Financial impact and patient satisfaction with four different anticoagulants for hip and knee arthroplasty in patients with a previous history of VTE- A prospective
Total hip arthroplasty (THA) is undertaken to relieve pain and to restore mobility. The orthopaedic community remains divided on the influence of surgical approach in achieving functional recovery most quickly and effectively. We report a study comparing THA performed through a posterior (Posterior) against anterior approach (Heuter). Fifty patients were prospectively enrolled and randomized for Posterior or Heuter procedures. Informed patient consent and local ethics approval was obtained. All patients received an uncemented, ceramic-on-ceramic prosthesis performed by a single surgeon. Functional outcome was assessed by time to achieve milestones of walking, stair climbing, hip movement and balance. Kinematic data on level-ground walking and the effect of fatigue was assessed using a portable gait analysis system at 6-, 12-, and 24-weeks post-operatively.Introduction
Methods
Objectives. Accurate characterisation of fractures is essential in fracture management trials. However, this is often hampered by poor inter-observer agreement. This article describes the practicalities of defining the fracture population, based on the Neer classification, within a pragmatic multicentre
There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a
Introduction. High flexion knee arthroplasties have been designed to allow up to 155 degrees flexion and enable high flexion activities such as kneeling and squatting. To date
Introduction. Many prosthetic design changes have been introduced in attempt to improve outcomes following TKA; however there is no consensus as to whether these changes confer benefits to patients. This study aimed to assess whether patients treated with a modern implant design had an enhanced patient outcome compared to a traditional model in a double blind
Introduction. The aims of this study were to undertake a prospective
Platelet rich plasma has been advocated for the treatment of plantar fasciitis but there are few good quality clinical trials to support its use. We report a pilot double blind
Objectives. Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the wound healing efficacy and patient satisfaction scores of both techniques in the same knee. Methods. We randomised 70 patients who underwent primary TKA into two groups. In one group of 34 patients, the skin at the upper half of the wound was closed with skin staples and the lower half of the wound was closed with simple interrupted nylon sutures. In the other group of 36 patients, the skin at the upper half of the wound was closed with nylon stitches and the lower half of the wound was closed with skin staples. We recorded the wound closure time, pain score at the time of stitch removal, wound complication rate, patient satisfaction score, and the Hollander wound evaluation score at the post-operative periods of five days, 14 days, six weeks, three months, and six months. Each half wound was analysed separately. Results. The mean patient body mass index was 26.8 kg/m. 2. (standard deviation 6.3). A total of 70 nylon stitched wounds and 70 skin stapled wounds were analysed. There were no significant differences in wound complication rates, patient satisfaction score, and the Hollander wound evaluation score between both types of wounds (p > 0.05). The wound closure time for skin stapled wounds was significantly lower than the nylon stitched wounds (p < 0.001). However, the skin stapled wounds had a significantly higher pain score at the time of stitch removal (p < 0.001). Conclusion. Skin staples and nylon stitches had comparable results with respect to wound healing and patient satisfaction in TKA wound closure in non-obese patients. The benefit of skin staples over nylon stitches was a decrease in operative time, but was more painful upon removal. Cite this article: V. Yuenyongviwat. A
Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20. Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID's for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12Introduction
Methods
We report our five-year functional results comparing navigated and conventional total knee replacement. To our knowlege this represents the first Level 1 study comparing function in navigated and conventional total knee replacement at five years. An origianl cohort of 71 patients undergoing Duracon (Stryker Orthopaedics, St. Leonards, Australia) total knee replacement without patellar resurfacing were prospectively randomised to undergo operation using computer navigation (Stryker Image Free Computer Navigation System (version 1.0; Stryker Orthopaedics))(n=35) or a jig-based method (n=36). The two groups were matched for age, gender, height, weight, BMI, ASA grade abd pre-operative deformity. All operations were performed by a single surgeon. Reviews were undertaken by senior physiotherpist blinded to participant status using validated outcome scoring tools (Knee Society Score, WOMAC Score and Short Form SF-36 Score). All patients underwent CT scanning of the implanted prosthesis as per Perth CT Knee Protocol to assess component alignment. After 5 years 24 patients in the navigated group and 22 patients in the conventional group were available for review. At 5 years no statistically significant difference was seen in any of the aforementioned outcome scores when comparing navigated and conventional groups. No statistically significant differencewas seen between 2- and 5-year results for either group. Due to the relatively low numbers in each group these data were compared with retrospective cohorts of navigated (n=100) and conventional (n=70) Duracon total knee replacements performed outwith this study over the same 5-year period. WITHIN the retrospective cohorts no statistically significant differences were found when comparing any of the aforementioned outcome scores. In addition, when comparing parallel scores between prospective and retrospective groups again no statistically significant differences were identified. At 5-years post-operatively the functional outcome between computer navigated and conventional total knee replacement appears to be no different despite the better alignment achieved using navigation.
Debate continues regarding the relative advantages of ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP) articulations in total hip arthroplasty (THA). Perceived benefits of CoC include longevity, and low wear - in turn limiting the effects of particulate wear debris. However, CoC bearings cost significantly more, and concern remains over the risk of ceramic fracture; a complication not seen with MoP bearings, which are also cheaper. We electronically randomised 268 consecutive patients undergoing THA to receive either a CoC or MoP articulation. Patients aged over 72 were excluded. In all patients the prosthesis used was an uncemented ABG II (Stryker, USA), implanted by one of the two senior authors (HDA, ABM). Patients were scored preoperatively, and at annual follow-up clinics, using SF36, Visual Analogue (VAS), Merle d'Aubigné (MD) and Oxford Hip (OHS) Scores. Satisfaction levels were also documented.Introduction
Method
Increasing knee flexion following total knee arthroplasty (TKA) has become an important outcome measure. Surgical technique is one factor that can influence knee motion. In this study, it was hypothesised that stripping of the posterior knee capsule could improve flexion and range of motion (ROM) following TKA. Patients who were undergoing TKA were prospectively randomised into two groups - one group (62 patients) were allocated stripping of the posterior knee capsule (PCS), the other group (66 patients) no stripping (no-PCS). The primary outcome was change in flexion and ROM compared to pre-operative measurements at three time points; after wound closure, 3months and 1year post-operatively. Secondary outcomes were absolute measurements of flexion, extension, ROM and complications. All operations were performed by a single surgeon using the same implant and technique. All patients received identical post-operative rehabilitation. There was a significant gain in flexion after wound closure in the PCS group (p=0.022), however there was no significant difference at 3months or 1year post-operatively. Absolute values of extension (p=0.008) and flexion (p=0.001) 3months post-operatively were significantly reduced for the PCS group. The absolute value of ROM was significantly higher for the no-PCS group at 3months (p=0.0002) and 1year (p=0.005). There were no significant difference in the rate of complications. Posterior capsular stripping causes a transient increase in flexion that does not persist post-operatively. We do not recommend routine stripping of the posterior knee capsule in patients undergoing TKA.
Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less systemic adverse effects, and promising results have been reported in systematic reviews of its use in spine surgery. This study aims to analyse the efficacy and adverse effect profile of intra-wound antibiotics in reducing surgical site infections in orthopaedic surgery for traumatic pelvic and lower limb fractures. A systematic review was conducted for studies reporting on the incidence of surgical site infections following administration of intra-wound antibiotic powder in pelvic and lower limb trauma surgery. Randomised controlled trials, cohort and case-control studies were included. A meta-analysis was conducted for deep surgical site infections. Seven studies were included in the systematic review including six retrospective case-control studies and one
This single-centre prospective
Purpose. Cognitive Muscular Therapy (CMT) is a new treatment for low back pain which integrates psychological techniques for pain management alongside training to improve postural control. Rather than focus on postural alignment or strength, CMT aims to improve the regulation of postural tone (low-level activity which supports the body against gravity). This is achieved by teaching patients an awareness of compensatory paraspinal activation, which can be triggered by overactivity of the abdominal muscles. The aim of this study was to understand whether CMT could reduce symptoms associated with low back pain and improve paraspinal muscle activation. Methods and results. Fifteen patients with chronic low back pain received seven weekly sessions of CMT from a physiotherapist. Clinical data was captured at baseline and two weeks after the intervention using the Roland-Morris questionnaire and the pain catastrophising scale. Activation of the erector spinae muscle during walking was also measured at baseline and after the final intervention session. Change data were analysed using paired t-tests. There was a 75% reduction (p<0.001) in the Roland-Morris score from a mean (SD) of 9.3(2.9) to 2.3(2.6), along with a 78% reduction in pain catastrophising (p<0.002) from 16.6(13) to 3.7(4.8). Activation of the contralateral erector spinae muscles reduced by 30% (p<0.01) during the contralateral swing phase of walking. Conclusion. In this small sample, CMT delivered large clinical improvements and reduced activation of the low back muscles during walking. Larger