Persistent medial laxity increases the risk of failure for ACL reconstruction. To address this, multiple reconstruction techniques have been created. To date, no single strand reconstruction constructs have been able to restore both valgus and rotational stability. In response to this, a novel single strand Short Isometric Construct (SIC) MCL reconstruction was developed. Eight fresh-frozen cadaveric specimens were tested in three states: 1) intact 2) after sMCL and dMCL transection, and 3) after SIC MCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 90N anterior drawer, 5Nm tibial external rotation torque, 8Nm valgus torque, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.Abstract
Introduction
Methods
Historic MCL reconstruction techniques focused on the superficial MCL to restore valgus stability while overlooking tibial external rotation and the deep MCL. This study assessed the ability of a contemporary medial collateral ligament (MCL) reconstruction and a deep MCL (dMCL) reconstruction to restore rotational and valgus knee stability. Six pairs fresh-frozen cadaveric knee specimens with intact soft tissue were tested in four states: 1) intact 2) after sMCL and dMCL sectioning, 3) contemporary MCL reconstruction (LaPrade et al), and 4) dMCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 8Nm valgus torque, 5Nm tibial external rotation torque, 90N anterior drawer, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.Abstract
Introduction
Methods
Stable fixation of cementless tibial trays remains a challenge due bone density variability within the proximal tibia and the spectrum of loads imposed by different activities. This study presents a novel approach to measuring the interface motion of cementless tibial components during functional loading and tests whether interface motion of cementless tibial trays varies around the implant periphery. We developed a method to measure relative displacement of a tibial tray relative to the underlying bone using 3D digital image correlation (DIC) and multi-camera stereo photogrammetry. A clinically successful design of cementless total knee prosthesis (Zimmer Inc, Warsaw, IN) was implanted in 6 fresh cadaveric knees. A black-on-white stochastic pattern was applied to the outer surface of the tibia and the cementless prosthesis. High resolution digital images were prepared of the interface region and divided into 25 × 25 pixel regions of interest (ROI). Stereo images of the same ROI were generated using two cameras angled at 60 degrees using image correlation techniques. All specimens were mounted in a custom-built functional activity simulator and loaded with the forces and moments recorded during three common functional activities (standing from a seated position, walking, and stair descent), as reported in the Orthoload database, scaled by 50% for application to cadaveric bone. Prior to functional testing, each implant-tibia construct was preconditioned with 500 cycles of flexion from 5–100 degrees under a vertical tibial load of 1050 N at a frequency of 0.2 Hz. During loading, image data was acquired simultaneously (±20 μs) from the entire circumference of the tibial interface forming 4 stereo images using 8 cameras spaced at 90 degree intervals (Allied Vision Technologies, Exton, PA) using custom image acquisition software (Mathworks, Natick, MA) (Figure 1). The multiple stereo images were registered using the surface topography of each specimen as measured by laser scanning (FARO Inc., Montreal) (Figure 2). During post-processing, the circumferential tray/tibia interface was divided into 10 zones for subsequent analysis (Figure 3). Interface displacements were measured on a point-to-point basis at approximately 700 sites on each specimen using commercial DIC software (Dantec Dynamics, Skovlunde, Denmark) (Figure 4).INTRODUCTION
METHODS
Cementless tibial trays commonly fail through failure of fixation due to excessive interface motion. However, the specific combination of axial and shear forces precipitating implant failure is unknown. This has led to generic loading profiles approximating walking to perform pre-clinical assessment of new designs, even though telemetric data demonstrates that much larger forces and moments are generated during other functional activities. This study was undertaken to test the hypotheses: (i) interface motion of cementless tibial trays varies as a function of specific activities, and (ii) the response of the cementless tibial interface to walking loading is not representative of other functional activities. Six fresh-frozen cadaveric tibias were tested using a custom designed functional activity simulator after implantation of a posterior stabilized total knee replacement (NexGen LPS, Zimmer, Warsaw IN). Activity scenarios were selected using force (Fx, Fy, Fz) and moment (Mx, My, Mz) data from patients with instrumented tibial trays (E-tibia) published by Bergmann et al. A pattern of black and white spray paint was applied to the surface of the specimen including the tibial tray and bone. Each specimen was preconditioned through application of a vertical load of 1050N for 500 cycles of flexion-extension from 5–100°. Following preconditioning, each tibia was loaded using e-tibia values of forces and moments for walking, stair-descent, and sit-to-stand activities. The differential motion of the tibial tray and the adjacent bony surface was monitored using digital image correlation (DIC) (resolution: 1–2 microns in plane; 3–4 microns out-of-plane). Four pairs of stereo-images of the tray and tibial bone were prepared at sites around the circumference of the construct in both the loaded and unloaded conditions: (i) before and after pre-conditioning and (ii) before and after the 6 functional loading profiles. The images were processed to provide circumferential measurements of interface motion during loading. Differences in micromotion and migration were evaluated statistically using step-wise multivariate regression.INTRODUCTION
MATERIALS and METHODS
Numerous factors have been hypothesized as contributing to mechanically-assisted corrosion at the head-neck junction of total hip prostheses. While variables attributable to the implant and the patient are amenable to investigation, parameters describing assembly of the component parts can be difficult to determine. Nonetheless, increasing evidence suggests that the manner of intraoperative assembly of modular components plays a critical role in the fretting and corrosion of modular implants. This study was undertaken to measure the magnitude and direction of the impaction forces applied by surgeons in assembling modular head-neck junctions under operative conditions where both the access and visibility of the prosthesis may potentially compromise component fixation. A surrogate consisting of the lower limb with overlying soft tissue was developed to simulate THR performed via a 10cm incision using the posterior approach. The surrogate was modified to match the resistance of the body to retraction of the incision, mobilization of the femur and hammering of the implanted femoral component. An instrumented femoral stem (SL PLUS) was surgically implanted into the bone after attachment of 3 miniature accelerometers (Dytran Inc) in an orthogonal array to the proximal surface of the prosthesis. A 32mm cobalt chrome femoral head was mounted on the trunnion (12/14 taper, machined) of the femoral stem. 15 Board-certified and trainee surgeons replicated their surgical technique in exposing the femur and impacting the modular head on the tapered trunnion. Impaction was performed using an instrumented hammer (5000 Lbf Dytran impact hammer) that provided measurements of the magnitude and temporal variation of the impact force. The components of force acting along the axis aof the neck and in the AP and ML directions were continuously samples using the accelerometers.Introduction
Methods
Mechanically-assisted corrosion of the head-neck junction present a dilemma to surgeons at revision THR whenever the femoral component is rigidly fixed to the femur. Many remove the damaged femoral head, clean the femoral taper and fix a new head in place to spare the patient the risks associated with extraction and replacement of the well-functioning femoral stem. This study was performed to answer these research questions:
Will new metal heads restore the mechanical integrity of the original modular junction after impaction on corroded tapers? Which variables affect the stability of the new interface created at revision THR? Twenty-two tapers (CoCr, n=12; TiAlV, n=10) were obtained for use in this study. Ten stems were in pristine condition, while 12 stems had been retrieved at revision THR and with corrosion damage to the trunnion (Goldberg scale 4). Twenty-two new metal heads were obtained for use in the study, each matching the taper and manufacturer of the original component. The following test states were performed using a MTS Machine: 1. Assembly, 2. Disassembly, 3. Assembly, 4. Toggling and 5. Disassembly. All head assemblies were performed wet using 50% calf serum in accordance to ISO 7206-10. During toggling, each specimen's loading axis was aligned 25° to the trunnion axis in the frontal plane and 10° in the sagittal plane (Figure 1). Toggling was performed at 1Hz for 2,000 cycles with a sinusoidal loading function (230N–4300N). During loading, 3D motion of the head-trunnion junction was measured using a custom jig rigidly attached to the head and the neck of each prosthesis. Relative displacement of the head with respect to the neck was continuously monitored using 6 high resolution displacement transducers with an accuracy of ±0.6µm. Displacement data was independently validated using FEA models of selected constructs.Introduction
Materials and Methods
Manifestation of high interface stresses coupled with micromotion at the interface can render the taper lock joint in a modular hip replacement prosthesis at risk for failure. Bending can lead to crevice formation between the trunnion and the head and can potentially expose the interface to the biological fluids, generating interface corrosion. Additionally, development of high stresses can cause the material to yield, ultimately leading to irreversible damage to the implant. The objective of this study is to elucidate the mechanical response of taper junction in different material combination assemblies, under the maximum loads applied during everyday activities. Computer simulations were executed using a verified FE model. A stable hexahedral mesh (33648 elements) was generated for the trunnion (taper size: 12/14mm) and a tetrahedral mesh (51182 elements) for the head (CoCr, size: 32mm). An assembly load of 4000N was applied along the trunnion axis followed by the application of a load of 230–4300N at 25° and 10° angle to the trunnion axis in the frontal and sagittal planes. A linear static solution was set up using Siemens NX Nastran. Two material combinations were tested - cobalt-chrome head with a titanium alloy trunnion and cobalt chrome head with a cobalt-chrome trunnion.Introduction
Methods
Knee pain and instability during high demand activities such as stair descent are reported by patients after TKA. Previous studies theorized that this pain is from increased demand on the quadriceps required to stabilize the femur on the tibia. In this study we explore the relationship between implant design, the posterior cruciate ligament (PCL), and AP stability of the knee during stair descent. CTs of 6 fresh-frozen human cadaveric knees (average age: 61 ± 6.5 years) with functioning cruciates were prepared. All specimens were mounted in a computer controlled, 6 DOF simulator programed to apply physiologic muscle loads and flexion/extension moments simulating the highest demand phase of stair descent (terminal swing to initial contact). A contemporary design of TKA was implanted in each specimen by an experienced surgeon. Testing was repeated after implantation of tibial inserts of the CR, CS with and without a PCL and PS designs.Purpose:
Methods:
Malrotation of the tibial component is a common error in TKR, and has been frequently cited as the cause of clinical symptoms. Correct rotational orientation of the tibial tray is difficult to achieve because the resected surface of the tibia is internally rotated and is not symmetrical in shape. This suggests that anatomically contoured components may lead to improved rotational positioning. This study was undertaken to test the hypotheses:
Use of an anatomically shaped tibial tray can reduce the prevalence of malrotation and cortical over-hang in TKA while increasing coverage of the resected tibial surface, and Component shape has more influence on the results of surgical trainees compared to experienced surgeons. A standard symmetric design of tibial tray was developed from the profiles of 3 widely used contemporary trays. Corresponding asymmetric profiles were generated to match the average shape of the resected surface of the tibia based on a detailed morphometric analysis of anatomic data. Both designs were proportionally scaled to generate a set of 7 different sizes. Computer models of eight tibias were selected from a large anatomic collection. The proximal tibia was resected perpendicular to the canal axis with a posterior slope of 5 degrees at a depth of 5 mm (medial). Eleven experienced joint surgeons and twelve trainees individually determined the ideal size and placement of each tray on each of the 8 resected tibias. The rotational alignment, coverage of the resected bony surface, and extent of overhang of the tray beyond the cortical boundary were measured for each implantation. Differences in the parameters defining the implantations of the surgeons and trainees were evaluated statistically.Introduction:
Materials and Methods:
A disturbing prevalence of painful inflammatory reactions has been reported in metal-on-metal (MoM) hip resurfacing arthroplasty. A contributing factor is localized loading of the acetabular shell leading to “edge wear” which is often seen after precise measurement of the bearing surfaces of retrieved components. Factors contributing to edge wear include adverse cup orientation leading to proximity (<10 mm) of the hip reaction force to the edge of the acetabular component. As this phenomenon is a function of implant positioning and patient posture, this study was performed to investigate the occurrence of edge loading during different functional activities as a function of cup inclination and version. We developed a computer model of the hip joint through reconstruction of CT scans of a proto-typical pelvis and femur and virtually implanting a hip resurfacing prosthesis in an ideal position. Using this model, we examined the relationship between the resultant hip force vector and the edge of the acetabular shell during walking, stair ascent and descent, and getting in and out of a chair. Load data was derived from 5 THR patients implanted with instrumented hip prostheses (Bergmann et al). We calculated the distance from the edge of the shell to the point of intersection of the load vector and the bearing surface for cup orientations ranging from 40 to 70 degrees of inclination, and 0 to 40 degrees of anteversion.Introduction:
Methods:
Despite all the attention to new technologies and sophisticated implant designs, imperfect surgical technique remains a obstacle to improving the results of total knee replacement (TKR). On the tibial side, common errors which are known to contribute to post-operative instability and reduced function include internal rotation of the tibial tray, inadequate posterior slope, and excessive component varus or valgus. However, the prevalence of each error in surgeries performed by surgeons and trainees is unknown. The following study was undertaken to determine which of these errors occurs most frequently in trainees acquiring the surgical skills to perform TKR. A total of 43 knee replacement procedures were performed by 11 surgical trainees (surgical students, residents and fellows) in a computerized training center. After initial instruction, each trainee performed a series of four TKR procedures in cadavers (n = 2) and bone replicas (n = 2) using a contemporary TKR instrument set and the assistance of an experienced surgical instructor. Prior to each procedure, computer models of each cadaver and/or bone replica tibia were prepared by reconstructing CT scans of each specimen. All training procedures were performed in a navigated operating room using a 12 camera motion analysis system (Motion Analysis Inc.) with a spatial resolution in all three orthogonal directions of ± 0.15 mm. The natural slope, varus/valgus alignment, and axial rotation of the proximal tibial surface were recorded prior to surgery and after placement of the tibial component. For evaluation of all data, acceptable limits for implantation were defined as: posterior slope: 0–10°; varus/valgus inclination of tibial resection: ± 3°; and external rotation: 0–10°.Introduction:
Materials and Methods:
A disturbing prevalence of short-term failures of metal-on-metal (MoM) hip resurfacings has been reported by joint registries. These cases have been primarily due to painful inflammatory reactions and, in extreme cases, formation of pseudotumors within periarticular soft-tissues. The likely cause is localized loading of the acetabular shell leading to “edge wear” which is often seen after precise measurement of the bearing surfaces of retrieved components. Factors contributing to edge wear of metal-on-metal arthroplasties are thought to include adverse cup orientation, patient posture, and the direction of hip loading. The purpose of this study was to investigate the role of different functional activities in edge loading of hip resurfacing prostheses as a function of cup inclination and version. We developed a computer model of the hip joint through reconstruction of CT scans of a proto-typical pelvis and femur and virtually implanting a hip resurfacing prosthesis in an ideal position. Using this model, we examined the relationship between the resultant hip force vector and the edge of the acetabular shell during walking, stair ascent and descent, and getting in and out of a chair. Load data was derived from 5 THR patients implanted with instrumented hip prostheses (Bergmann et al). We calculated the distance from the edge of the shell to the point of intersection of the load vector and the bearing surface for cup orientations ranging from 40 to 70 degrees of inclination, and 0 to 40 degrees of anteversion.Introduction
Methods
Although the “learning curve” in surgical procedures is well recognized, little data exists documenting the accuracy of surgeons in performing individual steps of orthopedic procedures. In this study we have used a validated computer-based training system to measure variations instrument placement and alignment in TKA, specifically those relating to tibial preparation. Eleven trainees (surgical students, residents and fellows) were recruited to perform a series of 43 knee replacement procedures in a computerized training center. After initial instruction, each trainee performed a series of four TKA procedures in cadavers (n=2) and bone replicas (n=2) using a contemporary TKA instrument set and the assistance of an experienced surgical instructor. The Computerized Bioskills system was utilized to monitor the placement and orientation of the proximal tibial osteotomy and the tibial tray.Introduction
Methods