We report bone bruises on Anterior Cruciate Ligament (hereinafter referred to as ACL) injury. We also investigated the relationship among the presence or absence of bone bruises, localization, and the presence or absence of meniscal injury according to the period of MRI scan from injury. We underwent the study used a total of 76 knees who underwent ACL reconstruction at our hospital and related hospitals from January 2014 to December 2017. We investigated on MRI images taken after injury. Meniscal injuries were evaluated by intraoperative findings. The average age at injury was 25.8 years old (13–48 years old) in 44 males and 32 females. Bone bruises were found in 54 of 76 knees (71%). Among them, the ratio of non-contact type was much higher in the group with bone bruises than in the contact group (83% in the group with bone bruises, 64% in the group without bone bruises), resulting in a shorter period from injury to MRI (bone bruises group: 12.4 days, non-bone bruises group: 23 days). Looking at the appearance frequency of bone bruises according to the period from injury to MRI imaging, the appearance frequency of bone bruises decreased as the time to imaging became longer (within 2 weeks of injury: 76%, injury from 2 weeks to 1 month: 65%, injury 1–3 months: 53%). With regard to the localization of bone bruises, in the coronal section, both femurs and tibiae frequently had bone bruises on the outside. In the sagittal section, it occurred in front of the femur, in particular. On the tibial side, many cases of bone bruises occurred in the rear. In addition, the association between bone bruises and meniscal injuries were significantly complicated with lateral meniscal injury in the group without femoroconstriction in the group with lateral femoral bone bruises and in the group with posterior tibia bone bruises. There was no significant association between bone bruises and meniscal injury among the other groups. Bone bruises were found in 54 of 76 knees (71%). Regarding the occurrence of many lateral developments, it is thought that the tibia is sub-dislocated anteriorly due to mild flexion, valgus force, and external rotation injury, and injury is caused by axial pressure applied to the outside of the femur and posterior of the tibia It was done. As a result, it was considered that the external meniscal injury was injured. The medial unilateral development of bone contusion was observed in 3 knees on the medial femur and 1 knee on the medial tibia. All internal single-cased cases are contact-type injuries, the result of which may be different in the mechanism of bone contusion development.
The rate of elderly people over 65 year-old increased from 18.5 % in 2004 to 26.0% in 2015 in Japan. Northern part of Japan is a head of the super-aging society, and the rate already reached 30.9% in 2015. Along with aging society, rapid increase of total hip arthroplasties (THA) has been predicted. The aim of this study is to estimate the trend of total hip arthroplasties in our super-aging area in Northern Japan. Trend on number and rate of THA in one of the local area of leading super-aging society were surveyed in the last decade using the database of diagnostic procedure and surgical records from 2004 to 2015. The cause of revision THA was analyzed in 2004–2009 versus in 2010–2015. Spearman's rank-correlation coefficient and student's t-tests were performed using the PASW 18 software (SPSS Institute Inc). Values of p < 0.05 were considered statistically significant.Background
Methods
Large head metal on metal total hip arthroplasty MOM THA have been consistently shown substantial improvement in wear performance compared with metal on polyethylene articulations. Large diameter femoral heads theoretically can reduce dislocation risk by increasing range of motion before impingement, increasing prosthetic jump distance. However, early failure associated with adverse local tissue reactions (ALTRs) to metal debris is an emerging problem after MOM THA. The purpose of this study was to evaluate mid-term results of MOM THA. Twenty-five patients, 28 hips were included in this study. The average age of the patients at the time of surgery was 66.9 years. Three patients were men and 22 were women. MOM THAs were performed using 28 PINNACLE Cup system (DepPuy) (C-STEM: 23, S-ROM: 5) with posterior approach and head size of 36mm. Twenty-five primary THAs due to osteoarthritis in 22 cases and rheumatoid arthritis (RA) in one, and two revisions due to recurrent dislocation THA patients, were performed. The average follow up was 56.7 months. Evaluation items are JOA score, cup anteversion /lateral opening angle, and complications. Indication of the system were applied for patients with high risk of dislocation such as recurrent dislocation in primary and/or THAs, posterior pelvic tilt, elderly, RA and mental disorders.Background
Materials and Methods
A navigation system is useful tool to evaluate the intraoperative knee kinematics. Rheumatoid arthritis (RA) patients often need to have TKA operation, however, there are few TKA kinematics studies comparing RA and Osteoarthritis (OA) patients. The purpose of this study was to evaluate intraoperative TKA kinematics, and to describe the difference of kinematics between RA and OA patients.Background
Objective
Patients undergoing total hip arthroplasty (THA) stand in the danger, a particularly high risk for venous thromboembolism (VTE). Fondaparinux and edoxaban, which inhibit FXa, indirectly and directly, respectively, have been used for prevention of VTE after THA in Japan. The aim of this study was to compare the efficacy of fondaparinux and edoxaban for VTE after elective THA in Japanese patients. We randomly assigned 320 patients underdoing elective cemented THA to receive postoperative 2.5 mg fondaparinux once daily for first postoperative 3 days and 1.5 mg once daily for the subsequent 7 days (FPX group) [1], postoperative 15 mg edoxaban once daily for postoperative 10 days (EDO15mg group), 30 mg edoxaban once daily for postoperative 10 days (EDO30mg group), and 30 mg edoxaban once daily for first postoperative 3 days and 15 mg once daily for the subsequent 7 days (EDOmix group). Deep venous thrombosis (DVT) was diagnosed by ultrasonography at postoperative day 3 and 14. Computed tomography to detect pulmonary thromboembolism was performed to all patients who had proximal DVTs. The χ2 test with Bonferroni correction was used to compare variables of the incidence of DVT between each group. The intention-to-treat analysis was performed for statistical analysis in each group. The EDO30 mg group and EDOmix group were regarded as one group in the assessment at the postoperative day 3, and named as the EDO30mg+mix group.Introduction
Materials and methods
Acetabular reconstruction of extensive bone defect is troublesome in revision total hip arthroplasty (rTHA). Kerboull or Kerboull type reinforcement acetabular device with allobone grafting has been applied since 1996. Clinical results of the procedure were evaluated. One hundred and ninety-two consecutive revision total hip arthroplasties were performed with allograft bone supported by the Kerboull or Kerboull type reinforcement acetabular device from 1996 to 2009. There were 23 men and 169 women. Kerboull plates were applied to 18 patients, and Kerboull type plates to 174. The mean follow up of the whole series was 8 years (4–18years). The superior bone defect was reconstructed principally by a large bulky allo block with plate system. Medial bone defect was reconstructed by adequate bone chips and/or sliced bone plates. After temporally fixation of bulky bone block with two 2.0mm K-wires, it was remodeled by reaming to fit the gap between host bone and plate, followed by fixation to the iliac bone by screws. Finally, residual space of the defect between host bone and the fixed plated was filled up with morselized cancellous bones, bone chips, and/or wedged bony fragments with impaction. This method was sufficiently applicable to AAOS Typeâ�, II, and III bone defects. In case of AAOS Typeâ�£, the procedure was also available after repairing discontinuation between distal and proximal bones by reconstrusion plate or allografting with tibial bone plates or sliced femoral head.Patients
Surgical Technique
Macrophages phagocytes implant wear debris and produce various cytokines to evoke inflammation and periprosthetic osteolysis of aseptic loosening. It had been reported that expression of Toll-like receptor (TLR) 2 and other TLRs increased in periprosthetic tissues of aseptic loosening. Pathogen-associated molecular patterns (PAMPs) and damaged-associated molecular patterns (DAMPs) have been known as ligands of TLRs and considered to be involved in the osteolytic reactions TLR1, TLR2, TLR6, NLRP3, TNF-α and IL-1β of macrophages in aseptic loose periprosthetic tissues were immnohistorically evaluated and compared to osteoarthritic synovium. RAW264.7 cells, macrophagic cell line, were stimulated by titanium particles (Ti) and lipoteichoic acid (LTA)-coated Ti. The celluar reaction associated with TLR2 and NLRP3 and the correlation of them were analyzed at mRNA expression levels with small-interfering RNA of Introduction
Materials and methods
Biologic agents (BIO) drastically changed the rheumatoid arthritis (RA) therapy from starting to use biologics at 2003 in Japan. The rate of orthopaedic surgery, especially total joint arthroplasty (TJA) may reflect trends in disease severity, management and health outcomes. We surveyed the number and rate of orthopaedic surgeries and TJA in RA treatment with BIO in the last decade, so called BIO-era.Objectives
Methods
Although the treatment for infected total hip arthroplasty (THA) has been still controversial, some reports suggested two-stage revision THA seems to be more preferable rather than one-stage revision. The purpose of this study is to estimate the outcome of treatment for infected THA in our institutions. The medical records of patients who have been underwent surgical treatment for infected THA between 2006 and 2012 in two hospitals and followed more than one year after surgery were reviewed. 34 patients and 35 hips were included. Age at surgery, gender, a period until surgical treatment after diagnosis of infection, method of treatment (debridement, one-stage or two-stage revision THA) and the outcome are estimated for each hips. Remission was defined by the absence of local and systemic sign of implant related infection and the normalization of WBC and C-reactive protein value without antibiotics.Background and Purpose
Patients and methods
Accurate soft tissue balancing has been recognized as important as alignment of bony cut in total knee arthroplasty (TKA). In addition, using a tensor for TKA that is designed to facilitate soft tissue balance measurements throughout the range of motion with a reduced patello-femoral (PF) joint and femoral component in place, PF joint condition (everted or reduced) has been proved to have a significant effect for intra-operative soft tissue balance. On the other hand, effect of patellar height on intra-operative soft tissue balance has not been well addressed. Therefore, in the present study, we investigated the effect of patellar height by comparing intra-operative soft tissue balance of patella higher subjects (Insall-Salvati index>1) and patella lower subjects (Insall-Salvati indexâ‰/1). The subjects were 30 consecutive patients (2 men, 28 women), who underwent primary PS TKA (NexGen LPS-flex PS: Zimmer, Warsaw, IN, USA) between May 2003 and December 2006. All cases were osteoarthritis with varus deformity. Preoperative Insall-Salvati index (ISI) was measured and patients were divided into two groups; the patella higher group (ISIï1/4ž1: 18 knees average ISI was 1.12) and the patella lower group (ISIâ‰/1; 12 knees average ISI was 0.94). Component gap and ligament balance (varus angle) were measured using offset-type tensor with 40lb distraction force after osteotomy with the PF joint reduced and femoral trial in place at 0, 10, 45, 90, 135 degrees of knee flexion. Data of two groups were compared using unpaired t test.Introduction
Materials and methods
Total knee arthroplasty (TKA) with a computer-assisted navigation system has been developed to improve the accuracy of the alignment of osteotomies and implantations. One of the most important goals of TKA is to improve the flexion angle. Although accurate soft tissue balancing has been recognized as an essential surgical intervention influencing flexion angle, the direct relationship between post-operative flexion angle and intra-operative soft tissue balance during TKA, has little been clarified. In the present study, therefore, we focused on the relationship between them in cruciate-retaining (CR) TKA with a navigation system. The subjects were 30 consecutive patients (2 men, 28 women), who underwent primary CR TKA (B. Braun Aesculap, e-motion) between May 2006 and December 2009. TKAs were performed using a image-free navigation system (OrthoPilot; B. Braun Aesculap, Tuttlingen, Germany). All cases were osteoarthritis with varus deformity. Average patient age at the time of surgery was 74.0 years (range, 62-86 years). After all bony resections and soft tissue releases were completed appropriately using a navigation system with tibia-first gap technique, a tensor was fixed to the proximal tibia and the femoral trial was fitted. Using the tensor that is designed to facilitate soft tissue balance measurements throughout the range of motion with a reduced patello-femoral (PF) joint and femoral component in place, the joint component gap and ligament balance (varus angle) were measured after the PF joint reduced and femoral component in place (Fig.1). Assessments of joint component gap and ligament balance were carried out at 0°, 30°, 60°, 90°, 120° flexion angle, which were monitored by the navigation system. Joint component gap change values during 30°- 0°, 60°- 0°, 90°- 0°, 120°- 0° flexion angle were calculated. The correlation between post operative flexion angles and pre-operative flexion angle, intra-operative joint component gaps, joint component gap change values and ligament balances were assessed using linear regression analysis.Introduction
Materials and methods
Recently, many researches of minimal incision surgery (MIS) total knee arthroplasty (TKA) have been reported, however very few of these contain clinical results. Regardless of this, MIS TKA is widely promoted as an improvement over traditional TKA. Although traditional TKA allows for excellent visualization, component orientation, fixation, and has been associated with remarkable long-term implant survival, many patients expect an extremely small incision, minimal or no pain and discomfort associated with their surgery, and certainly no increase in the complication rate. While there is some evidence that short term benefits may occur, there is concern that there may be an increase in complications with the use of MIS technique. We report here cases that malalignments in early phase were occurred after MIS TKAs. A consecutive series of MIS TKA for varus osteoarthritis undertaken by 2 surgeons at 2 centers during 2-year priod (2006–2007) was reviewed. During this interval, 50 MIS TKAs were performed. The mean age was 75.6 years (range 54 to 88 years). Cases for post-operatively infection were excluded. There were 2 cases that early failures due to varus sinking of tibial component were confirmed in early phase (7 and 3 months after primary surgery). We analyzed data between early failed cases and non-failed cases. Patients with early failure were younger, which showed a trend toward significance (p=0.11; failed; 66.5, non-failed; 75.9 years). There was no difference in amount of both medial and lateral side of distal femoral cut between early failed cases and non-failed cases. Proximal tibial cut was significantly larger in early failed cases compared with non-failed cases (p=0.01; failed; 16.5±4.5, nonfailed; 11.4±6.6). There was no difference in Femorotibial angle (FTA) after surgery between them. Substantial backgrounds of occurring early failure after MIS TKA are not still clarified, however, very early failure were occurred in patients, who had significant large cut of proximal tibia, in our experienced cases. MIS TKA may lead to varus imbalance due to increased amount of bony cut and decreased medial soft tissue release. Henceforth, the high prevalence of MIS failures occurring in early phase is disturbing, because of limited working space and warrants further investigation.
However, optimal duration for CFNB to decrease pain and accelerate rehabilitation program after TKA has not been addressed. We, therefore, compared three groups of patients which had different duration of CFNB (0, 2, and 5days) in this study.
Outcomes including visual analog scale (VAS) pain scores and range of motion (ROM) were compared at 1st, 3rd, 6th, 14th and 21th days after surgery. In addition, the postoperative date when patients could walk stably with parallel bar, walker, or T-cane were recorded and compared.
ROM did not show significant difference among the three groups over postoperative days 1st to 21st (P>
0.05), although groups with the CFNB showed greater ROM at all time points. The CFNB 5 days group obtained stable walking ability with T-cane earlier than other groups (P<
0.05). No patient had any side effect by having CFNB in this study.
Revision of the femur component in total hip arthroplasty using impaction bone grafting (IBG) was performed in 140 hips of 136 patients in our hospital. The mean age of the patients at the time of the femoral component revision was 72 years. The median of follow-up time was 80 months. 140 hips were operated with use of YU stem (Yamagata university stem, collared, not polished)104, Exeter stem 2, CPT 2, Restration 5, and others 27. The length of the stem was a regular stem 114, a long stem 26. The complications related to the revised hip consist of infection 5, dislocation 8, DVT9, fracture during operation 11. Four stems were revised due to infection and two due to loosening. YU stem is made of titanium alloy with collar, the surface of that stem is not polished and Ra is 0.27 μm. We started to apply IBG in 1994, there were no IBG instrument set and system available such as Exeter, CPT in Japan, so we had used YU stem. However, the result with YU stem was preferable and the implant was stable. Thus, we have been using YU stem. In the process, there have been a number of improvements in IBG instrument and system since we started using them. At first, all medullar cavity is filled with grafted bone up to proximal entry with moderate impaction. Along with guide pin, new medullar canal is made by drilling and insert stem tamper into the space to tighten the layer of impaction, then cement fixation of the stem is performed. This method made the operative time short and operative technique easy. There are several advantages of IBG technique we used. In revision THA, we can revise the stem with the same length of previous one again and exchange also a long stem to a regular length stem. In addition, the system make it possible to re-construct the case of distal medullar canal excessively filled with bone cement below stem, by digging about around 2 cm distally without need to remove all the cement. Severe bone atrophy and fragile of femur is also reconstructed by IBG. Impaction bone grafting technique with modified system has great merit to recover bone stock and to obtain implant stability after femoral reconstruction of revision surgery.
Visualization of the femoral medullar canal is troublesome in revision surgery. To obtain better visual field of the canal and assist cement extraction and following reconstructive procedures, flexible endoscope was applied in femoral revision. Mean age and time to revision of fifteen cemented totally replaced hips were 69.3 (42–83) and 14.9 (3–25) years, respectively. Preoperative status of the revision regarding type of stem loosening was classified as possible in four cases, probable in two, and definite in five classified by Harris et al. No marked finding of loosening was in four. That of bone defect was type I in four cases, Type II in three, and Type III in three by Gustilo. Five cases showed no marked loss of the defect. Extraction of cement mantle was performed under flexible endoscopic inspection. Impaction bone grafting was performed in eight cases. Time for cement removal in association with type of loosening and bone defect were evaluated as well as analysis of periprosthetic complications. Retained cement mantle was extractable in all cases under good exposure and with maintenance of efficient working space. Interfacial granulation and fibrous tissues between bone and cement were easily removed. Endoscopic time for cement removal was 41.7 ± 10.3 minutes in average. It was 51.8 ± 6.2 minutes in no loosening. 41.3 ± 11.1 minutes in possible loosening, 38.5 ± 9.2 minutes in probable loosening, and 35.4 ± 8.3 minutes in definite loosening, which depended on the status of fixation between bone and cement. Type of bone defect also influenced the time. It was 52.4 ± 5.6 minutes in the cases of no marked bone loss, 43.8 ± 3.5 minutes in Gustilo type I, 28.3 ± 3.5 minutes in Type II, and 34.7 ± 2.5 minutes in Type III. The procedure was effective to prepare suitable bone bed for reconstruction, which allowed proper stem settlement and facilitated recovery of bone stock in the cases of impaction bone grafting. Intra-operative blood loss was 377 ml (212 – 1430) and total amount of blood loss including post surgical drainage was 593 ml (316 – 1680). Type of loosening and bone defect did not affect both whole and intra-operative bleeding volume. However, three occult fractures happened, in which two revealed minor cement leakage and one required additional osteosynthesis with extensive approach. The data indicated that flexible medullo-endoscope could provide good visual field with maintenance of working space, potentially contributing to less invasive femoral revision surgery, if it would be combined with refined device for cement extraction to improve accuracy of the procedure.
Infection has been one of the serious complications after total hip arthroplasty. It forces physical and mental stress to the patients. We have routinely applied two-stage revision for infected replaced hip joint. Cement spacer mold technique has been used for the purpose since 2002. The purpose of this study is to analysis of peri-operative status and functional outcome of the patients underwent the two-stage revision procedure. Nine joints of the eight patients were included in the study. Seven patients were female and one was male and its average age was 64 years (55–81 years). After removal of implant, antibiotic-loaded cement spacer prosthesis which was made by the cement spacer mold (Biomet, Warsaw, USA), was inserted. The leg length, range of motion of the hip, walking ability and complications between first and second-stage operation were analyzed. The change of leg length after first stage operation compared with prior operation was ranged from −18 mm to +13 mm with an average of 20 mm. Average range of hip flexion was 70°(40–90°). Patients could walk with crutches after first-stage operation. Complications after first stage operation were found in two cases; fracture of femoral cement spacer prosthesis and dislocation of the femoral spacer. There was no case of recurrence of infection. Clinical assessment of two-stage revision for infected replaced hip joint with cement spacer mold showed favorable functional outcome and a few complications after first-stage operation. It also showed satisfactory short-term outcome after second-stage operation.
There exists two important pathologies in degenerative lumbosacral kyphosis (flat back), such as loss of lumbar lordosis and posterior rotation of the pelvis. Patients with this deformity complaint marked fatigue in lumbosacral region and disturbances on standing and walking. Conservative treatment is seemed to be difficult, and surgical treatment may be selected for this deformity. Our surgical strategy is posterior shortening and anterior rotation of pelvis. Surgical procedure is tranvertebral decancellation closed wedge osteotomy, correction by shortening and lumbosacral fixation by intrasacral method. Radiographic assessment around the hip axis was performed by Jackson method on standing entire spine film. 5 females and 2 males were operated on by this method. Mean age at the operation was 67 yrs (57–82). Mean follow-up was 24 months (12–36). Mean operative time was 480 minutes (320–600). Mean estimated blood loss was 1440ml (985–2415). Mean pelvic angle was 41 degrees before the operation. At follow-up, mean value was 33 degrees. Preoperative mean local kyphosis was 4.7 degrees. Postoperative mean local lordosis was 24.1 degrees, average correction was 30 degrees. No loss of correction occurred in fused area. Clinical symptoms were remarkably improved after the operation. There was no major complication in this series.