Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 44 - 44
2 May 2024
Holleyman R Jameson S Reed M Meek D Khanduja V Judge A Board T
Full Access

This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip replacement for aseptic loosening.

We conducted a cohort study of first-time, single-stage revision hip replacements (RHR) performed for aseptic loosening and recorded in the National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man between 2003 and 2019. Patient identifiers were used to link records to national mortality data, and to NJR data to identify subsequent re-revision procedures. Multivariable Cox proportional hazard models with restricted cubic splines were used to define associations between volume and outcome.

Among 12,676 RHR there were 513 re-revisions within two years, and 95 deaths within 90 days of surgery. The risk of re-revision was highest for a consultant's first RHR (Hazard Ratio (HR) 1·58 (95%CI 1·16 to 2·15)) and remained significantly elevated for their first 26 cases (HR 1·26 (95%CI 1·00 to 1·58)). Annual consultant volumes of five/year were associated with an almost 30% greater risk of re-revision (HR 1·28 (95%CI 1·00 to 1·64)) and 80% greater risk of 90-day mortality (HR 1·81 (95%CI 1·02 to 3·21)) compared to volumes of 20/year. RHR performed at hospitals which had cumulatively undertaken fewer than 168 RHR were at up to 70% greater risk of re-revision (HR 1·70 (95% CI 1·12 to 2·60)), and those having undertaken fewer than 309 RHR were at up to three times greater risk of 90-day mortality (HR 3·06 (95% CI 1·19 to 7·86)).

This study found a significantly higher risk of re-revision and early postoperative mortality following first-time single-stage RHR for aseptic loosening when performed by lower-volume consultants and at lower-volume institutions, supporting the move towards the centralisation of such cases towards higher-volume units and surgeons.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 25 - 25
7 Jun 2023
Unsworth R Barrow J As-Sultany M Hastie G Siney P Board T Divecha H
Full Access

Mortality following revision hip surgery for periprosthetic fracture (PPF) has been reported to be as high as 60% at 5 years. The aim of this study was to determine the mortality rate for PPF revisions, compared to revision for aseptic loosening or infection at our tertiary referral centre.

Revision arthroplasty procedures performed for PPF, aseptic loosening or infection between January 2014 and December 2015 at our institution were identified using a prospectively collected PPF referral database and locally collected NJR data. Comparisons were made between the 3 groups for baseline demographics, admission to higher-level care, length of stay, complications, and Kaplan-Meier failure (mortality) at 1 & 5 years post-operative (with log-rank test for equality).

There were 37 PPF, 71 infected and 221 aseptic revisions. PPF had a higher proportion of females (65% vs. 39% in infection and 53% in aseptic; p = 0.031) and grade 3 and 4 ASA patients (p = 0.006). Median time to surgery from injury for PPF was 8 days (95% CI, 6–16). Single-stage procedures were performed in 84% of PPF, 42% of infection and 99% of aseptic revisions (p < 0.001). 19% of PPF revisions required HDU admission, 1% in the aseptic group and none in the infection group (p<0.001). Median length of stay was significantly different (PPF 10; infection 14; aseptic 8 days (p < 0.001). The Kaplan-Meier estimate of 1-year mortality were: PPF = 0%; infection = 2.8% (0.7–11.1%); aseptic = 0.9% (0.2–3.5%). 5-year mortality estimates were: PPF = 17.1% (8–34%), infection = 8.7% (4–18.3%), aseptic = 12% (8.4–17%). Log-rank test of equality was not significant, p=0.833.

Despite the PPF group having an average delay to surgery of 8 days, higher ASA grades and more admissions to HDU there was no significant difference in mortality rates between the groups at 1 and 5 years postoperatively. Using a coherent MDT approach with dedicated healthcare professionals this service demonstrates a low post operative mortality rate which merits further investment and development.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 92 - 92
4 Apr 2023
Li S Ding Y Wu C Lin S Wen Z
Full Access

For patients who took joint replacement, one of the complications, aseptic joint loosening, could cause a high risk of revision surgery. Studies have shown that MSCs have the ability of homing and differentiating, and also have highly effective immune regulation and anti-inflammatory effects. However, few studies had focused on the stem cells in preventing the occurrence and development of aseptic loosening. In this research, we aimed to clarify whether human umbilical cord mesenchymal stem cells could inhibited the aseptic joint loosening caused by wear particles.

A Cranial osteolysis mice model was established on mice to examine the effect of hUC-MSCs on the Titanium particles injection area through micro-CT. The amount of stem cells injected was 2 × 10 5 cells. One week later, the mouse Cranial were obtained for micro-CT scan, and then stained with HE analysis immunohistochemical analysis of TNF-α, CD68, CCL3 and Il-1β.

All mice were free of fever and other adverse reactions, and there was no death occurred. Titanium particles caused the osteolysis at the mice cranial, while local injection of hUC-MSCs did inhibit the cranial osteolysis, with a lower BV/TV and a higher porosity. Immunohistochemical results suggested that the expression of TNF-α, CD68, CCL3 and Il-1β in the cranial in Titanium particles mice increased significantly, but was significantly reduced in mice injected with hUC-MSCs. The inhibited CD68 expression indicated that the number of macrophage was lower, which might be a result of the inhibition of CCL3.

According to the studies above, HUC-MSCs treatment of mouse cranial osteolysis model can significantly reduce osteolysis, inhibit macrophage recruitment, alleviate inflammatory response, without causing adverse reactions. It may become a promising treatment of aseptic joint loosening.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening.

The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems.

There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001).

There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size.

High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 859 - 866
1 Jul 2022
Innocenti M Smulders K Willems JH Goosen JHM van Hellemondt G

Aims

The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome measures (PROMs).

Methods

We reviewed a prospective cohort of 647 patients undergoing full or partial rTHA at a single high-volume centre with a minimum of two years’ follow-up. The reasons for revision were classified as: infection; aseptic loosening; dislocation; structural failure; and painful THA for other reasons. PROMs (modified Oxford Hip Score (mOHS), EuroQol five-dimension three-level health questionnaire (EQ-5D-3L) score, and visual analogue scales for pain during rest and activity), complication rates, and failure rates were compared among the groups.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims

Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component.

Methods

A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).


The aim of this study is the comparative assessment of long term clinical (subjective and objective), functional and quality of life outcome data between primary and revision THA.

122 patients (130 hips) who underwent cementless revision THA of both components (TMT cup, Wagner SL stem, Zimmer Biomet) for aseptic loosening only (Group A) were compared to a matched group of 100 patients (100 hips) who underwent cementless primary THA for osteoarthritis (Synergy stem, R3 cup, Smith & Nephew) (Group B). Outcomes were evaluated with survival analysis curves, Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford hip score (OHS), Short form-12 health survey (SF-12) and EQ-5D-5L scales. Mobility was assessed with walking speed, timed up and go test (TUG), Parker mobility, Lower extremity function score (LEFS) and UCLA scores.

At a mean follow up of 14.4 years (10 to 20) a cumulative success rate of 96% (95% CI 96 to 99%) in Group A and 98% (95% CI 97 to 99%) in Group B with operation for any reason as an end point was recorded. Statistically significant differences between groups were developed for WOMAC (Mann-Whitney U test, p= 0.014), OHS (Mann-Whitney U test, p= 0.020) and physical component of SF-12 scores (Mann-Whitney U test, p= 0.029) only. In Group A, in multiple regression analysis, patients’ cognition (p=0.001), BMI (p=0.007) and pain (p=0.022) were found to be independent factors influencing functional recovery (WOMAC). Similarly, pain (p=0.03) was found to influence quality of life (EQ-5D-5).

In the long term, revision THA shows satisfactory but inferior clinical, functional, and quality of life outcomes when compared to primary THA. Residual pain, BMI and cognitive impairment independently affect functional outcomes.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 333 - 340
1 Jul 2020
Mumith A Coathup M Edwards TC Gikas P Aston W Blunn G

Aims

Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses.

Methods

A retrospective radiological analysis was performed on adult patients with distal femoral arthroplasties. In all, 16 patients were included in the chemotherapy group with 18 patients in the non-chemotherapy control group. Annual radiographs were analyzed for three years postoperatively. Dimensions of the bony pedicle, osseointegration of the hydroxyapatite (HA) collar surface, bone resorption at the implant shoulder, and radiolucent line (RLL) formation around the cemented component were analyzed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 130 - 130
1 Feb 2020
Ghaednia H Tallman T Owens C Hart A Varadarajan K
Full Access

INTRODUCTION

Joint replacement is one of the most common orthopaedic procedures, with over 2 million surgeries performed each year across the globe. Loss of implant fixation, or aseptic loosening, is the leading cause of revision following primary joint replacement, accounting for ∼25% of all revision cases [1]. However, diagnosis of aseptic loosening and its underlying causes remain challenging due to the low sensitivity and specificity of plain radiographs. To address this, we propose a novel approach inspired by [2] involving the use of a self-sensing bone cement (by imparting strain-dependent electrical conductivity or piezoresistivity) combined with electrical impedance tomography (EIT). Piezoresistivity is imparted to cement via incorporation of micro/nanoscale conductive fillers. Therefore mechanical effects such as loosening and cracks will manifest as a conductivity change of the cement. This work explores if EIT is able to detect strains and cracks within the bone cement volume.

METHODS

Experiments were designed to determine whether EIT combined with piezoresistive cement can be used to detect strains and cracks (Fig. 1). The setup consists of a tank filled with water, 16 electrodes, sample, a loading machine (MTS), and an EIT system. To develop the piezoresistive bone cement, microscale carbon fibers were used with varying CF/PMMA volumetric ratios (VR) from VR = 0.25% to 3.0%. Three conical samples were made to model a loading condition similar to knee implants (Fig. 1). The samples were compressed while the conductivity map of the tank was measured with the EIT system.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 111 - 111
1 Apr 2019
Beamish RE Ayre WN Evans S
Full Access

Objectives

Investigate the incorporation of an antibiotic in bone cement using liposomes (a drug delivery system) with the potential to promote osseointegration at the bone cement interface whilst maintaining antibiotic elution, anti-microbiological efficacy and cement mechanical properties.

Prosthetic joint infection and aseptic loosening are associated with significant morbidity. Antibiotic loaded bone cement is commonly used and successfully reduces infection rates; however, there is increasing resistance to the commonly used gentamicin.

Previous studies have shown gentamicin incorporated into bone cement using liposomes can maintain the cement's mechanical properties and improve antibiotic elution.

The phospholipid phosphatidyl-l-serine has been postulated to encourage surface osteoblast attachment and in a liposome could improve osseointegration, thereby reducing aseptic loosening.

Preliminary clinical isolate testing showed excellent antimicrobial action with amoxicillin therefore the study aims were to test amoxicillin incorporated into bone cement using liposomes containing phosphatidyl-l-serine in terms of antibiotic elution, microbiological profile and mechanical properties.

Methods

Amoxicillin was encapsulated within 100nm liposomes containing phosphatidyl-L-serine and added to PMMA bone cement (Palacos R (Heraeus Medical, Newbury, UK)).

Mechanical testing was performed according to Acrylic Cement standards (ISO BS 5833:2002). Elution testing was carried out along with microbiological testing utilising clinical isolates.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 97 - 97
1 Nov 2018
Greenfield E
Full Access

Considerable evidence exists that aseptic loosening is initiated by wear particles that recruit macrophages and stimulate their production of pro-inflammatory cytokines. The cytokines primarily act indirectly by inducing production of RANKL, which stimulates osteoclast differentiation, osteolysis, and inflammatory bone loss. There is also considerable evidence that activation of macrophage Toll-like Receptors (TLRs) contributes to this cascade of events. It is however controversial whether bacterially-derived immunostimulatory molecules known as Pathogen-Associated Molecular Patterns (PAMPs) can contribute to aseptic loosening by stimulating their cognate TLRs on macrophages. Priming and subsequent activation of the NLRP3 inflammasome is essential for macrophage production of mature, active IL-1β in response to wear particles. We recently confirmed that wear particles can activate pre primed NLRP3 inflammasomes in the absence of PAMPs. Thus, activation of the NLRP3 inflammasome is the only macrophage-based event in the aseptic loosening cascade that we have found to date is independent of PAMPs. In contrast, priming of the NLRP3 inflammasome by wear particles requires PAMPs as well as their cognate TLRs. These results add to the growing body of evidence that bacterially-derived PAMPs can contribute to aseptic loosening.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 83 - 83
1 Apr 2018
Hameister R Dheen ST Lohmann CH Kaur C Singh G
Full Access

Background

Mechanisms underlying implant failure remain incompletely described, though the presence of macrophage-mediated inflammatory reactions is well documented. Hypoxia has a critical role in many diseases and is known to be interdependent with inflammation. Metals used for joint replacements have also been reported to provoke hypoxia-like conditions. In view of this, we aim to investigate hypoxia-associated factors in aseptic loosening and osteoarthritis with a focus on macrophages.

Methods

Western blotting, calorimetric assay, haematoxylin-eosin staining, immunohistochemistry, double-immunofluorescence and transmission electron microscopy were performed on capsular tissue obtained from patients undergoing primary implantation of a total hip replacement for osteoarthritis and from patients undergoing revision surgery for aseptic loosening to investigate the presence of hypoxia-associated factors.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 11 - 11
1 Dec 2017
Kocjancic B Jeverica S Trampuz A Simnic L Avsec K Dolinar D
Full Access

Aim

The aim of our study was to evaluate culture-negative prosthetic joint infections in patients who were pre-operatively evaluated as aseptic failure.

Method

For the purpose of the study we included patients planed for revision surgery for presumed aseptic failure. Intraoperatively acquired samples of periprosthetic tissue and explanted prosthesis were microbiologicaly evaluated using standard microbiologic methods and sonication. If prosthetic joint infection was discovered, additional therapy was introduced.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 69 - 69
1 May 2017
Petra S Michal V Pavel D Regina F Eva K Jiri G
Full Access

Background

Inflammation and chemokines play a pivotal role in aseptic loosening (AL) and prosthetic joint infection (PJI) of total joint arthroplasty (TJA). Recently, the Duffy antigen receptor for chemokines (DARC) on erythrocytes was identified as a potent chemokine receptor able to bind and carry without deactivating a wide range of CXC and CC chemokines from circulation to tissues. The role of DARC and its functional polymorphism (SNP) influencing the number of the DARC molecules on the erythrocytes in AL/PJI has not been studied yet.

Methods

We genotyped functional polymorphism in the DARC gene (rs12075) using MassArray technology (Agena Bioscience) in 354 patients with TJA (hip and knee arthroplasties). Patients were further subdivided into those with a complication (AL, n = 110; PJI, n = 126) and a control group without complications for at least 10 years (n = 118). Statistics was performed by Plink 1.07 and relative entropy.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 276 - 282
1 Feb 2017
Mumith A Coathup M Chimutengwende-Gordon M Aston W Briggs T Blunn G

Aims

Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses.

Materials and Methods

The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 83 - 83
1 Dec 2016
Burnell C Flynn B Gascoyne T Stockwell K Turgeon T
Full Access

Non-large head Metal-on-metal (MoM) hip replacements were seen as a solution to concerns about implant wear in younger patients. Mid-term loosening of once well-fixed hydroxyapatite (HA) coated femoral stems was recently observed in select MoM patients upon revision surgery. Accordingly, an implant retrieval study was undertaken to examine the incidence of aseptic loosening of in HA-coated femoral stems with MoM, ceramic on ceramic (CoC) and metal on polyethylene (MoP) bearing couples.

A single-centre implant retrieval lab reviewed 44 hydroxyapatite (HA)-coated titanium wedge taper stems of the same design retrieved over a period of 9 years. Ten were MoM articulations, 23 MoP and 11 CoC. Head sizes ranged from 28 to 40 with only four 40mm heads, all of which were MoM. Reason for revision, duration of implantation, femoral head size, patient age and body mass index was recorded for each retrieval. Goldberg corrosion scores were determined for the taper surfaces of each retrieval, with ‘0’ indicating no corrosion and ‘3’ indicating severe corrosion. Logistic regression analysis, Wilcoxan Rank Sum and Fischer's exact test were used for statistical analysis.

Aseptic loosening was the listed reason for revision in 18 of 44 cases. MoM bearing was associated with increased probability of aseptic loosening (Odds ratio 7.1 (95%CI 1.1–47.0) p=0.042). Severity of corrosion was also associated with aseptic loosening (Odds ratio 2.75 (95%CI 1.1–6.6) p=0.02). Head size and patient age had no correlation. Median time to revision of implants for aseptic loosening was 4.5 years (range: 4.2–7.0 years) for MoM versus 1.4 years (range: 0.3–3.0) for other bearing couples (p=0.004). Aseptic loosening was categorised as early (<=2 years) or mid-term (>2 years). No MoM hips were revised for aseptic loosening in the first 2 years while 8 of the 11 mid-term revisions had MoM articulations (p=0.004). Taper corrosion was more severe in mid-term aseptic loosing cases (p=0.049).

MoM HA-coated hip replacements appear to be associated with increased mid-term aseptic loosening compared to other bearing couples. Patients with MoM HA-coated hip replacements should be monitored regularly beyond the initial 1 to 2 years following surgery. Future analyses will examine the presence and progression of femoral radiolucency prior to revision surgery to determine an approximate timeline of stem loosening in this patient cohort. This research highlights the importance of implant retrieval programs to assess post-revision implant characteristics for early identification of possible device issues.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 40 - 40
1 Jun 2016
Johal S Siney P Wroblewski B Purbach B Board T Jones HW
Full Access

Introduction

Large acetabular bone defects caused by aseptic loosening are common. Reconstruction of large segmental defects can be challenging. Various implants and operative techniques have been developed to allow further acetabular revision in cases where bone stock is poor. Reconstitution of bone stock is desirable especially in younger patients. The aim of the study was to review the clinical and radiological results of hip revision with structural acetabular bone grafts using fresh frozen allograft and cemented components.

Method

Between 1990 and 2014, 151 first time revisions for aseptic acetabular loosening with acetabular reconstruction with a fresh frozen structural allograft and cemented components were performed at our hospital.

Graft dimensions, number of screws used and socket coverage by the graft were measured on the post-operative AP radiograph.

Follow-up radiographs were analysed for socket loosening, quality of graft union, graft and graft resorption.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 105 - 112
1 Jan 2016
Khan M Osman K Green G Haddad FS

Total knee arthroplasty (TKA) is a cost effective and extremely successful operation. As longevity increases, the demand for primary TKA will continue to rise. The success and survivorship of TKAs are dependent on the demographics of the patient, surgical technique and implant-related factors.

Currently the risk of failure of a TKA requiring revision surgery ten years post-operatively is 5%.

The most common indications for revision include aseptic loosening (29.8%), infection (14.8%), and pain (9.5%). Revision surgery poses considerable clinical burdens on patients and financial burdens on healthcare systems.

We present a current concepts review on the epidemiology of failed TKAs using data from worldwide National Joint Registries.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):105–12.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1657 - 1662
1 Dec 2014
Stambough JB Clohisy JC Barrack RL Nunley RM Keeney JA

The aims of this retrospective study were to compare the mid-term outcomes following revision total knee replacement (TKR) in 76 patients (81 knees) < 55 years of age with those of a matched group of primary TKRs based on age, BMI, gender and comorbid conditions. We report the activity levels, functional scores, rates of revision and complications. Compared with patients undergoing primary TKR, those undergoing revision TKR had less improvement in the mean Knee Society function scores (8.14 (–55 to +60) vs 23.3 points (–40 to +80), p < 0.001), a similar improvement in UCLA activity level (p = 0.52), and similar minor complication rates (16% vs 13%, p = 0.83) at a mean follow-up of 4.6 years (2 to 13.4). Further revision surgery was more common among revised TKRs (17% vs 5%, p = 0.02), with deep infection and instability being the most common reasons for failure. As many as one-third of patients aged < 55 years in the revision group had a complication or failure requiring further surgery.

Young patients undergoing revision TKR should be counselled that they can expect somewhat less improvement and a higher risk of complications than occur after primary TKR.

Cite this article: Bone Joint J 2014; 96-B:1657–62


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 79 - 79
1 Sep 2012
Ailabouni R
Full Access

It has been suggested that occult infection of joint prostheses contributes to a proportion of aseptic loosening. The aims of the study were to determine the incidence of occult infection in a sample of patients undergoing revision surgery for aseptic loosening and examine the role of ultrasound sonication in its detection. A prospective trial was conducted at Christchurch and Burwood Hospitals. At the time of revision surgery, intra-operative tissue and fluid samples were taken. The removed prosthesis was immersed in saline solution in a sterile plastic container, and then sonicated. The sonicate fluid underwent prolonged routine cultures (14 days) to increase the rate of detection of slow growing organisms. The cases were patients undergoing revision surgery for aseptic loosening or infection. The control group was comprised of patients having revision surgery for any other indication. These implants were subjected to the same protocol as the study group. A total of 122 patients were included in the study; 54 in the Aseptic Loosening [AL] group, 15 Infections and 53 controls. There were significantly more smokers in the AL group and less smokers in the control group (p=0.04 and p=0.04 respectively). The mean age for revision in the Infection and Periprosthetic fracture groups was less than those of other groups (p=0.007 and p=0.02) respectively. There were 18 cases with positive intra-operative cultures. Eight of those were in the aseptic group (i.e. 14.8% of the group). Conventional sampling techniques were positive in 17 of 18 cultures (94%). Sonication was only positive in 10 out of the 18 cultures (56%). Sonication was concordant with the conventional sampling techniques in half of the positive cultures in the AL group and overall. The only bacteria to be isolated from sonicate cultures were Staphylococcus Aureus and Coagulase Negative Staphylococci. Diabetes Mellitus was the only risk factor to have a significant association with having a positive culture result (p=0.03). There was also a significant association with having raised pre-operative Neutrophil differential count or inflammatory markers with having a positive culture (p=0.0001). However this association was not present when the AL group was examined separately. There was a significant rate of positive culture results in the aseptic loosening group of around 15%. Ultrasound sonication was less sensitive than current sampling techniques with no apparent added benefit. This paper does not support the hypothesis that occult infection is a significant driver of aseptic loosening