The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims

The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes.

Methods

We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 34 - 37
1 Oct 2024

The October 2024 Shoulder & Elbow Roundup360 looks at: Proximal humeral fractures with vascular compromise; Outcomes and challenges of revision arthroscopic rotator cuff repair: a systematic review; Evaluating treatment effectiveness for lateral elbow tendinopathy: a systematic review and network meta-analysis; Tendon transfer techniques for irreparable subscapularis tears: a comparative review; Impact of subscapularis repair in reverse shoulder arthroplasty; Isolated subscapularis tears strongly linked to shoulder pseudoparesis; Nexel and Coonrad-Morrey total elbow arthroplasties show comparable revision rates in New Zealand study; 3D MRI matches 3D CT in assessing bone loss and shoulder morphology in dislocation cases


Bone & Joint Research
Vol. 13, Issue 5 | Pages 201 - 213
1 May 2024
Hamoodi Z Gehringer CK Bull LM Hughes T Kearsley-Fleet L Sergeant JC Watts AC

Aims

The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA).

Methods

Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup. 360. looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 57 - 59
1 Apr 2021
Evans JT Whitehouse MR Evans JP


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims

The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome.

Methods

We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 27 - 30
1 Apr 2020


Bone & Joint 360
Vol. 6, Issue 6 | Pages 2 - 10
1 Dec 2017
Luokkala T Watts AC


Bone & Joint 360
Vol. 6, Issue 6 | Pages 25 - 28
1 Dec 2017


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 146 - 146
1 Mar 2017
Kia DS Willing R
Full Access

As a treatment for end-stage elbow joint arthritis, total elbow replacement (TER) results in joint motions similar to the intact joint; however, bearing wear, excessive deformations and/or early fracture may necessitate early revision of failed implant components. Compared to hips, knees and shoulders, very little research has been focused on the evaluation of the outcomes of TER, possible failure mechanisms and the development of optimal designs. The current study aims to develop computational models of TER implants in order to analyze implant behaviour; considering contact stresses, plastic deformations and damage progression. A geometrical model of a TER assembly was developed based on measurements from a Coonrad-Morrey TER implant (Zimmer, Inc., Warsaw, IN). Ultra high molecular weight polyethylene (UHMWPE) nonlinear elasto-plastic material properties were assigned to the humeral and ulnar bushings. A frictional penalty contact formulation with a coefficient of friction of 0.04 was defined between all of the surfaces of the model to take into account every possible interaction between different implant components in vivo. The loading scenario applied to the model includes a flexion-extension motion, a joint force reaction with variable magnitude and direction and a time varying varus-valgus (VV) moment with a maximum magnitude of 13 N.m, simulating a chair-rise scenario as an extreme loading condition. An explicit dynamic finite element solver was used (ABAQUS Explicit, Dassault Systèmes, Vélizy-Villacoublay, France), due to improved capabilities when performing large deformation analyses. Model results were compared directly with corresponding experimental data. Experimental wear tests were performed on the abovementioned implants using a VIVO (AMTI, Watertown, MA) six degree-of-freedom (6-DOF) joint motion simulator apparatus. The worn TER bushings were scanned after the test using micro computed tomography (µCT) imaging techniques, and reconstructed as 3D models. Comparisons were made based on the sites of damage and deformed geometries between the numerical results and experimental test data. In addition to that, parametric geometrical models were developed using worn geometry of the retrievals in order to account for primary wear and deformations while simulating long-term contact stress and secondary damage progression on the bushings (Fig. 1). Contact pressure distributions on the humeral and ulnar bushings correlate with the sites of damage as represented by the µCT data and gross observation of clinical retrievals. Furthermore, deformation patterns and kinematics of the components are in good agreement with the experimental results (Fig.2). Excessive plastic deformations are evident in both the numerical and the experimental results close to the regions with high contact pressures. Simulating parametric initially-worn geometries results in the formation of secondary damage zones, as well as redistribution of contact stresses and contact locations (Fig. 3). The results demonstrate UHMWPE bushing damage due to different loading protocols. Numerical results demonstrate strong agreement with experimental data based on the location of deformation and creep on bushings and exhibit promising capabilities for predicting the damage and failure mechanisms of TER implants. For figures/tables, please contact authors directly.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 976 - 983
1 Jul 2016
Streubel PN Simone JP Morrey BF Sanchez-Sotelo J Morrey ME

Aims

We describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation.

Patients and Methods

Between 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims. We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up. Patients and Methods. TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study. . Results. The mean follow-up of the 19 patients was 156 months (120 to 210). Two patients in the study group had undergone revision. One further patient had undergone a two-stage revision for infection but died before ten-year follow-up. Six other patients in the study group had evidence of loosening or wear of their bushings. Two were clinically symptomatic and were offered revision surgery. Male patients showed higher incidence of loosening and wear. Survivorship, with revision and definite loosening as end-points, was 89.5% at ten years in those patients followed for a minimum of ten years and 86% in the whole group of 36 patients. Conclusion. This study shows that only 53% of non-rheumatoid patients who undergo TEA for a fracture of the distal humerus survive to the tenth anniversary of their index procedure. For those that survive, TEA provides acceptable outcomes in terms of function and implant survival. Take home message: The surgeons undertaking these procedures should be aware of the long-term revision rates and also the gender difference in the rates of loosening. Cite this article: Bone Joint J 2016;98-B:381–6


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 65 - 65
1 Jan 2016
Ito H Ogino H Furu M Ishikawa M Matsuda S
Full Access

Background. Total elbow arthroplasty (TEA) has become an established procedure in the treatment of patients with rheumatoid arthritis (RA). However, there is little information on whether limited extension of the elbow affects clinical outcome scores after TEA and what causes the limited extension. Methods. We retrospectively analyzed fifty-four cases of primary TEA in patients with RA. There were seven men and thirty-nine women with a mean age of 63.6 years (range, thirty to eighty years). Thirty-seven of Coonrad-Morrey and seventeen of Discovery prostheses were used. The mean length of follow-up was 7.1 ± 4.0 years (range 2.0–14.6 years). Mayo Elbow Performing Score (MEPS) and radiological measurements were recorded. Anteroposterior and lateral radiographs were assessed before and after the operation and at the latest follow-up. Widening of the joint space was calculated by subtracting the length measured on the postoperative radiograph from that on the preoperative radiograph. Results. MEPS was significantly improved after surgery (51.2 to 91.1), especially in the domains of pain (18.6 to 43.1), stability (5.9 to 10) and daily function (10.7 to 21.0). Range of motion was significantly improved, in flexion (111.3° to 140.6°), pronation (62.1° to 72.3°), and supination (60.2° to 72.3°), but not in extension (30.0° to 28.8°). Simple and multivariate analyses showed that longer disease duration (p = 0.004), higher Larsen grade (p = 0.013), worse pronation/supination arc (p = 0.004) and worse postoperative extension (p = 0.033), but not postoperative flexion (p = 0.532), were significantly correlated with lower MEPS daily function. Conversely, simple and multivariate analyses showed that worse postoperative extension was correlated with lower MEPS daily function (p = 0.005) and worse preoperative extension (p < 0.001). Radiological analyses showed that, in the limited extension group (≧40°), the degree of extension was correlated with radiological widening of the joint. Conclusions. In linked TEA, perioperative widening of the elbow joint caused limited extension and worse daily function in patients with RA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 144 - 144
1 Jan 2016
Yonemoto Y Okamura K Takeuchi K Hosokawa T Kaneko T Matsushita M Okura C Kobayashi T Takagishi K
Full Access

Background. Previously, the Coonrad-Morrey elbow system has typically been performed using linked-type total elbow arthroplasty (TEA) implants. However, this implant have been reported to be associated with some problems, such as wearing down, loosening, the complexity of the necessary surgical techniques and inappropriate implant size for Asian people. The Discovery elbow system (Biomet Inc., Warsaw, US) has recently been developed and it has many advantages when compared to Coonrad-Morrey implant, but the treatment outcome for this system is unclear in patients with rheumatoid arthritis (RA). Objectives. The aim of this study was to clarify the outcome of TEA using the Discovery elbow system. Methods. Eleven RA patients (13 elbows) who underwent TEA using the Discovery elbow system were investigated in this study. Two patients (3 elbows) were males, and 9 patients (10 elbows) were females. Ten were right elbows, and 3 were left elbows. Two elbows has Larsen grade “disease, 7 had grade” disease and 4 elbows underwent revision surgery. The surgical approach used for all cases was Campbell's posterior approach. The Discovery elbow system was installed using cemented fixation. Two weeks after the operation, ROM exercise was started. The elbow ROM, Mayo elbow performance score (MEPS), and any complications observed at baseline, 6 months and 24 months after surgery were assessed. Results. The preoperative elbow ROM (mean±SD) was −33.4±4.4° in extension, 133.5±3.4° in flexion, 48.5±8.4° pronation and 67.7±5.7° in supination. The postoperative elbow ROM (mean±SD) was −18.5±6.2° in extension, 112.7±6.1° in flexion, 70.0±3.4° in pronation and 73.7±1.6° in supination. As a result, a significant improvement was observed in extension, flexion and pronation. The MEPS improved significantly at 6 months and 24 months after surgery. In addition, no implant loosening was found or revision surgery was required at 24 months after surgery. Conclusions. In this study, the elbow function was observed to significantly improve by TEA using the Discovery elbow system based on the short-time outcome. However, further study is still needed to clarify the long-term outcome of this implant in RA patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 147 - 147
1 Jan 2016
Sato A Nakamura H Takahashi K Takenouchi K Kawaji H Takai S
Full Access

Purpose. Clinical outocome of revision total elbow arthroplasty(TEA) in rheumatoid arthritis(RA) patients were evaluated. Methods. Clinical outocome of revision TEA that underwent between 2005 and 2013 were evaluated. Causes of revision, implanted revised prosthesis, a clinical score (the Japanese Orthopaedic Association (JOA) elbow assessment score), the arc of motion and complications were investigated. Totally, 6 patients underwent revision TEA. The patients were females with a mean age of 60.4 years (range, 32 to 72). Results. Seventy-two primary TEAs were done in corresponding period. Six out of 72 (8.3%) TEAs were revised. Causes of revision were loosening, instability (dislocation) and breakage of a component in 3, 2 and 1 cases, respectively. A mean duration from initial TEA to revision surgery was 10.3 years (range, 1 to 13). Semi-constrained arthroplasties (5 Coonrad-Morrey, 1 Discovery) were used for revision surgery. A mean JOA elbow assessment score improved from 59 to 81 point at the time of follow up. The mean ROM, flexion was improved 125 degrees, to 131 degrees. Extension, supination and pronation was not changed. A fracture at the time of implant withdrawal occurred as an intraoperative complication. The fractures were recovered by wiring with autologous bone graft from the ilium and a good bone union was achieved in 2 out of 3 cases. However, a re-revision surgery with plate was required in the remaining case. Conclusions. Revision TEA provided a satisfactory functional outcome. An intraoperative fracture was a critical complication in this procedure


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 592 - 592
1 Dec 2013
Wright T Gunsallus K Lipman J Hotchkiss R Figgie MP
Full Access

Implant designs for hip and knee arthroplasty have undergone a continual improvement process, but development of implants for total elbow arthroplasty (TEA) have lagged behind despite the marked mechanical burden placed on these implants. TEA is not as durable with failure rates approaching thirty percent at five years. The Coonrad-Morrey (Zimmer, Warsaw, IN), a linked design, remains the standard-bearer, employing polyethylene bushings through which a metal axle passes. A common failure mode is bushing wear and deformation, causing decreased joint function as the bushing-axle constraint decreases and osteolysis secondary to release of large volumes of wear debris. Improving upon this poor performance requires determining which factors most influence failure, so that failure can be avoided through design improvements. The approach integrates clinical observations of failed TEAs with implant retrieval analysis, followed by measurements of loads across the elbow for use in stress analyses to assess the performance of previous designs, and, finally, new design approaches to improve performance. Examination of the clinical failures of more than seventy Coonrad-Morrey TEAs revealed patterns of decreased constraint and stem loosening. Implant retrieval analysis from more than thirty of these cases showed excessive bushing deformation and wear and burnishing of the fixation stems consistent with varus moments across the joint. To determine loads across the elbow, motion analysis data were collected from eight TEA patients performing various activities of daily living. The kinematic data were input into a computational model to calculate contact forces on the total elbow replacement. The motion that produced the maximum contact force was a feeding motion with the humerus in 90° of abduction. For this motion, the joint reaction forces and moments at the point of maximum contact were determined from a computational model. We applied these loads to numerical models of the articulating bushings and axle of the Coonrad-Morrey to examine polyethylene strains as measures of damage and wear. Strain patterns in response to the large varus moment applied to the elbow during feeding activities showed extensive plastic deformation in the locations at which deformation and wear damage were observed in our retrieved implants (Fig. 1). Finally, we examined a new semi-constrained design concept intended to meet two goals: transfer contact loads away from the center of the joint, thus allowing contact to provide a larger internal moment to resist the large external varus moment; and reduce polyethylene strains by utilizing curved contacting surfaces on both the axle and the bushings (Fig. 2). After a sensitivity analysis to determine optimal dimensional choices (e.g., bushing and axle radii), we compared the resulting polyethylene strains between the Coonrad-Morrey and new design at locations that experienced the largest strains (Fig. 3). Substantial decreases were achieved, suggesting far less deformation and wear, which should relate to marked improvements in performance. Currently, we are incorporating this new design concept, along with alterations in stem design achieved from examination of load transfer at the fixation interfaces based on the same loading conditions, to achieve an implant system intended to improve the performance of TEA