Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Bone & Joint Research
Vol. 5, Issue 2 | Pages 26 - 32
1 Feb 2016
Wendling A Mar D Wischmeier N Anderson D McIff T

Objectives

The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing mechanical strength.

Methods

Three batches of vancomycin-loaded PMMA were prepared with different mixing techniques: a standard technique; a delayed technique; and a control without antibiotic. Daily elution samples were analysed using flow injection analysis (FIA). Beginning in Phase II, samples from each mix group were selected randomly to undergo either five, 15, 45, or 0 minutes of LFUS treatment. Elution amounts between LFUS treatments were analysed. Following Phase II, compression testing was done to quantify strength. A-priorit-tests and univariate ANOVAs were used to compare elution and mechanical test results between the two mix groups and the control group.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 422 - 422
1 Apr 2004
Kurosaka M Komistek R Northcut E Dennis D Anderson D
Full Access

Introduction: Previous in vivo kinematic studies have assessed total knee arthroplasty (TKA) motion under weight-bearing conditions. This in vivo study analyzed and compared posterior cruciate retaining (PCR) and posterior stabilized (PS) kinematics under passive and weight-bearing conditions in subjects implanted with both a PCR and PS TKA.

Methods: Eighteen subjects were implanted with a PCR and a PS TKA, by a single surgeon using a similar surgical technique. Both implant designs had similar condylar geometry. Femorotibial contact positions for all 18 subjects (PCR and PS), implanted by a single surgeon, were analyzed using video fluoroscopy. Each subject,while under fluoroscopic surveillance, performed a weight-bearing deep knee bend and a passive, nonweight-bearing flexion. Video images were downloaded to a workstation computer and analyzed at varying degrees of knee flexion. Femorotibial contact paths for the medial and lateral condyles, axial rotation and femoral condylar lift-off were then determined using a computer automated model-fitting technique. Femorotibial contact anterior to the tibial midline in the sagittal plane was denoted as positive and contact posterior was denoted as negative.

Results: Under passive and weight-bearing conditions, the PCR TKA experienced more paradoxical anterior translation than the PS TKA. Under passive, non weight-bearing conditions, the PS TKA, on average, experienced 3.5 mm of posterior femoral rollback, compared to only 0.6 mm for the PCR TKA. Under weight-bearing conditions, the PS TKA experienced only 0.6 mm of posterior femoral rollback, compared to 0.9 mm for the PCR TKA. The maximum anterior slide was 10.0 mm for the PCR TKA and only 2.7 mm for the PS TKA. There was greater variability in both the PCR and PS anteroposterior data. Subjects having a PCR TKA experienced more normal axial rotation patterns. Sixteen of 18 PCR TKA experienced a normal axial rotation pattern under weight-bearing conditions, while only 9/18 PS TKA experienced a normal pattern. Nonweight-bearing, passive axial rotation patterns were more abnormal for both groups than the weight-bearing patterns. The greatest difference between passive and weight-bearing conditions occurred in the condylar lift-off data. Under passive conditions, both TKA groups experienced significantly greater magnitude and incidence of condylar lift-off. The maximum amount of condylar lift-off under passive conditions was 5.0 mm for the PCR TKA and 6.4 mm for the PS TKA.

Discussion: This is the first in vivo kinematic study to assess a comparison between PCR and PS TKA implanted by the same surgeon in the same patient. Subjects in this study experienced more abnormal kinematic patterns, especially condylar lift-off, when tested under passive, nonweight-bearing conditions. Subjects having a PS TKA experienced less variability in their kinematic data, but PCR TKA, on average, experienced more normal axial rotation and less condylar lift-off.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 412 - 412
1 Apr 2004
Komistek R Dennis D Sedel L Northcut E Anderson D
Full Access

Introduction: Previous in vivo kinematic analyses of the hip joint have determined that femoral head separation from the medial aspect of the acetabular component occurs in metal-on-polyethylene THA. The present study analyzes subjects having either an alumina-on-alumina (AOA),alumina-on-polyethylene (AOP),metal-on-metal (MOM) or metal-on-polyethylene (MOP) THA during gait to determine if the incidence of hip joint separation varies based on articular surface material.

Methods: Forty subjects were analyzed in vivo using video fluoroscopy. Ten subjects had a AOA THA, ten an AOP THA, ten a MOM THA, and ten having a MOP THA. All THA subjects were implanted by two surgeons and were judged clinically successful (Harris hip scores > 90.0). Each subject performed normal gait on a treadmill and an abduction/adduction leg lift maneuver while under fluoroscopic surveillance. The two-dimensional (2D) fluoroscopic videos were converted into 3D using a computer automated model-fitting technique. Each implant was analyzed at varying flexion angles to assess the incidence of hip joint separation.

Results: During gait and the abduction/adduction leg lift, no separation was observed in subjects having an AOA THA or in subjects having a MOM THA. Similar to our previous studies pertaining to subjects having a THA with a polyethylene acetabular insert, all ten subjects having a MOP THA and 6/10 subjects having an AOP THA experienced hip joint separation. The maximum amount of separation was 7.4 mm for a subject having an AOP THA and 3.1 mm for a subject having a MOP THA.

Discussion: This study shows femoral head separation from the medial aspect of the acetabular component can occur in the presence of a polyethylene liner. The femoral head often remains in contact with the liner, hinging superolaterally. Potential detrimental effects resulting from hip joint separation include premature polyethylene wear, component loosening (secondary to impulse loading conditions) and hip instability. Wear may be enhanced due to creation of multidirectional wear vectors or excessive loads due to eccentric femoral head pivoting. The absence of separation observed in AOA and MOM THA designs may be related to increased wettability of these materials and tighter radial tolerances resulting in a cohesive lubrication film. This data may be of value in hip simulation studies to better duplicate wear patterns observed in retrieval analyses and assist in the understanding of the lubrication regime and wear rates in AOA and MOM designs, allowing for the synthesis of prosthetic components that minimize wear and optimize kinematics.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 409 - 409
1 Apr 2004
Anderson D Lombardi A Komistek R Northcut E Dennis D
Full Access

Introduction: Previously, in vivo kinematic studies have determined the in vivo kinematics of the femur relative to the metal base-plate. These kinematic studies have reported posterior femoral rollback in posterior stabilized (PS) TKA designs, but the actual time of cam/post engagement was not determined. The objective of this present study was to determine, under in vivo conditions, the time of cam/post engagement and the kinematics of the femur relative to the polyethylene insert.

Methods: Femorotibial contact positions for twenty subjects having a PS TKA, implanted by two single surgeons, were analyzed using video fluoroscopy. Ten subjects were implanted with a PS TKA that is designed for early cam/post engagement (PSE) and ten subjects with a PS TKA designed for later cam/post engagement (PSL). Each subject, while under fluoroscopic surveillance, performed a weight-bearing deep knee bend to maximum flexion. Video images were downloaded to a workstation computer and analyzed at ten-degree increments of knee flexion. Femorotibial contact paths for the medial and lateral condyles, axial rotation and condylar lift-off were then determined using a computer automated model-fitting technique.

Results: Subjects implanted with the PSE TKA experienced, on average, the cam engaging the post at 48° (10 to 80°). Subjects having the PSL TKA experienced more consistent results and did experience engagement in deep flexion (Average 75°). Subjects having the PSE TKA experienced, on average, −5.5 mm (1.5 to −9.3) of posterior femoral rollback (PFR), while subjects having the PSL TKA experienced only −2.6 mm (8.5 to −9.0) of PFR. Subjects having the PSE TKA experienced more normal axial rotation patterns. Nine subjects having the PSE TKA experienced condylar lift-off (maximum = 1.9 mm), while only 4/10 having the PSL TKA experienced condylar lift-off (maximum = 2.7 mm).

Discussion: This is the first study to determine the in vivo contact position of the cam/post mechanism. Subjects having a PSE TKA experienced earlier cam/post engagement than subjects having the PSL TKA. Some subjects did not experience any cam/post engagement throughout knee flexion. Subjects having the PSE TKA experienced more PFR and better axial rotation patterns, but subjects having a PSL TKA experienced lesser incidence of condylar lift-off. Results from this study suggest that there may be an advantage to early cam/post engagement, which leads to more normal axial rotation patterns caused by the medial condyle moving in the anterior direction as the lateral condyle rolls in the posterior direction.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 407 - 407
1 Apr 2004
Komistek R Dennis D Mahfouz M Hoff W Haas B Anderson D
Full Access

Introduction: Understanding the in vivo motions of human joints has become increasingly important. Researchers have used in vitro (cadavers), non-invasive (gait labs), and in vivo (RSA, fluoroscopy) approaches to assess human knee motion. The objective of this study was to use fluoroscopy and computer tomography (CT) to accurately determine the 3D, in vivo, weight-bearing kinematics of normal knees.

Methods: Five normal knees clinically assessed as having no pain or ligamentous laxity were analyzed. Using CT scanning, slices were obtained six inches proximal to the joint line on the femur and six inches of the proximal tibia. Three-dimensional CAD models of each subject’s femur, tibia and patella were recreated from the 3D bone density data. Each subject was then asked to perform five weight-bearing activities while under fluoroscopic surveillance: (1) deep knee bend, (2) normal gait, (3) chair rise, (4) chair sit, and (5) stair descent. The computer-generated 3D models of each subject’s femur and tibiaon (> 1


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 17 - 17
1 Jan 2004
Stulberg S Anderson D Adams A Brander V Myo G Bernfield J Wixson R
Full Access

Pelvic osteolysis secondary to polyethylene wear is a major complication following THR. Identification of implant specific characteristics associated with osteolysis is essential. The purpose of this study is to compare incidence of CT scan identifiable osteolysis in 2 groups of young, active patients following THR; one with multi-holed acetabular shells with screws, one with cups without screw holes.

Between 1990–1993, 77 patients (85 hips) underwent THR with a cementless titanium, multi-holed shell with screws, modular, compression molded polyethylene and an uncemented titanium femoral stem. Average follow-up: 9 years, average age at surgery: 51 years. Between 1984–1987, 163 patients (183 hips) underwent THR with a cementless cobalt-chrome, solid shell, modular, heat-pressed polyeth-ylene liner and uncemented cobalt-chrome femoral stem. Average follow-up: 16 years, average age at operation: 52 years. All polyethylene was irradiated in air. At most recent follow-up, CT scans with metal suppression software was obtained to evaluate incidence of pelvic osteolysis. Patients classified: Group 1-no osteolysis, Group 2-cavitary osteolysis, Group 3-segmental osteolysis.

Patients with titanium, multi-holed shells had: Group 1-50.0%, Group 2-38.7%, and Group 3-11.3%. Patients with cobalt-chrome, solid shells had: Group 1-59.3%, Group 2-33.3% and Group 3-7.4%.

Although the patients with solid cups had much longer follow-up, less secure capture mechanism, less congruency between polyethylene and shell, and heat-pressed polyethylene, the incidence and extent of pelvic osteolysis was less than in the patients with multi-holed shell with screws. The presence of 6.5 mm cancellous screws is a serious independent risk factor for pelvic osteolysis following THR.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 6 - 6
1 Jan 2004
Argenson J Dennis D Komistek R Anderson D Anderele M
Full Access

The objective of this present study was to determine the in vivo kinematic patterns for subjects implanted with a patellofemoral arthroplasty (PFA).

Twenty subjects, all having a PFA, were studied (< 2 years post-op) under fluoroscopic surveillance to determine patellofemoral contact positions, sagittal plane, and medial/lateral translation using a skyline view.

The patellofemoral contact patterns for each subject having a PFA was highly variable, 11.9 mm of translation. The average amount of patella rotation during the full flexion cycle was 26.3 degrees, while one subject experienced 48.6 degrees. The average amount of medial/lateral translation was 3.8 mm (5 > 5 mm). Five subjects experienced grater than 5 mm of motion.

This was the first study to ever determine the in vivo kinematics for subjects having a PFA and the in vivo medial/lateral translation patterns of the patellofemoral joint. Subjects in this study experienced high variability and some abnormal rotational patterns. Most of the subjects who underwent PFA in this study had a previous history of subluxed or dislocated patella which affects the normal patella tracking, especially regarding tilting and translation. This tracking may also be directly affected by patellofemoral conformity, a consequence of femoral implant design. Finally, after PFA the patello-tibial tilt angle is influenced by the anteroposterior positioning of the femoral component.

The results of this very first in vivo kinematic study may play an important role, not only for design consideration of patellofemoral replacement but also for surgical technique in order to obtain optimal implant positioning.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 6 - 6
1 Jan 2004
Argenson J Komistek R Dennis D Anderson D Langer T
Full Access

The objective of the present study was to analyse kinematics of subjects having a UKA during stance phase of gait, where the ACL was intact at the time of the operative procedure.

Femorotibial contact positions for nineteen subjects (15 medial UKA (MUA); 14 lateral UKA (LUA); HSS > 90, post-op > 3 yrs) were analysed using video fluoroscopy.

During stance-phase of gait, on average, subjects having a medial UKA experienced 0.8 mm of anterior motion (7.7 to – 2.3 mm), while subjects having a lateral UKA experienced −0.4 mm (0.9 to – 2.1 mm) of posterior femoral rollback (PFR). Eight of 15 subjects having a medial UKA and two out of four lateral UKA experienced PFR. Eight of 15 subjects having a medial UKA experienced normal axial rotation (average = 0.9 degrees) and one out of four subjects having a lateral UKA experienced normal axial rotation (average = −6.0 degrees).

High variability in the kinematic data for subjects experiencing an anterior slide and opposite axial rotation suggests that these subjects had an ACL that was not functioning properly and was unable to provide an anterior constraint force with the necessary magnitude to thrust the femur in the anterior direction at full extension. Progressive laxity of the ACL may occur over time, and at least in part, lead to premature polyethylene wear occasionally seen in UKA. Our results support the findings of other studies that the ACL plays a significant role in maintaining satisfactory knee kinematics, which may also, in part, contribute to UKA longevity.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 6 - 6
1 Jan 2004
Komistek R Dennis D Anderson D Haas B
Full Access

The objective of this present study is to conduct a comparative analysis of the kinematic data derived for all subjects having a TKA who were analysed over the past eight years at our laboratory.

Femorotibial contact positions for 705 subjects having either a fixed bearing PCR or PS TKA or mobile bearing TKA were analysed in three-dimensions using video fluoroscopy.

During a deep knee bend, all PS TKA types subjects experienced a medial pivot motion, averaging −3.8 of lateral condyle posterior femoral rollback (PFR), respectively. Subjects having a fixed bearing PCR TKA experienced only −0.7 mm of lateral condyle PFR and an anterior slide of 1.6 mm for the medial condyle. Twenty-nine percent of the PCR TKA analysed had a lateral pivot and 71% experienced a medial pivot. Subjects having a mobile bearing TKA experienced −2.8 mm of lateral condyle PFR and 0.4 mm of medial condyle anterior slide. Fifty-one percent of the moble bearing implants experienced a medial pivot and 43% experienced a lateral pivot. During gait, PS and PCR fixed bearing TKA types experienced similar kinematic patterns. Subjects having a mobile bearing TKA experienced minimal motion, probably due to the mobile bearing TKA having greater sagittal conformity and had the lowest standard deviation.

There was great variability in the data comparing various TKA designs. Subjects in this multicentre analysis predominantly experienced a medial pivot motion, although certain TKA designs did demonstrate a lateral pivot motion.