The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage.Aims
Methods
In recent conflicts, most injuries to the limbs are due to blasts resulting in a large number of lower limb amputations. These lead to heterotopic ossification (HO), phantom limb pain (PLP), and functional deficit. The mechanism of blast loading produces a combined fracture and amputation. Therefore, to study these conditions, in vivo models that replicate this combined effect are required. The aim of this study is to develop a preclinical model of blast-induced lower limb amputation. Cadaveric Sprague-Dawley rats’ left hindlimbs were exposed to blast waves of 7 to 13 bar burst pressures and 7.76 ms to 12.68 ms positive duration using a shock tube. Radiographs and dissection were used to identify the injuries.Aims
Methods
axes bearing 10° or more from the blade deviated significantly and were eliminated; insensitivity to scapular morphological variations based on the smallest SD and axes applicability in pathology based on VDA of the remaining axes were graded for the final result.
Many different clinical examinations are used to assess instability of the glenohumeral joint. Validation of these includes clinical data, follow-up, imaging, and arthroscopy. In spite of these many works, there currently exists no clear unique method for identifying and validation novel clinical examinations. The aim of this study was to use a computational tool to quantify the specificity of clinical examinations in assessing glenohumeral ligament (GHL) pathology. Five GHLs were modelled according to the literature [
Anterior loading of the tibia increased AMB strain. With the tibia free to rotate, strain was highest at 90 degrees knee flexion (5.3%) and lowest at 0 degrees (1.6%). Fixed internal and external tibial rotation reduced AMB strain produced by a 150 N anterior drawer force at all knee flexion angles. Strain data for analysis was available for 6 Posteromedial Corner deficient knees: With the tibia free to rotate or when locked in internal rotation, cutting the posteromedial structures had no effect on AMB strain with a 150 N anterior drawer force applied to the tibia. However, with the tibia locked in external rotation, cutting the posteromedial structures increased AMB strain at 60 and 90 degrees flexion. This difference however did not reach statistical significance.
The aim of this study was to determine the function of the meniscofemoral ligament in the cranio-caudal and rotatory laxity of the ovine stifle. Twenty fresh cadaveric ovine stifles were harvested from fully mature sheep, average weight 25kg. The joint was denuded of its muscular attachments leaving the capsule, including the patella and patellar tendon undisturbed. The femur and tibia were divided 10 cm from the joint line, positioned in cylindrical pots, and secured in polymethylmethacrylate bone cement. The stifles were tested in a four-degree-of-freedom rig positioned in an Instron materials testing machine. This allowed unconstrained coupled tibial rotations and translations during application of cranial (anterior) and caudal (posterior) draw forces. Forces up to a maximum of 100Nm were applied in the anterior and posterior directions, and the resultant translations were measured. These parameters were assessed at 30, 60, 90, and 110 degrees of flexion in ten intact stifles. Similar measurements were carried out after division of the caudal (posterior) cruciate ligament, followed by division of the meniscofemoral ligament. The sequence of division was reversed for a further ten stifles. Division of the meniscofemoral ligament resulted in an 18–38% increase in posterior translation at all angles of flexion, both in the intact and in the caudal cruciate ligament-deficient stifle (p<
0.05). There was no significant increase in anterior translation. This effect was largest with the joint relatively extended (at 30°). Division of the meniscofemoral ligament also resulted in a 5–32% increase in internal rotation of the tibia after application of a 6Nm torque in the caudal cruciate-deficient knee. This was significant at 30° and 110° flexion (p<
0.05). The meniscofemoral ligament is a significant secondary restraint in resisting the posterior draw and internal tibial rotation in the sheep stifle joint. This is the first study demonstrating a functional role for this structure in any animal. Its counterpart in the human is the posterior meniscofemoral ligament of Wrisberg. Several studies have demonstrated similarities between the sheep stifle and the human knee. Confirmation of a similar role for the ligament of Wrisberg in the human knee would have a significant bearing on the prognosis and management of the posterior cruciate ligament injured knee.
Race A., Amis A.A., 1996. Cross-sectional area measurement of soft tissue. A new casting method. RaceA., Amis A.A., 1994a. The mechanical properties of the two bundles of the human posterior cruciate ligament. Friederich N F., O’Brien W., 1990. Functional anatomy of the meniscofemoral ligaments. Fourth Congress of the European Society of Sports Traumatology Knee Surgery and Arthroscopy (ESSKA)
The function of the meniscofemoral ligaments is undetermined, although many hypotheses comment on a role in guiding the motion of the lateral meniscus during knee flexion. Other possibilities include a function as a secondary restraint supplementing the posterior cruciate ligament.