header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 17 - 17
1 Mar 2021
Mouton C Magosch A Nührenbörger C Seil R
Full Access

Recent findings have identified the importance of previously undiagnosed or neglected meniscus lesions in association with anterior cruciate ligament (ACL) injuries (e.g. medial meniscus ramp lesions and posterior root tears of the lateral meniscus). There is increasing biomechanical evidence that they bear the potential to alter both anteroposterior and rotational laxity patterns in ACL injured knees. Few data exist with respect to the presence of these specific tear entities in large series of ACL injured patients. The purpose of the study was to analyze the meniscus tear pattern in a series of ACL injured knees with a special focus on ramp lesions of the medial meniscus and posterior root lesions of the lateral meniscus. The hypothesis was that a significant number of ACL injured patients would display these types of lesions.

Data from 358 patients undergoing an ACL reconstruction (227 males /131 females, age: 28±10) were extracted from a center-based registry. The type of ACL tear (partial versus complete) as well as the presence of associated meniscus lesions were documented. Meniscus lesions were classified into the following categories: medial ramp lesions, lateral root lesions, medial ramp and lateral root lesion, other medial meniscus injuries, other lateral meniscus injuries, other bimeniscal injuries. Chi-square tests were used to determine whether the percentage of meniscal lesions differed between types of ACL tear, gender and age (below 21, 21–35, above 35). Significance was set at p < 0.05.

Isolated ACL tears were present in 107 (30%) of the operated knees (31 partial; 327 complete). Complete ACL lesions were more likely to present an associated meniscus injury (321 out of 327, 71%) than partial tears (13 out of 31, 42%).

The incidence of meniscus injuries which are associated with ACL tears is very high (70%). Previously undiagnosed or neglected meniscus injuries like medial ramp or lateral root tears could be identified in 35% of patients. As such, the hypothesis was confirmed that an important amount of ACL injured knees display this specific intraarticular soft tissue damage. A systematic evaluation of these lesions under arthroscopy should thus be performed and specific repair needs to be evaluated.


Bone & Joint Research
Vol. 2, Issue 5 | Pages 79 - 83
1 May 2013
Goffin JM Pankaj P Simpson AHRW Seil R Gerich TG

Objectives

Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA).

Methods

We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 504 - 504
1 Nov 2011
Hulet C Galaud B Servien E Vargas R Beaufils P Lespagnol F Wajsfiz A Charrois O Menetrey J Chambat P Javois C Djian P Seil R
Full Access

Purpose of the study: The purpose of this retrospective multicentric analysis was to study the functional and radiological outcomes at more than 20 years of 89 arthroscopic lateral menisectomy procedures performed on stable knees.

Materialandmethod:The series included 89 arthroscopic lateral meniscectomies performed on knee with intact anterior cruciate ligaments (ACL). Mean follow-up was 22±3 years; 56 male, mean BMI 25±4, mean age at meniscectomy 35 years, mean age at last follow-up 57 years. Most of the injuries were vertical (41%), complex (22%) and radial (20%) lesions. The middle segment was involved in 79%. The meniscectomy removed more than one-third of the meniscus in 67%. All patients were reviewed by an independent operator for subjective assessment KOOS (100% normal) and IKDC, and for objective clinical and radiological measurements (IKDC). P< 0.05 was considered statistically significant. There was no independent control group.

Results: Revisions were performed for 16% of the knees. Intense or moderate activity was maintained by all patients. The subjective IKDC score was 71.1±23, comparable with an age and gender matched population. The mean KOOS score was 82% for pain, 80% for symptoms, 85% for daily activities, 64% for sports, and 69% for quality of life. The rate of of osteoarthritis was 56%, and 44% of patients had a difference between the two knees for osteoarthritis. The incidence of osteoarthritis was 53% and shift to valgus on the arthritic side was significantly associated with osteoarthritis, while the opposite side was well aligned. The knee was pain free in 27% of patients. Significant factors for good prognosis were age less than 38 years at first operation, moderate BMI, and minimal cartilage damage (grade 0 or 1).

Conclusion: After the first postoperative year after arthroscopic lateral meniscectomy on a stable knee, the results remain stable and satisfactory for more than 22 years. Nevertheless, patients aged over 40 with a high BMI and cartilage damage at the time of the first operation have a less encouraging prognosis.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 497 - 497
1 Oct 2010
Lorbach O Brockmeyer M Kohn D Maas S Seil R Wilmes P
Full Access

Purpose: Evaluation of the inter- and intra-observer reliability of a new developed knee laxity measurement device for tibiofemoral rotation.

Methods: 30 healthy subjects (15m, 15w, mean age of 24 years) were examined with the Rotameter knee laxitiy measurement device. The Beigthon score was reported to test the general laxitiy of the subjects.

After fixation of the device on the lower extremity and positioning of the patient in the starting position the device was first externally and then internally rotated at an applied torque of 5,10 and 15 Nm. To decrease the measurement error the procedure was repeated 5 times. Afterwards 5 measurements were performed by a second examiner in the same way to measure the inter-observer reliability. All 30 patients were measured again after a mean of 31 ± 43 days by the same examiners to test the intra-observer reliability. Statistical analysis was performed using the intra class correlation coefficient (ICC). Pearson correlation coefficient were used to compare the measurements of the left and the right knee.

Results: The Beigthon Score showed a mean of 0.8 ± 1.1 (0–4). At an applied torque of 5 Nm the ICC for the intra-observer reliability of was 0.81 for the external rotation and 0.67 for the internal rotation, the ICC for the inter-observer reliability was 0.94 for the external and 0.94 for the internal rotation. At 10 Nm of rotation torque an ICC for the intra-observer reliability of 0.79 was reached for internal and 0.88 for external rotation, the ICC for the inter-observer reliability was 0.97 for internal and 0.95 for external rotation. At the highest applied torque of 15 Nm an ICC for the intra-observer reliability of 0.93 was observed for the external rotation and 0.83 was found for internal rotation. For the inter-tester reliability the ICC was 0.95 for external and 0.98 for internal rotation.

The comparison of the measurements of the left and the right knee showed high Pearson correlation (.90) at all applied torques.

Conclusion: The Rotameter testing device for the measurement of tibiofemoral rotation showed a high inter-observer and intra-observer reliability. It is easy to perform and might be used in a wide field to examine the rotational stability of the knee.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 509 - 509
1 Oct 2010
Wilmes P Kohn D Lorbach O Seil R Weth C
Full Access

Purpose: The objective of this investigation was to evaluate the precision of tibial tunnel drilling for anatomic anchoring of meniscus transplants at the tibial insertion area, using previously obtained percentage references.

Methods: In 20 cadaveric tibial heads, anterior and posterior horn insertions of both the lateral and the medial meniscus were dissected and their circumferences outlined. Standardized photographs of the tibial plateau were obtained. Applying previously obtained percentage values for radiographic determination of the meniscus insertion midpoints, tibial tunnels were drilled with the use of a standard ACL-guide. The positioning of the drilling guide was performed by solely using the midpoints as determined on standard ap and lateral radiographs; during the procedure, no position correction related to the anatomic insertions was made. After tibial tunnel drilling, a second set of standardized photographs of the tibial plateau was obtained. Adobe Photo Shop permitted the superposition of pre- and postoperative images. Coincidence between the anatomic insertion areas and the footprint of the tibial tunnel exit was determined, as well as the distance between the borders of the insertion areas and the tunnel footprint.

Results: For the lateral meniscus, the mean coincidence of insertion area and tunnel footprint was 60.5 ± 34.6 % for the anterior horn insertion and 62.4 ± 32.0 % for the posterior horn insertion. The mean distance between the borders of insertion area and tunnel footprint was 1.7 ± 1.5 mm for the anterior horn insertion and 2.3 ± 1.7 mm for the posterior horn insertion.

For the medial meniscus, the mean coincidence of insertion area and tunnel footprint was 88.4 ± 15.5 % for the anterior horn insertion and 60.3 ± 31.6 % for the posterior horn insertion. The mean distance between the borders of insertion area and tunnel footprint was 0.8 ± 0.8 mm for the anterior horn insertion and 2.1 ± 1.4 mm for the posterior horn insertion.

Conclusions: The use of percentage references for tibial meniscus insertion midpoint determination in combination with a radiographic positioned standard ACL-guide permits a precise drilling of tibial tunnels at the anatomic location of the meniscus insertions.

Clinical relevance: Enhancement of the surgical technique for bone plug fixation of lateral and medial meniscus transplants.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 120 - 120
1 Mar 2009
Wilmes P Seil R Pape D Kohn D
Full Access

Introduction: The purpose of our investigation was to determine if tibial lateral meniscus insertions (anterior and posterior horn) can precisely and reproducibly be determined on preoperative radiographs. Bony landmarks and their topographic relations to the meniscus insertions were described, measured and statistically evaluated. We concentrated on the lateral meniscus because there are many reasons to restrict the indications for meniscus replacement on the lateral compartment.

Methods: We prepared the lateral meniscus insertions in 22 tibial plateaus from 11 body donors. Insertion site outline was performed on anterior and posterior horns with radio opaque 1.6 mm steal balls. Anteroposterior and lateral radiographs were performed. On these radiographs, different landmarks of the tibial head were defined and their distances measured (width, depth, distance from lateral tibia border to meniscus midpoint, distance from lateral tibia border to lateral tibial spine). These measures were statistically evaluated and percent values for meniscus insertion midpoint position were determined.

Results: On anteroposterior radiographs, from lateral to medial, the anterior meniscus midpoint was located on 45.1 % ± 1.3 % of the tibial width, the posterior meniscus midpoint on 49.8 % ± 1.9 % of the tibial width. On lateral radiographs, from anterior to posterior, the anterior meniscus midpoint was located on 41.9 % ± 3.2 % of the tibial depth, the posterior meniscus midpoint on 72.1 % ± 2.3 % of the tibial depth. With linear regression analysis, we could show that the lateral meniscus insertions have constant relations, as well to the dimensions of the tibia plateau as to the lateral tibial spine.

Conclusions: We think that it is possible to determine precisely and reproducibly on preoperative anteroposterior and lateral radiographs the insertions of the lateral meniscus. Our results and the method to determine preoperatively meniscus insertions might bring decisive advantages considering the optimal fixation of meniscus transplants, enhancing biomechanical conditions and possibly improving postoperative results.