In the UK we have many surgeon inventors – surgeons who innovate and create new ways of doing things, who invent operations, who design new instruments to facilitate surgery or design new implants for using in patients. However truly successful surgeon inventors are a rare breed and they need to develop additional knowledge and skills during their career in order to push forward their devices and innovations. This article reviews my own experiences as a surgeon inventor and the highs and lows over the whole of my surgical career.
However the complication rates have been noticeably higher for the Inverse shoulder arthroplasties with 2/44 (5%) not being completed at surgery and 5/44 (11%) requiring surgical revision subsequently. This experience mirrors that of other publications which will be summarised.
Data were collected on patients undergoing subacromial decompression (SAD) in our routine practice from 1998 to 2004. All patients had clinical signs of subacromial pain and had failed conservative treatment. Tears were not repaired. Data on age, gender, arm dominance and presence of cuff tear at operation were recorded. At six months post-operatively, patients were assessed with the Constant Score (CS). Data were analysed using multiple linear regression. Data on 427 patients were collected, 168 having rotator cuff tears. The mean age was 55.41 years (SD 12.00). There were 233 women and 191 men. There were no significant gender differences between the two groups (x2=2.34, df=1, p=0.13). The group with cuff tears were significantly older by 10.24 years (p<
0.001, 8.10 to 12.38). Power of the study was 90% at the 5% significance level. Multiple linear regression showed that gender, age and presence of a cuff tear all had a significant effect on the CS. Gender B = 5.52 (1.99 to 9.06) p = 0.002 Age B = −0.31 (−0.48 to −0.15) p <
0.001 Cuff tear B = −5.51 (−9.48 to −1.55) p = 0.007 Hand dominance and the side operated upon had no significant effect. We found that in patients with symptomatic shoulders, who had failed conservative treatment and undergone an SAD, the CS at six months follow up was lower in those who had a cuff tear. There was increased tear prevalence in slightly older patients, and these scored on average 5.5 (1.5 to 9.5) points less than expected on the CS, p = 0.007, after allowing for age and gender. We believe that the surgeon should discuss with the patient whether a 5.5 points lower score is enough of a difference to warrant a formal rotator cuff repair rather than debridement and SAD alone, and a joint decision should be made.
The NHS Plan (2000) identified the need for change in the way patients are asked to give consent for surgery to make the process more explicit. A new NHS operation consent form was introduced in April 2002 following the Bristol enquiry into deaths associated with Cardiac Surgery.
Shoulder – Arthroscopic Sub-Acromial Decompression, Anterior stabilisation, Rotator Cuff repair, excision lateral end of clavicle and Shoulder Arthroplasty. Elbow – Tennis elbow release, Arthroscopic Debridement, OK Operation and Elbow Replacement We became increasingly aware throughout this exercise that although there were many papers published; collating the relevant evidence based information for patients was either difficult or impossible. Evidence was therefore been categorised into 4 levels:
National &
International published results Our own results, either published or presented at scientific meetings Our own results as identified in internal audited outcome studies – unpublished Our opinion of the risks or benefits unsupported by any scientific or published evidence.
We report the results of a method of reconstructing massive rotator cuff (RC) tears and reinforcing the repaired RC tendons with re-tensioning of the cuff to effect reconstruction of tears which were previously considered non-repairable.
This study investigates the survival (with gross radiological loosening) rates of prostheses following uncemented Total Shoulder Arthroplasties (TSAs) focusing on the glenoid baseplate fixation. All uncemented TSAs inserted in one shoulder unit from 1989 to 2001 were entered onto a database prospectively and the patients monitored to death or failure of the implant, resulting in revision surgery. Over 80% of the surviving implants were monitored on sequential radiographs and the radiological loosening rate was observed. 273 TSAs have been monitored – 193 with a porous coated glenoid baseplate and 80 with a hydroxyapatite coating on top of the porous coating. The Survival rates (%) of the non-HA coated base-plates at 1 to 12 years using the Life Table Method were:- 97, 93, 89, 83, 83, 81, 79, 79, 77, 75, 75 &
75% respectively. The Survival rates for the HA coated glenoid baseplates at 1 to 4 years were 100, 97, 93, &
93% respectively. Failures were predominantly due to mechanical loosening and glenoid disassembly with only 3 cases of infection documented. Thus by 4 years there was a statistically significant improvement in survival of the glenoids. Survival rates were further reduced when radiological loosening was taken into account. The earlier series was analysed to assess the survival of prostheses inserted for RA and OA. The survival rates at 5 &
10 years were 78% &
70% for OA and 96% &
88% for RA. This Life Table analysis confirms the early benefit from the use of hydroxyapatite coating of the glenoid implant of a TSA. Further improvements, particularly in relation to reducing further the small risk of disassembly are underway.
The ACL-deficient knee demonstrates an increase in both tibial rotation and translation that can lead to progressive degeneration within the knee joint. Functional Knee Braces (FKBs) have often been prescribed as an integral part of treatment programmes for such patients. However, the ability of a FKB to increase the stability of the ACL-deficient knee by controlling tibial translation has yet to be confirmed. In addition the athlete with ACL deficiency frequently asks if he/she can use a treadmill as a safe indoor exercise tool. A prospective study was carried out on 15 pre-operative ACL-deficient patients and 15 fully matched subjects as controls. A gait analysis study was designed using the CODA ACL-deficient subjects had significantly lower speed, shorter stride length and consequently longer double support time while walking on level ground (p<
0.05). None of these variables changed following bracing. The ACL-deficient subjects showed more knee flexion at heel strike and mid-stance which was assumed to be a compensatory reaction to the ligament deficient knee. The FKB significantly reduced ROM in the ACL-deficient subjects at all gait activity levels (p<
0.05). It also reduced peak knee flexion during swing while walking on level ground, but increased maximum knee flexion in swing while walking on the treadmill. Walking on the treadmill reduced hip ROM but running on the treadmill increased ankle ROM in both groups of subjects. No significant angulatory kinematic changes were found during running on the treadmill either before or after bracing. The ACL-deficient subjects showed more knee rotation than the controls during all the trials. Neither the quadriceps nor hamstring muscles showed significant differences between the ACL-deficient and control subjects. The gastrocnemius muscle however was found to have a principal role in the ACL-deficient subjects. FKBs caused the gastrocnemius to be activated earlier (P=0.0001) and showed a positive effect during low force activities. As treadmill walking or running was always accompanied by an increased ankle plantar flexion, it always decreased the gastrocnemius onset activation time that may be a compensatory reaction to stabilise the injured knee. No significant differences were found between the ACL-deficient and the control subjects in terms of kinematics or EMG findings during running on the treadmill. We have identified beneficial biomechanical changes following the use of FKBs on ACL-deficient knees but only during walking trials. The brace was as effective for walking on the treadmill as walking on the ground. The FKBs led the deficient knees into a safer kinematics and EMG pattern. The ACL-deficient subjects ran as normally as the control subjects and no effects of the FKBs were found during running in our studies.
The aimof this study was to assess proprioception in multi-directional instability of the shoulder before and after a new surgical treatment. A cross-sectional pilot study assessing shoulder proprioception in asymptomatic controls (n=6), pre-operative patients (n=7) awaiting surgery for atraumatic, multidirectional instability having failed a comprehensive rehabilitation programme and post-operative patients (n=7) having undergone thermo-capsular shrinkage of the shoulder and post-operative rehabilitation. Data were obtained using the Proprioception Assessment System developed at this centre following a standardised protocol to record both threshold to detection of passive movement (TTDPM) and reproduction of passive position (RPP) in three positions of rotation. Means and standard deviations are presented. There were no differences between shoulders in controls and post-operative patients. Despite the small numbers, pre-operative patients showed significant differences (p<
0.05) between shoulders in 2 of the 6 test protocols. Post-operative shoulders had means similar to controls suggesting thermo-capsular shrinkage may help regain shoulder proprioception after injury.