplasties in low demand elderly patients with multiple co-morbidities can yield excellent results with less risk to the patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 10 - 10
1 Apr 2012
Riley T Mounsey E Blake S
Full Access

It costs the NHS £2billion/year to treat 70000 hip fractures. Following hemiarthroplasty a departmental x-ray is standard practice.

During 2009 217 hemiarthroplasties were performed in our unit. 210 had postoperative radiographs (148 departmental, 62 in theatre). All patient demographics were considered and hospital costs accounted for.

Mean patient age was 83 (55-100) years. Mean theatre times were 120 (51-213) minutes in the departmental x-ray group and 128 (74-187) minutes in the theatre imaging group. Hospital stay was decreased from 12.8 (3-41) days in the departmental x-ray group to 11.8 (3-32) days in the theatre imaging group. Orthopaedic beds cost £136/day. Departmental x-rays give a radiation dose of ∼12mGy and costs £48.30, theatre imaging gives ∼0.26mGy with no additional cost given the radiographers previous allocation to the list.

Changing our practice to intra-theatre imaging has improved patient safety, reduced the average inpatient stay and saves our trust approximately £40,000 annually.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 206 - 206
1 May 2009
Wadawadigi S Banerjee B
Full Access

Purpose of the study: To ascertain, the Post-operative Joint Infection rates in the Department during 2004. Methods used and the results: Details of 607 patients were collected. Females were 379(62%) whereas males were 228(38%). Less than 65 years were 133(22%), between 66 and 80 years were 319(53%) and above 80s figure was 155(26%). Total of 197 Primary Hip Arthroplasties (THR) and 190 Knee Arthroplasties (TKR) had been performed. Hip Hemiarthroplasties totalled 137. All the demographic indicators were looked in detail for gender and age range distribution. Revision THRs were 66 whereas 17 were Revision TKRs. For the purpose of this study, the Revision Arthroplasties were excluded. Amongst Total Joint Arthroplasties, though 10 patients out of 387 had provided positive results for STAA (Staph. Aureus) from swab specimens, none of the patients developed deep infection. But out of 8, who showed MRSA growth from wound swabs, one patient developed deep infection and needed conversion to Girdlestone procedure. Thus the positive results for wound specimens were 18(4.65%), while the re-operation rate was 1(0.26%). Conclusion: It is interesting to note that MRSA was prevalent in above 80s while STAA was more common in under 80s. Majority of MRSA positive results were after 30 days while that for the STAA it was before 30 days post-operatively. Of the 18 ‘infected’ cases; Consultants and SAS surgeons had performed 9 cases each. Amongst 137 Hip Hemiarthroplasties, 25 showed positive growths, 7 for STAA and 18 for MRSA. None needed re-operation. Interesting revelations on misconceptions are revealed!


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 9 - 9
1 Mar 2008
Kendrew J Varley J Parker M
Full Access

One of the most common early complications after hemiarthroplasty is dislocation, with an incidence of 2 to 4%. After dislocation the mortality and morbidity are significantly increased to in excess of 50%.

It has been claimed that a bipolar hemiarthroplasty has a lower risk of dislocation than a unipolar implant. In addition it has been suggested that patients with either Parkinson’s disease or a previous stroke are at increased risk of dislocation. We investigated these claims by performing a comprehensive literature search of articles published in the last 40 years and data obtained from our own hip fracture database.

From the literature review, 133 reports involving 21,872 patients were retrieved. A further 1235 hip fractures treated by hemiarthroplasty were recorded from our database. 791 (3.4%) dislocations were recorded. Dislocation rate for unipolar prosthesis was higher than bipolar prosthesis (3.9% versus 2.5%). Dislocation rate for posterior surgical approach was higher than for anterior approach (5.1% versus 2.4%). Dislocation rate for cemented prosthesis was 3.6% versus 2.3% in un-cemented prosthesis. However, the effect of the type of implant becomes non-significant on adjusting for the use of cement and surgical approach. The incidence of open reduction after dislocation was increased with bipolar implants. Patients with Parkinson’s disease showed a highly statistically significant increase in dislocation rate (8.7% to 3.4%). The dislocation rate with respect to ipsilateral hemiplegia was 1.6%.

This study indicates there is no difference in the dislocation rate between a unipolar and bipolar prosthesis but if a bipolar prosthesis dislocates, there is an increased risk of failure to reduce the prosthesis by closed means. Patients with Parkinson’s disease are at an increased risk of dislocation but this is not the case for those with a hemiplegia. To minimise the risk of dislocation of a hemiarthroplasty, particularly in those patients with Parkinson’s disease, a unipolar hemiarthroplasty inserted via an antero-lateral approach is recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 288 - 291
1 Mar 2008
Labek G Stoica CI Böhler N

This article considers some of the problems of the interpretation of information from other national arthroplasty registers when setting up a new register. In order for the most useful information to be available from registers much international co-operation is required between all those responsible for the design of registers as well as those who gather, assess and publish the data.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 324 - 324
1 Sep 2005
Ryan P Ingerson L Griffith E Graves S Davidson D McDermott B Pratt N
Full Access

Introduction and Aims: Nine countries have established national joint replacement registries. The first population-based national registry, the Swedish Knee Registry, was established in 1975 with the most recent, the UK National Joint Registry (UK NJR), beginning in 2003. We identify commonalities and differences in the structure, function and methods of reporting among these national registries. Method: Data was collected from the annual reports of the various registries, published literature and personal contact with registry coordinators and directors. Results: Commonalities include registry ownership, source of funding, procedure types collected, method of data collection and validation of data. Most registries are owned by the national Orthopaedic Association or a government agency. The most common source of funding is government; membership fees and a mandated implant levy are also used. Most national registries collect total hip and knee replacements, primaries and revisions. Hemiarthroplasties are not commonly collected, though some registries collect additional joints (including shoulder, elbow, wrist, finger, ankle and toe). The most common method of data collection is paper-based, usually from theatre, with subsequent data entry at the registry. Electronic data collection is used to supplement the paper-based system in some countries, while the Swedish Hip Registry and the UK NJR utilise a web application for the submission of data. Most registries attempt to validate their data against hospital inpatient data held by government. Differences include reporting of rates, cost per registration and definitions. Failures of primary implants may be reported as cumulative proportions, true incidence rates or survival probabilities. This leads to difficulties in comparison of data among the national registries. The cost of registering a procedure varies up to five-fold across countries. Conclusion: There are obvious opportunities for collaboration between national joint replacement registries, however some issues need to be addressed. These include definitions of what is collected, for example hemiarthroplasties, and methods of analysis and reporting, especially revision rates


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 49 - 49
1 Mar 2005
Foster A Thompson N Canavan B Wong J Charlwood A
Full Access

The Austin Moore Prosthesis (AMP) is a recognised treatment option in the management of displaced intracapsular femoral neck fractures in elderly patients. Peri-prosthetic femoral fractures are a potential complication of both cementless and cemented hemiarthroplasty and can occur intra-operatively or at any stage following implant insertion.

Over a two-year period, 244 patients underwent hemiarthroplasty for a displaced intracapsular femoral neck fracture. Seventy patients had an AMP inserted whilst 174 patients were treated using a cemented Thompson stem. All of the AMP’s were inserted by, or under the supervision of an orthopaedic consultant.

Five patients (7%) from the AMP group sustained a periprosthetic femoral fracture. Four required revision surgery. The remaining case was managed non-operatively.

When compared to the cemented Thompson hemiarthroplasties performed over the same time period, despite the operating time being significantly less, the number of periprosthetic femoral fractures was significantly greater with the AMP. Furthermore, the early mortality rate was significantly higher for the AMP group who, were also significantly older and more likely to require postoperative blood transfusion. There was no significant difference in gender or ASA grade between the two groups.

These findings suggest that for displaced intracapsular femoral neck fractures in elderly patients, when hemiarthroplasty is the treatment of choice, a cemented prosthesis is preferable.