Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction

This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales.

Methods

Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 62 - 62
17 Nov 2023
Lan T Wright K Makwana N Bing A McCarthy H Hulme C
Full Access

Abstract

Objectives

Bone marrow aspirate concentrate (BMAC), together with fibrin glue (Tisseel, Baxter, UK) and Hyaluronic acid (HA) were used as a one-step cell therapy treating patients with ankle cartilage defects in our hospital. This therapy was proven to be safe, with patients demonstrating a significant improvement 12 months post-treatment. Enriched mesenchymal stem cells (MSCs) in BMAC are suggested inducers of cartilage regeneration, however, currently there is no point-of-care assessment for BMAC quality; especially regarding the proportion of MSCs within. This study aims to characterise the cellular component of CCR-generated BMAC using a point-of-care device, and to investigate if the total nucleated cell (TNC) count and patient age are predictive of MSC concentration.

Methods

During surgery, 35ml of bone marrow aspirate (BMA) was collected from each patients’ iliac crest under anaesthesia, and BMAC was obtained via a commercial kit (Cartilage Regeneration kit, CCR, Innotec®, UK). BMAC was then mixed with thrombin (B+T) for injection with HA and fibrinogen. In our study, donor-matched BMA, BMAC and B+T were obtained from consented patients (n=12, age 41 ± 16years) undergoing surgery with BMAC therapy. TNC, red blood cell (RBC) and platelet (PLT) counts were measured via a haematology analyser (ABX Micros ES 60, Horiba, UK), and the proportion of MSCs in BMA, BMAC and B+T were assessed via colony forming unit-fibroblast (CFU-F) assays. Significant differences data in matched donors were tested using Friedman test. All data were shown as mean ± SD.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 21 - 21
1 Jan 2014
Ribee H Bhalla A Patel A Johnson B Leah J Bailey A Chapman C Bing A Hill S Laing P Makwana N Thomason K Marquis C
Full Access

Introduction:

Plantar Fasciitis is an extremely common and challenging problem that presents itself to foot and ankle practitioners. Many different treatment modalities are available for this condition, with little proven benefit. ECSWT was approved for use by the FDA for the treatment of chronic proximal plantar fasciitis in 2002 and NICE published guidance in 2009 recommending its use in refractory cases.

Methods:

Patients who diagnosed with ultrasound scan, and for whom other treatments were unsuccessful, underwent treatment on an outpatient basis. They had three 4–5 minute sessions, once a week. A Spectrum machine was used delivering 10 Hz waves in 500 preset pulses at 2 bar pressure, followed by 2000 preset pulses at 2.5 bar pressure. Pre- and 3 month post-treatment pain levels were recorded using a 10 point Visual Analogue Scale.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 58 - 58
1 Sep 2012
Lever C Bing A Hill S Laing P Makwana N
Full Access

Introduction

Forefoot deformities are common in the rheumatoid population and lead to abnormal loading, plantar callosities and metatarsalgia. First MTP joint arthrodesis with lesser toe Stainsby procedures has become a popular method of reconstructing the rheumatoid forefoot but there is little data that reviews the clinical or biomechanical results of combining the two procedures.

Materials & Methods

A prospective observational study was set up to review 10 rheumatoid patients (20 feet) undergoing bilateral first MTP joint arthrodesis via a medial approach with Stainsby procedures to all lesser toes via curved incisions with resection of two thirds of the proximal phalanx, repositioning of plantar fat pad, extensor to flexor interposition and temporary stabilisation with k wires. Clinical scoring and dynamic pedobarograph pressure measurements were taken pre operatively and at one year post surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 63 - 63
1 May 2012
Malhotra A Gallacher P Makwana N Laing P Hill S Bing A
Full Access

Background

Salvage procedures on the 1st MTPJ following failed arthroplasty, arthrodesis or hallux valgus surgery are difficult and complicated by bone loss. This results in shortened first ray and transfer metatarsalgia. We present our experience of using tri-cortical interposition grafts to manage this challenging problem.

Methods

Between 2002 and 2009 our department performed 21, 1st MTPJ arthrodeses using a tri-cortical iliac crest interposition graft. Surgical fixation was achieved with a compact foot plate. We performed a retrospective review from the medical notes and radiographs along with American Foot and Ankle scores which were collected prospectively.

We analysed the following parameters: time to radiological, requirement for further surgery, lengthening of 1st ray and any post operative complications.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 388 - 388
1 Jul 2010
Cheung G Oakley J Bing A Carmont M Graham N Alcock R
Full Access

Introduction: Primary total hip replacement remains one of the commonest orthopaedic procedures performed. It is yet to be clearly demonstrated whether use of a postoperative drain is of benefit in these procedures.

Methods: We carried out a prospective randomised study comparing the use of autologous reinfusion drains, closed suction drains or no drain to determine their influence on allogenic blood transfusion requirements, length of hospital stay and infection rates. Stratification was carried out for confounding factors.

Results: 153 patients were recruited into the study and randomised to one of the three closely matched groups. There was no significant difference between the mean intra-operative blood loss or post-operative haemaglo-bin levels between the 3 groups. 42% of the suction drain group required post-operative transfusion as compared to 17% of the reinfusion drain group and 12% of the group with no drains. This difference was highly significant (P=0.02) Mean time for the wound to become dry was 3 days, 3.9 days and 4 days in the no drain, re-transfusion drain and suction drain groups respectively. This difference was statistically significant (P=0.03). There was no statistically significant difference in the mean length of inpatient stay.

Discussion: This study demonstrates a significantly higher transfusion rate with closed suction drains compared to reinfusion drains or no drains. With the drive to reduce hospital stay our study supports the considered use of no drain or a reinfusion drain.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 377 - 377
1 Mar 2004
Acharya M Eastwood G Bing A Harper W
Full Access

Background: The majority of extracapsular proximal femoral fractures are treated with a sliding hip screw. The barrel of the plate can slide over the shaft of the screw in two modes; keyed (locked) or unkeyed (unlocked). The purpose of the study was to determine whether there is a difference in outcome following þxation using a sliding hip screw in the locked and unlocked modes.

Methods: A prospective randomised controlled trial of patients requiring a sliding hip screw for a proximal femoral fracture. Patients were randomised to receive a sliding hip screw either in the locked or unlocked mode. 20 patients were randomised to each group. Patients were assessed clinically and radiologically post-operatively and at three months following discharge from hospital. Screw slide and þxation failure were used as primary outcomes. A Visual analogue scoring system (VAS) was used to assess pain.

Results: 40 patients were recruited in this study. Mean age of patients in the locked group was 74.05 years (range 55–90) and 78.0 years (range 65–97) in the unlocked group. There was one case of þxation failure in the locked group compared to two in the unlocked group. The mean screw slide was 10.98mm (range 1.04–37.62) in the locked group and 12.94mm (range 1.91–20.82) in the unlocked group. The pain score according to the VAS improved over the three months. There was no signiþcant difference in pain score between the two groups.

Conclusion:When comparing screw slide, þxation failure and pain, the results show there is no signiþcant difference between using the sliding hip screw in the locked and unlocked mode.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 78 - 78
1 Jan 2004
Acharya MR Eastwood G Bing A Harper WM
Full Access

Background: The majority of extracapsular proximal femoral fractures are treated with a sliding hip screw. The barrel of the plate can slide over the shaft of the screw in two modes; keyed (locked) or unkeyed (unlocked). The purpose of the study was to determine whether there is a difference in outcome following fixation using a sliding hip screw in the locked and unlocked modes.

Methods: A prospective randomised controlled trial of patients requiring a sliding hip screw for a proximal femoral fracture. Patients were randomised to receive a sliding hip screw either in the locked or unlocked mode. 20 patients were randomised to each group. Patients were assessed clinically and radiologically post-operatively and at three months following discharge from hospital. Screw slide and fixation failure were used as primary outcomes. A Visual analogue scoring system (VAS) was used to assess pain.

Results: A total of 40 patients were recruited in this study. The mean age of patients in the locked group was 74.05 years (range 55–90) and 78.0 years (range 65–97) in the unlocked group. There was one case of fixation failure in the locked group compared to two in the unlocked group. The mean screw slide was 10.98mm (range 1.04–37.62) in the locked group and 12.94mm (range 1.91–20.82) in the unlocked group. The pain score according to the VAS improved over the three months. There was no significant difference in pain score between the two groups.

Conclusion: When comparing screw slide, fixation failure and pain, the results show there is no significant difference between using the sliding hip screw in the locked and unlocked mode.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 78 - 78
1 Jan 2004
Acharya MR Harper WM Eastwood G Bing A
Full Access

Background: Cerebral micro emboli have been noted to occur during both total hip and knee arthroplasty. These micro emboli have been implicated in the causation of post-operative cognitive impairment. The aim of this study was to determine whether cerebral micro emboli occur during hip fracture surgery.

Method: 28 patients undergoing hip fracture surgery had transcranial doppler assessment of the middle cerebral artery to detect cerebral micro emboli. Micro embolic signals (MES’s) were recorded during the operative procedure.

Results: Successful monitoring was carried out in 26 patients. MES were recorded in 16 out of 26 patients. 12 out of 16 patients who had MES’s had undergone a cemented hemiarthroplasty the remainder had a sliding hip screw for an extracapsular hip fracture. 75% (9/12) of patients that had a cemented hemiarthroplasty, had the majority of MES’s after reaming and cementing. MES’s in the patients that had a sliding hip screw occurred throughout the operative procedure.

Conclusion: Cerebral micro emboli do occur during hip fracture surgery. These emboli may be responsible for the cognitive dysfunction that occurs in this susceptible group of patients.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 32 - 33
1 Jan 2003
Bing A Esler C
Full Access

To assess total knee arthroplasty function in osteoarthritic patients who had their arthroplasty aged 55 years or less.

Self administered questionnaires were posted to 150 patients who had been registered on the Trent Regional Arthroplasty Register as having their TKA for osteoarthritis aged 55 or less. 85% of questionnaires were returned completed giving us information on 136 TKAs. The mean age of the patients at TKA was 51 yrs (Range 29 – 55 yrs.). Male 60: 67 Female. The mean follow-up was 44 months.

41% of patients had had no knee surgery prior to their TKA. 9 had had a corrective osteotomy.

51 patients had to give up work because of their osteoarthritic knee, only 17 got back to work after their TKA. 80% of patients felt that their arthroplasty had met or exceeded their pre-operative expectation in relieving pain though 41% continue to experience moderate or severe knee pain and 29% continue to have regular night pain. 62% of patients felt that they had been able to resume leisure activities to the same or better level than expected pre-operatively.