The aim of the study was to assess the medium term outcome for complex proximal humeral fractures treated with the long proximal humeral internal locking system (PHILOS) plate fixation. All patients who had long PHILOS plate fixation of proximal humerus fractures with metaphyseal or diaphyseal extension over a three year period at our institution were included in the study. Patients had their case notes and radiographs reviewed. Patients were also contacted to assess functional outcome using the Visual Analogue Scale (VAS) for pain, DASH, Oxford shoulder score (OSS) and Stanmore Percentage of Normal Shoulder Assessment (SPONSA). Out of an initial cohort of 34 patients, 1 died, 2 patients had unrelated illnesses resulting in them being unable to complete the assessment and 6 were lost to follow-up, leaving 25 patients (74%) for review. All patients had proximal humeral fractures with metaphyseal or diaphyseal extension requiring long plate osteosynthesis. One patient had the procedure for non union following initial treatment with an intra medullary nail and the rest were acute injuries. The patients were followed up after a mean of 27 months (range 11–60). The length of plate used varied from 5 to 12 holes for the shaft region. There was 1 wound infection. 3 patients had non unions which required bone grafting and revision internal fixation. At final follow-up, mean pain was 3.6 (95% Confidence Interval 2.5–4.8) with only 4 patients having residual pain greater than 5 on the VAS scale. Mean DASH score was 41.2 (95% CI 32.0–50.4), mean OSS was 29.1 (95% CI 24.3–33.9) and mean SPONSA was 63.9% (95% CI 50.8–77.2) The long PHILOS plate appears to represent a good treatment option for complex proximal humerus fractures with favourable medium term results and few complications.
The aim of the study was to assess the rate of greater tuberosity non union in reverse shoulder arthroplasty performed for proximal humerus fractures and to assess if union is related to type of fracture or the intraoperative reduction of the greater tuberosity. All cases of reverse shoulder arthroplasty for proximal humerus fractures at our institution over a three year period were retrospectively reviewed from casenotes and radiologically and the position of the greater tuberosity was documented at immediate post op, 6 months and 12 months. Any malunion or non union were noted. A total of 27 cases of reverse shoulder arthroplasty for proximal humeral fractures were identified. 4 cases did not have complete follow up xrays and were excluded from analysis. The average age at operation of the cohort of the 23 remaining patients was 79 years (range 70–91). The greater tuberosity was anatomically well positioned intraoperatively in 17 of the 23 cases. At the end of 12 months there were 4 cases of tuberosity non union (17%), all except one occurring in poorly intraoperatively positioned greater tuberosity. 50% (3 out of 6) of greater tuberosities displaced further and remained ununited if the intraoperative position was poor. Only 6% (1 out of 17) greater tuberosities did not unite if the greater tuberosities was reduced anatomically. Intra operatively position of the greater tuberosity was strongly associated with their union (Fischer's exact test p<0.05). Union of greater tuberosity was not statistically associated with fracture pattern (Fischer's exact test p=0.48). Our case series show a low rate of tuberosity malunion after reverse shoulder arthroplasty for proximal humerus fracture. Good positioning and fixation of the greater tuberosity intra operatively is a strong predictor of their uneventful union to shaft.
The aim of this study was to evaluate prospectively the outcome following arthroscopic Bankart repair using two types of suture anchors, absorbable and non-absorbable. Patients with a diagnosis of recurrent traumatic anterior instability of the shoulder, seen between April 2000 and June 2003 in a single unit, were considered for inclusion in the study. Patients were assessed pre-operatively and post-operatively using a subjective patient related outcome measurement tool (Oxford instability score), a visual analogue scale for pain and instability (VAS Pain and VAS instability) and a quality of life questionnaire (SF-12). The incidence of recurrent instability and the level of sporting ability were recorded. Patients were randomised to undergo surgical repair with either non-absorbable or absorbable anchors. 130 patients were included in the study. 6 patients were lost to follow-up and 124 patients (95%) completed the study. Both types of anchors were highly effective. There were no differences in the rate of recurrence or any of the scores between the two. Four patients in the non-absorbable group and 3 in the absorbable group experienced further episodes of dislocation after a traumatic event. The rate of redislocation in the whole series was therefore, 5.6%. In addition, 4 patients, all of them in the absorbable group (4%) described ongoing symptoms of instability but no true dislocations. 85% of the patients have returned to their previous level of sporting activity. There are no differences in the outcome of Arthroscopic Bankart repair using either absorbable or non-absorbable anchors. Both are highly effective, showing a redislocation rate of 5.6%.
A prospective study was carried out over a period of 4 years. 31 patients with a mean age of 49 years were treated using the clavicular hook plate. The mean follow up was 28.34 months. 23 patients were operated primarily and 8 patients were operated for symptomatic non-union. All the patients achieved clinical and radiological union in a mean 12.71 weeks. According to Constant scoring the mean was 94. According to HSS (Hospital for Special Surgery) scoring 9 patients had excellent, 21 had good. The clinical results of the clavicular hook plate were good leading to good shoulder girdle function.
Recently concerns have been raised as to the effect of intra-articular radio-frequency energy on axillary nerve function. In our unit 120 shrinkage procedures have been performed with 5 intra-operative contractions of deltoid and no axillary nerve palsy. In this study we aimed to identify and quantify any changes in axillary nerve function following capsular shrinkage. Needle electrodes were inserted into the deltoid muscle of 10 patients undergoing radio-frequency capsular shrinkage and 3 patients having diagnostic arthroscopy. Recordings of Compound Muscle Action Potentials (CMAPs) were made following pre-operative magnetic coil stimulation of the axillary nerve. The nerve was then monitored during operation. At the end of the procedure, a further recording of CMAP following axillary nerve stimulation was made to allow comparison with initial readings. We have shown:
Low amplitude stimulations of the axillary nerve in 6 of the 10 patients undergoing shrinkage. Increase in latency of the axillary nerve was noted in some patients including the controls. Increase in latency was independent of time spent performing shrinkage. We have concluded:-
Stimulation of the axillary nerve occurs frequently during capsular shrinkage. This axillary nerve stimulation cannot be causally related to the application of radio-frequency energy. Increased latency may occur due to cooling of the nerve by extravasated irrigation fluid. Nerve monitoring is recommended during the training of surgeons new to this technique. We would like to acknowledge the Magstim Company for their assistance with this project.
The aim of this study was to investigate if the rotational axis of normal human shoulders moves during flexion in the sagittal plane. Twenty four shoulders were measured in twelve normal volunteers, aged 25-42, height range 1.65-1.88 m and weight range 63–120 Kg. Each subject had surface markers placed on their iliac crests, mastoid processes and upper arms. Joint movement was video recorded as shoulders were actively flexed and extended in the sagittal plane. For each joint, a typical flexion sweep was selected and replayed into a computerised imaging system, where still frames were captured at 20 degree intervals from 20 to 120 degrees. These images were analysed to extract the co-ordinates of each marker. The coordinates were then processed to determine the Instant Centres of Rotation (ICR) for each angle of flexion. These ICR’s were then plotted to derive the Rotational Axis Pathway (RAP) for each shoulder joint. The results indicate that throughout the flexion arc, the rotational axis is located in the region of the humeral head. At the start of the arc the rotational axis is in the anterio-superior part of the shoulder joint. As the shoulder flexes forward the rotational axis moves posteriorly following a curved pathway. In 18 cases the RAPs moved posterio-inferiorly and in six cases the RAPs moved posterio-superiorly. The pathways can be quantified in terms of their curved pathway lengths and the displacements of their end points from their start points. In the case of the 18 posterio-inferior pathways, the mean pathway length was 98.3 mm (SD=31.5) and the mean posterior/inferior displacements were 59.6 mm (SD=34.7) and 43.2 mm (SD=24.6) respectively. In the case of the 6 posterior-superior pathways, the mean pathway length was 109.4 mm (SD=40.2) and the mean posterior/ superior displacements were 94.7 mm (SD=43.9) &
20.9 mm (SD=11.1) respectively. The variation in inferior-superior displacement of the axis may be due to normal variations in scapula movement during forward flexion. This investigation indicates that in normal subjects, the rotational axis moves posteriorly during flexion.