Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Bone & Joint 360
Vol. 12, Issue 3 | Pages 37 - 40
1 Jun 2023

The April 2023 Children’s orthopaedics Roundup360 looks at: CT scan of the ipsilateral femoral neck in paediatric shaft fractures; Meniscal injuries in skeletally immature children with tibial eminence fractures: a systematic literature review; Post-maturity progression in adolescent idiopathic scoliosis curves of 40° to 50°; Prospective, randomized Ponseti treatment for clubfoot: orthopaedic surgeons versus physical therapists; FIFA 11+ Kids: challenges in implementing a prevention programme; The management of developmental dysplasia of the hip in children aged under three months: a consensus study from the British Society for Children's Orthopaedic Surgery; Early investigation and bracing in developmental dysplasia of the hip impacts maternal wellbeing and breastfeeding; Hip arthrodesis in children: a review of 26 cases with a mean of 20 years’ follow-up


Bone & Joint Open
Vol. 4, Issue 4 | Pages 219 - 225
1 Apr 2023
Wachtel N Meyer E Volkmer E Knie N Lukas B Giunta R Demmer W

Aims

Wrist arthroscopy is a standard procedure in hand surgery for diagnosis and treatment of wrist injuries. Even though not generally recommended for similar procedures, general administration of perioperative antibiotic prophylaxis (PAP) is still widely used in wrist arthroscopy.

Methods

A clinical ambispective dual-centre study was performed to determine whether PAP reduces postoperative infection rates after soft tissue-only wrist arthroscopies. Retrospective and prospective data was collected at two hospitals with departments specialized in hand surgery. During the study period, 464 wrist arthroscopies were performed, of these 178 soft-tissue-only interventions met the study criteria and were included. Signs of postoperative infection and possible adverse drug effects (ADEs) of PAP were monitored. Additionally, risk factors for surgical site infection (SSIs), such as diabetes mellitus and BMI, were obtained.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 461 - 467
1 Apr 2018
Wagener J Schweizer C Zwicky L Horn Lang T Hintermann B

Aims. Arthroscopically controlled fracture reduction in combination with percutaneous screw fixation may be an alternative approach to open surgery to treat talar neck fractures. The purpose of this study was thus to present preliminary results on arthroscopically reduced talar neck fractures. Patients and Methods. A total of seven consecutive patients (four women and three men, mean age 39 years (19 to 61)) underwent attempted surgical treatment of a closed Hawkins type II talar neck fracture using arthroscopically assisted reduction and percutaneous screw fixation. Functional and radiological outcome were assessed using plain radiographs, as well as weight-bearing and non-weight-bearing CT scans as tolerated. Patient satisfaction and pain sensation were also recorded. Results. Primary reduction was obtained arthroscopically in all but one patient, for whom an interposed fracture fragment had to be removed through a small arthrotomy to permit anatomical reduction. The quality of arthroscopic reduction and restoration of the talar geometry was excellent in the remaining six patients. There were no signs of talar avascular necrosis or subtalar degeneration in any of the patients. In the whole series, the functional outcome was excellent in five patients but restricted ankle movement was observed in two patients. All patients had a reduction in subtalar movement. At final follow-up, all patients were satisfied and all but one patient were pain free. Conclusion. Arthroscopically assisted reduction and fixation of talar neck fractures was found to be a feasible treatment option and allowed early functional rehabilitation. Cite this article: Bone Joint J 2018;100-B:461–7


Bone & Joint 360
Vol. 5, Issue 5 | Pages 32 - 34
1 Oct 2016


Bone & Joint Research
Vol. 5, Issue 6 | Pages 225 - 231
1 Jun 2016
Yeung M Kowalczuk M Simunovic N Ayeni OR

Objective

Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia.

Methods

A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to July 2015. Study parameters including sample size, definition of dysplasia, outcomes measures, and re-operation rates were obtained. Furthermore, the levels of evidence of studies were collected and quality assessment was performed.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1220 - 1225
1 Sep 2015
Chen LB Wang H Tie K Mohammed A Qi YJ

A total of 22 patients with a tibial avulsion fracture involving the insertion of the posterior cruciate ligament (PCL) with grade II or III posterior laxity were reduced and fixed arthroscopically using routine anterior and double posteromedial portals. A double-strand Ethibond suture was inserted into the joint and wrapped around the PCL from anterior to posterior to secure the ligament above the avulsed bony fragment. Two tibial bone tunnels were created using the PCL reconstruction guide, aiming at the medial and lateral borders of the tibial bed. The ends of the suture were pulled out through the bone tunnels and tied over the tibial cortex between the openings of the tunnels to reduce and secure the bony fragment. Satisfactory reduction of the fracture was checked arthroscopically and radiographically.

The patients were followed-up for a mean of 24.5 months (19 to 28). Bone union occurred six weeks post-operatively. At final follow-up, all patients had a negative posterior drawer test and a full range of movement. KT-1000 arthrometer examination showed that the mean post-operative side-to-side difference improved from 10.9 mm (standard deviation (sd) 0.7) pre-operatively to 1.5 mm (sd 0.6) (p = 0.001). The mean Tegner and the International Knee Documentation Committee scores improved significantly (p = 0.001). The mean Lysholm score at final follow-up was 92.0 (85 to 96).

We conclude that this technique is convenient, reliable and minimally invasive and successfully restores the stability and function of the knee.

Cite this article: Bone Joint J 2015;97-B:1220–5.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance. . There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation. (sd). 0.7) and 0.7 mm (. sd. 0.7) and 0.6 mm (. sd. 0.6) and 0.4 mm (. sd. 0.5), respectively; p = 0.18 and p = 0.35). . Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate. Cite this article: Bone Joint J 2015; 97-B:957–62


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 87 - 87
1 Apr 2013
Yamazaki H Kitahara J Kodaira H Seino S Akaoka Y
Full Access

Background. The usefulness of arthroscopic reduction for the intra-articular fracture of the distal radius has been reported, although it is technically difficult. Hypothesis. Our hypothesis is that the reduction using the external fixator is useful as equivalent to the arthroscopic reduction for the intra-articular fracture of the distal radius fracture in the fixation with the volar locking plate. Materials & Methods. The surgery was performed in both methods randomly for 40 patients; average age 64(24 to 92) years, 11 male, 29 female. Image evaluations were performed at 24 weeks after surgery. Ulnar variance, Radial inclination, Volar tilt in the X-ray image, and gap and step in the computed tomogram were evaluated. Clinical evaluation was performed at 6, 12, 24 weeks after surgery. Objective evaluations were ranges of motion and grip strength. Subjective evaluations were disabilities of the arm, shoulder, and hand (DASH). Results. The results of image and objective evaluation had no significant difference between the two groups. DASH in arthroscopic group was significantly inferior at 24 weeks because of minor complications. Discussion & Conclusion. The external fixator and the arthroscopy are equally valuable in reduction of articular surface


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 842 - 847
1 Jun 2012
Eberhardt O Fernandez FF Wirth T

We present our early experience of arthroscopic reduction of the dislocated hip in very young infants with developmental dysplasia of the hip (DDH). Eight dislocated hips, which had failed attempts at closed reduction, were treated by arthroscopy of the hip in five children with a mean age of 5.8 months (4 to 7). A two-portal technique was used, with a medial sub-adductor portal for a 2.7 mm cannulated system with a 70° arthroscope and an anterolateral portal for the instruments. Following evaluation of the key intra-articular structures, the hypertrophic ligamentum teres and acetabular pulvinar were resected, and a limited release of the capsule was performed prior to reduction of the hip. All hips were reduced by a single arthroscopic procedure, the reduction being confirmed on MRI scan. None of the hips had an inverted labrum. The greatest obstacle to reduction was a constriction of the capsule. At a mean follow-up of 13.2 months (9 to 24), all eight hips remained stable. Three developed avascular necrosis. The mean acetabular index decreased from 35.5° (30° to 40°) pre-operatively to 23.3° (17° to 28°). This study demonstrates that arthroscopic reduction is feasible using two standardised portals. Longer follow-up studies are necessary to evaluate the functional results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 98 - 98
1 Feb 2012
Kamineni S Lee R Sharma A Ankem H
Full Access

Radial head fractures with fragment displacement should be reduced and fixed, when classified as Mason II type injuries. We describe a method of arthroscopic fixation which is performed as a day case trauma surgery, and compare the results with a more traditional fixation approach, in a case controlled manner. We prospectively reviewed six Mason II radial head fractures which were treated using an arthroscopic reduction and fixation technique. The technique allows the fracture to be mobilised, reduced, and anatomically fixed using headless screws. All arthroscopic surgeries were conducted as day-cases. We retrospectively collected age and sex matched cases of open reduction and fixation of Mason II fractures using headless screws. The arthroscopic cases required less analgesia, shorter hospital admissions, and had fewer complications. The averaged final range of follow-up, at 1 year post-operation was 15 to 140 degrees in the arthroscopic group and 35 to 120 degrees in the open group. The Mayo Elbow Performance Score was 95/100 and 90/100 respectively. No acute complications were noted in the arthroscopic group, and a radial nerve neuropraxia [n=1], superficial wound infection [n=1], and loose screw [n=1]. Two patients of the arthroscopic group required secondary motion gaining operations [n=1 arthroscopic anterior capsulectomy for a fixed flexion contracture of 35 degrees, and n=1 loss of supination requiring and arthroscopic radial scar excision]. Three patients in the open group required secondary surgery [n=2 arthroscopic anterior capsulectomy for fixed flexion deformities, and n=1 arthroscopic anterior capsulectomy for fixed flexion deformities, and n=1 arthroscopic radial head excision for prominent screws, loss of forearm rotation, and radiocapitellar arthrosis pain]. The technique of arthroscopic fixation of Mason II radial head fractures appears to be valid, with respect to anatomical restoration of the fracture, minimal hospital admission, reduction in analgesia requirement, fewer complications, and a decreased need for secondary surgery


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 76 - 76
1 Mar 2010
Teraura H Yamano Y Sakanaka H Gotani H Komatsu T Mega R Kataoka T Sasaki K
Full Access

Introduction: To improve the therapeutic results for AO type C intraarticular distal radius fractures in young and middle-aged patients, it is important to achieve and maintain anatomical reduction, and evaluate and treat soft-tissue injuries. We previously employed arthroscopically assisted reduction and percutaneous pinning (ARPP) combined with external fixation. Since 2003, we have employed ARPP combined with open reduction and internal fixation (ORIF) using volar locking plates. Methods: The subjects were twenty-six patients under 60 years old. The patients comprised thirteen men and thirteen women aged from 16 to 57 (mean 43.5) years. The type of fracture according to the AO classification was C1 in six patients, C2 in ten, and C3 in ten. The follow-up period was 12–18 (mean 13.5) months. The radial inclination (RI), volar tilt (VT), and ulnar variance (UV) were measured radiographically at the time of injury, immediately after surgery, and at final evaluation. The Mayo wrist score was used for clinical evaluation. Results: Union was achieved in all patients. The triangular-fibrocartilage complex injury was detected in nineteen patients, the scapholunate-interosseous ligament injury in twenty-three, and the lunotriquetral-interosseous ligament injury in nineteen. Radiographic evaluation showed that the mean RI, VT, and UV at presentation, immediately after surgery, and at final evaluation was 12.8, 21.0, and 20.9 degrees, −15.4, 9.7, and 9.6 degrees, and 3.10, 0.30, and 0.35 mm, respectively. The Mayo wrist score averaged 87.6 points. Conclusion: Although treatment of AO type C intraarticular distal radius fractures is difficult, ARPP combined with ORIF achieved relatively good results


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant.

Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 440 - 440
1 Oct 2006
Kendoff D Pearle A Hüfner T Citak M Gösling T Krettek C
Full Access

Anatomic reduction and appropriate implant placement is essential for optimal treatment of intraarticular tibial plateau fractures. Standard intraoperative fluoroscopy provides limited visualization of the reduction and hardware placement compared with pre- or postoperative 3-D imaging modalities. As such, post-operative computer tomography (CT) has become a common procedure to evaluate the quality of the reduction and fixation. The Iso-C3D provides 3-D intraoperatively imaging to dynamically assess the surgical reduction and fixation at different anatomic regions. We report on our first 19 clinical tibial plateau fractures scanned intra-operatively with the Iso-C 3D. Between January and November 2003, 19 intraarticular tibia plateau fractures were scanned intraoperatively with the Iso-C3D (Siemens, Germany). No formal selection criteria were utilised except for the presence of a tibial plateau fracture. Operative procedures included 14 cases of open reduction internal fixation and 5 cases of internal fixation with arthroscopic assisted reduction. Imaging Technique: All patients were positioned on full-carbon tables for the operative procedure. After initial operative reduction and fixation, conventional two-dimensional fluoroscopic imaging was performed using standard AP and lateral projections. These images were evaluated by the operating surgeon; if the reduction and fixation was judged to be appropriate, Iso-C3D imaging was initiated. In 21% (n=4) of all cases an immediate revision of the operative procedure was performed after Iso-C3D imaging. These revisions were not deemed necessary with conventional fluoroscopy alone. In two cases, significant intra-articular incongruencies (greater than two millimetres) were noted. Additionally, in two cases, implant mal-position was detected. All patients had a postoperative CT scan. All CT scans confirmed the intraoperative Iso-C imaging, no further additional articular incongruencies or malpositioned implants were identified. When compared to conventional C-arm images, the Iso-C 3D scans demonstrated improved ability to identify the articular malreduction and implant mal-position in all cases. We have demonstrated that the Iso-C3D provides reliable intraoperative evaluation of reduction and hardware placement compared to traditional CT scans for tibial plateau fractures. In addition, clinically relevant intra-operative information was gained with its use in this study. In four (21%) cases, the operative treatment was modified due to the use of the multiplanar imaging modality. On average, 10 minutes of additional operative time was required for the use of Iso-C3D scanning and the evaluation of the images. Further prospective clinical studies are needed to improve our findings


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 332 - 332
1 May 2006
Martínez S Pelfort X Tey M Monllau J
Full Access

Introduction and purpose: Fractures of the tibial plateau account for 1% of the total. Among them, 55–70% involve the lateral plateau with differences in separation and subsidence. Minimally invasive osteosynthesis under arthroscopic control increases the indications in these cases. Our purpose is to assess the long-term clinical and radiological outcomes. Materials and methods: We carried out a retrospective analysis of the medium-term results of closed fractures of the tibial plateau treated with arthroscopic reduction and percutaneous fixation with cannulated screws. A series of 32 patients with displaced fractures of the tibial plateau underwent surgery between 1993 and 2004. We used the AO classification. We analysed the clinical, functional and radiological results. Results: The mean follow-up was 6 years. We treated 12 type 41B1, 7 type 41B21, 5 type 41B22, 7 type 41B31 and 1 type 41B12. All the fractures were consolidated and 79.1% had anatomical reduction. External meniscal injuries that could be sutured were present In 11 cases (34.3%). Joint balance was complete in 24 knees. According to the Lysholm scale 23 had an excellent outcome and 9 good. One case presented infection of the surgical wound, which was resolved by surgical debridement and antibiotic therapy. Conclusions: The results suggest that this is a good method for treating selected fractures of the tibial plateau


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 187 - 187
1 Mar 2006
Basdekis G Varitimidis S Dailiana Z Hantes M Bargiotas K Malizos K
Full Access

Purpose: Arthroscopy offers a view of intra-articular pathology, but its use in the treatment of intra-articular distal radius fractures remains controversial. This study compares functional and radiologic outcomes of arthroscopically assisted (AA) versus fluoroscopically assisted (FA) reduction and external fixation (EF) of distal radius fractures.

Type of study: double randomised prospective, comparison of 2 different procedures.

Methods: Between January 2000 and December 2003, 20 patients with comminuted intra-articular distal radius fractures underwent AA EF and percutaneous pinning and 20 patients underwent and FA EF reduction and pinning.

Results: Follow-up period was 9–27 months. Evaluation was clinical (grip strength, range of motion) and radiographic (palmar tilt, radial shortening, stepoff). The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and the MAYO wrist score were used 3-9-12 months postoperatively. In 9/20 patients of AA group the subchodral pins were changed after artrhroscopic view because of stepoff. The following tears were found: TFCC (12 of 20 patients), SL (9/20), LT (4/20). Patients who underwent AA surgery had significantly better supination; wrist extension; and flexion compared with the FA surgery group (86 vs 75; 76 vs 65; and 76 vs 63 degrees respectively). Radial shortening and DASH scores were better for the AA group compared to the FA group (AA:12, FA:25) the 3rd and 6th postoperative month but the difference decreased after the 12th month.

Conclusions: A reduction and fixation of intra-articular distal radius fractures provides improved inspection of the ulnarsided components of the injury. Long term evaluation revealed that patients with AA procedures returned in decreased periods to their previous activities (based on DASH score) and had better of supination, flexion, and extension than patients with FA surgery.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 219 - 219
1 Nov 2002
Kitano T Komatsu T Sakai T Yamano Y
Full Access

Open reduction for developmental dislocation of the hip (DDH) is invasive and sometimes results in femoral head deformity while open reduction has been the first choice in case non-operative reduction is failed in. We treated 3 patients with 3 affected hips using minimum invasive arthroscopic reduction method. Pre-operative MRIs represented these 3 hips had obstruction of interposed thick limbus. The average age of patients treated by this method was 23 months. This method consists of arthrogram, arthroscopic limboplasty, and arthroscopic reduction. This series of maneuvers was able to lead unreducable hips to the reduction position. Post-operative MRIs represented that the interposed thick limbus had been removed to the outside of acetabulum and the limbus covered the reduced femoral head. There were no signs of residual subluxation of the hips in radiographic examination. This new minimum invasive arthroscopic reduction method have a possibility to take the place of the invasive open reduction in the treatment of DDHs with obstruction of interposed thick limbus


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 477 - 480
1 Aug 1982
McLennan J

Thirty-five patients were treated for Type III fractures of the intercondylar eminence of the tibia and were followed up for two to seven years. There were 20 Type IIIA fractures and 15 Type IIIB fractures. The avulsed fragment was reduced by operative arthroscopy and maintained either by extension and immobilisation in a cast or by crossed percutaneous pin fixation. Involvement of the medial collateral ligament or lateral meniscus was confirmed by valgus stress radiographs and by arthroscopy. Primary surgical repair through a separate incision was required in a significant number of patients. At follow-up, few patients suffered ligamentous instability, lack of extension, atrophy of the quadriceps, pain or effusion, and symptoms were minimal. Patients requiring surgical repairs of collateral ligaments or of peripheral detachments of the meniscus generally required a longer period of rehabilitation. Arthroscopic reduction and percutaneous pin fixation provided an effective treatment and significantly decreased the time spent in hospital and the morbidity experienced after alternative treatments