Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 51 - 51
1 Jan 2016
Cho YJ Chun YS Rhyu KH Hur D Liang H
Full Access

Purpose

Short metaphyseal fitting femoral stems convey stress to proximal femur and have no distal fixation. They have advantages in that there is no thigh pain and no bone loss due to stress shielding, but there is a concern for weakened fixation. So the authors evaluated whether short metaphyseal fitting femoral stems, which have only metaphyseal and no diaphyseal fixation, can acquire sufficient stability.

Materials & methods

39 cases of 36 patients who undervent uncemented total hip arthroplasty with DePuy ProximaTM (Johnson & Johnson orthopaedics, New Milton, UK) short metaphyseal fitting femoral stems from August 2009 to September 2011 were retrospectively evaluated. There were 19 male and 20 female cases. The mean follow-up period was 35.8(21.8∼49.2) months. Harris hip scores, WOMAC scores, UCLA scores, and presence of femoral pain were evaluated to assess clinical outcome. Femoral radiolucency in coronal and sagittal views of the hip, femoral stem loosening, and displacement was measured to evaluate radiological outcome. Distance between femoral stem and cortical bone was also measured to assess the relationship with radiolucency and loosening according to degree of contact.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 76 - 76
1 Jan 2016
Cho YJ Hur D Chun YS Rhyu KH
Full Access

Purpose

Cementless cup with structural allograft is one of option for acetabular revision in the cases which has severe bone loss. This study was performed to verify that the structural allograft with cementless cup could be one of good options for revision of acetabular cup with severe bone defect and to verify that the allograft resorption affect the stability of cementless acetabular cup.

Materials and Methods

We reviewed 25 cases of 25 patients who underwent acetabular cup rvision using cementless porous coated hemispherical cup with structural allograft from May 1992 to July 2011 July 2011. There were nine males and sixteen females with an average age of 50.0 years. The average follow-up period was 76.7(28∼212) months. The clinical evaluation was performed using Harris Hip Score(HHS) and UCLA activity score. Radiologically, the degree of resorption of grafted bone, incorporation of allograft bone with normal bone, osteolysis and cup loosening were evaluated.