Guidelines published by the British Association of Spine Surgeons (BASS) and Society of British Neurological Surgeons (SBNS) recommend urgent MRI imaging and intervention in individuals suspected of having CES. The need for an evidence based protocol is driven by a lack of 24/7 MRI services and centralisation of neurosurgery to tertiary centres, compounded by CES's significant medico-legal implications. We conducted an audit to evaluate the pathway for suspected CES in BCUHB West between 2018 and 2021.

Methods

A retrospective audit of patients managed for suspected CES between 01/11/2018 and 01/05/2021 was performed, using the SBNS/BASS guidelines as the standard.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 52 - 52
17 Nov 2023
Jones R Bowd J Gilbert S Wilson C Whatling G Jonkers I Holt C Mason D
Full Access

Abstract

OBJECTIVE

Knee varus malalignment increases medial knee compartment loading and is associated with knee osteoarthritis (OA) progression and severity1. Altered biomechanical loading and dysregulation of joint tissue biology drive OA progression, but mechanistic links between these factors are lacking. Subchondral bone structural changes are biomechanically driven, involve bone resorption, immune cell influx, angiogenesis, and sensory nerve invasion, and contribute to joint destruction and pain2. We have investigated mechanisms underlying this involving RANKL and alkaline phosphatase (ALP), which reflect bone resorption and mineralisation respectively3 and the axonal guidance factor Sema3A. Sema3A is osteotropic, expressed by mechanically sensitive osteocytes, and an inhibitor of sensory nerve, blood vessel and immune cell invasion4. Sema3A is also differentially expressed in human OA bone5.HYPOTHESIS: Medial knee compartment overloading in varus knee malalignment patients causes dysregulation of bone derived Sema3A signalling directly linking joint biomechanics to pathology and pain.

METHODS

Synovial fluid obtained from 30 subjects with medial knee OA (KL grade II-IV) undergoing high tibial osteotomy surgery (HTO) was analysed by mesoscale discovery and ELISA analysis for inflammatory, neural and bone turnover markers. 11 of these patients had been previously analysed in a published patient-specific musculoskeletal model6 of gait estimating joint contact location, pressure, forces, and medial-lateral condyle load distribution in a published data set included in analyses. Data analysis was performed using Pearson's correlation matrices and principal component analyses. Principal Components (PCs) with eigenvalues greater than 1 were analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 6 - 6
3 Mar 2023
Ramage G Poacher A Ramsden M Lewis J Robertson A Wilson C
Full Access

Introduction

Virtual fracture clinics (VFC's) aim to reduce the number of outpatient appointments while improving the clinical effectiveness and patients experience through standardisation of treatment pathways. With 4.6% of ED admissions due to trauma the VFC prevents unnecessary face to face appointments providing a cost savings benefit to the NHS.

Methods

This project demonstrates the importance of efficient VFC process in reducing the burden on the fracture clinics. We completed preformed a retrospective cross-sectional study, analysing two cycles in May (n=305) and September (n=332) 2021. We reviewed all VFC referrals during this time assessing the quality of the referral, if they went on to require a face to face follow up and who the referring health care professional was. Following the cycle in May we provided ongoing education to A&E staff before re-auditing in September.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 1 - 1
3 Mar 2023
Kinghorn AF Whatling G Bowd J Wilson C Holt C
Full Access

This study aimed to examine the effect of high tibial osteotomy (HTO) on the ankle and subtalar joints via analysis of static radiographic alignment. We hypothesised that surgical alteration of the alignment of the proximal tibia would result in compensatory distal changes.

35 patients recruited as part of the wider Biomechanics and Bioengineering Centre Versus Arthritis HTO study between 2011 and 2018 had pre- and postoperative full-length weightbearing radiographs taken of their lower limbs. In addition to standard alignment measures of the limb and knee (mechanical tibiofemoral angle, Mikulicz point, medial proximal tibial angle), additional measures were taken of the ankle/subtalar joints (lateral distal tibial angle, ground-talus angle, joint line convergence angle of the ankle) as well as a novel measure of stance width. Results were compared using a paired T-test and Pearson's correlation coefficient.

Following HTO, there was a significant (5.4°) change in subtalar alignment. Ground-talus angle appeared related both to the level of malalignment preoperatively and the magnitude of the alignment change caused by the HTO surgery; suggesting subtalar positioning as a key adaptive mechanism. In addition to compensatory changes within the subtalar joints, the patients on average had a 31% wider stance following HTO. These two mechanisms do not appear to be correlated but the morphology of the tibial plafond may influence which compensatory mechanisms are employed by different subgroups of HTO patients.

These findings are of vital importance in clinical practice both to anticipate potential changes to the ankle and subtalar joints following HTO but it could also open up wider indications for HTO in the treatment of ankle malalignment and osteoarthritis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 68 - 68
1 Dec 2021
Bowd J Williams D de Vecchis M Wilson C Elson D Whatling G Holt C
Full Access

Abstract

Objectives

Principal Component Analysis (PCA) is a useful method for analysing human motion data. The objective of this study was to use PCA to quantify the biggest variance in knee kinematics waveforms between a Non-Pathological (NP) group and individuals awaiting High Tibial Osteotomy (HTO) surgery.

Methods

Thirty knees (29 participants) who were scheduled for HTO surgery were included in this study. Twenty-eight NP volunteers were recruited into the study. Human motion analysis was performed during level gait using a modified Cleveland marker set. Subjects walked at their self-selected speed for a minimum of 6 successful trials. Knee kinematics were calculated within Visual3D (C-Motion). The first three Principal Components (PCs) of each input variable were selected. Single-component reconstruction was performed alongside representative extremes of each PC to aid interpretation of the biomechanical feature reconstructed by each component.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 53 - 53
1 Dec 2021
De Vecchis M Naili JE Wilson C Whatling GM Holt CA
Full Access

Abstract

Objectives

Exploring the relationship of gait function pre and post total knee replacement (TKR) in two groups of patients.

Methods

Three-dimensional gait analysis was performed at Cardiff University, UK, and Karolinska University Hospital, Sweden, on 29 and 25 non-pathological (NP) volunteers, and 39 and 28 patients with end-stage knee osteoarthritis (OA), respectively. Patients were assessed pre and one-year post-TKR. Data reduction was performed via Principal Component (PC) analysis on twenty-four kinematic and kinetic waveforms in both NP and pre/post-TKR. Cardiff's and Karolinska's cohorts were analysed separately. The Cardiff Classifier, a classification system based on the Dempster-Shafer theory, was trained with the first 3 PCs of each variable for each cohort. The Classifier classifies each participant by assigning them a belief in NP, belief in OA (BOA) and belief in uncertainty, based on their biomechanical features. The correlation between patient's BOA values (range: 0–1, 0 indicates null BOA and 1 high BOA) pre and post-TKR was tested through Spearman's correlation coefficient in each cohort. The related-samples Wilcoxon signed-rank test (α=0.05) determined the significant changes in BOA in each cohort of patients. The Mann-Whitney U test (α=0.05) was run to explore differences between the patients’ cohorts.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 20 - 20
1 Aug 2021
Palmer J Fraig H Wilson C Garrett S
Full Access

Noise induced hearing loss (NIHL) is a common cause of preventable deafness in adults and exposure to loud noise at work is a significant risk factor for its development. In order to protect the hearing of workers in the U.K., the Health and Safety Executive (HSE), on behalf of the Department for Work and Pensions, established the Control of Noise at Work Regulations (2005). The objectives of this study were to define the levels of noise exposure for the surgeon, assistant, scrub nurse and anaesthetist during total hip and knee arthroplasty surgery. In addition, we sought to determine whether the noise exposure during these procedures reaches or exceeds the action values set out by the U.K. Noise at Work Regulations (2005). To our knowledge no real-time assessment of personal noise exposure has been performed simultaneously on multiple members of the theatre team during arthroplasty surgery.

Individual noise exposure during arthroplasty hip and knee surgery was recorded using a personal noise dosemeter system model 22 (DM22) (Pulsar instruments, Filey, U.K.). Recordings were taken real-time during five separate theatre sessions. Each theatre session included two arthroplasty procedures and lasted approximately 4hrs. Personal noise exposure was expressed in terms of peak sound pressure and an average noise exposure over an 8-hour time-period to reflect the noise experienced by the ear over a working day.

In all three sessions involving total hip replacement surgery the peak sound pressure, for the operating surgeon, exceeded the exposure action values set out by the U.K. Noise at Work Regulations. Theatre sessions involving total knee replacement surgery did not exceed any exposure action values.

The peak sound pressures experienced during total hip replacement surgery are too high and mandate that the surgeon should be provided with appropriate hearing protection. In addition, if the upper exposure action value is routinely exceeded then the theatre should be designated a hearing protection zone.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 30 - 30
1 Mar 2021
De Vecchis M Biggs PR Wilson C Whatling GM Holt CA
Full Access

Abstract

Objectives

Exploring the association of objective lower limb function pre and post total knee replacement (TKR).

Methods

3D gait analysis was performed on 28 non-pathological participants (NP) and 40 patients with advanced knee osteoarthritis (OA) before and approximately one year after TKR. For NP and OA patients pre/post-TKR, 12 waveforms on kinetic and kinematic variables of the operative side were chosen to perform data reduction through Principal Component (PC) Analysis. The Cardiff Classifier, a classification system based on Dempster-Shafer theory, was trained with the first 3 PCs of each variable. The 18 highest-ranking PCs classifying the biomechanical features of each participant as Belief in Healthy, Belief in OA (BOA) or Belief in Uncertainty were used to quantify biomechanical changes pre- to post-TKR. The correlation between patients’ BOA values (range: 0 to 1, 0 indicates null BOA and 1 high BOA) pre- and post-TKR was tested through Spearman's correlation coefficient. Wilcoxon matched-pair test (α<0.05) determined the significance of the change in BOA.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 58 - 58
1 Mar 2021
Kinghorn A Bowd J Whatling G Wilson C Mason D Holt C
Full Access

Abstract

OBJECTIVES

Valgus high tibial osteotomy (HTO) represents an effective treatment for patients with medial compartment osteoarthritis (OA) in a varus knee. However, the mechanisms which cause this clinical improvement are unclear. Previous studies suggest a wider stance gait can reduce medial compartment loading via reduction in the external knee adduction moment (KAM); a measure implicated in progression of medial compartment OA. This study aimed to measure whether valgus HTO is associated with a postoperative increase in static stance width.

METHODS

32 patients, recruited in the Biomechanics and Bioengineering Centre Versus Arthritis HTO study, underwent valgus (medial opening wedge) HTO. Weightbearing pre- and post- operative radiographs were taken showing both lower limbs. The horizontal distance, measured from a fixed point on the right talus to the corresponding point on the left, was divided by the talus width to give a standardised “stance width” for each radiograph. The difference between pre- and post- operative stance width was compared for each patient using a paired sample t-test.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 59 - 59
1 Mar 2021
Bowd J van Rossom S Wilson C Elson D Jonkers I Whatling G Holt C
Full Access

Abstract

Objective

Explore whether high tibial osteotomy (HTO) changes knee contact forces and to explore the relationship between the external knee adduction moment (EKAM) pre and 12 months post HTO.

Methods

Three-dimensional gait analysis was performed on 17 patients pre and 12-months post HTO using a modified Cleveland marker-set. Tibiofemoral contact forces were calculated in SIMM. The scaled musculoskeletal model integrated an extended knee model allowing for 6 degrees of freedom in the tibiofemoral and patellofemoral joint. Joint angles were calculated using inverse kinematics then muscle and contact forces and secondary knee kinematics were estimated using the COMAC algorithm. Paired samples t-test were performed using SPSS version 25 (SPSS Inc., USA). Testing for normality was undertaken with Shapiro-Wilk. Pearson correlations established the relationships between EKAM1 to medial KCF1, and EKAM2 to medial KCF2, pre and post HTO.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 58 - 58
1 Feb 2021
Sires J Wilson C
Full Access

Robotic-assisted technology in total knee arthroplasty (TKA) aims to increase implantation accuracy, with real-time data being used to estimate intraoperative component alignment. Postoperatively, Perth computed tomography (CT) protocol is a valid measurement technique in determining both femoral and tibial component alignments. The aim of this study was to evaluate the accuracy of intraoperative component alignment by robotic-assisted TKA through CT validation. A total of 33 patients underwent TKA using the MAKO robotic-assisted TKA system. Intraoperative measurements of both femoral and tibial component placements, as well as limb alignment as determined by the MAKO software were recorded. Independent postoperative Perth CT protocol was obtained (n.29) and compared with intraoperative values. Mean absolute difference between intraoperative and postoperative measurements for the femoral component were 1.17 degrees (1.10) in the coronal plane, 1.79 degrees (1.12) in the sagittal plane, and 1.90 degrees (1.88) in the transverse plane. Mean absolute difference between intraoperative and postoperative measurements for the tibial component were 1.03 degrees (0.76) in the coronal plane and 1.78 degrees (1.20) in the sagittal plane. Mean absolute difference of limb alignment was 1.29 degrees (1.25), with 93.10% of measurements within 3 degrees of postoperative CT measurements. Overall, intraoperatively measured component alignment as estimated by the MAKO robotic-assisted TKA system is comparable to CT-based measurements.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 33 - 33
1 Jul 2020
Palmer J Wilson C Wilson D Garrett S
Full Access

Background

Orthopaedic surgeons are exposed to high levels of noise when performing common surgical procedures. Noise induced hearing loss (NIHL) has been demonstrated amongst senior orthopaedic staff. The objective of this study was to investigate the prevalence of hearing loss amongst arthroplasty surgeons compared to non-surgical clinicians and explore the factors associated with hearing loss.

Methods

A cross-sectional prevalence study. Arthroplasty surgeons and non-surgical clinicians were recruited from orthopaedic and medical conferences.

All participants were given a paper questionnaire including demographic details, hearing history and Tinnitus and Hearing Survey (THS). All participants were screened for hearing loss in a quiet room using the HearCheck Screener™ (Siemens, UK).

Logistic regression was used to identify factors associated with hearing loss. All statistical models were adjusted for age, gender, smoking status and personal noise exposure. A power calculation estimated a sample size of 100 participants.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 160 - 166
22 May 2020
Mathai NJ Venkatesan AS Key T Wilson C Mohanty K

Aims

COVID-19 has changed the practice of orthopaedics across the globe. The medical workforce has dealt with this outbreak with varying strategies and adaptations, which are relevant to its field and to the region. As one of the ‘hotspots’ in the UK , the surgical branch of trauma and orthopaedics need strategies to adapt to the ever-changing landscape of COVID-19.

Methods

Adapting to the crisis locally involved five operational elements: 1) triaging and workflow of orthopaedic patients; 2) operation theatre feasibility and functioning; 3) conservation of human resources and management of workforce in the department; 4) speciality training and progression; and 5) developing an exit strategy to resume elective work. Two hospitals under our trust were redesignated based on the treatment of COVID-19 patients. Registrar/consultant led telehealth reviews were carried out for early postoperative patients. Workflows for the management of outpatient care and inpatient care were created. We looked into the development of a dedicated operating space to perform the emergency orthopaedic surgeries without symptoms of COVID-19. Between March 23 and April 23, 2020, we have surgically treated 133 patients across both our hospitals in our trust. This mainly included hip fractures and fractures/infection affecting the hand.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 6 - 6
1 Apr 2019
Wilson C Singh V
Full Access

Introduction

The intra-operative diagnosis of Prosthetic Joint Infection (PJI) is a dilemma requiring intra-operative sampling of suspicious tissues for frozen section, deep tissue culture and histopathology to secure a diagnosis. Alfa defensin-1 testing has been introduced as a quick and reliable test for confirming or ruling out PJI. This study aims to assess its intra-operative reliability compared to the standard tests.

Methods

Twenty patients who underwent revision hip and knee arthroplasty surgery were included. Patients joint aspirate was tested intra-operatively with the Synovasure kit, which takes approximately ten minutes for a result. Our standard protocol of collecting 5 deep tissue samples for culture and one sample for histopathology was followed. Results for Alfa defensin-1 test were then compared with final culture and histopathology results in all these patients.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 4 - 4
1 Apr 2019
Wilson C Inglis M George D
Full Access

Introduction

Revision total hip arthroplasty is a complex procedure and becoming more common. Acetabular implant loosening or fracture has previously been treated with a cup and cage construct. Recent studies have shown significant failure rates with Cup Cage constructs in more complex 3B and 3C Acetabular revisions. As a result the use of 3D printed custom made acetabular components has become more common.

Method

We present 5 cases with severe acetabular bone loss that were treated with 3D printed acetabular components. The components were manufactured by OSSIS medical in New Zealand. The patient's original femoral stem was retained in all cases. Pre operatively the implant design was approved by the arthroplasty team prior to final manufacture. Implants were provided with a sterilisable model used intraoperatively for reference.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 5 - 5
1 Apr 2019
Wilson C Sires J Lennon S Inglis M
Full Access

Introduction

Despite improvement in implants and surgical techniques up to 20% of Total Knee Arthroplasty TKA patients continue to report dissatisfaction. The ATTUNE Knee System was designed to provide better patellar tracking and stability through the mid-range of flexion and therefore improve patient outcomes and satisfaction.

Aims

The aims of this study were to assess patient outcomes in a consecutive series of ATTUNE TKA and ensure early results were comparable to other TKA systems in Australia.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims

The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration.

Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA.

Method

A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented.

A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 20 - 20
1 Jan 2019
Khatib N Wilson C Mason DJ Holt CA
Full Access

Focal cartilage defects (FCDs) found in medial and lateral compartments of the knee are accompanied with patient-reported pain and loss of joint function. There is a deficit of evidence to explain why they occur. We hypothesise that aberrant knee joint loading may be partially responsible for FCD pathology, therefore this study aims to use 3-dimensional motion capture (MoCap) analysis methods to investigate differences in gait biomechanics of subjects with symptomatic FCDs.

11 subjects with Outerbridge grade II FCDs of the tibiofemoral joint (5 medial compartment, 6 lateral compartment) and 10 non-pathological controls underwent level-gait MoCap analysis using an infra-red camera (Qualisys) and force-plate (Bertec) passive marker system. 6-degree of freedom models were generated and used to calculate spatio-temporal measures, and frontal and sagittal plane knee, hip and ankle rotation and moment waveforms (Visual 3D). Principle component analysis (PCA) was used to score subjects based on common waveform features, and PC scores were tested for differences using Mann-Whitney tests (SPSS).

No group differences were found in BMI, age or spatio-temporal measures. Medial-knee FCD subjects experienced higher (p=0.05) overall knee adduction moments (KAMs) compared to controls. Conversely, lateral-knee FCD subjects found lower (p=0.031) overall KAMs. Knee flexion and extension moments (KFMs/KEMs) were relatively reduced (p=0.013), but only in medial FCD subjects. This was accompanied by a significantly (p=0.019) higher knee flexion angle (KFA) during late-stance.

KAMs have been shown to be predictive of frontal plane joint contact forces, and therefore our results may be reflective of FCD subjects overloading their respective diseased knee condyles. The differences in knee sagittal plane knee moments (KFMs/KEMs) and angles (KFA) seen in medial FCD subjects are suggestive of gait adaptations to pain. Overall these results suggest treatments of FCDs should consider offloading the respective affected condyle for better surgical outcomes.


Total knee arthroplasty is associated with early postoperative pain. Appropriate pain management is important to facilitate postoperative rehabilitation and positive functional outcomes. This study compares outcomes in TKA with three techniques; local infiltration analgesia, single shot femoral nerve block and intrathecal morphine.

Methods

Forty-five patients undergoing elective primary Total Knee Arthroplasty (TKA) with were randomized into one of three groups in a double blind proof of concept study.

Study arm 1 received local infiltration analgesia ropivacaine intra-operatively, an elastomeric device of ropivacaine for 24 hours post-op.

Study arm 2 received a femoral nerve block of ropivacaine with placebo local infiltration analgesia and placebo intrathecal morphine.

Study arm 3 received intrathecal morphine, placebo femoral nerve block and placebo local infiltration analgesia. All patients received standardized pre-operative, intraoperative and Post-operative analgesic medication.

Participants were mobilized at 4 hrs, 24hrs and 48 hrs post operation. Range of Motion, Visual Analogue Scale (VAS) pain intensity scores and two minute walk test and Timed Up and Go test were performed. Postoperative use of analgesic drugs was recorded. Knee Society Score (KSS), Oxford Knee Score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed at preoperative and 6 weeks post op.

Results

Preliminary results of 32 participants convey the positive outcomes after total knee replacement demonstrated by the improvement in Oxford Knee Score and Knee Osteoarthritis Outcome score. There are marked improvements in the 2-minute walk tests at the six week time-point. At day one post-operative only 5 participants were unable to walk. Patient-controlled analgesia was used on 5 occasions on day one, 2 of which continued on day two. Sedation scores were recorded in six participants on day one and 2 on day two. Nausea was reported in 5 cases on day one and 9 on day two. Urinary catheter was needed in 5 cases on day one.

Importantly the study remains blinded, therefore an analysis of the three study arms is not available and is therefore currently difficult to report on the statistical significance. There will be further assessment of the efficacy of analgesia using VAS pain scores, analgesia consumption and side effects collected preoperatively, 0–24hrs and 24–48 hours postoperatively between the three randomized groups. The assessment of functional outcomes will be measured between the three groups by comparing the ability to mobilize the first 4 hrs after surgery, maximal flexion and extension, two minute walk test and timed up-and-go preoperatively, on postoperative day 1 and 2 and 6 weeks.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 132 - 132
1 May 2016
Wilson C
Full Access

Introduction

Patients undergoing total knee arthroplasty have expected blood loss during and after surgery. The current literature remains inconclusive in regards to which surgical instrumentation techniques in total knee arthroplasty are effective in minimising peri-operative blood loss. The primary objective of this retrospective review of a prospective randomized cohort study is to compare surgical and patient factors and their influence on blood loss and transfusions rates between one type of Patient Specific Instrumentation (PSI) (SignatureTM), Navigated Computer-Assisted Surgery (CAS) and Conventional Total Knee Arthroplasty (TKA) surgical techniques.

Method

128 matched patients (38 SignatureTM, 44 CAS, 46 Conventional surgeries) were compared. Pre-operative factors were analysed including; age, gender, Body Mass Index (BMI), pre-operative hemoglobin (g/L), International Normalized Ratio (INR), use of anticoagulants and co-morbid bleeding diathesis. Maximal hemoglobin drop were compared on Day 1 to 3, as well as, transfusion requirement. Peri-operative factors were collected including; surgical time, tourniquet time, drain output, insitu drain time, order of tibia or femoral cut and intra-operative loss from suction.