Hip joint biomechanics can be altered by abnormal morphology of the acetabulum and/or femur. This may affect load distribution and contact stresses on the articular surfaces, hence, leading to damage and degradation of the tissue. Experimental hip joint simulators have been used to assess tribology of total hip replacements and recently methods further developed to assess the natural hip joint mechanics. The aim of this study was to evaluate articular surfaces of human cadaveric joints following prolonged experimental simulation under a standard gait cycle. Four cadaveric male right hips (mean age = 62 years) were dissected, the joint disarticulated and capsule removed. The acetabulum and femoral head were mounted in an anatomical hip simulator (Simulation Solutions, UK). A simplified twin peak gait
Reorientating pelvic osteotomies are performed to improve femoral head coverage and secondary degenerative arthritis. A rectangular triple pelvic innominate osteotomy (3PIO) is performed in symptomatic cases. However, deciding optimal screw fixation type to avoid complications is questionable. Therefore, this study aimed to investigate the biomechanical behavior of two different acetabular screw configurations used for rectangular 3PIO osteosynthesis. It was hypothesized that bi-directional screw fixation would be biomechanically superior to mono-axial screw fixation technique. A rectangular 3PIO was performed in twelve right-side artificial Hemi-pelvises. Group 1 (G1) had two axial and one transversal screw in a bi-directional orientation. Group 2 (G2) had three screws in the axial direction through the iliac crest. Acetabular fragment was reoriented to 10.5° inclination in coronal plane, and 10.0° increased anteversion along axial plane. Specimens were biomechanically tested until failure under progressively increasing cyclic loading at 2Hz, starting at 50N peak compression, increasing 0.05N/cycle. Stiffness was calculated from machine data. Acetabular anteversion, inclination and medialization were evaluated from motion tracking data from 250-2500 at 250 cycle increments. Failure
Reverse shoulder arthroplasty (RSA) is commonly used to treat patients with rotator cuff tear arthropathy. Loosening of the glenoid component remains one of the principal modes of failure and is the main complication leading to revision. For optimal RSA implant osseointegration to occur, the micromotion between the baseplate and the bone must not exceed a threshold of 150 µm. Excess micromotion contributes to glenoid loosening. This study assessed the effects of various factors on glenoid baseplate micromotion for primary fixation of RSA. A half-fractional factorial experiment design (2k-1) was used to assess four factors: central element type (central peg or screw), central element cortical engagement according to length (13.5 or 23.5 mm), anterior-posterior (A-P) peripheral screw type (nonlocking or locking), and bone surrogate density (10 or 25 pounds per cubic foot [pcf]). This created eight unique conditions, each repeated five times for 40 total runs. Glenoid baseplates were implanted into high- or low-density Sawbones™ rigid polyurethane (PU) foam blocks and cyclically loaded at 60 degrees for 1000 cycles (500 N compressive force range) using a custom designed loading apparatus. Micromotion at the four peripheral screw positions was recorded using linear variable displacement transducers (LVDTs). Maximum micromotion was quantified as the displacement range at the implant-PU interface, averaged over the last 10
Shoulder arthroplasty humeral stem design has evolved to accommodate patient anatomy characteristics. As a result, stems are available in numerous shapes, coatings, lengths, sizes, and vary by fixation method. This abundance of stem options creates a surgical paradox of choice. Metrics describing stem stability, including a stem's resistance to subsidence and micromotion, are important factors that should influence stem selection, but have yet to be assessed in response to the diametral (i.e., thickness) sizing of short stem humeral implants. Eight paired cadaveric humeri (age = 75±15 years) were reconstructed with surgeon selected ‘standard’ sized short-stemmed humeral implants, as well as 2mm ‘oversized’ implants. Stem sizing conditions were randomized to left and right humeral pairs. Following implantation, an anteroposterior radiograph was taken of each stem and the metaphyseal and diaphyseal fill ratios were quantified. Each humerus was then potted in polymethyl methacrylate bone cement and subjected to 2000 cycles of 90º forward flexion loading. At regular intervals during loading, stem subsidence and micromotion were assessed using a validated system of two optical markers attached to the stem and humeral pot (accuracy of <15µm). The metaphyseal fill ratio did not differ significantly between the oversized and standard stems (0.50±0.06 vs 0.50±0.10; P = 0.997, Power = 0.05); however, the diaphyseal fill ratio did (0.52±0.06 vs 0.45±0.07; P < 0.001, Power = 1.0). Neither fill ratio correlated significantly with stem subsidence or micromotion. Stem subsidence and micromotion were found to plateau following 400
Introduction. The use of bone cement as a fixation agent has ensured the long-term functionality of THA implants . 1. However, some studies have shown the undesirable effect of wear of stem-cement interface, due to the release of metals and polymeric debris lead to implant failure . 2,3. Debris is generated by the micromotion together with a severely corrosive medium present in the crevice of stem-cement interface . 3,4. FEA studies showed that micromotion can affect osseointegration and fretting wear . 5,6. The aim of this research is to investigate if the micromotions measures from in silico analysis of the stem-cement correlate with the fretting-corrosion damage observed on in vitro testing. Methods. The in vitro fretting-corrosion testing was made with positioning and loading based on ISO 7206-4 and ISO 7206-6. It was used Exeter stems embedded in bone cement (PMMA) and immersed in a saline solution (9.0 g/L of NaCl). A fatigue testing system (Instron 8872, USA) was used to conduct the test, applying a sinusoidal cyclic load at 5.0 Hz. The tests were finished after 10 million cycles and images of stem surfaces were taken with a photographic camera (Canon EOS Rebel T6i, Japan) and a stereoscope (Leica M165C, Germany). For the computational analysis, the same testing configurations were modeled on software ANSYS. The analysis was performed using linear isotropic elasticity for both stem (E=193GPa; ⱱ=0.27; σ. y. =400MPa) and PMMA cement (E=2.7GPa; ⱱ=0.35; σ. u. =76MPa). 7,8. . A second-order tetrahedral element was used to mesh all components with a size of 0.5 mm in the stem-cement contact area, increasing until 1.0 mm outside from them. A frictional contact (µ=0.25) with an augmented Lagrange formulation was used. The third
Posterior internal fixation systems undergo internal constraints resulting in high load bearing requirement for the pedicular screw/bone interface. Only few studies deal with the impact of the vertebral augmentation on the migration of pedicular screws. In this study, the impact of the pedicular screw augmentation has been investigated under physiological load for osteoporotic vertebras. The data have been proceeded to reduce the influence of vertebral geometry, which generally leads to results devoid of statistical meaning. In 8 osteoporotic vertebrae, two screws have been inserted in each vertebra: a non-augmented on one side and an augmented one on the contralateral side. Compression tests have been performed (two consecutive 50
We compared the initial strength of two techniques for repair of rotator cuff tears. Eight paired cadaveric shoulders with a standardized supraspinatus defect were studied. A transosseous suture and anchor repair was conducted on each side. Specimens were tested under cyclic loading, while fixation was monitored with an optical tracking technique. Mode of failure, number of
Introduction. Manifestation of high interface stresses coupled with micromotion at the interface can render the taper lock joint in a modular hip replacement prosthesis at risk for failure. Bending can lead to crevice formation between the trunnion and the head and can potentially expose the interface to the biological fluids, generating interface corrosion. Additionally, development of high stresses can cause the material to yield, ultimately leading to irreversible damage to the implant. The objective of this study is to elucidate the mechanical response of taper junction in different material combination assemblies, under the maximum loads applied during everyday activities. Methods. Computer simulations were executed using a verified FE model. A stable hexahedral mesh (33648 elements) was generated for the trunnion (taper size: 12/14mm) and a tetrahedral mesh (51182 elements) for the head (CoCr, size: 32mm). An assembly load of 4000N was applied along the trunnion axis followed by the application of a load of 230–4300N at 25° and 10° angle to the trunnion axis in the frontal and sagittal planes. A linear static solution was set up using Siemens NX Nastran. Two material combinations were tested - cobalt-chrome head with a titanium alloy trunnion and cobalt chrome head with a cobalt-chrome trunnion. Results. Table1 compares the results obtained from the simulation to those observed in experimental simulations performed under similar loading conditions in our lab. Larger vertical interface displacement was observed in the CoCr-CoCr assembly during toggle-inducing loads. The trunnion bending inside the femoral head was higher in the Ti-CoCr assembly (0.056) compared to the CoCr-CoCr assembly (0.027) with the overall bending of the Ti-CoCr assembly also observed to be much higher (Fig.1). Negligible difference between the stress measured in the femoral head and taper was observed (Fig.2). Discussion. Bending could potentially lead to the development of higher stresses especially under multiple
Aim. To delineate which of four common and easily constructed Ilizarov frame configurations is best at resisting shear displacement. Methods. Four Ilizarov frames were constructed on Sawbones™ Tibiae taking into account soft tissue and neuro-vascular limitations in frame design. The designs consisted of a standard all wire frame, an opposing olive wire standard frame, a perpendicular trans-fracture opposing olive wire frame and a perpendicular half pin frame. These were tested over three cycles in compression on a load-testing machine with movement in the plane of the fracture measured using a clip gauge. Each frame was tested to the maximum displacement of the clip gauge or a total single
For the treatment of the fractures of the proximal extremity of the femur two predominant systems exist: the intramedular nail and the sliding screw plate. The variables at the moment, to be considered, are the weight, age and type of fracture. The principal aims are: To develop models of finite elements of both types of implants and of two types of fracture (stable and unstable), and to integrate the models of finite elements of the implants in the model of fractured femur, to obtain the mechanical behavior of both types of implants and them to fit to the model of finite elements. The analyzed models have been the gamma-3 nail (Stryker, USA) and the PerCutaneus Compression Plate (PCCP), (Gotfried, Israel). The real geometry has been created in the program SolidWorks 11.0 to be treated later in the program of calculation by means of finite elements Ansys. The assembly with nail is more rigid (11.51 mm) that with plate (11.95 mm) on having had a few minor displacements. The tensions that appear in the nail (446 MPa) are major that those of the plate (132.93 MPa), in the unstable fractures. In the unstable fractures, the intramedular nail is more rigid than the system of plate. The tensions to which the nail meets submitted are superior to those of break for what the nail would not be capable of supporting the first
Summary. Consistent load distributions with over-sizing of radial head implants show minimal variance in interosseus ligament (IOL) and triangular-fibrocartilage complex (TFCC) tension, both of which are essential in distribution of load at the elbow. Introduction:Changes in loading distribution at the elbow have not been studied with radial head (RH) arthroplasty. Difficulty arises concerning distribution variability between loading methods and magnitudes, and with implant oversizing. Method. RC joint capsule were exposed using the Kocher approach in seven fresh-frozen cadaver Humeri. Specimens were loaded axially in an MTS machine with humeri at 90° and wrist neutral. The arms were
Joint load reduction is effective for alleviating OA pain. Treatment options for joint unloading include braces and HTO, both of which may be impractical for patients. The purpose of the present study was to examine the biomechanical rationale of a practical, partial unloading implant (KineSpring® System, Moximed) for knee OA. Device durability was tested by cyclically loading bone-implant constructs through simulated use for at least 10 million
Summary Statement. The tensile properties of a number of synthetic fibre constructs and porcine MCLs were experimentally determined and compared to allow the selection of an appropriate synthetic collateral ligament model for use in a kinematic knee simulator. Introduction. As patient expectations regarding functional outcomes of total knee arthroplasty rise the need to assess the kinematics of new implants in vitro has increased. This has traditionally been done using cadaveric models, which can demonstrate high physiological relevance but also substantial inter-specimen variability. More recently there has been a shift towards the use of in silico and non-cadaveric methods. Such methods require significant simplifications of the joint and the modelling of soft tissue structures such as the collateral ligaments. Collateral ligaments are often modelled in in silico studies but have not, in the published literature, been modelled in in vitro knee kinematic simulators. Tensile testing of ligament tissue, to provide reference data, and the subsequent analysis of potential synthetic analogues was carried out. The overall aim of the study was to develop a synthetic ligament analogue for use in kinematic knee simulators. Methods. Porcine MCLs were chosen as these are of a similar size and are a readily available alternative to human ligaments. Six porcine knee specimens were sourced and the MCLs dissected by an orthopaedic registrar. Testing was carried out on an Instron MTS fitted with a 5kN load cell. Each specimen was subjected to 5 pre-conditioning
Aims: The purpose of this study was to assess the effect of changes in peripheral attachment on stresses and displacements at the liner-shell interface. Methods: Three dimensional þnite element models were constructed of two acetabular cup designs for a liner with a 32 mm inner diameter, a liner thickness of 5 mm, and a shell thickness of 4 mm. An additional set of models was constructed with a 28 mm head diameter, corresponding to a liner thickness of 7 mm. 16 sequential quasistatic loading steps were used to describe the stance phase of a patientñs gait cycle. Results: Changes in the design had a larger inßuence on the backside relative motion during the gait
Femur fractures are a complication of hip arthroplasty. When the stem is well fixed, fracture fixation is the preferred treatment option. Numerous fixation methods have been advocated, using plates and/or allograft struts. The study was conducted to determine the biomechanical characteristics of three constructs currently used for fixation of these fractures. Vancouver type B1 periprosthetic femur fractures were created distal to a cemented hip stem implanted in third generation composite femurs. The fractures were fixed with one of three constructs: 1- A non-locking plate and allograft strut (NLP-A) 2- A locking plate and allograft strut (LP-A) 3- A locking plate alone. (LP) The struts were held in place with cables. There were five specimens in each group. Following fixation, the constructs underwent sinusoidal cyclic loading from 200 to 1200 N for 100000 cycles. Stiffness of the constructs was determined in bending, torsion and axial compression before and after cyclic loading. Axial load to failure was also determined. Overall, cyclic loading had little effect on the mechanical properties of these constructs. The two constructs with allografts were significantly stiffer in coronal plane bending than the construct consisting of only a locking plate. There were no significant differences in axial or torsional stiffness between the constructs. Load to failure of the NLP-A (4095 N) and LP-A (4007 N) constructs was significantly greater than the LP construct (3398 N) (p=0.023 and p=0.044 respectively). All three constructs tested retained their mechanical characteristics following 100000
Background: The purpose of this study was to compare the stability of the 2.4 mm palmar locking compression plate (LCP) and a new intramedullary nail-plate-hybrid Targon DR (TDR) for dorsally comminuted distal radius fractures. Methods: An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen distal radii to simulate an AO-A3-fracture. The fractures were stabilized with one of the fixation constructs. The specimens were loaded axially with 200 N and dorsal-excentically with 150 N. Cyclic loading with 2000 cycles as well as loading to failure were performed under axial loading. Results: Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369N/mm) was significantly (p=0.017) stiffer than plate osteosynthesis (LCP: 131 N/mm). With 214 N/mm the intramedullary nail was also more stable during dorsal excentric loading than the LCP with 51 N/mm (p=0.012). After the 2000 cycles of axial loading with 150 N the Targon group was still significant stiffer than the LCP group under both loading patterns. Neither group showed a significant change in stiffness after the 2000 cycles. The Targon DR group even showed a slight increase with 435,22 N/mm (p = 0.161), while the LCP group showed a slight decrease with 122.24 N/mm (p = 0.575) during axial loading. Under dorsal excentric loading the Targon group was still significant stiffer with 212.46 N/mm than the LCP group with 44.96 N/mm (p=0.012). The load to failure tests demonstrated again the superiority of intramedullary nailing (625N) when compared to plate osteosynthesis (403N) (p<
0.025). Conclusions: The study shows that both implants are able to withstand physiological loads occuring under unloaded wrist motion. Neither implant showed a significant loss of stability after 2000
In recent years UHMWP sutures have gained more and more popularity in shoulder surgery. They have an increased tensile strength but were shown to have a higher rate of knot slippage due to their smooth surface. There exist different testing protocols on suture testing in dry or in wet conditions. The purpose of this study was to gain some inside as to whether or not the knot security of sliding and non-sliding knots with different suture materials is influenced by dry or wet testing conditions. We tested five common suture materials, all of them USP #2. The PDSII, the Ethibond and three ultra high molecular weight polyethylene (UHMWPE) sutures: Fiber Wire, Orthocord and Herculine. As non-sliding knots we used Square knot and Revo knot and for sliding knots we used Fisherman and Roeder knot. 10 samples of each knot type were tested. In the first group knot tying and biomechanical testing were performed under dry conditions. In the second group the sutures were soaked in saline solution for 3 min. before knot tying and afterwards tested in saline bath. Cyclic loading was performed to simulate the physiological conditions. We started with a tensile load of 25 N. After 100
Purpose: To compare the torsional stability provided by five implant stems with different cross-sectional geometries under cyclic loading. Methods: Cemented stems with five different cross-sectional shapes – circular, oval, triangular, rectangular with rounded edges (round rectangular), and rectangular with sharp edges (sharp rectangular) – were custom machined from stainless steel. Stem dimensions were selected to fit within the humeral canal (based on a 6mm x 8mm dimensioning scheme) and shapes were based on commercially available-designs. Seven specimens of each stem shape were tested. ||The stems were potted in square aluminum tubes using bone cement, and allowed to cure for 24 hours prior to testing. A materials testing machine and a custom designed loading fixture were used to apply torsion to the stems. A sine wave loading pattern was applied until ultimate failure (5° of stem rotation) was reached. This loading pattern had a lower bound of 0.9Nm and an upper bound that started at 4.5Nm and was increased in increments of 2.25Nm every 1500
Single-strand medial collateral elbow ligament (MCL) reconstruction strength was evaluated using double docking (DD) and interference screw (IS) methods with either palmaris longus (PL) or Graft Jacket_ (GJ) as the reconstruction material. Thirteen upper-extremities were mounted in 90° valgus orientations, and subjected to increasing cyclic valgus loading until failure. DD reconstructions outperformed IS reconstructions (P<
0.05), while PL and GJ performed comparably (P>
0.05). The initial Graft Jacket strength makes it a potential alternative to palmaris longus tendons; Laboratory evaluation of graft strength during healing is required. For its simplicity and strength, the DD technique should be considered, clinically. Single-strand medial collateral elbow ligament (MCL) reconstruction strength was evaluated using double docking (DD) and interference screw (IS) methods with either palmaris longus (PL) or Graft Jacket_ (GJ) as the reconstruction material. Thirteen, fresh-frozen upper-extremities (66 ±5 years) were cleaned of all soft tissues except the medial and lateral collateral ligaments, flexed to 90° and mounted in a rigid, valgus testing system. DD or IS reconstructions were performed using either PL or GJ. A cyclic (0.5Hz) load was applied 12cm distal to the medial epicondyle. After 500