The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.Aims
Methods
The Coronal Plane Alignment of the Knee (CPAK) classification has been developed to predict individual variations in inherent knee alignment. The impact of preoperative and postoperative CPAK classification phenotype on the postoperative clinical outcomes of total knee arthroplasty (TKA) remains elusive. This study aimed to examine the effect of postoperative CPAK classification phenotypes (I to IX), and their pre- to postoperative changes on patient-reported outcome measures (PROMs). A questionnaire was administered to 340 patients (422 knees) who underwent primary TKA for osteoarthritis (OA) between September 2013 and June 2019. A total of 231 patients (284 knees) responded. The Knee Society Score 2011 (KSS 2011), Knee injury and Osteoarthritis Outcome Score-12 (KOOS-12), and Forgotten Joint Score-12 (FJS-12) were used to assess clinical outcomes. Using preoperative and postoperative anteroposterior full-leg radiographs, the arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) were calculated and classified based on the CPAK classification. To investigate the impact on PROMs, multivariable regression analyses using stepwise selection were conducted, considering factors such as age at surgery, time since surgery, BMI, sex, implant use, postoperative aHKA classification, JLO classification, and changes in aHKA and JLO classifications from preoperative to postoperative.Aims
Methods
Accurate cup placement in total hip arthroplasty (THA) for the patients with developmental dysplasia of the hip (DDH) is one of the challenges due to distinctive bone deformity. Robotic-arm assisted system have been developed to improve the accuracy of implant placement. This study aimed to compare the accuracy of robotic-arm assisted (Robo-THA), CT-based navigated (Navi-THA), and manual (M-THA) cup position and orientation in THA for DDH. A total of 285 patients (335 hips) including 202 M-THAs, 45 Navi-THAs, and 88 Robo-THA were analyzed. The choice of procedure followed the patient's preferences. Horizontal and vertical center of rotation (HCOR and VCOR) were measured for cup position, and radiographic inclination (RI) and anteversion (RA) were measured for cup orientation. The propensity score-matching was performed among three groups to compare the absolute error from the preoperative target position and angle. Navi-THA showed significantly smaller absolute errors than M-THA in RI (3.6° and 5.4°) and RA (3.8° and 6.0°), however, there were no significant differences between them in HCOR (2.5 mm and 3.0 mm) or VCOR (2.2 mm and 2.6 mm). In contrast, Robo-THA showed significantly smaller absolute errors of cup position than both M-THA and Navi-THA (HCOR: 1.7 mm and 2.9 mm, vs. M-THA, 1.6 mm and 2.5 mm vs. Navi-THA, VCOR:1.7 mm and 2.4 mm, vs. M-THA, 1.4 mm and 2.2 mm vs. Navi-THA). Robo-THA also showed significantly smaller absolute errors of cup orientation than both M-THA and Navi-THA (RI: 1.4° and 5.7°, vs. M-THA, 1.5° and 3.6°, vs. Navi-THA, RA: 1.9° and 5.8° vs. M-THA, 2.1° and 3.8° vs. Navi-THA). Robotic-arm assisted system showed more accurate cup position and orientation compared to manual and CT-based navigation in THA for DDH. CT-based navigation increased the accuracy of cup orientation compared to manual procedures, but not cup position.
Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA). Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction, VAS pain, Oxford hip score (OHS), and Forgotten joint score (FJS). The thresholds of favorable outcomes of FJS and OHS were obtained using the receiver-operating characteristic curve with VAS satisfaction ≥ 50 and VAS pain < 20 as anchors. Thirty-three hips (19.2%) underwent THA at average 13.3 years after TOA. Kaplan-Meier analysis revealed hip survival rate at 20 years was 79.7%. Multivariate analysis showed the preoperative Tönnis grade significantly influenced hip survival. Survival rates with Tönnis grade 0, grade 1, and grade 2 were 93.3%, 86.7%, and 54.8% at 20 years, respectively. More than 60% of the patients showed favorable PROMs (VAS satisfaction ≥ 50, VAS pain < 20, OHS ≥ 42, FJS ≥ 51). Advanced Tönnis grade at the latest follow-up and higher BMI were significantly associated with unfavorable OHS, but not with other PROMs. This study demonstrated the durability of TOA for hips with Tönnis grade 0–1 and favorable satisfaction in majority of the patients at 20 years after surgery. Current presence of advanced osteoarthritis is associated with the lower hip function (OHS), but not necessarily associated with subjective pain and satisfaction. Higher BMI also showed a negative impact on postoperative function.
Regaining the walking ability is one of the main purposes of total knee arthroplasty (TKA). Improving the activities of daily living is a key of patient satisfaction after TKA. However, some patients do not gain enough improvement of ADL as they preoperatively expected, and thus are not satisfied with the surgery. The purpose of this study is to clarify the relationship between preoperative and postoperative physical functional status and whether preoperative scoring can predict the postoperative walking ability. Consecutive 136 patients who underwent total knee arthroplasty for osteoarthritis were prospectively assessed. The average age (±SD) was 74±7.7 and 74% of the patients was female. Berg Balance Scale (BBS) was assessed preoperatively and one year after the surgery. The time needed for 10m walking, muscle power for knee extension and flexion, visual analog scale (VAS) for pain in walking, and necessity of canes in walking were also assessed at one year after the surgery. Multivariate correlation analysis was performed for each parameter. Speaman rank correlation coefficient revealed that preoperative BBS was significantly correlated with the time needed for 10m walking (ρ=0.66, p<0.001). Logistic regression analysis also revealed that preoperative BBS is also correlated with the necessity for canes in walking one year after the surgery. The cut-off value of preoperative BBS for the necessity of canes in walking by ROC curve analysis was 48 points with 79% in sensitivity and 80% in specificity. The muscle powers were also weakly correlated with the walking ability at one year after the surgery, but VAS for pain was not. The study indicated that preoperative physical balance could predict the ability of walking one year after TKA regardless of the reduction of pain. It is suggested that surgery should be recommended before the physical balance function deteriorates to achieve the better walking ability after the TKA
Similar to the radiological findings in rapidly destructive arthrosis of the hip joint (RDA), subchondral insufficiency fracture of the femoral head (SIF) can result in progressive femoral head collapse of unknown etiology. We thus examined the osteoclast activity in hip joint fluid in SIF with progressive collapse in comparison to that in RDA. Twenty-nine hip joint fluid samples were obtained intraoperatively with whole femoral heads from 12 SIF patients and 17 RDA patients. SIF cases were classified into subgroups based on the presence of ≥2mm collapse on preoperative radiographs: SIF with progressive collapse (n=5) and SIF without progressive collapse (n=7). The levels of tartrate-resistant acid phosphatase (TRACP)-5b, interleukin-8, vascular endothelial growth factor (VEGF), and matrix metalloproteinase (MMP)-9 were measured. Numbers of multinuclear giant cells at the subchondral region were assessed histopathologically using mid-coronal slices of each femoral head specimen. Median levels of all markers and median numbers of multinuclear giant cells in SIF with progressive collapse were significantly higher than those in SIF without progressive collapse, while there were no significant differences in SIF with progressive collapse versus RDA. Regression analysis showed that the number of multinuclear giant cells correlated positively with the level of TRACP-5b in joint fluid. This study suggests an association of increased osteoclast activity with the existing condition of progressive collapse in SIF, which was quite similar to the findings in RDA. Therefore, high activation of osteoclast cell may reflect the condition of progressive collapse in SIF as well as RDA.
Golf is considered low-impact sport, but concerns exist about whether golf swing can be performed in safe manner after THA. The purpose of this study was to clarify dynamic hip kinematics during golf swing after THA using image-matching techniques. This study group consisted of eight right-handed recreational golfers with 10 primary THAs. Each operation was performed using a posterolateral approach with combined anteversion technique. Nine of ten polyethylene liners used had elevated portion of 15°. Continuous radiographic images of five trail and five lead hips during golf swing were recorded using a flat panel X-ray detector (Fig. 1) and analyzed using image-matching techniques (Fig. 2). The relative distance between the center of cup and femoral head and the minimum liner-to-stem distance were measured using a CAD software program. The cup inclination, cup anteversion, and stem anteversion were measured in postoperative CT data. Hip kinematics, orientation of components, and cup-head distance were compared between patients with and without liner-to-stem contact by Mann-Whitney INTRODUCTION
METHODS
High tibial osteotomy (HTO) is a useful treatment option for osteoarthritis of the knee. Closing-wedge HTO (CW-HTO) had been mostly performed previously, but the difficulties of surgical procedure when total knee arthroplasty (TKA) conversion is needed are sometimes pointed out because of the severe deformity in proximal tibia. Recently, opening-wedge HTO (OW-HTO) is becoming more popular, but the difference of the two surgical techniques about the influence on proximal tibia deformity and difficulties in TKA conversion are not fully understood. The purpose of this study was to compare the influence of two surgical techniques with CW-HTO and OW-HTO on the tibial bone deformity using computer simulation and to assess the difficulties when TKA conversion should be required in the future. In forty knees with medial osteoarthritis, the 3D bone models were created from the series of 1 mm slices two-dimensional contours using the 3D reconstruction algorithm. The 3-D imaging software (Mimics, materialize NV, Leuven, Belgium) was applied and simulated surgical procedure of each CW-HTO and OW-HTO were performed on the same knee models. In CWHTO, insertion level was set 2cm below the medial joint line [Fig.1]. While in OW-HTO, that was set 3.5cm below the medial joint line and passed obliquely towards the tip of the fibular head [Fig.2]. The correction angle was determined so that the postoperative tibiofemoral angle would be 170 degrees. The distance between the center of resection surface and anatomical axis, and the angle of anatomical axis and mechanical axis were measured in each procedure. Secondly, a simulated TKA conversion was operated on the each tibial bone models after HTO [Fig.3]. The distance between the nearest points of tibial implant and lateral cortical bone was assessed as the index of the bone-implant interference.«Purpose»
«Methods»
Adjusting the joint gap length to be equal in both extension and flexion is an important issue in total knee arthroplasty (TKA). Tight flexion gaps occur sometimes, particularly with the cruciate-retaining (CR) type of TKA, and it impede knee flexion. In posterior stabilizing (PS) TKA, because sacrificing the PCL increases the flexion gap, the issue of gap balancing with PS-TKA is usually focused on decreasing the enlarged flexion gap to be equal to the extension gap. It is generally known that posterior tibial slope would affect the flexion gap, however, the extent to which changes in the tibial slope angle directly affect the flexion gap remains unclear. This study aimed to clarify the influence of tibial slope changes on the flexion gap in CR- or PS-TKA. The flexion gap was measured using a tensor device with the femoral trail component in 20 cases each of CR- and PS-TKA. A wedge plate with a 5° inclination was placed on the tibial cut surface by switching its front–back direction to increase or decrease the tibial slope by 5°. The flexion gap in changing the tibial slope was compared to that of the neutral slope measured with a flat plate that had the same thickness of the wedge plate center.Background
Methods
Controversy still exists as to whether total knee arthroplasty (TKA) provides reproducible knee kinematics during activities. In this study, we evaluated the A total of twenty four knees in nineteen patients following cruciate-retaining (CR) or posterior-stabilized (PS) TKA were randomly included in the study. The twenty-four knees included 22 female knees and 2 male knees in patients aged 73 years. The pre-operative diagnosis was osteoarthritis in 22 knees and rheumatoid arthritis in 2 knees. The average follow-up period after surgery was 29 months, and average post-operative knee extension/flexion angle was 2°/121°. The average knee score was 93 and the average functional score was 77. Continuous sagittal radiological images were obtained during stair-climbing for each patient using a large flat panel detector. Anteroposterior (AP) tibiofemoral position, implant flexion, and axial rotation angles were determined in three dimensions using a 3D-to-2D model-to-image registration technique. In CR TKA, the minimum distances between the femoral trochlea and the intercondylar eminence of the tibial insert were measured using a CAD software program. In PS TKA, the minimum distances between the femoral cam and the posterior aspect of the tibial post and between the femoral trochlea and the anterior aspect of the tibial post were measured.Introduction
Patients and Methods
3D-to-2D model registration technique has been used for evaluating 3D kinematics from 3D surface models of the prostheses or bones and radiographic image sequences. However, no studies have employed these techniques to evaluate Dynamic hip kinematics during gait, squatting, chair-rising, and twisting were analyzed for six healthy subjects and eleven patients with osteoarthritis (OA). Continuous anteroposterior radiographic images were recorded using a flat panel X-ray detector Introduction
Measurement
Using the tibial extramedullary guide needs meticulous attention to accurately align the tray in total knee arthroplasty (TKA). We previously reported the risk for varus tray alignment if the anteroposterior (AP) axis of the ankle was used for the rotational direction of the guide. The purpose of our study was to determine whether aligning the rotational direction of the guide to the AP axis of the proximal tibia reduced the incidence of varus tray alignment when compared to aligning the rotational direction of the guide to the AP axis of the ankle.Introduction
Materials and Methods
Radiographs and computed tomography (CT) images are used for the preoperative planning in total knee arthroplasty (TKA), however, these two-dimensional (2D) measurements are affected easily by limb position and scanning direction relative to three-dimensional (3D) bone model analyses. The purpose of our study was to compare these measurements to evaluate the factors affecting the difference. A total of 75 osteoarthritis knees before primary TKA were assessed. The full-length weight-bearing anteroposterior radiograph and CT slices were used for the 2D measurement. Three-dimensional measurement used 3D bone model reconstructed from the CT data and the coordinate system as the previous reports (Figure 1). We measured FVA (femoral valgus angle), CRA (the angle between the posterior condylar line <PC-L> and the clinical epicondylar axis <CEA>), and SRA (the angle between the PC-L and the surgical epicondylar axis <SEA>). Intra- and inter-observer reliabilities were assessed by intraclass correlation coefficients (ICC), and the differences between the 2D and the 3D measurements (Differences) were evaluated. In addition, we evaluated whether preoperative factors (preoperative extension angle, HKA, BMI and CT scanning direction) affected the differences between the 3D and the 2D measurements. Computer simulation was used to examine the influences of CT scanning direction.Introduction
Patients and Methods
Because there have been no standard methods to determine pre-operatively
the thickness of resection of the proximal tibia in unicompartmental
knee arthroplasty (UKA), information about the relationship between
the change of limb alignment and the joint line elevation would
be useful for pre-operative planning. The purpose of this study
was to clarify the correlation between the change of limb alignment
and the change of joint line height at the medial compartment after
UKA. A consecutive series of 42 medial UKAs was reviewed retrospectively.
These patients were assessed radiographically both pre- and post-operatively
with standing anteroposterior radiographs. The thickness of bone
resection at the proximal tibia and the distal femur was measured
radiographically. The relationship between the change of femorotibial
angle (δFTA) and the change of joint line height, was analysed.Objectives
Methods