In Two-Stage Revision, utilizing temporary antibiotic spacers is widely accepted. These spacers are available prefabricated or can be individually moulded intraoperatively. In this study, we analysed the efficacy of prefabricated and individual spacers in infection eradication of periprosthetic joint infection in knee and hip arthroplasties. All spacers implanted at a tertiary academic center during two-stage exchanges between June 2010 and December 2019 were retrospectively analysed. Among 249 patients, 167 cases (minimum follow-up ≥ 12 months) were included. Commercial spacers contained vancomycin and gentamycin, while individual spacers contained vancomycin alone. Subgroup analysis by manufacturers was conducted using non-parametric methods including Mann-Whitney U and Kruskal-Wallis tests. Survival analysis utilized Kaplan-Meier curves, and categorical data were analyzed using the Chi² test. Statistical significance was defined as p < 0.05.Aim
Method
The diagnosis of prosthetic joint infection (PJI) is challenging and relies on a combination of parameters. However, the currently recommended diagnostic algorithms have not been validated for patients with recent surgery, dislocation or other events associated with a local inflammatory response. As a result, these algorithms are not safely applicable offhand in such conditions. Calprotectin is a leukocyte protein that has been shown to be a reliable biomarker of PJI. The purpose of this study was to evaluate the use of calprotectin to rule out PJI within 3 months after surgery or dislocation. We included patients who underwent arthroplasty revision surgery at our institution within 3 months after any event causing inflammation. Calprotectin was measured using a lateral-flow assay. European Bone and Joint Infection Society (EBJIS) criteria were used as gold standard. The diagnostic accuracy of calprotectin was calculated.Aim
Method
Despite the high regenerative capacity of bone, large bone defects often require treatment involving bone grafts. Conventional autografting and allografting treatments have disadvantages, such as donor site morbidity, immunogenicity and lack of donor material. Bone tissue engineering offers the potential to achieve major advances in the development of alternative bone grafts by exploiting the bone-forming capacity of osteoblastic cells. However, viable cell culture models are essential to investigate osteoblast behavior. Three-dimensional (3D) cell culture systems have become increasingly popular because biological relevance of 3D cultures may exceed that of cell monolayers (2D) grown in standard tissue culture. However, only few direct comparisons between 2D and 3D models have been published. Therefore, we performed a pilot study comparing 2D and 3D culture models of primary human osteoblasts with regard to expression of transcription factors RUNX2 and osterix as well as osteogenic differentiation. Primary human osteoblasts were extracted from femoral neck spongy bone obtained during surgery procedures. Primary human osteoblasts of three donor patients were cultured in monolayers and in three different 3D culture models: 1) scaffold-free cultures, also referred to as histoids, which form autonomously after multilayer release of an osteoblast culture; 2) short-term (10-day) collagen scaffolds seeded with primary human osteoblasts (HOB); 3) long-term (29-day) collagen scaffolds seeded with HOB. Expression levels of transcription factors RUNX2 and osterix, both involved in osteoblast differentiation, were investigated using quantitative PCR and immunohistochemical staining. Furthermore, markers of osteogenic differentiation were evaluated, such as alkaline phosphatase activity, osteocalcin expression, and mineral deposition, as well as the expression of collagen type I and fibronectin extracellular matrix proteins.Introduction
Patients and Methods