Fast and accurate identification of pathogens causing periprosthetic joint infections (PJI) is essential to initiate effective antimicrobial treatment. Culture-based approaches frequently yield false negative results, despite clear signs of infection. This may be due to the use of general growth media, which do not mimic the conditions at site of infection. Possible alternative approaches include DNA-based techniques, the use of In this study, 120 synovial fluid samples were included, aspirated from patients with clinical signs of PJI. For these samples microbiology data (obtained in the clinical microbiology lab using standard procedures) and next generation sequencing (NGS) data, were available. The samples were incubated in the SSF medium at different oxygen levels (21% O2, 3% O2 and 0% O2) for 10 days. Every 24h, the presence of growth was checked. From positive samples, cultures were purified on Columbia blood agar and identified using MALDI-TOF. In parallel, heat produced by metabolically active microorganisms present in the samples was measured using ITC (calScreener, Symcel), (96h at 37°C, in SSF, BHI and thioglycolate). From the resulting thermograms the ‘time to activity’ could be derived. The accuracy and time to detection were compared between the different detection methods.Aim
Methods
Machine-learning (ML) prediction models in orthopaedic trauma hold great promise in assisting clinicians in various tasks, such as personalized risk stratification. However, an overview of current applications and critical appraisal to peer-reviewed guidelines is lacking. The objectives of this study are to 1) provide an overview of current ML prediction models in orthopaedic trauma; 2) evaluate the completeness of reporting following the Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) statement; and 3) assess the risk of bias following the Prediction model Risk Of Bias Assessment Tool (PROBAST) tool. A systematic search screening 3,252 studies identified 45 ML-based prediction models in orthopaedic trauma up to January 2023. The TRIPOD statement assessed transparent reporting and the PROBAST tool the risk of bias.Aims
Methods
There is growing evidence that bacteria encountered in periprosthetic joint infections (PJI) form surface-attached biofilms on prostheses, as well as biofilm aggregates embedded in synovial fluid and tissues. However, models allowing the investigation of these biofilms and the assessment of their antimicrobial susceptibility in physiologically relevant conditions are currently lacking. To address this, we developed a synthetic synovial fluid (SSF) model and we validated this model in terms of growth, aggregate formation and antimicrobial susceptibility testing, using multiple PJI isolates. 17 PJI isolates were included, belonging to Aim
Methods
The computational modelling and 3D technology are finding more and more applications in the medical field. Orthopedic surgery is one of the specialties that can benefit the most from this solution. Three case reports drawn from the experience of the authors’ Orthopedic Clinic are illustraded to highlight the benefits of applying this technology. Drawing on the extensive experience gained within the authors’ Operating Unit, three cases regarding different body segments have been selected to prove the importance of 3D technology in preoperative planning and during the surgery. A sternal transplant by allograft from a cryopreserved cadaver, the realization of a custom made implant of the glenoid component in a two-stage revision of a reverse shoulder arthroplasty, and a case of revision on a hip prosthesis with acetabular bone loss (Paprosky 3B) treated with custom system. In all cases the surgery was planned using 3D processing software and models of the affected bone segments, printed by 3D printer, and based on CT scans of the patients. The surgical implant was managed with dedicated instruments. The use of 3D technology can improve the results of orthopedic surgery in many ways: by optimizing the outcomes of the operation as it allows a preliminary study of the bone loss and an evalutation of feasibility of the surgery, it improves the precision of the positioning of the implant, especially in the context of severe deformity and bone loss, and it reduces the operating time; by improving surgeon training; by increasing patient involvement in decision making and informed consent. 3D technology, by offering targeted and customized solutions, is a valid tool to obtain the tailored care that every patient needs and deserves, also providing the surgeon with an important help in cases of great complexity.
In a clinical setting, there is a need for simple gait kinematic measurements to facilitate objective unobtrusive patient monitoring. The objective of this study is to determine if a learned classification model's output can be used to monitor a person's recovery status post-TKA. The gait kinematics of 20 asymptomatic and 17 people with TKA were measured using a full-body Xsens model1. The experimental group was measured at 6 weeks, 3, 6, and 12 months post-surgery. Joint angles of the ankle, knee, hip, and spine per stride (10 strides) were extracted from the Xsens software (MVN Awinda studio 4.4)1. Statistical features for each subject at each evaluation moment were derived from the kinematic time-series data. We normalised the features using standard scaling2. We trained a logistic regression (LR) model using L1-regularisation on the 6 weeks post-surgery data2–4. After training, we applied the trained LR- model to the normalised features computed for the subsequent timepoints. The model returns a score between 0 (100% confident the person is an asymptomatic control) and 1 (100% confident this person is a patient). The decision boundary is set at 0.5. The classification accuracy of our LR-model was 94.58%. Our population's probability of belonging to the patient class decreases over time. At 12 months post-TKA, 38% of our patients were classified as asymptomatic.
To develop prediction models using machine-learning (ML) algorithms for 90-day and one-year mortality prediction in femoral neck fracture (FNF) patients aged 50 years or older based on the Hip fracture Evaluation with Alternatives of Total Hip arthroplasty versus Hemiarthroplasty (HEALTH) and Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trials. This study included 2,388 patients from the HEALTH and FAITH trials, with 90-day and one-year mortality proportions of 3.0% (71/2,388) and 6.4% (153/2,388), respectively. The mean age was 75.9 years (SD 10.8) and 65.9% of patients (1,574/2,388) were female. The algorithms included patient and injury characteristics. Six algorithms were developed, internally validated and evaluated across discrimination (c-statistic; discriminative ability between those with risk of mortality and those without), calibration (observed outcome compared to the predicted probability), and the Brier score (composite of discrimination and calibration).Aims
Methods
Several factors contribute to the duration of the hospital stay in patients that undergo to total hip arthroplasty (THA), either subjective or perioperative. However, no definite evidence has been provided on the role of any of these factors on the hospitalization length. The aim of this retrospective investigation is to evaluate the correlation between several preoperative and perioperative factors and the length of hospital stay (LOS) in patients that underwent elective total hip arthroplasty. Medical records of patients that underwent THA since the beginning of 2016 to the end of 2018 were retrospectively screened. Demographics, comorbidities, renal function, whole blood count. and length of post-operative ward stay were retrieved. The association between clinical, biochemical and surgical factors and the length of hospital stay was explored by means of linear regression models.Introduction and Objective
Materials and Methods
Patients with FNF may be treated by either total hip arthroplasty (THA) or hemiarthroplasty (HA). Utilizing American Joint Replacement Registry (AJRR) data, we aimed to evaluate outcomes in FNF treatment. Medicare patients with FNF treated with HA or THA reported to the AJRR database from 2012–2019 and CMS claims data from 2012–2017 were analyzed in this retrospective cohort study. “Early” was defined as less than 90 days from index procedure. A logistic regression model, including index arthroplasty, age, sex, stem fixation method, hospital size1, hospital teaching affiliation1, and Charlson comorbidity index (CCI), was utilized to determine associations between index procedure and revision rates.Introduction
Methods
Cellular therapies play an important role in tendon tissue engineering with tenocytes being described as the most prominent cell population if available in large numbers. However, in vitro expansion of tenocytes in standard culture leads to phenotypic drift and cellular senescence. Recent work suggests that maintenance of tenogenic phenotype in vitro can be achieved by recapitulating different aspects of the native tendon microenvironment. One approach used to modulate the in vitro microenvironment and enhance extracellular matrix (ECM) deposition is macromolecular crowding (MMC). MMC is based on the addition of inert macromolecules to the culture media mimicking the dense extracellular matrix. In addition, as tendon has been described to be a relatively avascular and hypoxic tissue and low oxygen tension can stimulate collagen synthesis and cross-linking, we venture to assess the synergistic effect of MMC and low oxygen tension on human tenocyte phenotype maintenance by enhancing synthesis and deposition of tissue-specific ECM. Human tendons were kindly provided from University Hospital Galway, after obtaining appropriate licenses, ethical approvals and patient consent. Afterwards, tenocytes were extracted using the migration method. Experiments were conducted at passage three. Optimization of MMC conditions was assessed using 50 to 500 μg/ml carrageenan (Sigma Aldrich, UK). For variable oxygen tension cultures, tenocytes were incubated in a Coy Lab (USA) hypoxia chamber. ECM synthesis and deposition were assessed using SDS-PAGE (BioRad, UK) and immunocytochemistry (ABCAM, UK) analysis. Protein analysis for Scleraxis (ABCAM, UK) was performed using western blot. Gene analysis was conducted using a gene array (Roche, Ireland). Cell morphology was assessed using bright-field microscopy. All experiments were performed at least in triplicate. MINITAB (version 16, Minitab, Inc.) was used for statistical analysis. Two-sample t-test for pairwise comparisons and ANOVA for multiple comparisons were conducted SDS-PAGE and immunocytochemistry analysis demonstrated that human tenocytes treated with the optimal MMC concentration at 2% oxygen tension showed increased synthesis and deposition of collagen type I, the major component of tendon ECM. Moreover, immunocytochemistry for the tendon-specific ECM proteins collagen type III, V, VI and fibronectin illustrated enhanced deposition when cells were treated with MMC at 2% oxygen tension. In addition, protein analysis revealed elevated dexpression of the tendon-specific protein Sclearaxis, while a detailed gene analysis revealed upregulation of tendon-related genes and downregulation of trans-differentiation markers again when cells cultured with MMC at 2% oxygen tension. Finally, low oxygen tension and MMC did not affect the metabolic activity, proliferation and viability of human tenocytes. Collectively, results suggest that the synergistic effect of MMC and low oxygen tension can accelerate the formation of ECM-rich substitutes, which stimulates tenogenic phenotype maintenance. Currently, the addition of substrate aligned topography together with MMC and hypoxia is being investigated in this multifactorial study for the development of an implantable device for tendon regeneration.
Tissue engineering by self-assembly is a technique that consists of growing cells on surfaces made of thermoresponsive polymers, that allow the production of contiguous cell sheets by simply lowering the temperature below the polymer's low critical solution temperature. In this approach cell-cell junctions and deposited extracellular matrix (ECM) remain intact, which provides a better cell localisation at the site of injury. However, these systems lack the possibility to fabricate multi-layered and three-dimensional cell sheets that would better recapitulate native tissues. Moreover, the fabrication of ECM-rich cell sheets would be highly desirable. This limitation could be overcome by inducing macromolecular crowding (MMC) conditions. Herein we venture to fabricate electrospun thermoresponsive nanofibres to sustain the growth and detachment of ECM-rich tissue substitutes in the presence of a MMC microenvironment. A copolymer of 85% poly-N-isopropylacrylamide and 15% N-tert-butylacrylamide (pNIPAAm/NTBA) were used for all experiments. To create aligned nanofibers, the polymer was electrospun and collected on a mandrel rotating at 2000 rpm. Human adipose derived stem cells (hADSC) were treated with media containing macromolecular crowders to enhance matrix deposition. Cell viability and morphology were assessed, and immunocytochemistry was conducted in order to estimate matrix deposition and composition. Adipogenic, osteogenic and chondrogenic assays were performed both with and without the presence of MMC. Non-invasive cell detachment was enabled by decreasing the temperature of culture to 10 °C for 20 minutes. The electrospinning process resulted in the production of pNIPAm/NTBA fibres in the diameter range from 1 to 2 µm and an overall alignment of 80%. Cell viability, proliferation and metabolic activity revealed that hADSCs were able to grow on the thermoresponsive scaffold. The cells were able to detach as an intact cell sheet in presence of MMC. Moreover, it was demonstated that MMC, by a volume extrusion effect, enhances Collagen type I deposition, which is one of the main components of the ECM. Histological analysis revealed that in the presence of MMC the cells were able to self-assembled into three dimensional multi-layers. The cells were able to differentiate towards the osteogenic and adipogenic lineage in the presence of MMC. Interestingly we were able to fabricate three-dimensional chondrogenic cell sheet both with and without MMC. Collectively the pNIPAm/NTBA thermoresponsive fibres were able to sustain the growth and the detachment of ECM-rich multi-layered cell sheets. The pNIPAm/NTBA fibres were able to successfully sustain growth and detachment of ECM-rich tissue equivalents. We believe that replacement, repair and restoration of tissue function can be accomplished best using cells that create their own tissue-specific extracellular matrix with a precision and stoichiometric efficiency still unmatched by man-made devices.
Deep venous thrombosis (DVT) is a potentially serious complication after total hip (THA) and knee (TKA) arthroplasty, traditionally justifying aggressive prophylaxis with low molecular weight heparin (LMWH) or direct oral anticoagulants (DOA) at the cost of an increased risk of bleeding. However, fast-track procedures might reduce the DVT risk and decrease the cost-benefit ratio of the current recommendations. The objective of this study was to compare thrombotic and bleeding risk in an unselected population of elective THA and TKA with a fast-track procedure. A series of 1,949 patients were analyzed prospectively. There were 1,136 women and 813 men, with a mean age of 70 years. In particular, 16% were previously treated by antiplatelet agents and 8% by anticoagulants. All patients followed a fast-track procedure including early walking within 24 hours of surgery, and 80% of patients returned home after surgery, with a mean length of stay of 3 days (THA) or 4 days (TKA). The occurrence of a thromboembolic event or hemorrhagic complication has been identified.Introduction
MATERIAL - METHODS
Prosthetic joint infection (PJI) remains the most severe complication of arthroplasty. Failure of intensive, long-term antibiotic treatment for PJI often requires removal of the implant. Antibiotic failure is thought to be caused by biofilm and persister formation. Novel anti-biofilm and anti-persister strategies are urgently needed. Here, we investigated the effects of several antimicrobial peptides on the bacteria within antibiotic-treated biofilms in an On polystyrene, a mature (7 day-old) methicillin-resistant Aims
Methods
A 2011 Cochrane review concluded that spinal manipulative therapy (SMT) is no better than other interventions for reducing pain and improving function in chronic low back pain (CLBP). Using individual participant data (IPD) from trials has advantages, among others: a more precise estimate of the effect and the potential to identify moderators. Our objective was to assess the effect of SMT in adults with CLBP and to identify relevant moderators. All trials from the 2011 Cochrane review were included in this IPD. We updated the search (April 2016) IPD from eligible studies was requested. Primary outcomes were pain intensity (VAS/NRS) and back-specific function (RMDQ). Risk of bias was assessed. For the treatment effect, an one-stage approach (mixed model technique, intention-to-treat principle) was used; a second-stage approach was conducted as confirmation. For the moderator analyses, one-stage approach was conducted for 19 variables.Purpose of the study and background
Methods
Rotational or axial alignment is an important concept in total knee surgery. Malrotation of the femoral component can lead to patellofemoral maltracking, pain and stiffness. In reconstruction surgery of the knee, achievement of correct rotation is even more difficult because of the lack of anatomical landmarks. The linea aspera is often the only remaining landmark, but its reliability is questionable. Can custom-made 3D-guides help with rotational alignment of the knee after a wide resection of the distal femur?Introduction
Goal of research
Orthopedic implant related surgical site infection (SSI) is a severe complication which represents an important challenge concerning to its treatment. Therefore, gram-negative orthopedic infections have recently become a global concern. Retrospective study through searching of the SCIH (infection control service) database, concerning to the year 2016 and 2017. Cases selected were those of implant placement clean surgeries (osteosynthesis or prosthetic placement) which evolved with SSI and Gram-negative bacterial growth in bone tissue or periprosthetic cultures.Aim
Method
Obese patients are not only more likely to receive total joint arthroplasty, but are also more prone to postoperative complications. The most severe complication is a prosthetic joint infection (PJI), occurring two to four times more often in severely obese patients (BMI ≥ 35kg/m2) compared to non-obese patients. This higher risk for PJI may be attributed to higher glucose levels in case of diabetes mellitus, diminished wound healing or inadequate antibiotic prophylaxis. To ultimately improve the prevention measures for this specific patient category, we aimed to describe the clinical and microbiological characteristics of early acute PJI in severely obese patients. We retrospectively evaluated patients with early acute PJI of the hip and knee treated with DAIR between 2006 and 2016 in three Dutch hospitals. According to protocol, cefazolin was administered as antibiotic prophylaxis during arthroplasty and adjusted to bodyweight. PJI was diagnosed using the criteria described by the Musculoskeletal Infection Society. Early acute PJI was defined as less than 21 days of symptoms and a DAIR performed within 90 days after index surgery. Several clinical and microbiological variables were collected and analyzed. Severe obesity was defined as a BMI ≥ 35kg/m2.Aim
Method
Debridement, antibiotics and implant retention (DAIR) is a widely used treatment modality for early acute prosthetic joint infection (PJI). A preoperative risk score was previously designed for predicting DAIR failure, consisting of chronic renal failure (K), liver cirrhosis (L), index surgery (I), cemented prosthesis (C) and C-reactive protein >115mg/L (KLIC). The aim of this study was to validate the KLIC score in an external cohort. We retrospectively evaluated patients with early acute PJI treated with DAIR between 2006 and 2016 in three Dutch hospitals. Early acute PJI was defined as less than 21 days of symptoms and DAIR performed within 90 days after index surgery. Failure was defined as the need for 1) second DAIR, 2) implant removal, 3) suppressive antimicrobial treatment or 4) infection-related death within 60 days after debridement.Aim
Method
Tissue engineering by self-assembly offers the possibility to fabricate contiguous cell sheets that are stabilised by intact cell-cell contacts and endogenously produced extracellular matrix (ECM) However, these systems lack the possibility to introduce topographical cues, that are fundamental for the organisation of many types of tissues. Herein we venture to fabricate aligned electrospun thermoresponsive nanofibres to sustain growth and detachment of ECM-rich living substitutes in the presence of a MMC microenvironment. A copolymer of 85% poly-N-isopropylacrylamide and 15% N-tert-butylacrylamide (pNIPAAm/NTBA) were used. To create aligned nanofibers, the polymer was electrospun and collected on a mandrel rotating at 2000 rpm. Human adipose derived stem cells (hADSC) were treated with media containing macromolecular crowders to enhance matrix deposition. Cell viability and morphology were assessed, and immunocytochemistry was conducted to estimate matrix deposition and composition. Non-invasive cell detachment was enabled by decreasing the temperature of culture to 10 °C for 20 minutes. The electrospinning process resulted in the production of pNIPAm/NTBA fibres in the diameter range from 1 to 2 µm and an overall alignment of 80%. Cell viability revealed that hADSCs were able to grow on the scaffold. The cells aligned on the fibres after 3 days and they were able to detach as intact cell sheets in presence of MMC. Moreover, it was demonstrated that MMC, by a volume extrusion effect, enhances collagen type I deposition, one of the main components of the ECM. Collectively the pNIPAm/NTBA fibres were able to successfully sustain growth and detachment of ECM-rich cell sheets.
Conventional marker based optical motion capture (mocap) methods for estimating the position and orientation (pose) of anatomical segments use assumptions that anatomical segments are rigid bodies and the position of tracking markers is invariant relative to bones. Soft tissue artefact (STA) is the error in pose estimation due to markers secured to soft tissue that moves relative to bones. STA is a major source of pose estimation error and is most prevalent when markers are placed over joints. Mocap and bi-plane videoradiography data were recorded synchronously while three individuals walked on a treadmill. For all three, pose of the thigh and shank, and movement of markers relative to the bones, were determined from the videoradiography data (DSX, C-Motion). Independently, pose of thighs and shanks was estimated using mocap data (Visual3D, C-Motion). Our measures of error in the mocap pose estimation were the relative thigh and shank translations. X-ray data from two subjects were used to generate a regression model for the antero/posterior movement of the lateral knee marker against internal/external hip rotation. The mocap translation errors of the third subject, attributed to STA of the knee marker, were 15.6mm and 32.0mm respectively. The pose of the third subject was then estimated using a probabilistic algorithm incorporating our regression model. Mocap translation errors were reduced to 10.6mm (thigh) and 4.4mm (shank). The results from these data suggest that errors in pose estimation due to STA may possibly be reduced via the application of algorithms based on probabilistic inference to mocap data.
Fabrication of biogenic coatings with suitable mechanical properties is a key goal in orthopedics, to overcome the limitations of currently available coatings and improve the clinical results of coated implants compared to uncoated ones. In this paper, biological-like apatite coatings were deposited from a natural bone-apatite source by a pulsed electron deposition technique (PED). Bone apatite-like (BAL) films were deposited directly from bone targets, obtained by standard deproteinization of bovine tibial cortical shafts and compared to films deposited by sintered stoichiometric-hydroxyapatite targets (HA). Deposition was performed at room temperature by PED in the Ionized Jet Deposition (IJD) version. Half of the samples was annealed at 400°C for 1h (BAL_400 and HA_400). As-deposited and annealed coatings were characterized in terms of composition and crystallinity (XRD, FT-IR), microstructure and morphology (SEM-EDS, AFM) and mechanical properties (nanoindentation and micro-scratch). For the biological tests, human dental pulp stem cells (hDPSCs) were isolated from dental pulp from patients undergoing a routine tooth extraction, plated on the samples (2500 cells/cm2) and cultured for 3 weeks, when the expression of typical osteogenic markers Runx-2, osteopontin, Osx and Osteocalcin in hDPSCs was evaluated. Results showed that deposition by PED allows for a close transfer of the targets” composition. As-deposited coatings exhibited low cristallinity, that was significantly increased by post-deposition annealing, up to resembling that of biogenic apatite target. As a result of annealing, mechanical properties increased up to values comparable to those of commercial plasma-sprayed HA-coatings.
In conclusion, bone-like apatite coatings were deposited by PED, which closely resembled composition and structure of natural-apatite. Upon annealing at 400°C, the coatings exhibited satisfactory mechanical properties and were capable of providing a suitable microenvironment for hDPSCs adherence and proliferation and for them to reach osteogenic commitment. These results suggest that bone apatite-like thin films obtained by biogenic source may represent an innovative platform to boost bone regeneration in the orthopedic, maxillofacial and odontoiatric field.