header advert
Results 1 - 20 of 4382
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 106 - 106
1 Dec 2020
Thimmaiah R Ali O Mathur K
Full Access

The Hospital (Trust) guidelines generally recommend 40mg of Low molecular weight heparin (LMWH) twice daily (BD) for all patients over 100kg for those undergoing total hip (THR) and knee replacements (TKR) respectively. British National Formulary (BNF) recommends 40mg of LMWH once daily (OD) for all patients regardless of their overall weight or body mass index (BMI).

We evaluated the outcome of prophylactic LMWH dosage for patients undergoing THR and TKR by monitoring surgery related venous-thromboembolic events up to a minimum of three months after surgery.

A retrospective audit was carried out after obtaining institutional approval and all consecutive elective patients weighing over 100kg and undergoing THR and TKR were included. All patients were followed up for a minimum of 3 months after their operation to investigate the dose of prophylactic LMWH received, and whether they had developed any venous thromboembolic events (VTE) post operatively. This was done using a combination of electronic notes, drug charts and deep venous thrombosis (DVT) or computed tomography pulmonary angiogram (CTPA) reports on the hospital/trust database.

A total of 53 patients underwent elective THR (18) and TKR (35) between the period of March 2017 and September 2017. Forty-four patients received 40 mg OD and 9 patients had 40 mg BD. None of the patients developed a confirmed DVT or pulmonary embolism in the 3 months following surgery regardless of the dose received.

We demonstrate that there is no clinical benefit in having patients over 100kg on twice daily LMWH with the aim of preventing post-op thromboembolic complications. This conclusion is in line with the BNF recommendations for VTE prophylaxis.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 338 - 338
1 May 2006
Debi R Bar-Ziv Y Efrati S Cohen N Kardosh R Halperin N Segal D
Full Access

Introduction: Total hip arthroplasty preformed with the use of minimal incision surgery has received tremendous attention recently. Various surgical approaches have been introduced to minimize surgical trauma to the soft tissues. The mini invasive Modified Watson-Jones approach have been selected to decrease the perioperative complications associated with other mini invasive approaches that has been described. The anterolateral mini incision is a new innovative approach using the intramuscular plan between the gluteus medius and the tensor fascia lata. This intermuscular interval through a small incision provides good exposure and preserves muscle integrity. Moreover, preserving the muscle integrity provides a very stable joint after implantation such that no restrictions is giving to the patient during the rehabilitation period. Materials and Methods: Between July 2004 to September 2005, we used this approach on 60 sequential patients. Fifty patients were enrolled in this prospective study. Patients were evaluated preoperatively, immediately postoperatively, and at 3-month and 6 month follow-up according to operating time, intraoperative blood loss, subcutaneous drains blood loss, post op pain control drugs requirements, short form 36 patient questionnaire (SF-36) scores and the Harris Hip Score (HHS). 4 patients had previous THA on the contralteral side. Results: The average operation time was 137min (range 90–200min), there were no dislocations, the mean post operation blood transfusion requirements was 1.64, the mean subcutaneous drains blood loss was 241.9ml (range 20–620ml), there was significant improvement in function, pain, SF-36 and Harris Hip Score (HHS) at the 3-month and 6-month follow-up examination. The average length of the incision was under 12cm. We had one reoperation due to deep infection. All four patients with bilateral THA preferred their last operation due to lack of post operative restrictions and due to shorter recovery of muscle strength. Conclusion: We think that using mini invasive Modified Watson-Jones approach in total hip replacement surgeries is a preferable option. There are several advantages of using this approach compared with the more traditional techniques. Such a technique should help reduce morbidity and complication rates for those patients undergoing a total hip replacement


Abstract. Objectives. Hip instability following total hip arthroplasty in treatment of intracapsular neck of femur fractures is reported at 8–11%. Utilising the principle of a small articulation to minimize the problems of wear coupled with a large articulation, dual-mobility total hip arthroplasty prostheses stabilise the hip further than conventional fixed-bearing designs. The aim of this study is to compare the rate of dislocation and complication between standard fixed-bearing and dual-mobility prostheses for the treatment of intracapsular neck of femur fractures. Methods. A four-year retrospective review in a large district general hospital was completed. All cases of intracapsular neck of femur fractures treated with total hip arthroplasty were identified through the theatre logbooks. Patient's operative and clinical notes were retrospectively reviewed to collect data. Results. A total of 91 patients underwent total hip arthroplasty for intracapsular neck of femur fracture in the four-year period. 61.5% were dual-mobility design versus 28.5% had fixed-bearing implants. There were no statistical differences between patient group characteristics. Choice of implant was dependent on surgeon preference. There was a 0.0% dislocation rate in the dual-mobility group versus 8.6% in the fixed-bearing prosthesis group. All dislocations occurred in patients who underwent total hip arthroplasty with 36.0mm fixed-bearing prosthesis via posterior surgical approach. There was no statistical difference in mortality between both groups. Conclusion. There was an increasing trend of towards the use of dual-mobility prosthesis for fractured neck of femur within this department with excellent outcomes. Dual-mobility designs provide reduced dislocation rates in total hip arthroplasty in intracapsular neck of femur fractures compared to standard fixed-bearing designs at this institution. The authors recommend that all orthopaedic staff consider the use of dual-mobility prostheses in suitable patients and ensure trainees are suitably trained in use of dual-mobility designs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 6 - 6
8 Feb 2024
Ammori M Hancock S Talukdar P Munro C Johnston A
Full Access

The objectives of our study were to compare patient reported outcome measures between manual and robotic-assisted total hip arthroplasty. Between 1st May 2021 and 31st August 2022, 539 consecutive patients who underwent 564 primary total hip arthroplasties were identified from the local registry database. Data were prospectively collected, and included patient demographics, American Society of Anaesthesiologists (ASA) grade, surgical approach, robotic-assistance, Oxford Hip Score (OHS), EQ-5D-3L and EQ-VAS pre-operatively and at twelve months. Robotic-assistance, compared against manual total hip arthroplasty, was associated with an enhanced median (interquartile range) OHS (46 [42 – 48] vs 43 [36 – 47], p-value < 0.001), EQ-5D-3L (5 [5 – 7] vs 6 [5 – 8], p-value 0.002), and EQVAS (90 [75 – 95] vs 80 [70 – 90], p-value 0.003) at twelve months after surgery. Robotic-assistance was confirmed to be an independent predictor of a greater OHS at twelve months on a multivariate linear regression analysis (p-value 0.001). Robotic assistance was superior to manual total hip arthroplasty in enhancing patient reported outcomes at twelve months after surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 55 - 55
23 Jun 2023
Alqazzaz A Bush A Zhuang T Nelson CL
Full Access

Surgical management of acetabular fractures in older patients remains controversial. The purpose of this study is to compare outcomes of primary THA with outcomes after THA for acute acetabular fractures (aTHA) as well as outcomes following delayed THA (dTHA) following prior acetabular fracture.

We analyzed data from a large, national administrative claims database containing diagnostic, procedural, and demographic records from over 157 million patients. We identified all patients undergoing primary total hip arthroplasty THA continuously enrolled in the database at least 2 years prior and after the index procedure. Patients with an initial diagnostic code for acetabular fracture occurring the same day as the THA were classified as acute acetabular fractures. Patients with an initial acetabular fracture diagnostic code occurring at least 6 months before THA were classified as chronic acetabular fractures. The comparator group was patients undergoing THA with no history of acetabular fracture. There were 426,734 patients undergoing primary THA, 235 patients undergoing aTHA and 1,255 patients undergoing dTHA.

Patients with an aTHA had higher complication rates, including revisions (9.8% vs 5.6%,), dislocations (8.9% vs 6.4%), and periprosthetic fracture (5.1% vs 2.3%) compared to dTHA. After adjusting for age, sex, region, and comorbidities, receiving an aTHA increased the odds of revision (OR = 3.65 [95% CI: 2.30–5.49]), dislocation (OR = 4.09 [95% CI: 2.53–6.27]), and periprosthetic fracture (OR = 4.29 [95% CI: 2.26–7.36]) compared to primary THA. Receiving a dTHA significantly increased the odds of revision (adjusted OR = 1.80 [95% CI: 1.40–2.27]), dislocation (adjusted OR = 2.50 [95% CI: 1.97–3.13]), and periprosthetic fracture (adjusted OR = 1.99 [95% CI: 1.34–2.83]) compared to primary THA.

Patients undergoing aTHA in the treatment of an acetabular fracture have significantly increased rates of revision, periprosthetic fracture, and dislocation compared to dTHA and primary THA.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 23 - 23
1 Nov 2022
Jha A Jayaram J Carter J Siney P James J Hemmady M
Full Access

Abstract. Cemented total hip arthroplasty (THA) in the younger patient has historically been associated with higher wear and revision rates. We carried out a retrospective study of a prospectively collected database of patients at Wrightington hospital undergoing cemented THA under 55 years of age to determine acetabular wear and revision rates. Between August 2005 and December 2021 a cohort of 110 patients, 56 males and 54 females, underwent Cemented Total Hip Replacement through a posterior approach. Mean age at operation was 50yrs (35–55). The mean follow up was 6 years 9 months (0–16 years). 3 patients were lost to follow-up. Of the remaining 107 patients, Conventional and cross lined polyethylene were used in 54 and 53 patients respectively. Ceramic heads were used in 102 patients. 22.225mm and 28mm heads were used in 60 and 47 patients respectively. Clinical outcomes were assessed by Merle d'Aubigne and Postel scores which showed significant functional improvement. Linear wear was measured on plain radiographs using TRAUMA CAD and cup loosening was assessed by classification of Hodgkinson et al. No cases were revised during the observed follow up period. The mean wear rate in conventional and crosslinked polyethylene cups were 2.31mm (0.1–4.6) and 1.02mm (0.1–2.6) respectively. Cemented THA with both conventional and crosslinked polyethylene provides excellent survival rates in adults under the age of 55 years and crosslinked polyethylene may further improve these results due to improved wear rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 103 - 103
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Patients who are Jehovah's witnesses do not accept blood transfusions. Thus, total hip arthroplasty can be challenging in this group of patients due to the potential for blood loss. Multiple strategies have been developed in order to prevent blood loss. A 76-year-old female, Jehovah's witness medicated with a platelet antiaggregant, presented to the emergency department after a fall from standing height. Clinically, she had pain mobilizing the right lower limb and radiological examination revealed an acetabular fracture with femoral head protrusion and ipsilateral isquiopubic fracture. Skeletal traction was applied to the femur during three weeks and no weight bearing was maintained during the following weeks. Posteriorly, there was an evolution to hip osteoarthritis with necrosis of the femoral head. The patient was submitted to surgery six months after the initial trauma, for a total hip arthroplasty. The surgery was performed with hypotensive anaesthesia, careful surgical technique and meticulous haemostasis and there was no need for blood transfusion. Posteriorly, there was a positive clinical evolution with progressive improvement on function and deambulation. Total hip arthroplasty may be safely carried out with good clinical outcomes in Jehovah's witnesses, without the need for blood transfusion, if proper perioperative precautions are taken, as has already been shown in previous studies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 7 - 7
10 Feb 2023
Brennan A Doran C Cashman J
Full Access

As Total Hip Replacement (THR) rates increase healthcare providers have sought to reduce costs, while at the same time improving patient safety and satisfaction. Up to 50% of patients may be appropriate for Day Case THR, and in appropriately selected patients’ studies show no increase in complication rate while affording a significant cost saving and maintaining a high rate of patient satisfaction. Despite the potential benefits, levels of adoption of Day Case THR vary. A common cause for this is the perception that doing so would require the adoption of new surgical techniques, implants, or theatre equipment. We report on a Day-Case THR pathway in centres with an established and well-functioning Enhanced Recovery pathway, utilising the posterior approach and standard implants and positioning. We prospectively collected the data on consecutive THRs performed by a single surgeon between June 2018 and July 2021. A standardised anaesthetic regimen using short acting spinal was used. Surgical data included approach, implants, operative time, and estimated blood loss. Outcome data included time of discharge from hospital, post operative complications, readmissions, and unscheduled health service attendance. Data was gathered on 120 consecutive DCTHRs in 114 patients. 93% of patients were successfully discharged on the day of surgery. Four patients required re-admission: one infection treated with DAIR, one dislocation, one wound ooze admitted for a day of monitoring, one gastric ulcer. One patient had a short ED attendance for hypertension. Our incidence of infection, dislocation and wound problems were similar to those seen in inpatient THR. Out data show that the widely used posterior approach using standard positioning and implants can be used effectively in a Day Case THR pathway, with no increase in failure of same-day discharge or re-admission to hospital


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 19 - 19
1 Jul 2020
Innmann M Reichel F Schaper B Merle C Beaulé P Grammatopoulos G
Full Access

Aims. Our study aimed to 1) Describe the changes in spinopelvic mobility when transitioning from standing, to ‘relaxed-seated’ and thereafter to ‘deep-seated’ position and 2) Determine the change in spinopelvic mobility types 1 year post-THA compared to preoperatively. Methods. This prospective diagnostic cohort study followed 100 consecutive patients 1 year post-THA. Preoperatively and one year postoperatively, radiographic measurements were performed for the lumbar-lordosis-angle, pelvic tilt and pelvic-femoral-angle on lateral radiographs in the standing, ‘relaxed-seated’ and ‘deep-seated’ position (torso maximally leaning forward). Patients were classified according to their spinopelvic mobility type, according to the change in PT between the standing and relaxed-seated position (stiff:ΔPT<±10°, normal:10°≤ΔPT≤30°, hypermobile:ΔPT>±30°). Results. Compared to preoperatively, when moving from a standing to a relaxed-seated position, hip flexion increased by 10°±18, leading to less posterior pelvic tilt by 6°±11 and reduced lumbar spine flexion by 6°±11 (all p<0.001). Similarly, when moving from the standing to deep-seated position, hip flexion improved by a mean of 8°±22, leading to reduced lumbar spine flexion by a mean of 5°±8, whereas the change in pelvic tilt did not change compared to preoperatively (p=0.016, p<0.001, p=0.46). The distribution of spinopelvic mobility types 1 year postoperatively was significantly different compared to preoperatively, as the percentage of patients with stiff spinopelvic mobility increased from 16% to 43% (p<0.001). Conclusion. Hip flexion improved by 10° on average 1 year after total hip arthroplasty. Thus, slightly less compensatory posterior pelvic tilt and lumbar spine flexion was needed when taking a relaxed-seated position. When taking a deep-seated position, improved hip flexion required less lumbar spine flexion. However, these changes were small when being compared to preoperative variability of these parameters. Thus, individual spinopelvic mobility remains relatively unchanged 1 year after THA compared to preoperatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 6 - 6
13 Mar 2023
Pawloy K Sargeant H Smith K Rankin I Talukdar P Hancock S Munro C
Full Access

Our unit historically performed total hip replacement (THR) through either posterior or anterolateral approaches. In November 2020 a group of 5 consultants transitioned to utilising the Direct Anterior Approach (DAA). Appropriate training was undertaken and cases were performed as dual consultant procedures with intraoperative radiography or robotic assistance. Outcomes were collated prospectively. These included basic demographics, intraoperative details, complication rates and Oxford Hip Scores. A total of 48 patients underwent DAA THR over 1 year. Mean age was 67 and ASA 2. Over this time period 140 posterior approach and 137 anterolateral approach THR's were performed with available data. Propensity score matching was performed on a 1:1 basis using BMI, Age, Sex and ASA as covariates to generate a matched cohort group of conventional approach THR (n=37). Length of stay was significantly reduced at 1.95 days (p<0.001) with DAA compared to Anterolateral and Posterior approach. There was no significant difference with length of surgery, blood loss, Infection, dislocation and periprosthetic fracture rate. There was no significant difference in Oxford Hip Score between any approach at 3 months or 1 year. The transition to this approach has not made a negative impact despite its associated steep learning curve, and has improved efficiency in elective surgery. From our experience we would suggest those changing to this approach receive appropriate training in a high-volume centre, and perform cases as dual consultant procedures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 51 - 51
23 Jun 2023
Adeyemo EA Riepen DW Collett GA Au BK Huo MH
Full Access

The current evidence favors replacement for the treatment of displaced femoral neck fractures in the older patients. Controversies remain whether total hip replacement (THR), or hemiarthroplasty (HA) would result in better outcomes. The purpose of this study is to compare the outcomes, and the complications in patients who underwent THR or HA for displaced femoral neck fractures. There were 345 consecutive patients who had undergone either a THR or HA at a single institution. THR was done in 137, and HA was done in 208 patients, respectively. Standard peri-operative data were collected. The mean values for the data in the THR group are: age 69 years, ASA 2.7, OR time was 99 minutes, estimated blood loss 354 ml, and the length of stay 8 days. The mean values for the data in the HA group are: age 75 years, ASA 3.0, OR time 88 minutes, estimated blood loss 200 ml, and the length of stay 10 days. The overall complications were 8.8% (THR), and 9.1% (HA), respectively. The mortality rates for the patients were: at the 1-year (9.5% THR vs 16.3% HA), at the 3-year (15.3% THR vs 24.0% HA), and at the 5-year (19.7% THR vs 26.9% HA), respectively. Our data demonstrated similar peri-operative data and short-term complications between the two groups. There was a difference in the mortality rates between the two groups at all 3-time intervals following the surgery. This could be a reflection of the patient selection bias for each of the operations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 69 - 69
4 Apr 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters D Williams S
Full Access

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. Although DM THRs have shown good overall survivorship and low dislocation rates, the mechanisms which describe how these bearings function in-vivo are not fully understood. Therefore, the study aim was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment methods. Retrieved DM liners (n=18) were visually inspected for the presence of surface damage, whereby the internal and external surfaces were independently assigned a score of one (present) or zero (not present) for seven damage modes. The severity of damage was not assessed. The material composition of embedded debris was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation [1]. Scratching and pitting were the most common damage modes on either surface. Additionally, burnishing was observed on 50% of the internal surfaces and embedded debris was identified on 67% of the external surfaces. EDX analysis of the debris identified several materials including titanium, cobalt-chrome, iron, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners. The incidence of burnishing was three times greater for the internal surfaces, suggesting that this acts as the primary articulation site. The external surfaces sustained more observable damage as evidenced by a higher incidence of embedded debris, abrasion, delamination, and deformation. In conjunction with the highly variable damage patterns observed, these results suggest that DM kinematics are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 9 - 9
10 May 2024
Owen D
Full Access

Background. Increasing evidence suggests a link between the bearing surface used in total hip arthroplasty (THA) and the occurrence of infection. It is postulated that polyethylene has immunomodulatory effects and may influence bacterial function and survival, thereby impacting the development of periprosthetic joint infection (PJI). This study aimed to investigate the association between polyethylene type and revision surgery for PJI in THA using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). We hypothesized that the use of XLPE would demonstrate a statistically significant reduction in revision rates due to PJI compared to N-XLPE. Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) spanning September 1, 1999, to December 31, 2021, were used to compare the infection revision rates between THA using N-XLPE and XLPE. We calculated the Cumulative Percentage Revision rate (CPR) and Hazard Ratio (HR) while controlling for factors like age, sex, body mass index (BMI), American Society of Anesthesiologists’ (ASA) grade, and head size. Results. From the total 361,083 primary THAs, 26,827 used N-XLPE and 334,256 used XLPE. Excluding data from the first 6 months post-surgery, 220 revisions occurred in the N-XLPE group and 1,055 in the XLPE group for PJI. The HR for infection revision was significantly higher in N-XLPE compared to XLPE, at 1.64 (95% CI, 1.41–1.90, p<0.001). Conclusions. This analysis provides evidence of an association between N-XLPE and revision for infection in THA. We suspect that polyethylene wear particles contribute to the susceptibility of THA to PJI, resulting in a significantly higher risk of revision for infection in N-XLPE hips compared to those with XLPE. Level of Evidence. Therapeutic Level III


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 38 - 38
23 Jun 2023
Karachalios T Varitimidis S Komnos G Koutalos A Malizos KN
Full Access

Local anatomical abnormalities vary in congenital hip disease patients. Authors often present early to mid-term total hip arthroplasty clinical outcomes using different techniques and implants randomly on patients with different types of the disease, making same conclusions difficult. We report long term outcomes (13 to 23 years) of the treatment of low and high dislocation cases (separately) with total hip arthroplasty using TM technology acetabular cups (Implex initially and then Zimmer) and short fluted conical (Zimmer) femoral stems. From 2000 to 2010, 418 congenital hip disease hip joints were treated in our department with total hip arthroplasty. According to Hartofilakidis et al's classification, 230 hips had dysplasia, 101 low dislocation, (group A) and 87 high dislocation (group B). Pre-operative and post-operative values, at regular intervals, of HHS, SF-12, WOMAC, OHS and HOOS were available for all patients. Patient, surgeon and implant related failures and complications were recorded for all patients. In all cases an attempt was made to restore hip center of rotation. In group A the average lengthening was 2.8 cm (range: 1 to 4.2) and in group B 5.7 cm (range: 4.2 to 11). In both groups, no hips were revised due to aseptic loosening of either the acetabular cup or the femoral stem. In group A, a cumulative success rate of 95.6% (95% confidence interval, 92.7% – 97.4%) and in group B a cumulative success rate of 94.8% (95% confidence interval, 92.6%–96.9%) was recorded, at 20 years, with revision for any reason as an end point. No s.s. differences were found between groups when mean values of HHS, SF-12, WOMAC and OKS were compared. Satisfactory long-term clinical outcomes can be achieved in treating different types of congenital hip disease when appropriate surgical techniques combined with “game changing” implants are used


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 17 - 17
1 Jun 2023
Hoellwarth J Oomatia A Al Muderis M
Full Access

Introduction. Transfemoral osseointegration (TFOI) for amputees has substantial literature proving superior quality of life and mobility versus a socketed prosthesis. Some amputees have hip arthritis that would be relieved by a total hip replacement (THR). No other group has reported performing a THR in association with TFOI (THR+TFOI). We report the outcomes of eight patients who had THR+TFOI, followed for an average 5.2 years. Materials & Methods. Our osseointegration registry was retrospectively reviewed to identify all patients who had TFOI and also had THR, performed at least two years prior. Six patients had TFOI then THR, one simultaneous, one THR then TFOI. All constructs were in continuity from hip to prosthetic limb. Outcomes were: complications prompting surgical intervention, and changes in subjective hip pain, K-level, daily prosthesis wear hours, Questionnaire for Persons with a Transfemoral Amputation (QTFA), and Short Form 36 (SF36). All patients had clinical follow-up, but one patient did not have complete mobility and quality of life survey data at both time periods. Results. Four (50%) were male, average age 52.7±14.8 years. Three patients (38%) had amputation for trauma, three for osteosarcoma, one each (13%) infected total knee and persistent infection after deformity surgery. One patient died one year after THR+TOFA from subsequently diagnosed pancreatic cancer. One patient had superficial debridement for infection with implant retention after five years. No implants were removed, no fractures occurred. All patients reported severe hip pain preoperatively versus full relief of hip pain afterwards. K-level improved from 0/8=0% K>2 (six were wheelchair-bound) to 5/8=63% (p=.026). At least 8 hours of prosthesis wear was reported by 2/7=29% before TOFA vs 5/7=71% after (p=.286). The QTFA improved in all categories, but not significantly: Global (40.0±21.6 vs 60.0±10.9, p=.136), Problem (50.2±33.2 vs 15.4±8.4, p=.079), and Mobility (35.9±26.8 vs 58.3±30.7, p=.150). The SF36 also improved minimally and not significantly: Mental (53.6±12.0 vs 54.7±4.6, p=.849) and Physical (32.5±10.9 vs 36.3±11.2, p=.634). Conclusions. THR+TFOI is a successful reconstruction option for amputees who desire relief from severe pain related to hip joint degeneration, and also the opportunity for improved mobility and quality of life that TFOI typically confers. In our cohort, the procedure proved safe: no associated deaths, no removals, one soft tissue debridement. Mobility improved markedly. Quality of life improved, but not to significant thresholds as measured by the surveys. THR+TFOI appears safe and reasonable to offer to transfemoral amputees with painful hip joint degeneration


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 149 - 149
11 Apr 2023
Gagnier J O'Connor J
Full Access

We sought to determine the relationship between patient preoperative psychological factors and postoperative THA outcomes. We performed an electronic search up to December 2021 using the following terms: “(mental OR psychological OR psychiatric) AND (function OR trait OR state OR predictor OR health) AND (outcome OR success OR recovery OR response) AND total joint arthroplasty)”. Peer-reviewed, English language studies regarding THA outcomes were analyzed for preoperative patient mental health metrics and objective postoperative results regarding pain, functionality and surgical complications. We extracted study data, assessed the risk of bias of included studies, grouped them by outcome measure and performed a GRADE assessment. Seventeen of 702 studies fulfilled inclusion criteria and were included in the review. Overall, compared to cohorts with a normal psychological status, patients with higher objective measures of preoperative depression and anxiety reported increased postoperative pain, decreased functionality and greater complications following THA. Additionally, participants with lower self-efficacy or somatization were found to have worse functional outcomes. Following surgery, both early and late pain scores remained higher in patients with preoperative depression and anxiety. Preoperative depression and anxiety may negatively impact patient reported postoperative pain, physical function and complications following THA. A meta-analysis was not performed because of the heterogeneity of studies, specifically the use of differing pain scales and measures of physical and psychological function as well as varied follow-up times. Future research could test interventions to treat pre-operative depression or anxiety and explore longitudinal outcomes in THA patients. Surgeons should consider the preoperative psychological status when counseling patients regarding expected surgical outcomes and attempt to treat a patient's depression or anxiety prior to undergoing total hip arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 5 - 5
4 Apr 2023
Vicary-Watts R McLauchlan G
Full Access

Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR). This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score. The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one peri-prosthetic fracture. The mean Oxford score pre-arthroplasty was 12.2 (8.4), improving to 38.4 (11.1) at one-year. Although the pre op Oxford scores tended to be lower in patients with undisplaced fractures and higher ASA scores, the improvement was the same whatever the pre-op situation. The one-year Oxford score and the improvement in score are comparable to those seen in the literature for THR in general. In conclusion, CHS has a high success rate and where salvage arthroplasty is required it can provide good clinical outcomes with low complication rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 24 - 24
17 Apr 2023
Cooper N Etchels L Lancaster-Jones O Williams S Wilcox R
Full Access

Non-optimal clinical alignment of components in total hip replacements (THRs) may lead to edge loading of the acetabular cup liner. This has the potential to cause changes to the liner rim not accounted for in standard wear models. A greater understanding of the material behaviours could be beneficial to design and surgical guidance for THR devices. The aim of this research was to combine finite element (FE) modelling and experimental simulation with microstructural assessment to examine material behaviour changes during edge loading. A dynamic deformable FE model, matching the experimental conditions, was created to simulate the stress strain environment within liners. Five liners were tested for 4Mc (million cycles) of standard loading (ISO14242:1) followed by 3Mc of edge loading with dynamic separation (ISO14242:4) in a hip simulator. Microstructural measurements by Raman spectroscopy were taken at unloaded and highly loaded rim locations informed by FE results. Gravimetric and geometric measurements were taken every 1Mc cycles. Under edge loading, peak Mises stress and plastic deformation occur below the surface of the rim during heel strike. After 7Mc, microstructural analysis determined edge loaded regions had an increased crystalline mass fraction compared to unloaded regions (p<0.05). Gravimetric wear rates of 12.5mm. 3. /Mc and 22.3mm. 3. /Mc were measured for standard and edge loading respectively. A liner penetration of 0.37mm was measured after 7Mc. Edge loading led to an increase in gravimetric wear rate indicating a different wear mechanism is occurring. FE and Raman results suggest that changes to material behaviour at the rim could be possible. These methods will now be used to assess more liners and over a larger number of cycles. They have potential to explore the impact of edge loading on different surgical and patient variables


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the long-term outcomes of this bearing surface


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 27 - 27
2 May 2024
Board T Nunley R Mont MA
Full Access

The purpose of this modified Delphi study was to obtain consensus on wound closure (including best practices for each tissue layer of closure) and dressing management in total hip arthroplasty (THA), using an evidence-based approach. The Delphi panel included 20 orthopedic surgeons from Europe and North America. Eighteen statements were identified (14 specific to THA and 4 relating to both THA and total knee arthroplasty) using a targeted literature review. Consensus was developed on the statements with up to three rounds of anonymous voting per topic. Panelists ranked their agreement with each statement on a five-point Likert scale. An a priori threshold of 75% was required for consensus. In Round 1, 15 of 18 statements achieved consensus via a structured electronic questionnaire. In Round 2, the 3 statements that did not achieve consensus were revised during a virtual face to face meeting. An additional 2 statements were edited for clarity. In Round 3, the 5 revised statements achieved consensus via a structured electronic questionnaire. Wound closure related interventions that were recommended for use in THA included: 1) barbed sutures over non-barbed sutures (shorter closing times and overall cost savings); 2) subcuticular sutures over skin staples (lower risk of infections and higher patient preference); 3) mesh-adhesives over silver-impregnated dressings (lower rate of wound complications); 4) negative pressure wound therapy over other dressings (lower wound complications and reoperations and fewer dressing changes); 5) triclosan coated sutures (lower risk of surgical site infection). Using a modified Delphi approach, a panel of 20 orthopedic surgeons achieved consensus on 18 statements pertaining to multi-layer wound closure and dressing management in THA. This study forms the basis for identifying critical evidence gaps within wound management to help reduce variability in outcomes during THA