Due to increasing interest into taper corrosion observed primarily in hip arthroplasty devices with modular tapers, efforts towards characterizing the corrosion byproducts are prevalent in the literature [1–4]. As a result of this motivation, several studies postulate cellular induced corrosion due to the presence of remarkable features in the regions near taper junction regions and articulating surfaces [3–5]. Observations made on explanted devices from a retrieval database as well as laboratory tests have led to the alternative proposal of electrocautery-electrosurgery damage as the cause of these features. These surgical instruments are commonly used for hemostasis or different degrees of tissue dissection. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to evaluate the features observed on retrieved devices. Retrieved devices consisted of OXINIUM and cobalt-chromium-molybdenum (CoCrMo) femoral implants, a Titanium-alloy hip stem, and a CoCrMo metal-on-metal femoral head. Electrocautery-electrosurgery damage was created using a SurgiStat II (Valleylab, Colorado) onto various components (CoCrMo, OXINIUM femoral heads as well as Ti-6Al-4V and CoCrMo alloy test stem constructs). Test components were evaluated using the same methods as the retrieved devices.INTRODUCTION
METHODS
Corrosion in modular taper connections of total joint replacement has become a hot topic in the orthopaedic community and failures of modular systems have been reported. The objective of the present study was to determine in vivo titanium ion levels following cementless total hip arthroplasty (THA) using a modular neck system. A consecutive series of 173 patients who underwent cementless modular neck THA and a ceramic on polyethylene bearing was evaluated retrospectively. According to a standardized protocol, titanium ion measurements were performed on 67 patients using high-resolution inductively coupled plasma-mass spectrometry. Ion levels were compared to a control group comprising patients with non-modular titanium implants and to individuals without implants. Although there was a higher range, modular-neck THA (unilateral THA: 3.0 μg/L (0.8–21.0); bilateral THA: 6.0 μg/L (2.0–20.0)) did not result in significant elevated titanium ion levels compared to non-modular THA (unilateral THA: 2.7 μg/L (1.1–7.0), p = 0.821; bilateral THA: 6.2 μg/L, (2.3–8.0), p = 0.638). In the modular-neck THA group, patients with bilateral implants had significantly higher titanium ion levels than patients with an unilateral implant (p < 0.001). Compared to healthy controls (0.9 μg/L (0.1–4.5)), both modular THA (unilateral: p = 0.029; bilateral p = 0.003) and non-modular THA (unilateral: p < 0.001; bilateral: p < 0.001) showed elevated titanium ion levels. The data suggest that the present modular stem system does not result in elevated systemic titanium ion levels in the medium term when compared to non-modular stems. However, more outliner were seen in modular-neck THA. Further longitudinal studies are needed to evaluate the use of systemic titanium ion levels as an objective diagnostic tool to identify THA failure and to monitor patients following revision surgery.
The use of tapered junctions in primary hip arthroplasty has excellent results. Large heads are being used to mitigate dislocation and optimize range of motion. The prevalence of larger heads, coupled with recent findings regarding corrosion artifacts at tapered surfaces, has spurred growing interest when considering revision rates. The purpose of this study was to determine if correlations exist between severity of corrosion artifacts and head size, head offset, time Retrieved hip arthroplasty devices with CoCrMo or oxidized zirconium (OxZr) heads were investigated for corrosion artifacts in this study. Female tapered surfaces were scored independently by a panel according to the Goldberg system for assessment of corrosion. Exclusion criteria included less than 1 week INTRODUCTION:
METHODS:
Total Hip Arthroplasty (THA) in patients after proximal femoral osteotomy remains a major challenge. Inferior survival for both cementless and cemented THA has been reported in this subgroup of patients. We retrospectively evaluated the clinical and radiographic results of a consecutive series of 48 THAs (45 Patients) who had undergone conversion THA for failed intertrochanteric osteotomy after a mean of 12 years (2–33 years) using a cementless, grit-blasted, double-tapered femoral stem. Mean follow-up was 20 years (range, 15–25 years), mean age at surgery was 47 years (range, 13–55 years). Clinical results were evaluated using the Harris Hip Score. Kaplan-Meier survivorship analysis was performed to determine long-term outcomes for different end points.Introduction
Methods
In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the reliability and accuracy of predicting three-dimensional (3-D) FO as measured on computed tomography (CT) from measurements performed on standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs and corresponding CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 29-57) kg/m2) with primary end-stage hip osteoarthritis were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding AP pelvis radiographs and CT scans. Inter- and intra-observer reliability of the measurement methods were evaluated using intra-class correlation coefficients (ICC). To predict 3-D FO from AP pelvis measurements, the entire cohort was randomly split in two groups and gender specific linear regression equations were derived from a subgroup of 250 patients (group A). The accuracy of the derived prediction equations was subsequently assessed in a second subgroup of 100 patients (group B). In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. FO was underestimated by 14% on AP pelvis radiographs compared to CT (5.4mm, 95%CI: 4.8-6.0mm, p<0.001) and both parameters demonstrated a linear correlation (r=0.642, p<0.001). In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The results of the present study suggest that femoral offset can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating and may improve offset and limb length restoration in THA without the routine performance of CT.
In uncemented total hip arthroplasty (THA), the optimal femoral component should allow both maximum cortical contact with proximal load transfer and accurate restoration of individual joint biomechanics. This is often compromised due to a high variability in proximal femoral anatomy. The aim of this on-going study is to assess the variation in proximal femoral canal shape and its association with geometric and anthropometric parameters in primary hip OA. In a retrospective cohort study, AP-pelvis radiographs of 98 consecutive patients (42 males, 56 females, mean age 61 (range:45-74) years, BMI 27.4 (range:20.3-44.6) kg/m2) who underwent THA for primary hip OA were reviewed. All radiographs were calibrated and femoral offset (FO) and neck-shaft-angle (NSA) were measured using a validated custom programme. Point-based active shape modelling (ASM) was performed to assess the shape of the inner cortex of the proximal femoral meta- and diaphysis. Independent shape modes were identified using principal component analysis (PCA). Hierarchical cluster analysis of the shape modes was performed to identify natural groupings of patients. Differences in geometric measures of the proximal femur (FO, NSA) and demographic parameters (age, height, weight, BMI) between the clusters were evaluated using Kruskal-Wallis one-way-ANOVA or Chi-square tests, as appropriate. In the entire cohort, mean FO was 39.0 mm, mean NSA was 131 degrees. PCA identified 10 independent shape modes accounting for over 90% of variation in proximal femoral canal shape within the dataset. Cluster Analysis revealed 6 shape clusters for which all 10 shape modes demonstrated a significantly different distribution (p-range:0.000-0.015). We observed significant differences in age (p=0.032), FO (p<0.001) and NSA (p<0.001) between the clusters. No significant differences with regard to gender or BMI were seen. Our preliminary analysis has identified 6 different patterns of proximal femoral canal shape which are associated with significant differences in femoral offset, neck-shaft-angle and age at time of surgery. We are currently evaluating the entire dataset of 345 patients which will allow a comprehensive classification of variation in proximal femoral shape and joint geometry. The present data may optimise preoperative planning and improve future implant design in THA.
Up to date there are only few reports in literature on the long term survival of uncemented stems. As for cemented THA, 10 year survival of at least 90% is required for any THA. We followed the first 354 consecutive implantations of an uncemented, straight femoral stem (CLS, Zimmer Inc, Warsaw, USA) in 326 patients. Mean time of follow-up evaluation was 17 years (range, 15-20 years).Introduction
Materials and methods
Periprosthetic tibial plateau fractures (PTPF) represent a rare but serious complication in unicompartmental knee arthroplasty (UKA). Although excellent long-term results have been reported with cemented UKA, surgeons continue to be interested in cementless fixation. The aim of the study was to compare fracture loads of cementless and cemented UKA. Tibial components of the Oxford UKA were implanted in six paired fresh-frozen tibiae. In one set surgery was performed with cement fixation and in the other cementless components were implanted. Loads were then applied under standardised conditions to fracture the specimens. Mean loads of 3.6 (0.7–6.9) kN led to fractures in the cemented group, whereas the tibiae fractured in the cementless group with a mean load of 1.9 (0.2–4.3) kN (p<
0.05). The loading capacity in tibiae with cementless components is significantly less compared to cemented fixation. Our results suggest that, patients with poor bone quality who are treated with a cementless UKA are at higher risk for periprosthetic fractures.
Between BMI and the maximum fracture loads inducing tibial plateau fractures a significant correlation could be proven for all tibiae (r=0.643).
We recommend special training and modified instruments for inexperienced surgeons to minimize the incidence of extended vertical saw cuts and to reduce the risk of periprosthetic fractures.
Radiolucent lines (RL) are a common radiographic finding following Oxford Uni knee arthroplastv. These RL are commonly seen at the bone-cement interface under the tibial tray and can only be evaluated using screened radiographs. These lines occur during the first year, are well defined and remain constant for years. The clinical relevance of this phenomenon is unclear. Pulse lavage has the potential to thoroughly clean the trabecular bone by clearing the bone from bone marrow and debris and can thereby facilitate cement penetration and interdigitation into trabecular bone. Pulse lavage can reduce the occurrence of radiolucent lines under the tibial tray by improving cement penetration and interdigitation. Since 2001 we routinely use pulse lavage before cementing the Oxford uni implants at the Orthopä-dische Universitätsklinik Heidelberg (group A). At Nuffield Orthopeadic Center, Oxford conventional irrigation has been used before cementing (group B). At a minimum follow-up of 1 year 56 screened AP radiographs of the knee after Oxford UCA have been blinded and evaluated for radiolucency and cement penetration by an independent observer. For standardized evaluation the cement bone interface has been devided into 4 zones and a specific algorithm for evaluation of the radiographs has been developed. Complete radiolucencies were detected in 2 cases (4%) in group A and in 13 cases (23%) in group B (p=0,001). Partial radiolucent lines were seen in 32 knees of group A (57%) and in 40 knees (71%) in group B. In zone 1 RLs were found in 31 tibias (55%) in group A, in 32 tibias (57%) in group B. In zone 2 17 (30%) group A, 29 (52%) group B. In Zone 3 4 (7%) in Gruppe A, 20 (36%) in group B. In Zone 4 6 (11%) group A, 30 (54%) group B. The differences between group A and B were significant (P=0.001) in zones 2, 3 and 4. In group A in 14 cases (25%) RL were limited to one zone, in group B in 5 cases (9%), respectively. In 12 cases (21%) 2 zones were affected in group A (12 cases (21%) group B). RLs in 3 zones were found in 4 cases (7%) in group A and in 10 cases (18%) in group B. Mean cement penetration (mm) was 2,3mm in group A and in 1,4mm in group B. The use of pulsed lavage led to an increase in cement penetration by a factor of 1,6 (cement penetration in group A/B zone 1: 1,4mm/0,8mm; zone 2: 2,4mm/1,5mm; zone 3: 1,4mm/0,7mm; zone 4: 4,0mm/2,4mm). The use of pulsed lavage significantly decreases the appearance of RLs at a minimum of 1 year follow-up by increasing cement penetration into cancellous bone. Even though the clinical relevance of tibial RLs in unclear we recommend the use of pulse lavage to improve cement penetration and interdigitation with cancellous bone. Unnecessary revisions due to misinterpretation of RLs may be prevented.
Background: In anteromedial osteoarthritis, only the medial compartment of the knee is affected and the collateral ligaments as well as the cruciate mechanism are intact. These preconditions make the knee suitable for UKA. The operative technique of the Oxford UKA theoretically allows the surge on to replicate the natural kinematics of the knee, due to accurate ligament balancing and fully congruent meniscal bearing design of the prosthesis. Our hypothesis was that no difference in tibiofemoral kinematics is observed after UKA. In addition we also hypothesised that the results of the image guided surgery would be the same as the normal surgical procedure.