Recently in Europe, Unicompartmental Knee Arthroplasty (UKA) has regained interest in the orthopedic community; however, based on various reports, results concerning UKA for isolated lateral compartment arthritis seemed to be not as good as for medial side. In 1988 our department started using Unicondylar Knee Pros-thesis with a fixed all polyethylene bearing tibial component and resurfacing of the distal femoral condyle. The aim of this study is to report on our personal experience using this type of implant for lateral osteoarthritis with a long follow-up period. Between January 1988 and October 2003, we performed 54 lateral UKAs (52 patients) and all were implanted for lateral osteoarthritis (3 cases of which were posttraumatic). 52 knees in 50 patients were available after a minimum duration of follow-up of five years (96.3 %). The mean age of the patients at the time of the index procedure was 72.2±1.5 years. The mean duration of follow-up was 100.9 months (range 64 – 189 months). At follow up, 4 underwent a second surgery: one conversion to TKA for tibial tray loosening at 2 years and 3 revisions for UKA in the medial compartment. No revision surgery was necessary for wear of either of the two components, nor for infection. The mean IKS knee score was 94.9 points, with mean range of motion 132.6° (range, 115–150) and a mean IKS function score totaling 81.8 points. The average femorotibial alignment was 1.8° (range −6° to 12°). Radiolucent lines in relation to the tibial component were appreciated in 6 knees and to the femoral component in 1 knee. Implant survival was 98.08% at ten years. The UKA with a fixed bearing tibial component and a femoral resurfacing implant is a reliable option for management of isolated lateral knee osteoarthritis. It offers excellent medium-term results for both functional level and implant survival which even currently enable us to widen our selection criteria to include younger patients or those associated with starting patellofemoral osteoarthritis.
clinical outcome, ligamentous stability and alignment after application of the various medial release techniques (capsular release and deep MCL, pie crust of superficial MCL, superficial MCL release on the tibial side, release of semimembranosus tendon) and to propose a rationale for their use.
In 255 of the 359 (71%) primary TKA’s, symmetrical gaps could be achieved by releasing the capsula and the deep MCL (group 0). In 87 cases (24%), an additional piecrust of the superficial MCL was necessary (group 1). In 55 cases out of these 87 an additional release of the insertion of the semimembranosus was performed. In 17 out of the 359 (5%), the medial tightness necessitated a distal release of the superficial MCL (group 2).
The mean preoperative mechanical femorotibial angle (MFTA) was 174.0, 172.1 and 169.5 and was corrected postoperatively to 179.1, 179.2 and 177.6 for group 0, 1 and 2 respectively. At 12 months, mediolateral stability was clinically evaluated as normal in 97% for group 0, 95% for group 1 and 83% for group 2. Three percent (3%), 5% and 17% has a mediolateral laxity ranging from 6–9 degrees for group 0,1 and 2, respectively.
This study presents the results of 1188 original and innovative posteriorly stabilized TKA procedures in which the femoral bone stock is preserved with a shallow compartment insofar as possible. The TKA procedure is directly derived from Insall’s original technique, except for the posterior stabilisation design, where a third median condyle starts working at 30° of knee flexion. A total of 1188 primary TKA procedures were consecutively performed in a university hospital. Average follow-up was 30 months (0–168 months). The implants were cemented (except for 35 femoral components) and the patella resurfaced (except for nine cases). Clinical results were assessed using the IKS Score. The quality of the implantation was analysed on long-leg X-rays (1175 preoperative and 883 postoperative long-leg films available at follow-up). The results showed that 95% of patients were very satisfied or at least satisfied. Knee score and functional scores were 44 and 54 preoperatively and 90 and 78 postoperatively. Mean range of motion was 116°. On X-ray analysis, the average mechanical femorotibial angle was 179° postoperatively. Survival of the implant for revision was 94.2% at 14 years. We performed 83 re-operations (nine patellar fractures, 14 infections, 12 cases of stiffness and 11 clunck syndromes), including 33 component revisions. Clinical results compared favourably with the literature. This original posterior stabilisation design confirmed the good and excellent results at follow-up. We obtain good range of motion, and no revision was due to polyethylene wear.
Nineteen patients aged 16–50 years with a single osteochondral lesion or osteochondritis dessicans involving the femoral condyle but who had no other knee anomaly were included in this trial. The graft was inserted via an arthrotomy. Patients were examined preoperatively then at 3, 6, 12 and 24 months after grafting. The main evaluation criteria was improvement in the IDCD score (ICRS item) at 24 months. Secondary evaluation criteria were MRI and arthroscopic aspect associated with biopsy of the repaired tissue performed at 24 months.