header advert
Results 1 - 20 of 33
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 84 - 84
1 Jan 2018
Lerch T Steppacher S Ziebarth K Tannast M Siebenrock K
Full Access

Posterior extraarticular ischiofemoral hip impingement can be caused by high femoral torsion and is typically located between the ischium and the lesser trochanter. We asked if patients undergoing derotational femoral osteotomies for posterior FAI have (1) decreased hip pain and improved function and evaluated (2) subsequent surgeries and complications?

Thirty-three hips undergoing derotational femoral osteotomies between 2005 and 2016 were evaluated retrospectively. Of them 15 hips underwent derotational femoral osteotomies and 18 hips underwent derotational femoral osteotomies combined with varisation (neck-shaft angle >139°). Indication for derotational osteotomies was a positive posterior impingement test in extension and external rotation, high femoral torsion (48° ± 9) on CT scans and limited external rotation. Offset improvement was performed to avoid intraarticular impingement in hips with a cam-type FAI. All patients were female and mean followup was 3 ± 2 (1 – 11) years.

At latest followup the positive posterior and anterior impingement test decreased from preoperatively 100% to 5% (p< 0.001) and from preoperatively 85% to 30% (p< 0.001). The mean Merle d'Aubigné Postel score increased from 14 ± 1 (11 – 16) to 16 ± 1 (13 – 17) at latest followup (p< 0.001). At followup 32/33 hips had been preserved and one hip had been converted to a total hip arthroplasty (THA). In two hips (6%) revision osteosynthesis was performed for delayed healing of the femoral osteotomy.

Derotational femoral osteotomies for the treatment of posterior extraarticular ischiofemoral impingement caused by high femoral torsion result in decreased hip pain and improved function at midterm followup but had 6% delayed healing rate requiring revision surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 128 - 128
1 Mar 2017
Zurmuehle C Anwander H Albers CE Steppacher S Siebenrock K Tannast M
Full Access

Introduction

Acetabular retroversion is an accepted cause of Pincer-type femoroacetabular impingement. There is increasing evidence that acetabular retroversion is rather a rotational abnormality of the pelvis than an overgrowth of the acetabular wall or even a dysplasia of the posterior wall. Initially, patients with a retroverted acetabulum were treated with an open rim trimming through a surgical hip dislocation (SHD) based on the early understanding of the pathomorphology. Theoretically, the reduction of the anterior wall can decrease the already small joint contact area in retroverted hips to a critical size. Based on the most recent literature, anteverting periacetabular osteotomy (PAO) seems to be the more appropriate surgical treatment. With this technique, the anterior impingement conflict can be treated efficiently without compromising the joint contact area. However, it is unknown whether this theoretical advantage in turn results in better mid term results of treatment.

Objectives

We asked if anteverting PAO results in better clinical and radiographical mid term results compared to rim trimming through a surgical hip dislocation.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 139 - 139
1 Mar 2017
Lerch T Todorski I Steppacher S Schmaranzer F Siebenrock K Tannast M
Full Access

Introduction

Torsional deformities are increasingly recognized as an additional factor in young patients with hip pain resulting from pincer- and cam-deformities. For example decreased femoral torsion can worsen an anterior Femoroacetabular impingement (FAI) conflict while an increased torsion can be beneficial with the same configuration.

It is unknown how often torsional deformities are present in young patients presenting with hip pain that are eligible for joint preserving surgery. We questioned (1) what is the prevalence of a pathological femoral torsion in hips with FAI or hip dysplasia? (2) which hip disorders are associated with an abnormal torsion?

Methods

An IRB-approved retrospective study of 463 consecutive symptomatic FAI patients (538 hips) and a MRI or CT scan on which femoral torsion could be measured was performed (‘study group'). Out of 915 MRI we excluded 377 hips.

The study group was divided into 11 groups: Dysplasia (< 22° LCE), retroversion, anteverted hips, overcoverage (LCE angle 36–39°), severe overcoverage (LCE>39°), cam (>50° alpha angle), mixed FAI, varus- (<125° CCD angle), valgus- (>139° CCD), Perthes-hips and hips with no obvious pathology.

The ‘control group' of normal hips consisted of 35 patients (35 hips) without radiographic signs of osteoarthritis or hip pain wich was used for a previous study.

Femoral antetorsion was measured according to Tönnis et al. as the angle between the axis of the femoral neck and the posterior axis of the femoral condyles. Normal femoral torsion was defined by Tönnis et al. as angles 10–25° while decreased resp. increased torsion was defined as <5° and >25°.

Statistical analysis was performed using analysis of variances (ANOVA).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 17 - 17
1 Mar 2017
Steppacher S Milosevic M Lerch T Tannast M Ziebarth K Siebenrock K
Full Access

Introduction

Hips following in-situ pinning for slipped capital femoral epiphysis (SCFE) have an altered morphology of the proximal femur with cam type deformity. This deformity can result in femoroacetabular impingement and early joint degeneration. The modified Dunn procedure allows to reorientate the slipped epiphysis to restore hip morphology and function.

Objectives

To evaluate (1) hip pain and function, (2) 10-year survival rate and (3) subsequent surgeries and complications in hips undergoing modified Dunn procedure for SCFE.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 127 - 127
1 Mar 2017
Zurmuehle C Steppacher S Beck M Siebenrock K Zheng G Tannast M
Full Access

Introduction

The limited field of view with less-invasive hip approaches for total hip arthroplasty can make a reliable cup positioning more challenging. The aim of this study was to evaluate the accuracy of cup placement between the traditional transgluteal approach and the anterior approach in a routine setting.

Objectives

We asked if the (1) accuracy, (2) precision, and (3) number of outliers of the prosthetic cup orientation differed between three study groups: the anterior approach in supine position, the anterior approach in lateral decubitus position, and the transgluteal approach in lateral decubitus position.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 16 - 16
1 Mar 2017
Steppacher S Zurmuehle C Christen M Tannast M Zheng G Christen B
Full Access

Introduction

Navigation in total hip arthroplasty (THA) has the goal to improve accuracy of cup orientation. Measurement of cup orientation on conventional pelvic radiographs is susceptible to error due to pelvic malpositioning during acquisition. A recently developed and validated software using a postoperative radiograph in combination with statistical shape modelling allows calculation of exact 3-dimensional cup orientation independent of pelvic malpositioning.

Objectives

We asked (1) what is the accuracy of computer-navigated cup orientation (inclination and anteversion) and (2) what is the percentage of outliers (>10° difference to aimed inclination and anteversion) using postoperative measurement of 3-dimensional cup orientation.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 122 - 122
1 Feb 2017
Lerch T Tannast M Steppacher S Siebenrock K
Full Access

Introduction

Since its first description in 1988, periacetabular osteotomy has become the gold-standard worldwide in surgical treatment of developmental dysplasia of the hip. Several long-term studies have proven the efficacy of this procedure. In this study, we evaluated the mean 30-years results of this procedure of the first 63 patients (75 hips) operated at the institution where this procedure had been developed.

Objectives

We determined the (1) cumulative 30-year survivorship of symptomatic patients treated with this procedure, determined the (2) clinical and (3) radiographic outcomes of the surviving hips, and (4) identified factors predicting the need for total hip arthroplasty (THA).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 17 - 17
1 Feb 2017
Anwander H Hanke M Steppacher S Werlen S Siebenrock K Tannast M
Full Access

Introduction

Magnetic resonance imaging with intraarticular contrast (arthro-MRI) and radial cuts is the gold standard to quantify labral and chondral lesions in the setting of femoroacetabular impingement. To date, no study exists that has evaluated these findings as potential predictors of outcome for the long term follow-up after surgical treatment of FAI.

Objectives

The purpose of this study was to detect potential predictors for failure after surgical hip dislocation for FAI based on specific preoperative arthro-MRI of the hip at a minimum follow-up of 10 years.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 18 - 18
1 Feb 2017
Anwander H Siebenrock K Tannast M Steppacher S
Full Access

Introduction & Objective

Labral refixation has established as a standard in open or arthroscopic treatment for femoroacetabular impingement (FAI). The rationale for this refixation is to maintain the important suction seal in the hip. To date, only few short-term results are available which indicate a superior result in FAI hips with labral refixation compared to labral resection. Scientific evidence of a beneficial effect of labral refixation in the long-term follow-up is lacking.

Aim of this study was to evaluate if labral refixation can improve the cumulative 10-year survivorship in hips undergoing surgical hip dislocation for FAI compared to labral resection.

Methods

We performed a retrospective comparative study of 59 patients treated with surgical hip dislocation for symptomatic FAI between December 1998 and January 2003. We analyzed two matched groups: The ‘resection’ group consisted of 25 hips that were treated consistently by excision of the damaged labrum. The ‘refixation’ group consisted of 34 hips that were treated with labral reattachment. Correction of the osseous deformity (rim trimming/femoral osteochondroplasty) did not differ between the two groups. We then evaluated the clinical (Merle d'Aubigné score) and radiographical results (according to Tönnis) at a follow-up of ten years.

We calculated a cumulative Kaplan-Meier survivorship curve with the following factors as endpoints: conversion to total hip arthroplasty (THA), radiographic evidence of osteoarthritis progression, or a poor clinical result (defined as Merle d'Aubigné score of less than 15). The two curves were compared using the Log-rank test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 121 - 121
1 Feb 2017
Lerch T Tannast M Steppacher S Siebenrock K
Full Access

Introduction

Torsional deformities of the femur have been recognized as a cause of femoroacetabular impingement (FAI) and hip pain. High femoral antetorsion can result in decreased external rotation and a posterior FAI, which is typically located extraarticular between the ischium and trochanter minor. Femoral osteotomies allow to correct torsional deformities to eliminate FAI. So far the mid-term clinical and radiographic results in patients undergoing femoral osteotomies for correction of torsional deformities have not been investigated.

Objectives

Therefore, we asked if patients undergoing femoral osteotomies for torsional deformities of the femur have (1) decreased hip pain and improved function and (2) subsequent surgeries and complications?


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 41 - 41
1 Aug 2013
Ecker T Steppacher S Haimerl M Murphy S
Full Access

Introduction

Correct postoperative leg length restoration is among the most important goals of hip arthroplasty. Therefore, we developed, validated and clinically applied a novel software algorithm based on surgical navigation, which allows the surgeon to restore a defined femur position without establishing a femoral coordinate system or the hip joint center and measure the leg length accurately and simply.

Material and Methods

This new leg length algorithm was used in 154 hips (145 patients) that underwent CT-based computer-assisted THA (VectorVision Build 274 prototype; BrainLAB AG, Helmstetten, Germany) with a tissue preserving superior capsulotomy. Intraoperatively, a pelvic and a femoral dynamic reference bases (DRB) were applied and the anterior pelvic plane (APP) was set as the pelvic coordinate system. Then, the hip joint was put in a neutral position and this position, and the relative position of the femoral DRB relative to the pelvic DRB, was captured and stored by the navigation system. After implantation of the prosthesis the same above described femoral position with the same amplitude of flexion/extension, abduction/adduction and rotation was restored. Now, any resulting difference was due to linear changes. Validation of this new algorithm was performed by comparing the navigated results to measurements from calibrated antero-posterior pre- and postoperative radiographs. The radiographic results were compared to the mean leg length change measured with the navigation system.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 273 - 273
1 Mar 2013
Steppacher S Tannast M Murphy S
Full Access

Young patients have been reported to have a higher risk of revision following total hip arthroplasty than older cohorts. This was attributed to the higher activity level which led to increased wear, osteolysis, and component fracture. We prospectively assessed the clinical results, wear and osteolysis, the incidence of squeaking, and the survivorship of ceramic on ceramic THA in patients younger than 50 years (mean age of 42 [18–50] years). The series included 425 THAs in 370 patients with 368 hips followed for a minimum of 2 years (mean 7.1 years, range 2–14 years). All patients received uncemented acetabular components with flush-mounted acetabular liners using an 18 degree taper. No osteolysis was observed in any uncemented construct. There was osteolysis around one loose cemented femoral component. The survivorship for reoperation for implant revision was 96.7%. There were only two acetabular liner fractures (0.47%) and one femoral head fracture (0.24%). Two of the three fractures involved a fall from a significant height. There were no hip dislocations. Five patients (1.17%) noted rare or occasional squeaking. None had reproducible squeaking. In summary, the current study shows that ceramic-on-ceramic THAs in the young patient population are extremely reliable with a very low revision rate and an absence of wear-induced osteolysis. In addition, it shows that both bearing fracture in this young patient population typically occurs with polytrauma and squeaking issues that have been raised relative to ceramic bearings occur very rarely with the flush-mounted ceramic liner design used in this study.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 272 - 272
1 Mar 2013
Murphy W Steppacher S Kowal JH Murphy S
Full Access

Introduction

Half of all acetabular components placed using conventional methods are malpositioned1. The HipSextant™ Navigation System (Surgical Planning Associates, Boston, MA) is a mechanical navigation system, adjusted on a patient-specific basis, designed to achieve appropriate cup alignment as simply and rapidly as possible. The current study assesses the surgeon's ability to register and track the pelvis and align the cup using the system.

Methods

A bioskills model pelvis (Pacific Research Laboratories, Inc., Vashon, WA) was prepared by placing screws to mark the anterior pelvic plane points and by inserting a long cup alignment pin, simulating a cup insertion handle, into the acetabulum. The bone model was then scanned using CT. The HipSextantTM Navigation System Planning Application was then used to plan the use of the HipSextant for the surgery. This is accomplished by creating a 3D model, designating the AP plane (marked by the screws), and then determining the HipSextant docking points. One of these three points is behind the posterior wall of the acetabulum (the basepoint). The second of these three points is on the lateral aspect of the anterior superior iliac spine. The third point, the landing point, is located on the surface of the ilium and equally distant from the other two points (Figure 1). The two protractors on the HipSextant planning application were then adjusted to be parallel with the cup alignment pin on the bone model.

A surgeon and assistant were then asked to dock the HipSextant on the bone model and to visually align the direction indicator to be parallel with the cup alignment pin. The two protractor angles on the instrument were recorded. This allowed for calculation of error in operative anteversion and operative inclination between the plan and the actual alignment that was accomplished. Four pairs of surgeon and assistant each performed the docking and alignment procedure 10 times for a total of 40 measurements.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 221 - 221
1 Sep 2012
Steppacher S Albers C Tannast M Siebenrock K Ganz R
Full Access

Traumatic hip dislocation is a rare injury in orthopaedic practice and typically occures in high energy trauma. The goal of this study was to analyze hip morphology in patients with low energy traumatic hip dislocations and to compare it with a control group.

We performed a retrospective comparative study. The study group included 45 patients with 45 traumatic posterior hip dislocation. Inclusion criteria were traumatic hip dislocation with simple acetabular rim or Pipkin I or II fracture. Traumatic dislocations combined with other acetabular or femoral fractures were excluded. The control group consisted of 90 patients (180 hips) that underwent radiographic examination for urogenital indication and had no history of hip pain. Hip morphology was assessed on antero-posterior and axial views.

The study group showed significantly increased incidence (p<0.001) of positive cross-over sign (82% vs. 27%) with a increased retroversion index (26 ± 17 [0–56] vs. 6 ± 12 [0–53]), positive ischial spine sign (70% vs. 34%), and positive posterior wall sign (79% vs. 21).

Hips that underwent an low energy posterior traumatic hip dislocation show significanly more radiographic signs for acetabular retroversion compared to a control group. Therefore, acetabular retroversion seems to be a contributing factor for posterior traumatic hip dislocation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 585 - 585
1 Sep 2012
Albers C Steppacher S Ganz R Siebenrock K Tannast M
Full Access

The Bernese Periacetabular Osteotomy (PAO) has become the established method for treating developmental dysplasia of the hip. In the 1990s, the surgical technique was modified to avoid postoperative cam impingement due to uncorrected head neck offset or pincer impingement due to acetabular retroversion after reorientation. The goal of the study was to compare the survivorship of two series of PAOs with and without the modifications of the surgical technique and to calculate predictive factors for a poor outcome.

A retrospective, comparative study of two consecutive series of PAOs with a minimum follow-up of 10 years was carried out. Series A included 75 PAOs performed between 1984 and 1987 and represent the first cases of PAO. Series B included 90 hips that underwent PAO between 1997 and 2000. In this series, emphasis was put on an optimal acetabular version next to the correction of the lateral coverage. Additionally, a concomitant arthrotomy was performed in every hip to check impingement-free range of motion after reorientation and in 50 hips (56%) an additional offset correction was performed. Survivorship analyses according to Kaplan and Meier were carried out and the endpoint was defined as conversion to a total hip arthroplasty, progression of osteoarthritis, or a Merle d'Aubign score 14. Predictive factors for poor outcome were calculated using the Cox-regression analysis.

The cumulative 10-year survivorship of Series A was significantly decreased (77%; 95%-confidence interval [CI] 72–82%) compared to Series B (86%; 95%-CI 82–89%, p=0.005). Hips with an aspherical head showed a significantly increased survivorship if a concomitant offset correction was performed intraoperatively (90% [95%-CI 86–94%] versus 77% [95%-CI 71–82%], p=0.003). Preoperative factors predicting poor outcome included a high age at surgery, a Merle d'Aubign score 14, a positive impingement test, a positive Trendelenburg sign, limp, an increased grade of osteoarthritis according to Tönnis, and (sub-) luxation of the femoral head (Severin > 3). In addition, predictive factors related to the three dimensional orientation of the acetabular fragment were identified. These included total, anterior, and posterior acetabular over-coverage or under-coverage, acetabular retroversion or excessive anteversion, a lateral center edge angle < 22 °, an acetabular index > 14 °, and no offset correction in aspherical femoral heads.

A good long term result after PAO mainly depends on optimal three-dimensional orientation of the acetabulum and impingement-free range of motion with correction of an aspherical head neck junction if necessary.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 426 - 426
1 Sep 2012
Keck J Kienle K Siebenrock K Steppacher S Werlen S Mamisch TC
Full Access

Purpose

The purpose of this retrospective study was to investigate the acetabular morphology of pincer impingement hips in order to better understand damage pattern in these patients. We compared MRI measurements made at different postions from anterior to posterior on the acetbulum in patients with pure pincer type FAI to those made in patients with pure cam-type to collect parameters that may be useful in the diagnosis and classification of pincer impingement.

Material and Methods

From an initial consecutive retrospective population of 1022 patients that underwent MRI with clinical impingement signs 78 hips which were selected with as clear cam (n=57) or pincer (n=21) impingement on plain radiographics. On these MR Imaging was performed with a 1.5-Tesla system. For analysis, a lateral angle of overcoverage on coronal MRI (MR_LCE), the MR extrusion index and the alpha angle (after Nötzli) were used. In addition to these the gamma angle, the acetabular depth and the angle of lateral acetabular overcoverage were described clock-wise on 7 radial slides from anterior to posterior. These were compared between the cam and pincer population using students-t-test. Measurements were obtained by two observers and inter-observer variability was assessed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 468 - 468
1 Sep 2012
Steppacher S Albers C Tannast M Siebenrock K
Full Access

Femoroacetabular impingement (FAI) is a pathologic condition of the hip that leads to osteoarthrosis. The goal of the surgical hip dislocation is to correct the bony malformations to prevent the progression of osteoarthrosis. We investigated the topographical cartilage thickness variation in patients with FAI and early stage osteoarthrosis using an ultrasonic probe during surgical hip dislocation.

We performed a prospective case-series of 38 patients (41 hips) that underwent surgical hip dislocation. The mean age at operation was 30.6 (range, 18–48) years. Indication for surgery was symptomatic FAI with 4 hips (10%) with pincer-type, 7 hips (17%) with cam-type, and 20 hips (73%) with mixed-type of FAI. Cartilage thickness was measured intraoperatively using an A-mode 22 MHz ultrasonic probe at 8 locations on the acetabular cartilage.

The thickest acetabular cartilage was found in the weight bearing zone (range 2.8–3.5mm), whereas the thinnest cartilage was in the posterior acetabular horn (1.0–2.2 mm). In all hips, cartilage was thicker in the periphery area compared to the central area. In the anterior and posterior acetabular horn, the anterior area, and the superior area (central parts) a significantly decreased cartilage thickness in pincer-type compared to cam-type of FAI was found (p<0.05).

Cartilage thickness shows topographical differences in all types of FAI with pincer-type of FAI having generally thinner cartilage than cam-type FAI. This is the first study measuring in vivo cartilage thickness in the human hip.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 163 - 163
1 Jun 2012
Steppacher S Kowal JH Murphy S
Full Access

Acetabular component malpositioning is the most common reason for instability and wear resulting in revision total hip arthroplasty (THA). The current study aimed to assess a novel mechanical navigation device which was designed to simply and efficiently indicate appropriate cup orientation during surgery. The accuracy was compared to a series of hip arthroplasties performed using CT-based computer-assisted cup placement.

The study group consisted of 70 THAs performed using the mechanical device. The control group consisted of 146 THAs performed using CT-based computer navigation. Postoperative cup positioning was measured using a validated 2D/3D-matching method. An outlier was defined outside a range of ± 10 degrees from the planned inclination or anteversion.

In the study group the mean accuracy for inclination was 1.3 ± 3.4 (-6.6 – 8.2) and 1.0 ± 4.1 (-8.8 – 9.5) for anteversion with no outliers for either parameter. In the control group the accuracy for anteversion (3.0 ± 5.8 [-11.8 - 19.6]; p=0.6%) and the percentage of outliers (6.8%; p=3.3%) differed significantly. The accuracy for inclination (3.5 ± 4.1 [-12.7 - 9.5]; p=21.4%) and the percentage of ouliers (4.8%; p=9.9%) did not differ significantly.

The use of this mechanical navigation device can result in similar accuracy of acetabular cup orientation compared with CT-based surgical navigation. All cups were placed within a zone of ± 10 degree range of inclination and anteversion. This mechanical navigation device allows accurate cup navigation with minimal additional time and equipment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 164 - 164
1 Jun 2012
Steppacher S Tannast M Murphy S
Full Access

Introduction

The use of less invasive techniques for total hip arthroplasty (THA) has remained controversial with some studies showing a higher incidence of complications. The technique of performing total hip arthroplasty through a superior capsulotomy was developed to maximally preserve the soft tissue envelope surrounding the hip. The current study assesses the recovery and complications of hips replaced using conventional and tissue preserving techniques.

Methods

206 hips in 191 patients with a mean follow-up of 4.3 ± 1.0 (range, 3.2 – 5.9) years underwent total hip arthroplasty using the superior capsulotomy technique. The mean age at operation was 55.7 ± 12.9 (19 – 85) years and the operation was performed for 106 hips (51%) in men. The surgical technique involves exposing the superior hip joint capsule posterior to the medius and minimus, and anterior to the short external rotators. The femur is prepared with the femoral head in place and then the femoral head is excised without dislocation. These 206 hips were compared to a cohort of 279 hips replaced using the transgluteal exposure (control group). These 2 series were controlled for complexity and demographic factors. Recovery was evaluated using the Merle d'Aubigné score at 6 and 12 weeks postoperatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 165 - 165
1 Jun 2012
Steppacher S Tannast M Murphy S
Full Access

Total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH) has been associated with increased rates of complications and revision. Hip instability and wear-induced osteolysis are among the more common and serious of these problems. The current investigation prospectively assessed the survivorship and clinical results of patients with DDH treated by alumina ceramic-ceramic THA.

We investigated 161 consecutive hips in 145 patients with DDH classified as Crowe type I (131 hips, 81%), II (26 hips, 16%), III (2 hips, 1%), and IV (2 hips, 1%). All patients had an uncemented titanium acetabular component with a flush mounted alumina ceramic-ceramic bearing. The mean age at operation was 48.0 ± 12.2 years (range, 18 – 79 years). The preoperative Merle d'Aubigné score was 11.4 ± 1.7 (6 – 15). 27 hips (17%) had at least one previous surgical procedure. 92 hips (57%) were replaced with the use of surgical navigation for acetabular component positioning. The mean cup diameter was 49.9 ± 3.4 mm (46 – 60 mm). 88 (55%) bearings were 28mm and 73 (45%) bearings were 32mm.

At a mean follow-up of 6.1 ± 2.5 years (2 – 11.3 years), the mean Merle d'Aubigné score was 17.4 ± 0.9 (14 – 18). There were no cases of osteolysis or dislocation. There was one reoperation of an early displaced cup. In addition, there was one calcar crack that was cerclaged, one intraoperative trochanteric fracture also repaired at surgery. No patient complained of squeaking. 94 patients with 100 hips (61%) completed a questionnaire specifically asking for squeaking. None of these patients reported squeaking. The 10-year Kaplan Meier survivorship of the implants (revision of any component for any reason) was 99.4% (95% confidence interval 98.2-100%).

Results of ceramic-ceramic THA in young patients with low to middle graded DDH after two to eleven years follow-up are promising with no radiographic signs of osteolysis or dislocation.