Advertisement for orthosearch.org.uk
Results 1 - 20 of 40
Results per page:
Bone & Joint 360
Vol. 12, Issue 5 | Pages 21 - 23
1 Oct 2023

The October 2023 Sports Roundup. 360. looks at: Extensor mechanism disruption in the treatment of dislocated and multiligament knee injuries; Treatment of knee osteoarthritis with injection of stem cells; Corticosteroid injection plus exercise or exercise alone as adjuvants for patients with plantar fasciitis?; Generalized joint hypermobility and a second ACL injury?; The VISA-A ((sedentary) questionnaire for Achilles tendinopathy?


Bone & Joint 360
Vol. 12, Issue 3 | Pages 16 - 18
1 Jun 2023

The June 2023 Knee Roundup360 looks at: Cementless total knee arthroplasty is associated with early aseptic loosening in a large national database; Is cementless total knee arthroplasty safe in females aged over 75 years?; Could novel radiological findings help identify aseptic tibial loosening?; The Attune cementless versus LCS arthroplasty at introduction; Return to work following total knee arthroplasty and unicompartmental knee arthroplasty; Complications and downsides of the robotic total knee arthroplasty; Mid-flexion instability in kinematic alignment better with posterior-stabilized and medial-stabilized implants?; Patellar resurfacing does not improve outcomes in modern knees.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 173 - 181
1 Mar 2022
Sobol KR Fram BR Strony JT Brown SA

Aims

Endoprosthetic reconstruction with a distal femoral arthroplasty (DFA) can be used to treat distal femoral bone loss from oncological and non-oncological causes. This study reports the short-term implant survivorship, complications, and risk factors for patients who underwent DFA for non-neoplastic indications.

Methods

We performed a retrospective review of 75 patients from a single institution who underwent DFA for non-neoplastic indications, including aseptic loosening or mechanical failure of a previous prosthesis (n = 25), periprosthetic joint infection (PJI) (n = 23), and native or periprosthetic distal femur fracture or nonunion (n = 27). Patients with less than 24 months’ follow-up were excluded. We collected patient demographic data, complications, and reoperations. Reoperation for implant failure was used to calculate implant survivorship.


Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims

Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release.

Methods

A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims

Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components.

Methods

This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 191 - 195
1 Jun 2021
Gausden EB Shirley MB Abdel MP Sierra RJ

Aims. To describe the risk of periprosthetic joint infection (PJI) and reoperation in patients who have an acute, traumatic wound dehiscence following total knee arthroplasty (TKA). Methods. From January 2002 to December 2018, 16,134 primary TKAs were performed at a single institution. A total of 26 patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68 years (44 to 87), 38% (n = 10) were female, and mean BMI was 34 kg/m. 2. (23 to 48). Median time to dehiscence was 13 days (interquartile range (IQR) 4 to 15). The dehiscence resulted from a fall in 22 patients and sudden flexion after staple removal in four. The arthrotomy was also disrupted in 58% (n = 15), including a complete extensor mechanism disruption in four knees. An irrigation and debridement with component retention (IDCR) was performed within 48 hours in 19 of 26 knees and two-thirds were discharged on antibiotic therapy. The mean follow-up was six years (2 to 15). The association of wound dehiscence and the risk of developing a PJI was analyzed. Results. Patients who sustained a traumatic wound dehiscence had a 6.5-fold increase in the risk of PJI (95% confidence interval (CI) 1.6 to 26.2; p = 0.008). With the small number of PJIs, no variables were found to be significant risk factors. However, there were no PJIs in any of the patients who were treated with IDCR and a course of antibiotics. Three knees required reoperation including one two-stage exchange for PJI, one repeat IDCR for PJI, and one revision for aseptic loosening of the tibial component. Conclusion. Despite having a traumatic wound dehiscence, the risk of PJI was low, but much higher than experienced in all other TKAs during the same period. We recommend urgent IDCR and a course of postoperative antibiotics to decrease the risk of PJI. A traumatic wound dehiscence increases risk of PJI by 6.5-fold. Cite this article: Bone Joint J 2021;103-B(6 Supple A):191–195


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 145 - 149
1 Jun 2021
Crawford DA Passias BJ Adams JB Berend KR Lombardi AV

Aims

A limited number of investigations with conflicting results have described perivascular lymphocytic infiltration (PVLI) in the setting of total knee arthroplasty (TKA). The purpose of this study was to determine if PVLI found in TKAs at the time of aseptic revision surgery was associated with worse clinical outcomes and survivorship.

Methods

A retrospective review was conducted on 617 patients who underwent aseptic TKA revision who had histological analysis for PVLI at the time of surgery. Clinical and radiological data were obtained pre- and postoperatively, six weeks postoperatively, and then every year thereafter.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1682 - 1688
1 Dec 2020
Corona PS Vicente M Carrera L Rodríguez-Pardo D Corró S

Aims

The success rates of two-stage revision arthroplasty for infection have evolved since their early description. The implementation of internationally accepted outcome criteria led to the readjustment of such rates. However, patients who do not undergo reimplantation are usually set aside from these calculations. The aim of this study was to investigate the outcomes of two-stage revision arthroplasty when considering those who do not undergo reimplantation, and to investigate the characteristics of this subgroup.

Methods

A retrospective cohort study was conducted. Patients with chronic hip or knee periprosthetic joint infection (PJI) treated with two-stage revision between January 2010 and October 2018, with a minimum follow-up of one year, were included. Variables including demography, morbidity, microbiology, and outcome were collected. The primary endpoint was the eradication of infection. Patients who did not undergo reimplantation were analyzed in order to characterize this subgroup better.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 12 - 12
1 Oct 2020
Wooster BM Abdel MP Berry DJ Pagnano MW
Full Access

Introduction. Arthrofibrosis remains a persistent complication following total knee arthroplasty (TKA). Although manipulation under anesthesia (MUA) is an effective early treatment, the risks and value of this procedure beyond 3 months after TKA remain controversial. The purpose of this study was to examine the safety and efficacy of late MUAs for arthrofibrosis. Methods. From our institutional total joint registry, 82 TKAs (77 patients) who underwent MUA >3 months after primary (83%) or revision (17%) TKA were identified. Mean time to MUA was 7 months: 66% performed between 4–6 months, 18% between 7–12 months, 16% beyond 12 months. MUAs were coupled with arthroscopic assistance in 26% (12% limited lysis of adhesions, 13% formal arthroscopic debridement). Mean age was 61 years, 59% females, and mean BMI was 33kg/m. 2. Mean follow-up was 5 years. Results. No fractures, extensor mechanism disruptions, or other complications related to late MUA occurred. The mean ROM gained after MUA was 18° (76° to 94°, p<0.001). Substantial ROM gains (≥20°) occurred in 50%, while 21% made no gains or lost ROM after MUA. ROM gains ≥20° occurred in 54% of primary TKAs and 28% of revision TKAs. While ROM gains were higher when performed between 3–6 months (21°) compared to 6–12 months (13°) and >12 months (11°), these differences did not reach statistical significance (p=0.26). No differences in mean ROM gains were observed in MUAs performed with or without arthroscopic assistance (19° versus 15°, p=0.54). Kaplan Meier survivorship free of repeat MUA and revision TKA were 85% and 80% at 20 years, respectively. Conclusion. Late MUA, coupled with arthroscopic assistance in selected patients, was safe in a broad range of stiff primary and revision TKAs with no fractures or extensor disruptions occurring. While mean ROM improvements were modest, a substantial subset of patients achieved clinically important ROM gains ≥20°. Summary. Late MUA substantially improved ROM in a subset of patients with stiff TKAs and was done safely. In selected patients, arthroscopic lysis of adhesions or formal debridement aided the perceived safety and efficacy


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 9 - 9
1 Oct 2020
Gausden EB Shirley M Abdel MP Sierra RJ
Full Access

Background. There are limited data on the complication rates and risk of periprosthetic joint infection (PJI) in patients who have an acute wound dehiscence after total knee arthroplasty (TKA). Methods. From 2002 to 2018, 16,134 primary TKAs were performed at a single institution. Twenty-six patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68, 38% were female, and mean BMI was 33 kg/m2. Median time to dehiscence was 13 days. The dehiscence resulted from a fall in 22 cases, including 4 in-hospital falls (3 with femoral nerve blocks), and sudden flexion after staple removal in 4 cases. The arthrotomy was disrupted in 58%, including a complete extensor mechanism disruption in 4 knees. A surgical debridement was performed within 48 hours in 19 of 26 knees. Two-thirds were discharged on antibiotic therapy. Results. Only two knees were complicated by PJI (cumulative incidence of 11% vs. 1% in all other primary TKAs, HR 6.5, p <0.01). One patient who developed a PJI was initially treated with a bedside closure in the ER rather than surgical debridement. The second patient had a complete extensor mechanism disruption at the time of dehiscence and was treated with surgical debridement, but did not receive a subsequent course of antibiotics. There were no PJIs in any of the cases that were treated with surgical debridement and a course of antibiotics. Three knees required reoperation (cumulative incidence of reoperation was 16% at 2 years, compared to 6% in all other primary TKAs, p=0.32) including 1 two-stage exchange for PJI, 1 irrigation and debridement with component retention for PJI, and 1 revision for tibial component aseptic loosening. Conclusion. Despite having a traumatic wound dehiscence, with nearly 60% resulting in arthrotomies that exposed implants, the risk of PJI was low but significantly higher than not having a traumatic arthrotomy. We recommend urgent surgical irrigation and debridement, inspection of arthrotomy integrity, and antibiotic treatment to decrease the risk of PJI. Summary. An acute, traumatic wound dehiscence with in the first 30 days after primary TKA results in a 11% risk of infection at 2 years


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 13 - 13
1 Oct 2020
Chalmers BP Mishu M Goytizolo E Jules-Elysee K Westrich GH
Full Access

Introduction. Manipulation under anesthesia (MUA) remains the gold standard to address restricted range of motion (ROM) within 3–6 months after primary total knee arthroplasty (TKA). However, there is little data on the outcomes of MUA with different types of anesthesia. We sought to compare the outcomes of patients undergoing MUA with intravenous (IV) sedation and neuraxial anesthesia. Methods. We identified 548 MUAs after primary TKA (136 IV sedation, 413 neuraxial anesthesia) at a single institution from 2016–2019. Mean age was 62 years and 349 patients (64%) were female. Mean body mass index was 32 kg/m. 2. The mean time from primary TKA to MUA was 10 weeks. Mean pre-MUA ROM was similar between each group; mean pre-MUA extension was 4.2° (p=0.35) and mean pre-MUA flexion was 77° (p=0.56). Patient demographics were statistically similar between both groups. We compared immediate complications, including fracture, extensor mechanism disruptions, and wound complications, Visual analogue pain scores (VAS), length of stay (LOS), and immediate and 3 month follow-up ROM between these groups. Results. No patients in either group sustained an immediate post-MUA complication. Patients undergoing MUA with IV sedation had significantly higher day of MUA average VAS of 5.1 compared to 4.1 in the neuraxial group (p<0.001). The average LOS was shorter in patients that received IV sedation (9 hours) compared to neuraxial anesthesia (12 hours) (p=0.009). Immediate-post MUA ROM was 1° – 121° in the IV sedation group and 0.9° – 123° in the neuraxial anesthesia group (p=0.21). Three month follow-up ROM was 2° – 108° in the IV sedation group and 1.9° – 110° in the neuraxial anesthesia group. Conclusion. IV sedation and neuraxial anesthesia are both effective anesthetic methods for patients undergoing MUA after primary TKA with minimal perioperative differences. Surgeons and anesthesiologists should cater anesthetic technique to patient specific needs as the orthopedic outcomes are similar for both methods; however, IV sedation resulted in a shorter LOS


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims

The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA.

Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 123 - 128
1 Jun 2020
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring T

Aims

Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options.

Methods

Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims

To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps.

Methods

In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 9 - 9
1 Feb 2020
Stulberg B Zadzilka J Kreuzer S Long W Kissin Y Liebelt R Campanelli V Zuhars J
Full Access

Introduction. Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Methods. Patients had to be ≥ 21 years old with BMI ≤ 40, Kellgren-Lawrence Grade ≥ 3, coronal deformity ≤ 20°, and sagital flexion contracture ≤ 15° to participate. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs (medial collateral ligament injury, extensor mechanism disruption, neural deficit, periprosthetic fracture, patellofemoral dislocation, tibiofemoral dislocation, vascular injury) were specifically identified to evaluate safety. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. Results were compared to published values associated with manual TKA. Results. A total of 115 patients were enrolled at 6 US centers and followed for a maximum of 12 months after surgery. Mean surgical time (incision to close) improved consistently as the technique evolved (first 10 cases = 131.5 min, first 20 cases = 122.4 min), with mean robot time = 45.8 min. The incidence of pre-defined AEs identified was 0%, serving as a measure of safety of the procedure. Outside of the pre-defined list, only one AE was definitely associated with the use of the device; a metal tack was left inside the knee joint but no reoperation was performed. No patients required a blood transfusion. Alignment outside of the ± 3° goal was 11.2% with a difference of 0.5° ± 1.9° (mean ± STD), which represents a 43% statistically significant (posterior probability > 0.95) reduction in malalignment compared to the literature. Mean KSS Functional scores improved from 40.2 at baseline to 65.4 at 3 months, mean KSS Objective scores improved from 46.9 to 71.2, mean KSS Patient Satisfaction scores improved from 14.5 to 30.6, and mean SF-12 Physical Component scores improved from 32.9 to 43.5. Discussion. The TSolution One Total Knee Application is descended from an active robotic system used in >8000 cases outside the United States since 2002. This trial represents the first US based study of this technology for primary TKA. The clinical study demonstrated positive safety outcomes as none of the seven pre-defined AEs were observed and there were no cases requiring transfusion. A positive effectiveness outcome was also demonstrated as the malalignment rate found in this study showed a substantial reduction from the 32% malalignment rate published in the literature for conventional instruments. KSS and SF-12 scores were comparable to other published TKA series. For any figures or tables, please contact authors directly


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1356 - 1361
1 Nov 2019
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims

Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results.

Patients and Methods

In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2 (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 10 - 10
1 Oct 2019
Stulberg BN Zadzilka JD Kreuzer S Long WJ Kissin YD Liebelt RA Campanelli V Zuhars J
Full Access

Introduction. Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate the safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Methods. Inclusion criteria for patients receiving robotic TKA were: primary unilateral TKA; Kellgren-Lawrence OA grade 3 or 4; BMI < 40 kg/m2; coronal plane deformity < 20° varus; sagittal flexion contracture < 15°. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs were specifically identified to evaluate safety (Healy et al, 2013): medial collateral ligament injury; extensor mechanism disruption; neural deficit; periprosthetic fracture; patellofemoral dislocation; tibiofemoral dislocation; and vascular injury. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. For each outcome, results were compared to published values associated with manual TKA. Results. A total of 115 patients were enrolled at 6 US centers and followed for a maximum of 12 months after surgery. Mean surgical time (incision to close) improved consistently as the technique evolved (first 10 cases = 131.5 min, first 20 cases = 122.4 min), with mean robot time = 45.8 min. The incidence of pre-defined AEs identified was 0%, serving as a measure of safety of the procedure. Outside of the pre-defined list, only one AE was definitely associated with the use of the device; a metal pin was left inside the knee joint but no reoperation was performed. No patients required a blood transfusion. Alignment outside of the ± 3° goal was 11.2% with a difference of 0.5° ± 1.9° (mean ± STD), which represents a 45% statistically significant (posterior probability > 0.95) reduction in malalignment compared to the literature (Mason et al, 2007). Mean KSS Functional scores improved from 40.5 at baseline to 65.3 at 3 months, mean KSS Objective scores improved from 36.8 to 81.0, mean KSS Patient Satisfaction scores improved from 14.4 to 30.6, and mean SF-12 Physical Component scores improved from 32.9 to 43.5. Discussion. The TSolution One Total Knee Application is descended from an active robotic system used in >8000 cases outside the United States since 2002. This trial represents the first US based study of this technology for primary TKA. The clinical study demonstrated positive safety outcomes as none of the seven pre-defined AEs were observed and there were no cases requiring transfusion. A positive effectiveness outcome was also demonstrated as the malalignment rate found in this study showed a substantial reduction from the 32% malalignment rate published in the literature for conventional instruments. KSS and SF-12 scores were comparable to other published TKA series. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 27 - 27
1 Oct 2019
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring TK
Full Access

Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated aseptic tibial loosening were identified from 2012–2017. Patients with revision implants, or those revised for infection, instability, osteolysis, or femoral component loosening were excluded. 161 patients met these criteria, 85 patients had an isolated tibial revision and 76 had revision of both components despite having only a loose tibial component. Patient demographics as well as clinical and radiographic outcomes were recorded for each cohort. Results. Patient demographical information, including age, gender, and BMI were statistically similar between the two cohorts. Median follow-up was 3.5 years. Supplemental metaphyseal fixation was used in 22 patients in the isolated tibial cohort and 19 of the full revision cohort. There was a higher incidence of radiographic loosening in the full component revision cohort (10.5% vs. 6.0%; p=0.28). There were five failures requiring revision in the isolated tibial cohort, two for sepsis, one for repeat isolated tibial loosening, one for femoral aseptic loosening, and one for an extensor mechanism disruption. There were eight failures in the full component cohort, three for patellar avascular necrosis, two for sepsis, one for repeat tibial loosening, one for arthrofibrosis, and one for a postoperative wound dehiscence. Conclusion. Isolated tibial revision for aseptic tibial loosening has similar clinical and radiographic results when compared to full component revision. Although no intraoperative complications were identified when revising the femur, there is the potential for complications unique to femoral revision. Femoral component revision for isolated tibial loosening is unnecessary and should be avoided provided adequate ligamentous stability can be obtained. Keywords: Aseptic loosening, Tibial loosening, revision total knee replacement, total knee replacement. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 91 - 97
1 Jul 2019
Chalmers BP Weston JT Osmon DR Hanssen AD Berry DJ Abdel MP

Aims

There is little information regarding the risk of a patient developing prosthetic joint infection (PJI) after primary total knee arthroplasty (TKA) when the patient has previously experienced PJI of a TKA or total hip arthroplasty (THA) in another joint. The goal of this study was to compare the risk of PJI of primary TKA in this patient population against matched controls.

Patients and Methods

We retrospectively reviewed 95 patients (102 primary TKAs) treated between 2000 and 2014 with a history of PJI in another TKA or THA. A total of 50 patients (53%) were female. Mean age was 69 years (45 to 88) with a mean body mass index (BMI) of 36 kg/m2 (22 to 59). In total, 27% of patients were on chronic antibiotic suppression. Mean follow-up was six years (2 to 16). We 1:3 matched these (for age, sex, BMI, and surgical year) to 306 primary TKAs performed in 306 patients with a THA or TKA of another joint without a subsequent PJI. Competing risk with death was used for statistical analysis. Multivariate analysis was followed to evaluate risk factors for PJI in the study cohort.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 47 - 47
1 May 2019
Sierra R
Full Access

Chronic extensor mechanism insufficiency around TKA is a very challenging pathology to treat. An insufficient extensor mechanism negatively affects implant survival and patient outcomes. There are several risk factors for extensor mechanism disruption and the surgeon should be aware and avoid these problems in the perioperative period. In appropriately selected patients, reconstruction of the extensor mechanism is a valid option. Whole extensor mechanism and Achilles tendon allograft reconstruction of the deficient extensor mechanism have been proposed with good early published results. These reconstructions, however, are expensive and with time may stretch and lead to recurrence of an extensor lag. An alternative to allograft, is the use of Marlex mesh as popularised by Browne and Hanssen. This technique uses a knitted monofilament polypropylene mesh that is secured to the patient's native lateral tissue and covered by an appropriately dissected and distalised vastus medialis muscle. The technique can be used for both patellar and quadriceps tendon deficiencies and can be done with or without implant revision and is currently the treatment of choice at the presenter's institution. The surgeon should be aware of the complexity and limitations of these three reconstructive techniques