Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims

This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH).

Methods

The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1641 - 1641
1 Oct 2021
Matsumoto T Takayama K Ishida K Hayashi S Hashimoto S Kuroda R


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 17 - 17
1 Feb 2020
Hayashi S Hashimoto S Takayama K Matsumoto T Kuroda R
Full Access

Introduction

Several reports demonstrated the overcoverage of the anterior acetabulum. Anterior CE angle over 46°may be a probable risk factor for pincer FAI syndrome after a rotational acetabular osteotomy. In addition, a highly anteverted femoral neck, reported as a risk factor for posterior impingement, has been found in DDH patients. These findings indicate proper acetabular reorientation is essential to avoid anterior or posterior impingement after periacetabular osteotomy (PAO). The aim of this study was to evaluate the relationship between acetabular three-dimensional (3D) alignment reorientation and clinical range of motion (ROM) after periacetabular osteotomy (PAO).

Methods

A total of 53 patients who underwent curved PAO (CPO) for DDH from January 2014 to April 2017 were selected. Three (5.7%) of them were lost to follow-up. Therefore, the data from 58 hips, contributed by 50 patients (44 women and 6 men), were included in the analysis. Pre- and postoperative computed tomography (CT) scans from the pelvis to the knee joint were performed and transferred to a 3D template software (Zed Hip; Lexi, Tokyo, Japan). The pelvic plane axis was defined according to the functional pelvic plane. The pre- and postoperative lateral and anterior 3D center-edge (CE) angles were measured on the coronal and sagittal views through the center of the femoral head. The pre- and postoperative 3D center-edge (CE) angles and femoral anteversion were measured and compared with clinical outcomes, including postoperative ROM.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 39 - 39
1 Feb 2020
Suda Y Muratsu H Hiranaka Y Tamaoka T Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

The influences of posterior tibial slope on the knee kinematics have been reported in both TKA and UKA. We hypothesized the posterior tibial slope (PTS) would affect the sagittal knee alignment after UKA. The influences of PTS on postoperative knee extension angle were investigated with routine lateral radiographies of the knee after UKA.

Materials & Methods

Twenty-four patients (26 knees; 19 females, 7 males) underwent medial UKA were involved in this study. Average age was 74.8 ± 7.2 years. The mean preoperative active range of motion were − 4.1° ± 6.3°in extension and 123.2° ± 15.5° in flexion. All UKAs were performed using fixed bearing type UKA (Zimmer Biomet, ZUK), with adjusting the posterior slope of the proximal tibial bone cut according to the original geometry of the tibia. Routine lateral radiographies of the knee were examined preoperatively, 6 months after the surgery. PTS and knee extension angles with maximal active knee extension (mEXT) and one-leg standing (sEXT) were radiographically measured. We used the fibular shaft axis (FSA) for the sagittal mechanical axis of the tibia. PTS was defined as the angle between the medial tibial plateau and the perpendicular axis of FSA. Extension angles (mEXT and sEXT) were defined as the angles between FSA and distal femoral shaft axis (positive value for hyperextension). The changes of PTS and the influences of PTS on sEXT at each time period were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 13 - 13
1 Feb 2020
Tanaka S Tei K Minoda M Matsuda S Takayama K Matsumoto T Kuroda R
Full Access

Introduction

Acquiring adaptive soft-tissue balance is one of the most important factors in total knee arthroplasty (TKA). However, there have been few reports regarding to alteration of tolerability of varus/valgus stress between before and after TKA. In particular, there is no enough data about mid-flexion stability. Based on these backgrounds, it is hypothesized that alteration of varus/valgus tolerance may influence post-operative results in TKA. The purpose of this study is an investigation of in vivo kinematic analyses of tolerability of varus/valgus stress before and after TKA, comparing to clinical results.

Materials and Methods

A hundred knees of 88 consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. The kinematic parameters of the soft-tissue balance, and amount of coronal relative movement between femur and tibia were obtained by interpreting kinematics, which display graphs throughout the range of motion (ROM) in the navigation system. Femoro-tibial alignments were recorded under the stress of varus and valgus before the procedure and after implantation of all components. In each ROM (0, 30, 60, 90, 120 degrees), the data of coronal relative movement between femur and tibia (tolerability) were analyzed before and after implantation. Furthermore, correlations between tolerability of varus/valgus and clinical improvement revealed by ROM and Knee society score (KSS) were analyzed by logistic regression analysis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 38 - 38
1 Feb 2020
Tamaoka T Muratsu H Tachibana S Suda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

Patients-reported outcome measures (PROMs) have been reported as the important methods to evaluate clinical outcomes in total knee arthroplasty (TKA). The patient satisfaction score in Knee Society Score (KSS-2011) has been used in the recent literatures. Patient satisfaction was subjective parameter, and would be affected by multiple factors including psychological factors and physical conditions at not only affected joint but also elsewhere in the body. The question was raised regarding the consistency of patient satisfaction score in KSS-2011 to other PROMs.

The purpose of this study was to investigate the correlation of patient satisfaction in KSS-2011 to other categories in KSS-2011 and to other PROMs including Forgotten Joint Score (FJS-12), EuroQol-5 Dimensions (EQ-5D) and 25-questions in Geriatric Locomotive Function Scale (GLFS-25).

Material & Method

83 patients over 65 years old with osteoarthritic knees were involved in this study. All patients underwent CR-TKAs (Persona CRR). The means and ranges of demographics were as follows: age; 74.5 years old (65–89), Hip-Knee-Ankle (HKA) angle; 12.4 (−6.2–22.5) in varus. We asked patients to fulfill the questionnaire including KSS-2011, FJS-12, EQ-5D and GLFS-25 at 1-year postoperative follow-up visit. KSS-2011 consisted of 4 categories of questions; patient satisfaction (PS), symptoms, patient expectations (PE), functional activities (FA).

We evaluated the correlation of PS to other PROMs using simple linear regression analyses (p<0.001).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 41 - 41
1 Apr 2018
Kamimura M Muratsu H Kanda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

Both measured resection technique and gap balancing technique have been important surgical concepts in total knee arthroplasty (TKA). Modified gap technique has been reported to be beneficial for the intra-operative soft tissue balancing in posterior-stabilizing (PS) -TKA.

On the other hand, we have found joint distraction force changed soft tissue balance measurement and medial knee instability would be more likely with aiming at perfect ligament balance at extension in modified gap technique. The medial knee stability after TKA was reported to essential for post-operative clinical result.

We have developed a new surgical concept named as “medial preserving gap technique” for varus type osteoarthritic (OA) knees to preserve medial knee stability and provide quantitative surgical technique using tensor device.

The purpose of this study was to compare post-operative knee stability between medial preserving gap technique (MPGT) and measured resection technique (MRT) in PS-TKA.

Material & Method

The subjects were 140 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 70 patients and MRT in 70 patients. There were no significant differences between two groups in the pre-operative clinical features including age, sex, ROM and deformity.

Originally developed off-set type tensor device was used to evaluate both center gap and varus angle with 40 lbs. of joint distraction force. The extension gap preparation was identical in both group. In MPGT group, femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar osteotomy.

The knee stabilities at extension and flexion were assessed by stress radiographies; varus-valgus stress test with extension and stress epicondylar view with flexion, at one-month and one-year after TKA. We measured joint opening distance (mm) at medial and lateral compartment at both knee extension and flexion.

Joint opening distances were compared between two groups using unpaired t-test, and the difference between medial and lateral compartment in each group was compared using paired t- test (p<0.05).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 52 - 52
1 Apr 2018
Sawauchi K Muratsu H Kamenaga T Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Background

In recent literatures, medial instability after TKA was reported to deteriorate early postoperative pain relief and have negative effects on functional outcome. Furthermore, lateral laxity of the knee is physiological, necessary for medial pivot knee kinematics, and important for postoperative knee flexion angle after cruciate-retaining total knee arthroplasty (CR-TKA). However, the influences of knee stability and laxity on postoperative patient satisfaction after CR-TKA are not clearly described.

We hypothesized that postoperative knee stability and ligament balance affected patient satisfaction after CR-TKA. In this study, we investigated the effect of early postoperative ligament balance at extension on one-year postoperative patient satisfaction and ambulatory function in CR-TKAs.

Materials & Methods

Sixty patients with varus osteoarthritis (OA) of the knee underwent CR-TKAs were included in this study. The mean age was 73.6 years old. Preoperative average varus deformity (HKA angle) was 12.5 degrees with long leg standing radiographs.

The knee stability and laxity at extension were assessed by stress radiographies; varus-valgus stress X-ray at one-month after operation. We measured joint separation distance (mm) at medial compartment with valgus stress as medial joint opening (MJO), and distance at lateral compartment with varus stress as lateral joint opening (LJO) at knee extension position. To analyze ligament balance; relative lateral laxity comparing to the medial, varus angle was calculated.

New Knee Society Score (NKSS) was used to evaluate the patient satisfaction at one-year after TKA.

We measured basic ambulatory functions using 3m timed up and go test (TUG) at one-year after surgery.

The influences of stability and laxity parameters (MJO, LJO and varus angle at extension) on one-year patient satisfaction and ambulatory function (TUG) was analyzed using single linear regression analysis (p<0.01).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 42 - 42
1 Apr 2018
Watanabe S Muratsu H Yahiro S Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Background

Knee osteoarthritis (OA) is a major cause of ambulatory disabilities. Although total knee arthroplasty (TKA) has been reported as the most effective treatment for severe knee OA, quantitative evaluation of ambulatory function have not been well investigated.

We hypothesized that better functional recovery would result in better patient satisfaction. The purpose of this study was to quantitatively evaluate ambulatory functional recovery and assess the influence on patient satisfaction after TKA.

Material and Methods

90 patients (80 females and 10 males) were involved in this study. The mean age at TKA was 75.2 ± 5.8 years. Patients were subjected to 3 meters timed up and go test (TUG) to evaluate ambulatory function. TUG was performed at 6 time periods; before surgery, 2 weeks, 1, 3, 6 months, and 1 year after surgery. We also asked the patients to fill out the questionnaire of patient satisfaction category in the New Knee Society Score at 1 year after TKA.

The sequential changes in TUG were analyzed using repeated measures ANOVA (p<0.05). The influences of each parameter (age, TUGs) on the patient satisfaction score were analyzed with simple regression analysis (p<0.05).


Bone & Joint Research
Vol. 7, Issue 3 | Pages 252 - 262
1 Mar 2018
Nishida K Matsushita T Takayama K Tanaka T Miyaji N Ibaraki K Araki D Kanzaki N Matsumoto T Kuroda R

Objectives

This study aimed to examine the effects of SRT1720, a potent SIRT1 activator, on osteoarthritis (OA) progression using an experimental OA model.

Methods

Osteoarthritis was surgically induced by destabilization of the medial meniscus in eight-week-old C57BL/6 male mice. SRT1720 was administered intraperitoneally twice a week after surgery. Osteoarthritis progression was evaluated histologically using the Osteoarthritis Research Society International (OARSI) score at four, eight, 12 and 16 weeks. The expression of SIRT1, matrix metalloproteinase 13 (MMP-13), a disintegrin and metalloproteinase with thrombospondin motifs-5 (ADAMTS-5), cleaved caspase-3, PARP p85, and acetylated nuclear factor (NF)-κB p65 in cartilage was examined by immunohistochemistry. Synovitis was also evaluated histologically. Primary mouse epiphyseal chondrocytes were treated with SRT1720 in the presence or absence of interleukin 1 beta (IL-1β), and gene expression changes were examined by real-time polymerase chain reaction (PCR).


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 640 - 646
1 May 2017
Matsumoto T Takayama K Ishida K Hayashi S Hashimoto S Kuroda R

Aims

The aim of this study was to compare the post-operative radiographic and clinical outcomes between kinematically and mechanically aligned total knee arthroplasties (TKAs).

Patients and Methods

A total of 60 TKAs (30 kinematically and 30 mechanically aligned) were performed in 60 patients with varus osteoarthritis of the knee using a navigation system. The angles of orientation of the joint line in relation to the floor, the conventional and true mechanical axis (tMA) (the line from the centre of the hip to the lowest point of the calcaneus) were compared, one year post-operatively, on single-leg and double-leg standing long leg radiographs between the groups. The range of movement and 2011 Knee Society Scores were also compared between the groups at that time.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 40 - 40
1 Mar 2017
Takayama K Matsumoto T Muratsu H Ishida K Matsushita T Kuroda R
Full Access

Background

Post-operative (postop) lower limb alignment in unicompartmental knee arthroplasty (UKA) has been reported to be an important factor for postop outcomes. Slight under-correction of limb alignment has been recommended to yield a better clinical outcomes than neutral alignment. It is useful if the postop limb alignment can be predicted during surgery, however, little is known about the surgical factors affecting the postop limb alignment in UKA. The purpose of this study was to examine the influence of the medial tibial joint line elevation on postop limb alignment in UKA.

Methods

Seventy-four consecutive medial UKAs were enrolled in this study. All the patients received a conventional fixed bearing UKA. Pre-operative (preop) and postop limb alignment was examined using long leg radiograph and lower limb alignment changes were calculated. Femoral and tibial osteotomy thickness were measured during surgery. Medial tibial joint line change was defined as polyethylene thickness minus tibial osteotomy thickness and sawblade thickness (1.27mm). Positive values indicated a tibial joint line elevation. Medial femoral joint line change was defined as femoral distal component thickness (6.5mm) minus femoral distal osteotomy thickness and sawblade thickness. Positive values indicated a femoral joint line reduction. Medial joint distraction width was also calculated by tibial joint line elevation plus femoral joint line reduction. The correlation of lower limb alignment change with polyethylene insert thickness, the medial tibial joint line elevation, femoral joint line reduction, or joint distraction width were analyzed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 48 - 48
1 Mar 2017
Tei K Minoda M Shimizu T Matsuda S Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed and widely used. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femoro-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femoro-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system and tensor device intra-operatively in TKA.

Materials and Methods

Sixty-one consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. During surgery, using a tensor device, after bony cut of femur and tibia, joint gaps were assessed in 0 and 90 degrees in flexion. Then, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal and sagittal relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) in the navigation system. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with a ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p< 0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 25 - 25
1 Feb 2017
Inokuchi T Ishida K Shibanuma N Matsumoto T Takayama K Toda A Kodato K Kuroda R Kurosaka M
Full Access

Introduction

Range of motion (ROM) is one of the important factor for better functional outcome after total knee arthroplasty (TKA). In posterior cruciate ligament (PCL) retaining (CR) TKA, adequate PCL function is suggested to be important for better kinematics and ROM. However, intraoperative assessment of PCL function is relatively subjective, thus more objective evaluation is required to improve the functional outcomes after TKA. In clinical practice, tibial posterior sagging sign is well known to indicate PCL deficiency. Hence, we hypothesized that intraoperative femorotibial antero-posterior (AP) changes at 90° of flexion indirectly reflected the PCL function and associated with postoperative maximum flexion angles in CR TKA. The purpose of this study was to investigate the correlation between intraoperative femorotibial AP changes at 90° of flexion and postoperative maximum flexion range in navigated CR TKA.

Methods

Between March 2014 and March 2015, forty patients with varus osteoarthritis underwent primary TKA. All of the cases were using same types of implant (Triathlon; Stryker Orthopedics, Mahwah, NJ, USA), with an image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker). PCL was retained and cruciate substituting (CS) inserts were used in all cases. The mean age at the time of surgery was 71.7 ± 6.8 years old (ranging: 62 – 85). The mean follow-up was 10.9 ± 6.4 months. After minimum release of medial and lateral soft tissue, resection of anterior cruciate ligaments, and protection of PCL, registration and kinematic measurements were performed prior to bone resection. The kinematic measurements were performed again after implantation. The center of proximal tibial and distal femur were defined during registration. The point of proximal tibia was projected to the mechanical axis of femur and the distance between the projected point and the distal femur at 90° of flexion were measured and defined as femorotibial AP position. Distal relative to the center of distal femur indicates as minus, and proximal relative to the point indicates as plus. The correlation between the intraoperative changes of AP position and postoperative maximum flexion angles were investigated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 42 - 42
1 Feb 2017
Kamenaga T Yamaura K Kataoka K Yahiro S Kanda Y Oshima T Matsumoto T Maruo A Miya H Muratsu H Kuroda R
Full Access

Objective

As the aging society progresses rapidly in Japan, the number of elderly patients underwent TKA is increasing. These elderly patients do not expect to do sports, but regain independency in the activity of daily living. Therefore, we measured basic ambulatory function quantitatively using 3m timed up and go (TUG) test. We clinically experienced patient with medially unstable knee after TKA was more likely to result in the unsatisfactory outcome. We hypothesized that post-operative knee stability influenced ambulatory function recovery after TKA. In this study, we evaluated ambulatory function and knee stability quantitatively, and analyzed the effect of knee stability on the ambulatory function recovery after TKA.

Materials & Methods

Seventy nine patients with varus type osteoarthritic knees underwent TKA were subjected to this study. The mean age of surgery was 72.4 years old. Preoperative standing coronal deformity was 9.6 degrees in varus. TUG test results in less duration with faster ambulatory function. TUG (seconds) was measured at 3 time periods; pre-operatively, at hospital discharge and 1year after surgery. To standardize TUG recovery time during 1 year after TKA, we defined TUG recovery rate as the percentage of recovery time to the pre-operative TUG as shown in the following equation. TUG recovery rate (%) = (TUG pre-op –TUG 1y po) / TUG pre-op ×100

We also evaluated the knee stability at hospital discharge and 1year after surgery. The knee stability at extension and flexion were assessed by varus and valgus stress radiography using Telos (10kg) and stress epicondylar view with 1.5kg weight at the ankle respectively. Image analyzing software was used to measure joint separation distance (mm) at medial as medial joint opening (MJO) and at lateral as lateral joint opening (LJO) at both knee extension and flexion. (Fig.1)

The sequential change of TUG was analyzed using repeated measures ANOVA (p<0.05). The influence of joint opening distances (MJO and LJO at extension and flexion) on TUG 1y po and TUG recovery rate were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 141 - 141
1 Feb 2017
Matsumoto T Takayama K Ishida K Tanaka T Inokuchi T Matsushita T Kuroda R
Full Access

Purpose

Recently, kinematic aligned total knee arthroplasty (TKA) has gained interest for achieving better clinical outcomes over mechanical aligned TKA. The primary goal of kinematic aligned TKA is to position the femoral and tibial components so that the angles and levels of the distal and posterior femoral joint lines and the tibial joint line are each restored to the patient's natural alignment, and not to a neutral limb alignment that is unnatural for most patients. Despite good clinical outcomes reported at short to mid-term follow-up, surgeons should know reasons why this method is useful and safe surgery and carefully assess the long-term outcomes until this new technique is settled as standardized procedure for TKA. The main purpose of the present study was to compare postoperative radiography and clinical scores following kinematic and mechanical aligned TKA.

Methods

Sixty TKAs—30 kinematic and 30 mechanical aligned—were performed in patients with varus-type osteoarthritis using a navigation system. Using postoperative double-leg and single-leg standing long leg radiographs, joint line orientation angle to the floor, conventional mechanical axis (cMA), and true mechanical axis (tMA; line from hip center to the lowest point of calcaneus) were compared between the two groups. One-year after surgeries, range of motion and the patient-derived score of the 2011 Knee Society Score (2011 KSS), which includes four categories: symptoms, patient satisfaction, patient expectations, and functional activities, e.g., walking/standing, standard activities, advanced activities, and discretionary activities, were compared between the two groups


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 29 - 29
1 Feb 2017
Ishida K Shibanuma N Toda A Kodato K Inokuchi T Matsumoto T Takayama K Kuroda R Kurosaka M
Full Access

PURPOSE

Total knee arthroplasty (TKA) is a successful technique for treating painful osteoarthritic knees. However, the patients' satisfaction is not still comparable with total hip arthroplasty. Basically, the conditions with operated joints were anterior cruciate ligament (ACL) deficient knees, thus, the abnormal kinematics is one of the main reason for the patients' incomplete satisfaction. Bi-cruciate stabilized (BCS) TKA was established to reproduce both ACL and posterior cruciate ligament (PCL) function and expected to improve the abnormal kinematics. However, there were few reports to evaluate intraoperative kinematics in BCS TKA using navigation system. Hence, the aim in this study is to reveal the intraoperative kinematics in BCS TKA and compare the kinematics with conventional posterior stabilized (PS) TKA.

Materials and Methods

Twenty five consecutive subjects (24 women, 1 men; average age, 77 years; age range, 58–85 years) with varus osteoarthritis undergoing navigated BCS TKA (Journey II, Smith&Nephew) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum medial soft tissue release, ACL and PCL resection, and osteophyte removal. Then, kinematics including tibiofemoral rotational angles from maximum extension to maximum flexion were recorded. The measurements were performed again after implantation. We compared the kinematics with the kinematics of paired matched fifty subjects who underwent conventional posterior stabilized (PS) TKA (25 subjects with Triathlon, Stryker; 25 subjects with PERSONA, ZimmerBiomet) using navigation statistically.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 44 - 44
1 Feb 2017
Kanda Y Kudo K Kamenaga T Yahiro S Kataoka K Oshima T Matsumoto T Maruo A Miya H Muratsu H Kuroda R
Full Access

Introduction

Although gap balancing technique has been reported to be beneficial for the intra-operative soft tissue balancing in posterior-stabilized (PS)-TKA, excessive release of medial structures for achieving perfect ligament balance would be more likely to result in medial instability, which would deteriorate post-operative clinical results. We have modified conventional gap balancing technique and devised a new surgical concept; named as “medial gap technique” aiming at medial stability with permitting lateral looseness, as physiologically observed in normal knee.

Objective

We compared intra-operative soft tissue balance between medial gap technique (MGT) and measured resection technique (MRT) in PS-TKAs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 65 - 65
1 May 2016
Takayama K Matsumoto T Muratsu H Ishida K Kuroda R Kurosaka M
Full Access

The influence of amount of tibial posterior slope changes on joint gap and postoperative range of motion was investigated in 35 patients undergoing unicompartmental knee arthroplasty (UKA). Component gap between the medial tibial osteotomy surface and the femoral trial prosthesis was measured throughout the range of motion using a tensor. The mean tibial posterior slope decreased from 10.2 to 7.3 degrees. Increased tibial slope change was positively correlated with component gap differences of 90° −10°, 120° −10°, and 135° −10° and negatively correlated with postoperative extension angle. Increasing tibial slope should be avoided to achieve full extension angle after UKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 52 - 52
1 May 2016
Ishida K Shibanuma N Toda A Matsumoto T Takayama K Sasaki H Oka S Kodato K Kuroda R Kurosaka M
Full Access

Purpose

To investigate the tibiofemoral rotational profiles during surgery in navigated posterior-stabilized (PS) total knee arthroplasty (TKA) and investigated the effect on postoperative maximum flexion angles.

Materials and Methods

At first, twenty-five consecutive subjects (24 women and 1 man; age: mean, 77 years; range, 58–85 years) with varus osteoarthritis treated with navigated PS TKA (Triathlon, Stryker, Mahwah, NJ) were enrolled in this study. Kinematic parameters, including the tibiofemoral rotational angles from maximum extension to maximum flexion, were recorded thrice before and after PCL resections, and after implantation. The effect of PCL resection and component implantation on tibiofemoral rotational kinematics was statistically evaluated. Then, the effect of tibiofemoral rotational alignment changes on the postoperative maximum angles were retrospectively examined with 96 subjects (84 women, 12 men; average age, 76 years; age range, 56–88 years) who underwent primary TKA.