Advertisement for orthosearch.org.uk
Results 1 - 20 of 96
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 78 - 78
1 May 2012
Smitham P Molvik H Smith K Attard J Cullen N Singh D Goldberg A
Full Access

Introduction. There are approximately 1.2 million patients using orthotics in the UK costing the NHS in excess of £100 million per annum. Despite this, there is little data available to determine efficacy and patient compliance. There have been a few reports on patient satisfaction, which indicate that between 13-50% of patients are dissatisfied with their orthotics. Our aim was to evaluate patient reported satisfaction with orthotics prescribed and to investigate the reasons behind patient dissatisfaction. Methods. Seventy consecutive patients receiving foot orthoses at the Royal National Orthopaedic Hospital were retrospectively asked to complete a questionnaire and to bring their shoes and orthotics to research clinic. The inside width of the shoes and corresponding width of the orthotic were measured. A semi-structured interview was carried out on 10 patients, including those that were satisfied or unsatisfied, using qualitative research methods to identify issues that are important to patients. Results. Forty out of 70 patients (57%) completed the questionnaire either by telephone or in the clinic. There was a statistically significant difference between the width of the orthotics and the inside diameter of the shoes that the orthotic was meant to fit in. Dissatisfaction with the new custom made insoles was reported in 28% of patients. Half of these patients reported that the insoles did not fit with their feet into their shoes, and 30% indicated a preference for cosmetic issues over function. The majority of patients had tried numerous homemade or off the shelf versions prior to attending the orthotic department. Conclusion. There is a high level of patient dissatisfaction with orthotics. This dissatisfaction was due to a disconnection between prescribed foot orthoses and shoes purchased by patients. There is an urgent need to join up these two industries to prevent financial waste and improve the cost-effectiveness of orthotic services


Aims. To systematically review the efficacy of split tendon transfer surgery on gait-related outcomes for children and adolescents with cerebral palsy (CP) and spastic equinovarus foot deformity. Methods. Five databases (CENTRAL, CINAHL, PubMed, Embase, Web of Science) were systematically screened for studies investigating split tibialis anterior or split tibialis posterior tendon transfer for spastic equinovarus foot deformity, with gait-related outcomes (published pre-September 2022). Study quality and evidence were assessed using the Methodological Index for Non-Randomized Studies, the Risk of Bias In Non-Randomized Studies of Interventions, and the Grading of Recommendations Assessment, Development and Evaluation. Results. Overall, 17 studies (566 feet) were included: 13 studies used clinical grading criteria to report a postoperative ‘success’ of 87% (75% to 100%), 14 reported on orthotic use with 88% reduced postoperative use, and one study reported on ankle kinematics improvements. Ten studies reported post-surgical complications at a rate of 11/390 feet (2.8%), but 84 feet (14.8%) had recurrent varus (68 feet, 12%) or occurrence of valgus (16 feet, 2.8%). Only one study included a patient-reported outcome measure (pain). Conclusion. Split tendon transfers are an effective treatment for children and youth with CP and spastic equinovarus foot deformities. Clinical data presented can be used for future study designs; a more standardized functional and patient-focused approach to evaluating outcomes of surgical intervention of gait may be warranted. Cite this article: Bone Jt Open 2023;4(5):283–298


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 495 - 495
1 Apr 2004
Eames M Traynor I Wallace R
Full Access

Introduction In this institution a structured program of conservative management of Achilles tendon rupture has been developed combining a conservative and orthotic treatment regime with a view to adding the advantages of a removable orthosis to traditional non-operative therapy. This study compares the results of this protocol to published surgical results. This is the largest detailed study of conservative management of Achilles tendon rupture in the literature to date. Methods We assessed 140 subjects who had a complete rupture of their Achilles tendon treated with our combined conservative and orthotic regime between 1992 and 1998. Subjective assessments of symptoms and objective measurements of ankle range of motion, calf circumference and isokinetic measurements of ankle plantar flexion and dorsi flexion were recorded. Patients also completed a functional heel-rise test. Our results have been compared to published series. Results Our overall results showed 56% had excellent, 30% good, 12% fair and two percent poor results. The overall complication rate was four percent, with three tendon reruptures. When compared with published results for operative repair, our combined conservative and orthotic treatment produces better results overall. Patients are subjectively happier, they have better strength results and have fewer complications. In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 225 - 225
1 May 2009
Moreau M Hill D Lou E Mahood J Raso J
Full Access

Brace correction based upon mechanical action requires appropriate interface pressure between the body and the brace. A smart orthotic was developed to record how much time (quantity) a brace was used, how well (quality) it was used and maintain the interface pressure to the prescribed level. Six subjects were recruited and they all used Boston style braces. Each subject used the system for two weeks without the force maintenance system activated to serve as the control period, and the remaining two weeks with the force maintenance system activated. During the automatic feedback mode, the pressure maintenance system was activated only during the daytime (8:00–22:00hrs) to avoid disturbing the patients during sleep. The subject could either return the system to us after one month or continue to use the system until the next clinic. The time that the pressure level was in the target level range during the study period was increased from 53 +/− 9% to 68 +/− 14% with the feedback activated. The average brace wear time for the study period was 72 +/− 15% (12.6hr/day) of the prescribed time (17.5 +/− 3.8 hours). The curve severity of all subjects on the following clinical visit was the same (within measurement error) as the first visit (32 +/− 5 vs 31 +/− 5 degrees). Compliance was not affected when wearing the monitor. The smart orthotic was able to improve the efficiency of a conventional brace by maintaining the prescribed interface pressure automatically. This proposed work helps brace candidates wear their braces more effectively and gets the most benefit from the brace treatment. As a result, all participated subjects maintained their Cobb angle within ± two degrees during the study period


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 582 - 582
1 Aug 2008
Khan WS Jones RK Nokes L Johnson DS
Full Access

Introduction: There has been an increasing use of orthotic knee braces in the management of knee injuries. To ensure the biomechanics of the knee are not adversely affected, it is important that orthotic knee braces accurately provide the desired angle of immobilisation. The objective of our study was to measure the actual knee flexion angles for a lockable orthotic knee brace, and measure the resulting knee flexion moment. Materials and methods: Eight healthy male volunteers participated in the study looking at six different types of knee immobilisation: locked in 0, 10, 20, 30 degrees of knee flexion, with the brace unlocked, and without a brace. Force and 3-dimensional motion data were collected using a single Kistler force plate and an eight-camera Qualisys ProReflex motion analysis system. Results: The kinematic knee flexion angles were significantly different when compared with the angles set at the orthotic knee brace for 0 degrees (p=0.001) and 10 degrees (p=0.011). The kinematic knee flexion angle when no brace was used was significantly different from the angle for the unlocked orthotic knee brace (p= 0.003). The knee flexion moment was directly proportional to the knee flexion angle. There was a statistically significant difference between the knee flexion moment for the six types of immobilisation (p< 0.001). Discussion: The knee flexion angles measured using the kinematic data did not always correspond with the angle set at the orthotic knee brace. These findings highlight inadequacies in the design of lockable orthotic knee braces, especially at low flexion angles of 0 and 10 degrees. The resulting higher actual knee flexion angles were associated with greater knee flexion moments and joint reaction forces at the tibiofemoral and patellofemoral joints. This can, at best result in increased energy expenditure and decreased agility, and at worse potentially augment injuries to the knee


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 120 - 120
1 Feb 2003
Eames MHA Wallace RGH Traynor IER Kernohan GW Eames NWA
Full Access

This is the largest detailed study of conservative management of Achilles tendon rupture in the literature to date. We assessed 140 subjects who had a complete rupture of their Achilles tendon treated with our combined conservative and orthotic regime between 1992 and 1998. Subjects were assessed subjectively and objectively, including isokinetic measurements of ankle plantarflexion and dorsiflexion. Overall 56% had excellent, 30% good, 12% fair and 2% poor results. The complication rate was 4%, with only 3 tendon reruptures. When compared with published results for operative repair, our combined conservative and orthotic treatment produces better results overall. Patients are subjectively happier, they have better strength results and have fewer complications


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 482 - 482
1 Nov 2011
Akrawi H Bolland B Healey M Savva N Bowyer G
Full Access

Introduction: Functional Foot Orthoses (FFO’s) have been shown to improve one element of balance, postural sway, when prescribed for patients with ankle injuries. Little is known, however, about the effect of these devices on ankle stability/proprioception, or the changes which might occur as the patient becomes habituated to using the device. We studied these effects from the time of initial application of the FFO through to regular usage at six weeks. Methods: Patients with musculoskeletal conditions affecting the lower limb that required custom made FFO’s were evaluated. A standardised protocol, using the Biodex stability system (a balance platform), to assess several stability indices was performed. Patients were assessed before fitting the orthosis, at the time of fitting and six weeks later. The American Orthopaedic Foot and ankle Society (AOFAS) score was also used to evaluate the progress of these patients. Results: There were 13 male and seven female patients, aged 10 to 64 years. Patients had a range of orthopaedic conditions and all been assessed by orthopaedic specialist and podiatrist as having correctable foot biomechanics. In 6 patients, proprioception deteriorated on initial application of FFO’s. However, all patients exhibited improved over-all stability by a mean of 2.5 points (Normal range 0.82–3.35) at 6 weeks evaluation. The mean AOFAS on presentation was 72 and the final mean score was 97, both of which were clinically and statistically significant (t test, p< 0.05). Eighteen patients had complete resolution of symptoms of pain and instability. Conclusions: FFO’s alter foot biomechanics, and in doing so appear also to improve balance and proprioception. Proprioception deteriorated in 30% of cases on initial application of orthotics, but pain and instability improved in more than 90% of patients on extended use of foot orthotics, with this improvement becoming manifest by 6 weeks after starting use of the device


Bone & Joint Open
Vol. 1, Issue 12 | Pages 720 - 730
1 Dec 2020
Galloway AM van-Hille T Perry DC Holton C Mason L Richards S Siddle HJ Comer C

Aims. Perthes’ disease is a condition leading to necrosis of the femoral head. It is most common in children aged four to nine years, affecting around one per 1,200 children in the UK. Management typically includes non-surgical treatment options, such as physiotherapy with/without surgical intervention. However, there is significant variation in care with no consensus on the most effective treatment option. Methods. This systematic review aims to evaluate the effectiveness of non-surgical interventions for the treatment of Perthes’ disease. Comparative studies (experimental or observational) of any non-surgical intervention compared directly with any alternative intervention (surgical, non-surgical or no intervention) were identified from: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), EMcare, Allied and Complementary Medicine Database (AMED), and the Physiotherapy Evidence Database (PEDro). Data were extracted on interventions compared and methodological quality. For post-intervention primary outcome of radiological scores (Stulberg and/or Mose), event rates for poor scores were calculated with significance values. Secondary outcomes included functional measures, such as range of movement, and patient-reported outcomes such as health-related quality of life. Results. In all, 15 studies (1,745 participants) were eligible for inclusion: eight prospective cohort studies, seven retrospective cohort studies, and no randomized controlled trials were identified. Non-surgical interventions largely focused on orthotic management (14/15 studies) and physical interventions such as muscle strengthening or stretching (5/15 studies). Most studies were of high/unknown risk of bias, and the range of patient outcomes was very limited, as was reporting of treatment protocols. Similar proportions of children achieving poor radiological outcomes were found for orthotic management and physical interventions, such as physiotherapy or weightbearing alteration, compared with surgical interventions or no intervention. Conclusion. Evidence from non-randomized studies found no robust evidence regarding the most effective non-surgical interventions for the treatment of children with Perthes’ disease. Future research, employing randomized trial designs, and reporting a wider range of patient outcomes is urgently needed to inform clinical practice. Cite this article: Bone Jt Open 2020;1-12:720–730


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 9 - 9
1 Oct 2021
Scott-Watson M Adams S Dixon M Garcia-Martinez S Johnston M Adams C
Full Access

Success treating AIS with bracing is related to time worn and scoliosis severity. Temperature monitoring can help patients comply with their orthotic prescription. Routinely collected temperature data from the start of first brace treatment was reviewed for 14 patients. All were female with an average age of 12.4 years (range 10.3–14.6) and average 49o Cobb angle (30–64). Our current service recommendation is brace wear for 20 hours a day. Patients complied with this prescription 38.0% of the time, with four patients averaging this or more. Average brace wear was 16.3 hours per day (3.5–22.2). There were 13 patients who had completed brace treatment. The majority had surgery (7/13; 54%) or were considering surgery (1/13; 8%). There were 5 who did not wish surgery at discharge (5/13; 38%); 1 achieved a 40o Cobb angle, with 4 larger (53o;53o;54o;68o). The Bracing in AIS Trial (BrAIST) study measured “success” as less than a 50o Cobb angle, so using this metric our cohort has had a single “success”. Temperature monitors allowed an analysis of when patients were achieving their brace wear. When comparing daywear (8am-8pm) to nightwear (8pm-8am), patients wore their brace an average of 7.6 hours a day (2.5–11.2) and 8.7 hours a night (0.4–11.5). We conclude the minority of our patients comply with our current 20 hour orthotic prescription. The “success” of brace treatment is lower than comparison studies despite higher average compliance but starting with a larger scoliosis. Brace wear is achieved during both the day and night


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 73 - 73
17 Apr 2023
Condell R Flanagan C Kearns S Murphy C
Full Access

Despite considerable legacy issues, Girdlestone's Resection Arthroplasty (GRA) remains a valuable tool in the armoury of the arthroplasty surgeon. When reserved for massive lysis in the context of extensive medical comorbidities which preclude staged or significant surgical interventions, and / or the presence of pelvic discontinuity, GRA as a salvage procedure can have satisfactory outcomes. These outcomes include infection control, pain control and post-op function. We describe a case series of 13 cases of GRA and comment of the indications, peri, and post-operative outcomes. We reviewed all cases of GRA performed in our unit during an 8 year period, reviewing the demographics, indications, and information pertaining to previous surgeries, and post op outcome for each. Satisfaction was based on a binary summation (happy/unhappy) of the patients’ sentiments at the post-operative outpatient consultations. 13 cases were reviewed. They had a mean age of 75. The most common indication was PJI, with 10 cases having this indication. The other three cases were performed for avascular necrosis, pelvic osteonecrosis secondary to radiation therapy and end stage arthritis on a background of profound learning disability in a non-ambulatory patient. The average number of previous operations was 5 (1-10). All 13 patients were still alive post girdlestone. 7 (54%) were satisfied, 6 were not. 3 patients were diabetic. 5 patients developed a sinus tract following surgery. With sufficient pre-op patient education, early intensive physiotherapy, and timely orthotic input, we feel this procedure remains an important and underrated and even compassionate option in the context of massive lysis and / or the presence of pelvic discontinuity / refractory PJI. GRA should be considered not a marker of failure but as a definitive procedure that gives predictability to patients and surgeon in challenging situations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 8 - 8
16 May 2024
Giddie J Phyo N Reichert I Ahluwalia R Kavarthapu V
Full Access

Background. Corrective fusion of a deformed / unstable Charcot neuroarthropathy (CN)of the midfoot and hindfoot is performed with the aim to prevent ulcers and maintain patient mobility. Methods. Between October 2007 and July 2018, 103 CN mid and hind foot corrections in 95 patients were performed. There were 34 hind-foot, 38 mid-foot and 31 combined hind and mid-foot surgeries. 83 feet had single stage corrections, whereas 20 required a staged operation. Results. Ninety-five patients were prospectively followed up. The mean patient age in our study was 57 years (21 – 85). Twenty-seven patients had type1 diabetes, 64 patients had type 2 and 4 patients had a neuropathy secondary to other conditions. Forty patients (42%) were offered a below knee amputation prior to attending our foot clinic. At a mean follow up of 56 months (12 – 140) we achieved 100% limb salvage with a 75% full bone fusion rate. There were 17 mortalities within our cohort at a mean period of 3 years. Ninety-seven percent (n=92) patients were mobilizing post-operatively in orthotic footwear. Fifty-two feet had pre-operative ulcers. Post-operatively 17 feet (16 patients) had persistent ulceration. Eight patients had ulcer resolution following further surgery and alteration of footwear, one patient has been listed for a below knee amputation for unstable non-union, whilst the remaining 7 patients have stable ulcers which are managed with dressings. Of the 26 feet (25 patients) with non-unions, 6 patients had revision fixation procedures whilst 8 patients required minor surgical procedures. The remaining 11 patients are stable non-unions who are asymptomatic and weight bearing. Other complications included a deep infection rate of 8% (n=7). Conclusion. We demonstrated a 100% limb salvage rate and an 83% success rate in ulcer resolution. We recommend this be done with the support of the multi-disciplinary team


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 11 - 11
3 Mar 2023
Mehta S Reddy R Nair D Mahajan U Madhusudhan T Vedamurthy A
Full Access

Introduction. Mode of non-operative management of thoracolumbar spine fracture continues to remain controversial with the most common modality hinging on bracing. TLSO is the device with a relative extension locked position, and many authors suggest they may have a role in the healing process, diminishing the load transferred via the anterior column, limiting segmental motion, and helping in pain control. However, several studies have shown prolonged use of brace may lead to skin breakdown, diminished pulmonary capacity, weakness of paraspinal musculature with no difference in pain and functional outcomes between patients treated with or without brace. Aims. To identify number of spinal braces used for spinal injury and cost implications (in a DGH), to identify the impact on length of stay, to ascertain patient compliance and quality of patient information provided for brace usage, reflect whether we need to change our practice on TLSO brace use. Methods. Data collected over 18-month period (from Jan.2020 to July 2021). Patients were identified from the TLSO brace issue list of the orthotic department, imaging (X-rays, CT, MRI scans) reviewed to confirm fracture and records reviewed to confirm neurology and non-operative management. Patient feedback was obtained via post or telephone consultation. Inclusion criteria- patients with single or multi -level thoracolumbar osteoporotic or traumatic fractures with no neurological involvement treated in a TLSO brace. Exclusion criteria- neurological involvement, cervical spine injuries, decision to treat surgically, concomitant bony injuries. Results. 72 braces were issued in the time frame with 42 patients remaining in the study based on the inclusion/exclusion criteria. Patient feedback reflected that 62% patients did not receive adequate advice for brace usage, 73% came off the brace earlier than advised, and 60% would prefer to be treated without a brace if given a choice. The average increase in length of stay was 3 days awaiting brace fitting and delivery. The average total cost burden on the NHS was £127,500 (lower estimate) due to brace usage. Conclusion. If there is equivalence between treatment with/without a brace, there is a need to rethink the practice of prescribing brace for all non-operatively treated fractures and a case-by-case approach may prove more beneficial


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 3 - 3
1 Dec 2022
Leardini A Caravaggi P Ortolani M Durante S Belvedere C
Full Access

Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and elbow surgery, in particular for pre-op planning and surgical guide design in complex re-alignment osteotomies for severe bone deformities. Also in complex flat-foot deformities, in preparation of surgical corrections, 3D digital reconstruction and 3D printing in cheap ABS filaments have been valuable, for indication, planning of surgery and patient communication; with special materials mimicking bone strength, these 3D physical models are precious also for training and preparation of the surgery. In Paediatric surgery severe multi planar & multifocal deformities in children are addressed with personalized pre-op planning and custom cutting-guides for the necessary osteotomies, most of which require custom allografts. A number of complex hip revision surgeries have been performed, where 3D reconstruction for possible final solutions with exact implants on the remaining bone were developed. Elective surgery has been addressed as well, in particular the customization of an original total ankle replacement designed at IOR. Also a novel system with a high-tibial-osteotomy, including a custom cutting jig and the fixation plate was tested. An initial experience for the design and test of custom ankle & foot orthotics is also in progress, starting with 3D surface scanning of the shank and foot including the plantar aspect. Clearly, for achieving these results, multi-disciplinary teams have been formed, including physicians, radiologists, bioengineers and technologists, working together for the same goal


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 3 - 3
1 Nov 2016
Li S Myerson M Monteagudo M
Full Access

Müller Weiss disease (MWD) is characterized by lateral navicular necrosis which is associated with a varus alignment of the subtalar joint, varying degrees of arthritis of the talonavicular-cuneiform joints and a paradoxical flatfoot deformity in advanced cases. Although arthrodesis of the hindfoot is commonly used, we present the results of a previously unreported method of treatment using a calcaneus osteotomy incorporating a wedge and lateral translation. Fourteen patients with MWD who were treated with a calcaneus osteotomy were retrospectively reviewed. There were seven females and seven males with an average age of 56 years (range 33–79), and included one grade 5, five grade 4, four grade 3 and four grade 2 patients. Patients had been symptomatic for an average of eleven years (range 1–14), and all underwent initial conservative treatment with an orthotic support that posted the heel into valgus. The primary indication for surgery was a limited but positive response to the use of the orthotic support, and a desire to avoid an arthrodesis of the hindfoot. Results. Patients were followed for an average of three years following the procedure (range 1 – 7 years). Patients rated their pain on a visual analogue pain scale as an average of 8 (range 6–9) prior to surgery and an average of 2 postoperatively (range 0–4). The AOFAS scores improved from a mean of 29 (range 25 – 35) preoperatively to a mean of 79 (range 75–88) postoperatively. Hindfoot range of motion remained and the extent of arthritis of the navicular complex was unchanged. No patient has since required an arthrodesis. Since the majority of MWD patients respond to an orthotic support which changes the load of the hindfoot and forefoot, we believed that patients would respond positively to a calcaneal osteotomy as an alternative treatment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 84 - 84
1 Mar 2013
Morkel D Dillon E Muller C Barnard J
Full Access

Purpose of study. To study the effect of different shoes and orthotics have on patellar tendon tensile forces. Patellar tendinopathy is an overuse injury that affects tennis players and in high impact sports like basketball, volleyball and running has an incidence of 20%. The tensile forces in the patellar tendon can be reliably measured with an intratendinously placed fibre optic tube and wireless transmission device allows for dynamic testing. The biggest strain differentials have been confirmed in jumps from 30cm height. Tennis is played on 3 major different court surfaces and there is a variety of commercially designed tennis shoes on the market. Materials and methods. 6 male tennis players, ages 18–49 were enrolled for this study. A fibre optic cannula was placed in the middle of the proximal pole of patella tendon from lateral to medial direction in the dominant knee. The patellar tendon tensile forces deform the fibre optic cannula in turn modulating the light signal passing through the optic cannula. The drag in the fibre optic sensor signal was used to measure the tensile forces in the patellar tendon. MLTS 700 goniometer were utilized to measure and record the amount of flexion with each jump to standardize results for different shoes and orthotics. Results. The results of patellar tendon tensile forces measurements for different players, different shoes and orthotics showed no trend or statistical difference for any particular shoe or orthotic. Conclusions. Fibre optic measurements of the effect of different shoes on patellar tendon tensile forces did not show a distinct advantage for any shoe above another. 1 DISCLOSURE


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 32 - 32
1 Jan 2011
Kearney R Dunn K Modi C Costa M
Full Access

A key factor delaying rehabilitation after a tendo Achillis (TA) rupture is gait abnormality. We quantified changes in planter pressures after a rupture of the TA in four groups of patients:. 15 controls subjects, mean 40 years, with no history of lower limb abnormality. 14 patients, mean 48 years, treated in a non-weight-bearing plaster cast. 12 patients, mean age 45 years, treated with immediate weight-bearing in a ‘rigid’ orthosis. 14 patients, mean age 51 years, treated with immediate weight-bearing in a ‘flexible’ orthosis. Mean and maximum peak planter pressures within the forefoot and heel were measured using in-shoe pressure pads two weeks after removal of the cast/orthosis; five gait cycles were recorded. The terminal stance and pre-swing phases were also measured as a proportion of the total stance phase of the gait cycle. One-way ANOVA was used to compare the difference in means between the groups. The normal control group had less than 2% difference between the limbs on all of the measured parameters. The patients in the plaster cast and ‘rigid’ orthotic groups had significant deficits (p = 0.04 and < 0.001 compared to control) in mean peak forefoot pressures, implying weakness in the triceps surae. However, the patients in the flexible orthosis group had only an 11% deficit (p = 0.25 compared to control). All of the patients treated for a TA rupture had increased heel pressures but only the ‘rigid’ orthotic group had cadence abnormalities (p = < 0.001). This may be the result of abnormal motor patterns secondary to mobilising in the rigid orthosis. This study highlights the gait abnormalities associated with triceps surae weakness following rupture of the TA. Accelerated rehabilitation using weight-bearing orthotics may alleviate some of these problems, but new designs for flexible orthotics may be required for maximum benefit


Daycase surgery has advantages for patients, clinicians and trusts. The Best Practice Tariff uplift is £200/case for Minor Foot Procedures performed as daycases. Before discharge, Foot & Ankle daycase procedures in Cheltenham General Hospital require physiotherapy assessment and frequently an orthotic aid. This audit analysed length of stay of daycase patients on a Foot and Ankle list. The standard was 100% of daycase patients to be discharged the same day. Length of stay for a consecutive series of patients was calculated for all daycase procedures from October to December 2010. An intervention was made comprising a weekly multidisciplinary bulletin from the Orthopaedic Consultant. This highlighted post-operative weight-bearing instructions and orthotic requirements for forthcoming daycase patients to physiotherapists, nursing staff and junior doctors. The data was compared with a second consecutive series of patients from October to December 2011. The first series included 38 listed daycases of which 61% (23 patients) were daycase discharges. The second series comprised 41 listed daycases who received pre-operative physiotherapy assessment and provision of required orthotic aids; 85% (35 patients) of this group were discharged the same day. Data analysis using Fisher's exact test reveals this intervention had a statistically significant impact on the number of patients discharged the same day (p < 0.0207). The financial implications are increased Best Practice Tariff with an £1800 uplift and reduction in the estimated cost of unnecessary overnight stays of £4640 over the 3 months. Improved multidisciplinary communication can significantly improve the patient experience, bed occupancy and cost of care


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 100 - 100
1 Feb 2012
Costa M Chester R Shepstone L Robinson A Donell S
Full Access

The aim of this study was to compare immediate weight-bearing mobilisation with traditional plaster casting in the rehabilitation of non-operatively treated Achilles tendon ruptures. Forty-eight patients with Achilles tendon rupture were randomised into two groups. The treatment group was fitted with an off-the-shelf carbon-fibre orthotic and the patients were mobilised with immediate full weight-bearing. The control group was immobilised in traditional serial equinus plaster casts. The heel raise within the orthotic and the equinus position of the cast was reduced over a period of eight weeks and then the orthotic or cast was removed. Each patient followed the same rehabilitation protocol. The primary outcome measure was return to the patient's normal activity level as defined by the patient. There was no statistical difference between the groups in terms of return to normal work [p=0.37] and sporting activity [p=0.63]. Nor was there any difference in terms of return to normal walking and stair climbing. There was weak evidence for improved early function in the treatment group. There was 1 re-rupture of the tendon in each group and a further failure of healing in the control group. One patient in the control group died from a fatal pulmonary embolism secondary to a DVT in the ipsilateral leg. Immediate weight-bearing mobilisation provides practical and functional advantages to patients treated non-operatively after Achilles tendon rupture. However, this study provides only weak evidence of faster rehabilitation


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 23 - 23
1 Mar 2006
Galli M Mancini L Pitocco D Ruotolo V Vasso M Ghirlanda G
Full Access

Aim: Evaluation of multifactorial treatment of Charcot foot disease in diabetic patients. Materials and Method: We followed 25 diabetic patients with Charcot foot in acute phase (Eichenholtz Stage I) from 2001 to 2003 (mean follow-up 22 months) admitted to the Day Hospital of Diabetology of the Catholic University of Rome. All patients presented a good vascularization (ABI > 0.9) and osteomielytis was excluded by means of 111Indium labelled leukocyte scintigraphy. Six patients presented a structural derangement localized to the forefoot (Pattern I according to Sanders and Frykberg Classification), one to the ankle (Pattern IV) and 18 to the mid-foot region (Pattern II and III). At first clinical evaluation, 13 patients presented a plantar monolateral ulcer. Their treatment was multifactorial. An offloading regimen was adopted, with the use of a total contact cast and crutches, in order to avoid weight-bearing on the affected foot for the first two months. Patients responsive to the treatment were successively treated with a pneumatic cast (Air cast) and partial weight-bearing for another four months. Four unresponsive patients underwent surgical treatment. 10 patients were also treated with alendronate (70 mg per os once a week). Three patients died during treatment and one during the follow-up, three of them for cardiovascular disease, one for bronchopneumopathy. Results: All patients reached the quiescent or chronic phase (Eichenholtz Stage III) at an average of six months from the onset of the treatment (range 3 to 9 months). No major or minor amputation was performed. Multifactorial treatment prevented the development ulcers in all patients that started the treatment without this complication (12 patients). 7 out of 13 ulcerated patients developed a recalcitrant ulcer (unresponsive to medical and orthotic treatment). 4 patients underwent surgical treatment: midfoot arthrodesis with Ilizarov external fixation (2 patients), rockerbottom deformity resection (one patient), Lelievre realignment (one patient). 3 patients healed after surgical treatment. Thus an overall amount of 9 out of 13 ulcerated patients healed after multifactorial treatment. Conclusions: Multifactorial treatment demonstrated effective in the management of Charcot foot in diabetic patients. Medical and orthotic treatment alone is effective in preventing complication throughout the natural history of the disease. Medical and orthotic treatment alone is frequently unsuccessful in treating plantar ulcers when major deformities has already developed. Medical and orthotic treatment combined with surgical treatment demonstrated an increased percentage of success


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 58 - 58
1 Dec 2020
Ranson J Nuttall G Paton R
Full Access

Aims & Background. Congenital Talipes Equinovarus (CTEV) is the most common congenital musculoskeletal birth defect affecting 1 in 1000 births per annum. We have compared our surgical results to the British Society of Children's Orthopaedics (BSCOS) published guidelines. Methods. Between, 2006–16, patients who were referred for treatment of pathological CTEV were audited. Data from a combination of Clinical Portal, Orthotic Patient Administration System and Surgical Elogbook were assessed. In addition, the degree of deformity was classified by the Harrold & Walker method at the time of diagnosis (senior author). Most of this information was recorded prospectively and analysed retrospectively. Ponseti technique was the method of treatment. Results. 96 patients assessed (133 feet). There were 78 males and 18 females, 37 patients were affected bilaterally and 11 had associated syndromes. There were 23 Harrold & Walker (H&W) 1, 28 H&W 2 and 82 H&W 3 classification feet. Average time period in Ponseti boots and bars was 14.4 months (95% CI 12.9–15.9), average time in all types of bracing of was 17.1 months (95% CI 14.8–14.8). Number and rate of surgeries performed were as follows: 77 Tendoachilles release (63.1%), 19 Tibialis Anterior Transfer (5.6%), 15 Radical Release (12.3%), revision 25 Surgery (20.5%) & 5 Abductor Hallucis Release (4.1%). Conclusion. The audit confirms that the unit meets most of the current BSCOS guidelines. All surgical procedures apart from radical release surgery fall within accepted limits. This may be due, in part, to the syndromal cases. We do however demonstrate a significantly reduced average time period in bracing compared to that recommended by BSCOS. There are multiple reasons for this discrepancy including non-compliance and poor splint tolerance (child refusing to use). We feel this work demonstrates a reduced period in bracing can be achieved whilst maintaining standards of treatment