Measurement inconsistency across clinical trials is tackled by the development of a core outcome measurement set. Four core outcome domains were recommended for clinical trials in patients with non-specific LBP (nsLBP): physical functioning, pain intensity, health-related quality of life (HRQoL), and number of deaths. This study aimed to reach consensus on core instruments to measure the first three domains. The Steering Committee overseeing this project selected 17 potential core instruments for physical functioning, three for pain intensity, and five for HRQoL. Evidence on their measurement properties in nsLBP was synthesized in three systematic reviews using COSMIN methodology. Researchers, clinicians, and patients (n = 208) were invited in a Delphi survey to seek consensus on which instruments to endorse as core. Consensus was Background & purpose
Methods & Results
Evaluation of the effectiveness of biodegradable bone substitute with high doses of antibiotics in cavitary osteomyelitis and infected nonunions. The authors evaluated 8 cases, 5 of them related to osteomyelitis with bone sequestration and other 3 regarding infected nonunions. All of them had in common the persistence of infection after antibiotic therapy. All infections were confirmed by microbiological studies. In all cases the surgeons conducted a thorough surgical debridement and filling of bone defects with Herafill®. Later a tight clinical, analytical and imagiological control was performed. Five of the cases were a success with simultaneous healing of the bone loss and treatment of the infection. These corresponded to the cases of cavitary osteomyelitis. In the remaining 3 cases, despite infection eradication, union was not achieved and additional surgical procedures were required for definitive treatment of nonunion. In the treatment of bone infection, use of high doses of antibiotics at the site is a consensus as it allows eradication of the infection with lower systemic effects. With the emergence of biodegradable bone substitutes, the need for a new surgical intervention for their removal can be avoided. Properties of calcium sulfate and calcium carbonate stimulate osteogenesis at the site, allowing their absorption and replacement by bone matrix. These properties make them ideal to usage in cases of cavitary bone defects. Our experience supports the idea that the use of high doses of antibiotics locally permits remission of the infection. However, when this is implemented through a bone substitute, it is possible to achieve osteogenesis in bony cavities. Nevertheless, when applied to infected nonunions, their role seems to be limited to the eradication of the infection.
Recent findings about UHMWPE oxidation from in vivo stresses lead to the need of a better understanding of which anti-oxidant additivation method is the best option for the use in orthopaedic field. A GUR 1050 crosslinked Vitamin E - blended UHMWPE has been investigated, to provide an accurate outline of its properties. DSC and FTIR measurements, together with ageing and tensile tests were performed on compression moulded blocks, as well as biocompatibility tests, including implantation on rabbits. Moreover, wear simulations on finished components (Delta acetabular liners) have been completed. All the test procedures have been repeated for a reference material, a GUR 1050 crosslinked and remelted standard UHMWPE (commercial name UHMWPE X-Lima), and the outcomes have been compared to the crosslinked Vitamin E - blended UHMWPE ones. On the additivated UHMWPE, we found a ultimate tensile strength of 43 MPa, a yield strength value of 25 MPa, and an elongation to breakage equal to 320%. The degree of cristallinity was 45 ± 2%, and no signal of creation of oxidation products was detected up to 2000 h of permanence in oxidant ambient after the ageing test. The reference material showed comparable mechanical resistance values (∗ = 40 MPa, y = 20 MPa, 350% elongation), a cristallinity of 46 ± 2%, and the creation of oxidation products starting from 700 h in oxidant ambient. The biocompatibility tests indicate that the additivated material is biocompatible, as the reference X-Lima UHMWPE. Wear tests gave a wear rate of 5,09 mg/million cycles against 6,13 mg/million cycles of the reference material, and no sign of run in wear rate. Our results indicate that there is no change in mechanical properties in respect to the reference material. This is confirmed by DSC measurements, that show no change in cristallinity. The blend between polymer and additive assures an uniform concentration of Vitamin E across the whole thickness of the moulded block, and ageing test results on additivated UHMWPE have shown that the material possess a superior resistance to degradation phenomena. Biocompatibility assess that the presence of Vitamin E is not detrimental for the in vivo use of the material, and wear results indicate a better wear resistance of the material, especially in the first stages of the wear process. From these considerations, it can be concluded that the material, in respect to the standard UHMWPE, is highly resistant to oxidation phenomena, therefore it is expected to have superior in vivo endurance performance.
Distal radius fractures (DRF) are a common injury in the A&E departments, being a major cause of disability of the upper extremity. The aim of this prospective study is to assess the possible association between objective physical variables such as wrist range of movement (ROM), radiological parameters, and upper extremity disability (measured by the DASH questionnaire), after conservative treatment of DRF. 44 patients with non-operatively managed DRF were enrolled in a prospective cohort study from July 2007 till September 2009. Inclusion criteria: unilateral DRF in skeletally mature patients, treated non-operatively with closed reduction and cast. Patients who sustained a previous fracture of the wrist, or bilateral wrist fracture, or with dementia, were excluded. After the closed reduction and inmovilization of the fracture in the A&E department we asked the patients to complete the DASH questionnaire, referring to their baseline pre-fracture state. All fractures were classified according to the AO classification. After one year, 36 patients were still available for follow-up purposes. We assesed the following objective physical variables: ROM of both wrists: flexion/extension arc and pronation/supination arch. We recorded the following radiologic parameters: radial angulation, volar angulation and radial shortening. The patient-perceived results were measured by the DASH questionnaire, while pain was measured using the VAS scale. Statistical analysis was performed using the SPSS 15.0.Introduction
Patients and methods
The samples were treated in an air circulating oven at 90°C. Every 20 hours they were analyzed with FTIR and the carbonyl concentration was recorded. The CL-imaging measurements were run at 180°C under oxygen in a Differential Scanning Calorimetry (DSC) coupled to a CCD camera. The Oxidation Induction Time (OIT) has been measured as the starting time of oxidation, extrapolated from the CL curve in the function of time.
The ability of α-tocopherol as a free radicals scavenger during gamma irradiation prevents the reaction of polymer radicals with oxygen. While performing this role, α-tocopherol is consumed and transformed into a variety of by-products. Nevertheless, higher OIT for the doped and irradiated specimens compared to the control (0% Vit.E, 0 kGy) suggest even a stabilising effect of these by-products.
During the last 15 years we have had the opportunity of analysing more than 700 UHMWPE prosthetic components (hip, knee and shoulder). Among them, about 500 were retrieved during revision surgery, while the remaining were new, ready-to implant, variably shelf-aged samples. The analysis of such a large, representative sample provided several important insights into the variables which influence the behaviour of UHMWPE in vivo; moreover, a long period of observation gave us the opportunity to follow changes and improvements in the field over time. All samples dated back to the nineties or before and sterilized with high energy radiation, either shelf-aged or retrieved, showed variable, but generally high, oxidation levels. Starting from the observation of these samples and with the aid of specimens irradiated on purpose under controlled conditions, some improvement has been achieved in the knowledge of radiation-induced oxidation process. The importance of the determination of hydroperoxides on the oxidation potential has been highlighted and the influence of variables such as sterilisation atmosphere, packaging, temperature and dose rate on the oxidation process has been clarified. The need for a suitable stabilizer to minimize oxidation arises during these studies. We also had the opportunity of analysing a large number of EtO-sterilised samples, both new and retrieved. A small amount of them, all manufactured in the nineties, showed some bulk-oxidation which has been related to the presence of calcium stearate into the pristine resin. None of the newly produced, calcium stearate-free samples showed any oxidation and this group allowed to explore the behaviour of undegraded UHMWPE in vivo and in the shelf. Diffusion of polar compounds from the synovial fluid into polyethylene was observed in the majority of the retrieved samples. The nature of these products have been investigated along with their possible influence on the mechanical properties of the polymer. In the last five years, we had the opportunity to study a significant number of crosslinked polyethylenes, both new and retrieved. The results of this study indicate that the variables of the crosslinking process can greatly influence final material properties and that not all cross-linked polyethylenes are the same.
The SEM analyses indicated that the PEs surface which was directly in contact with bone shows an anomalous degradation. The surface looks as it has been corroded or “bitten” and its morphology is significantly different from that of surfaces abraded either in vivo or in vitro.