ACETABULAR CUP REVISION USING CEMENTLESS CUP WITH STRUCTURAL ALLOGRAFT

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 1.



Abstract

Purpose

Cementless cup with structural allograft is one of option for acetabular revision in the cases which has severe bone loss. This study was performed to verify that the structural allograft with cementless cup could be one of good options for revision of acetabular cup with severe bone defect and to verify that the allograft resorption affect the stability of cementless acetabular cup.

Materials and Methods

We reviewed 25 cases of 25 patients who underwent acetabular cup rvision using cementless porous coated hemispherical cup with structural allograft from May 1992 to July 2011 July 2011. There were nine males and sixteen females with an average age of 50.0 years. The average follow-up period was 76.7(28∼212) months. The clinical evaluation was performed using Harris Hip Score(HHS) and UCLA activity score. Radiologically, the degree of resorption of grafted bone, incorporation of allograft bone with normal bone, osteolysis and cup loosening were evaluated.

Results

Clinically, the average Harris hip score was improved from 54 preoperatively to 93.4 at the last follow-up. The average UCLA activity score was also improved from 4.3 preoperatively to 6.4 at the last follow-up. Radiologically, the incorporation of allograft was accomplished in 11.4 months and the resorption of grafted bone was noted in 3 cases(12%), but the allograft resorption had not progressed to moderate degree even in long term follow-up. There was no cup loosening and average survivor rate was 100% in 6 years. There was no infection, allograft nonunion, osteolysis.

Conclusion

Cementless cup with structural allograft in acetabular cup reconstruction can provide excellent mi-term results in both clinical and radiological aspects. Structural allograft can provide strong mechanical support for the bone ingrowth of cementless cup. The clinical result of this study auggest that cementless cup with structural allograft can be a good option for acetabular cup revision with severe bone defect. Resorption of structural allograft rarely occurred, and the resorption of structural allograft does not affect stablility of cup even in long term follow-up.