header advert
Results 1 - 6 of 6
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 70 - 70
1 Apr 2018
Kim S Chae S Kang J
Full Access

Background

Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty has been recommended, especially in patients with a small glenoid or insufficient bony stock due to severe glenoid wear. However, effect of a smaller baseplate on stability of the glenoid component has not been evaluated. The purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial primary stability of the glenoid component compared to that with a baseplate of a commonly used size (29 mm) by finite element analysis.

Methods

Computed tomography (CT) scans of fourteen scapulae were acquired from cadavers with no apparent deformity or degenerative change. Glenoid diameter corresponding to the diameter of the inferior circle of glenoid was measured using a caliper and classified into the small and large glenoid groups based on 25mm diameter. CT slices were used to construct 3-dimensional models with Mimics (Materialise, Leuven, Belgium). A corresponding 3D Tornier Aequalis® Reversed Shoulder prosthesis model was generated by laser scanning (Rexcan 3D Laser Scanner, Solutionix, Seoul, Korea). Glenoid components with 25mm and 28mm diameter of the baseplate were implanted into the scapular of small and large glenoid group, respectively. Finite element models were constructed using Hypermesh 11.0 (Altair Engineering, Troy, MI, USA) and a reverse engineering program (Rapidform 3D Systems, Inc., Rock Hill, SC, USA). Abaqus 6.10 (Dassault Systemes, Waltham, MA) was used to simulate 30o, 60o, and 90o glenohumeral abduction in the scapular plane. Single axial loads of 686N (1 BW) at angles of 30o, 60o, and 90o abduction were applied to the center of the glenosphere parallel to the long axis of the humeral stem. Relative micromotion at the middle and inferior thirds bone–glenoid component interface, and distribution of bone stress under the glenoid component and around the screws were analyzed. Wilcoxon's rank-sum test was used for statistical comparison and p < 0.05 was considered as a minimum level of statistical significance.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 47 - 47
1 Feb 2017
Kang J Yang S
Full Access

Purpose

The purpose of this study was to assess the efficacy of newly designed topical administration of tranexamic acid (TXA) in reducing postoperative bleeding in total hip arthroplasty (THA) and bipolar hip hemiarthroplasty (BHA).

Method

Consecutive series of 160 hip arthroplasty were enrolled for this study. Topical administration of TXA was done in group 1(40 hips of THA and 40 hips of BHA). We compared the amount of blood loss and rates of postoperative transfusion with group 2 (40 cases of THA and 40 cases of BHA) in which TXA solution was not applied


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 80 - 80
1 May 2016
Kang J Moon K
Full Access

Purpose

Topical application of tranexamic acid (TXA) to bleeding wound surfaces reduces blood loss in patients undergoing some major surgeries, without systemic complications. The objective of this study was to determine if TXA applied topically reduced postoperative bleeding and transfusion rates after primary total hip arthroplasty (THA) and primary bipolar hemiarthroplasty (BA).

Methods

We retrospectively compared 77 patients undergoing hip arthroplasty surgery in which tranexamic acid was routinely used, to a group of 70 patients from a similar time frame prior to the introduction of tranexamic acid use. In the former group 40 patients had THA and 37 patients BA; in the latter group 35 patients underwent THA and 35 patients BA. In both THA and BA, the joint was bathed in TXA solution (at a concentration of 3.0 g TXA per 100 mL saline) at three points during the procedure. The primary outcome was blood loss calculated from the difference between the preoperative hemoglobin level and the corresponding lowest postoperative value or hemoglobin level prior to transfusion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 212 - 212
1 Mar 2013
Kang J Moon KH Kwon D Shin SH Rhu DJ Park YS
Full Access

Introduction

The natural history of osteonecrosis of the femoral head (ONFH) is not cleanly understood, but most of them progresse to the joint destruction and requires total hip replacement arthroplasty. There are several head preserving procedure, but no single therapeutic method proved to be effective in preventing progression of the disease. The possibility has been raised that implantation of bone marrow containing osteogenic precursors may be effective in the treatment of this disease. However, there are no long-term follow-up results of cell therapy for ONFH. AS far as we know, there are no reports about bone graft and cell therapy for ONFH. Therefore, we performed a prospective clinical and radiological evaluation on ONFH treated with core decompression combined with autoiliac bone graft and an implantation of autologous bone marrow cells as a therapeutic method of ONFH.

Materials and Methods

Sixty-one hips in 52 patients with ONFH were included in this study. The average follow-up of the patients was 68 (60∼88) months. The necrotic lesions were classified according to their size and location, and we compared the results.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 211 - 211
1 Mar 2013
Kang J Moon KH Kwon D Shin SH Rhu DJ
Full Access

Purpose

This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old.

Materials and Methods

The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 12 years (range, 10–15 years).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 88 - 88
1 Sep 2012
Kang J Wazir A Fong A Joshi S Marjoram T Hussein A Reddy R Ashford RU Godsiff S
Full Access

Objectives

All Polyethylene Tibial components in Total Knee Arthroplasty have been in use for some years, studies showing equivalent results to Total Knee Arthroplasty (TKA) with metal-backed Tibial components at 10 years have shown no significant difference between the two on radiostereometric analysis and revision rates[1].

Post operative patient outcome data using standard metal-backed Tibial components is widely reported in the literature. This study is looking at patient outcomes following All-polyethylene tibial component TKA. We hypothesize that using standard patient outcome measures, an improvement comparable with that expected for metal-backed tibial component TKA will be shown with All-polyethylene tibial component TKA.

Methods

Between August 2006 and August 2008, 229 all-polyethylene tibial component TKA were implanted at the elective orthopedic unit. The choice of implant was entirely dependent on surgeon's preference.

Of the 229 patient's, 225 details were available for review, 27 did not wish to take part in the study and 1 patient died a year following surgery of an unrelated illness. The remaining 197 patients agreed to take part in the study.

The patient's were contacted either in person or over the telephone and asked to completed questionnaires for standard knee scoring.

These included: the Oxford Knee Score (OKS), the WOMAC Score and the SF-12 Score, both pre-operatively and post operatively.