Abstract
Background: Cerebral micro emboli have been noted to occur during both total hip and knee arthroplasty. These micro emboli have been implicated in the causation of post-operative cognitive impairment. The aim of this study was to determine whether cerebral micro emboli occur during hip fracture surgery.
Method: 28 patients undergoing hip fracture surgery had transcranial doppler assessment of the middle cerebral artery to detect cerebral micro emboli. Micro embolic signals (MES’s) were recorded during the operative procedure.
Results: Successful monitoring was carried out in 26 patients. MES were recorded in 16 out of 26 patients. 12 out of 16 patients who had MES’s had undergone a cemented hemiarthroplasty the remainder had a sliding hip screw for an extracapsular hip fracture. 75% (9/12) of patients that had a cemented hemiarthroplasty, had the majority of MES’s after reaming and cementing. MES’s in the patients that had a sliding hip screw occurred throughout the operative procedure.
Conclusion: Cerebral micro emboli do occur during hip fracture surgery. These emboli may be responsible for the cognitive dysfunction that occurs in this susceptible group of patients.
Theses abstracts were prepared by Mr Peter Kay. Correspondence should be address to him at The Hip Centre, Wrightington Hospital, Appley Bridge, Wigan, Lancashire WN6 9EP.