Due to well-known complications of metal-on-metal hip resurfacing arthroplasty the indication for this procedure has significantly decreased over the past years. As a high number of patients is currently living with resurfacing implants, however, there is a clear need for information about the longterm results and especially about the rate of local as well as systemic adverse effects. We retrospectively reviewed our first 95 patients who had 100 consecutive BHR hip resurfacings performed from 1998–2001. Median age at surgery was 52 years (range, 28–69 years); 49% were men. After a mean follow-up period of 16.1 years (range 15.2 – 17.6 years) we assessed survival rate (revision for any reason as endpoint), radiographic changes and patient-related outcome in patients who had not undergone revision. In addition we measured whole blood concentrations of cobalt at follow-up. 17% of our patients in the original cohort were lost to follow-up. In the remaining patients the 16-year survivorship was 80.1%. The overall survival rate was slightly higher in males (80.6%) than in females (77.1%). The WOMAC overall score showed a median value of 91.7 points (range 35.4 – 100). Median whole blood ion levels were 1.9 µg/L for cobalt (0.6 – 140.2 µg/L), 14.9% of patients showed elevated levels. The number of patients with relevant radiographic signs of local adverse reactions to metal debris was relatively low. In contrast to earlier reports and very few other longterm studies our results show an unsatisfactory performance of resurfacing. In particular the outcome of male patients deteriorated between 10 and 16 years of follow-up. Although only a small number of patients shows relevant elevation of metal-ion levels, the clinical relevance has still to be determined.
Computer navigation in total knee arthroplasty (TKA) has proven to significantly reduce the number of outliers in prosthesis positioning and to improve mechanical leg alignment. Despite these advantages the acceptance of navigation technologies is still low among orthopaedic surgeons. The time required for navigation might be a reason for the low acceptance. The aim of the study was to test whether software and instrument improvements made in an established navigation system could lead to a significant navigation acquisition time reduction. An improved and the current version of the TKA navigation software were used to perform surgery trials on a human cadaveric specimen by two experienced orthopaedic surgeons. A significant effect of the “procedure” (navigation software version) on the navigation time (p< 0.001) was found, whereas the difference between surgeons was not significant (p= 0.2). There was no significant interaction between surgeon and navigation software version (p= 0.5). The improved version led to a significant navigation acquisition time reduction of 28%. Software and instrument improvements led to a statistically significant navigation acquisition time reduction. The achieved navigation acquisition time decrease was independent from surgeon. Specific instrument and software improvements in established navigation systems may significantly decrease the surgery time segments where navigation takes place. However, the total navigation acquisition time is low in comparison to the total surgery time.
For seven of these nine patients, kinematic analysis was available during passive flexion from approximately 0° to 120°. There were no substantial differences in the average range of total axial rotation achieved in this group compared to the normal group, but the pattern of motion during that range was quite different. While external rotation steadily increased with knee flexion in the normal group, there was internal rotation between 30° and 80° of flexion in the group with more than 10° rotational mismatch.
Mobile-bearing total knee replacement (TKR) designs are advocated for their theoretical ability to self-align and accommodate small errors in rotational (axial) alignment. However, for many mobile-bearing TKR, the relationships between axial alignment, knee axial rotation and bearing motion during knee flexion are undefined. This study evaluates whether mobile-bearing TKR with axial alignment outside surgical norms have different rotations and motions compared to well-aligned TKR. This prospective study included 67 patients implanted with cruciate-retaining mobile-bearing TKR with a rotating platform polyethylene bearing (Scorpio PCS, Stryker). Axial alignment of femoral components relative to the transepicondylar axis and tibial components relative to the medial tibial tuberosity was measured from postoperative CT scans. TKR were categorized as “normal” or “outliers” according to defined tolerances for surgical axial alignment relative to anatomic landmarks (+3° for femur, +10° for tibia) and combined axial mismatch (+5° between femoral and tibial components). Knee kinematics and axial rotation were measured from fluoroscopic images acquired immediately after TKR during 0° to 120° of passive knee flexion. Total knee axial rotation (relative motion between the femoral component and tibial baseplate), femoral component axial rotation on the bearing articular surface, and bearing axial rotation on the tibial baseplate were determined using published shape-matching techniques. External rotation during knee flexion averaged 8.4°+6.1°, with two phases of axial rotation motion distinguished in all groups. External rotation from 0°–80° occurred primarily due to bearing axial rotation on the tibial baseplate. Beyond 80°, there was combined bearing rotation and external rotation of the femoral component on the polyethylene articular surface, with the latter dominating the motion pattern. Axial rotation varied with the component axial alignment. Among TKR with normal axial alignment, external rotation steadily increased with knee flexion. Among anatomic landmark outliers, there was a transition to internal rotation from 20°–50° and limited (<
1°) axial rotation beyond 80°. Among combined axial mismatch outliers, the magnitude of axial rotation was significantly less than normal TKR throughout the flexion range (p<
0.001) due to opposite rotations between the femoral component and polyethylene bearing. Achieving appropriate axial alignment using defined bony landmarks remains a challenge. In this study, approximately 30% of TKR did not have suitable axial alignment, with notable combined axial mismatch in tibial-femoral alignment. Axial rotation misalignment affected the kinematics and knee rotation motions over the passive flexion range and appears to result in opposite rotations of the femur-bearing and bearing-base-plate articulations.
Referencing the tibial rotation on a line from the lateral border of the medial third of the tibial tubercle to the center of the tibial tray resulted in a better femoro-tibial alignment than using the medial border of tibial tubercle as landmark. Surgeons using fixed bearings with a high conformity between the inlay and the femoral component should be aware of this effect to avoid premature polyethylene wear.
The femoral component showed a median deviation from the transepicondylar axis of 1,7° (range: 3,1° external rotation to 4,4° internal rotation) in the navigated group and of 1,0° (range: 3,4° external rotation to 4,3° internal rotation) in the conventional implantations. The tibial component showed a much greater range of rotational deviation from the medial third of the tuberosity in median 5,3° (range: 14,9° external rotation to 26° internal rotation) in the navigated group and 4,8° (range: 6,5° external rotation to 23,8° internal rotation) in the conventional implantations.