Introduction. the aim of the study is to evaluate the clinical results of the shoulder prosthesis revision procedure to reverse implant without removing the humeral stem using a
Introduction. Numerous fixation modalities can be used for various indications, including deformity correction, trauma, infection, and non-union. The
We evaluated intermediate-term results of primary cementless Omniflex prostheses. Forty-nine patients (57 hips) with a mean age of 44 years were observed for an average of 8.6 years. These results were inferior to those using other recent cementless total hip systems. The increasing prevalence of loosening and osteolysis with time are problems related to this Omniflex femoral component. Although the implant design is unique, the authors no longer use this system.
Aim. To evaluate outcome and complications of knee arthrodesis with a
Introduction and Aims: Difficult primary and revision total knee arthroplasty (TKA) with constrained knee systems is becoming more common.
Introduction: The double threaded Cone
From 1992 on 2008, 615/515 patients underwent primary or revisional endoprosthetic replacement of major joints. In 51 patients (31 men &
20 women)
Aims: To investigate adequacy of temporary ex-fix in grade III open fractures of the tibia, prior to definitive treatment by Flap &
Frame at 2 UK trauma centres. Methods: Between 2000 and 2006 all open fractures of the tibia treated by the Ilizarov Method at our two institutions were entered onto the Flap &
Frame database. The database was searched for all temporary external fixators placed prior to definitive Ilizarov fixation. Data collected – ex-fix type, whether revision was necessary, reasons for revision. Results:. 97 grade III open fractures in 95 patients. 64 required temporary spanning ex-fix: 23 applied at trauma centre/41 at DGH. 14/64 ex-fixes required revision (prior to definitive Ilizarov): poor plastics access(6)/instability(2)/both(6). All 14 revised had been applied in a DGH, i.e. 14/41 DGH ex-fix needed revision (34%). Ex fixes revised after application at trauma centre vs. DGH = 0/23 vs. 14/41, p<
0.01 ×2. Revision of Hoffman hybrid vs. monolateral ex fix = 4/4 vs. 10/60 p<
0.001 ×2. Non
Introduction: To investigate adequacy of temporary ex-fix in grade III open fractures of the tibia, prior to definitive treatment by Flap &
Frame at 2 UK trauma centres. Methods: From 2000 – 2006 all open fractures of the tibia treated by the Ilizarov Method at our two institutions were entered onto the Flap &
Frame database. The database was searched for all temporary external fixators placed prior to definitive Ilizarov fixation. Data collected - ex-fix type, whether revision necessary, reasons for revision. Results:. - 97 grade III open fractures in 95 patients. - 64 required temporary spanning ex-fix:. - 23 applied at trauma centre / 41 at DGH. - 14/64 ex-fixes required revision (prior to definitive Ilizarov):. - poor plastics access (6) / instability (2) /both (6). - All 14 revised were applied in a DGH, i.e. 14/41 DGH ex-fix needed revision (34%). - Ex fixes revised after application at trauma centre vs. DGH = 0/23 vs. 14/41, p<
0.01 X. 2. - Revision of Hoffman hybrid vs. monolateral ex fix = 4/4 vs. 10/60 p<
0.001 X. 2. - Non
Corrosion in modular taper connections of total joint replacement has become a hot topic in the orthopaedic community and failures of
Periprosthetic fractures involving the femoral meta/diaphysis can be treated in various fashions. The overall incidence of those fractures after primary total knee arthroplasties (TKA) ranges from 0.3 to 2.5%, however, can increase above 30% in revision TKA, especially in older patients with poorer bone quality. Various classifications suggest treatment algorithms. However, they are not followed consequently. Revision arthroplasty becomes always necessary if the implant becomes loose. Next, it should be considered in case of an unhappy TKA prior to the fracture rather than going for an osteosynthesis. Coverage of the associated segmental bone loss in combination with proximal fixation, can be achieved in either cemented or non-cemented techniques, with or without the combination of osteosynthetic fracture stabilization. Severe destruction of the metaphyseal bone, often does not allow adequate implant fixation for the revision implant and often does not allow proper anatomic alignment. In addition the destruction might include loss of integrity of the collaterals. Consequently standard or even revision implants might not be appropriate. Although first reports about partial distal femoral replacement are available since the 1960´s, larger case series or technical reports are rare within the literature and limited to some specialised centers. Most series are reported by oncologic centers, with necessary larger osseous resections of the distal femur. The implantation of any mega prosthesis system requires meticulous planning, especially to calculate the appropriate leg length of the implant and resulting leg length. After implant and maybe cement removal, non-structural bone might be resected. Trial insertion is important due to the variation of overall muscle tension and recreation of the former joint line. So far very few companies offer yet such a complete,
Modern hip implants feature a modular design, whereby the individual components of the implant are assembled during the surgery. Increased reported failure rates associated with the utilization of modular junctions have raised many clinical concerns about the increased release of metal ions/debris leading to adverse local tissue reactions. Implant materials are subject to a myriad of mechanical motion and forces, and varying electrochemical conditions and pH changes from the surrounding environment. To date, no studies have attempted to model the collected data in order to predict the performance of the materials so that precautions can be taken before the problem reaches the critical stage. This study reports the effects of pH variation, displacement variation, and load variation on the mechanical and corrosion behavior of the hip implant
INTRODUCTION. Managing severe periacetabular bone loss during revision total hip arthroplasty (THA) is a challenging task. Multiple treatment options have been described. Delta Revision Trabecular Titanium™ (TT) cup is manufactured by Electron Beam Melting (EBM) technology that allows modulating cellular solid structures with an highly porous structure were conceived to rich the goals of high bone ingrowth and physiological load transfer. The caudal hook and fins ensure additional stability and the
Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction. Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.Aims
Methods
The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.Aims
Methods
The objectives of this study were to investigate the patient characteristics and mortality of Vancouver type B periprosthetic femoral fractures (PFF) subgroups divided into two groups according to femoral component stability and to compare postoperative clinical outcomes according to treatment in Vancouver type B2 and B3 fractures. A total of 126 Vancouver type B fractures were analyzed from 2010 to 2019 in 11 associated centres' database (named TRON). We divided the patients into two Vancouver type B subtypes according to implant stability. Patient demographics and functional scores were assessed in the Vancouver type B subtypes. We estimated the mortality according to various patient characteristics and clinical outcomes between the open reduction internal fixation (ORIF) and revision arthroplasty (revision) groups in patients with unstable subtype.Aims
Methods
The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes.Aims
Methods
Aim. Prosthetic joint infections (PJI) after failed knee arthroplasty, especially in complicated courses with persisting or recurrent infections, may result in a considerable destruction of bone substance, the extensor apparatus and the surrounding soft tissue. In these cases reconstruction of a proper knee function may be impossible and the only solutions are: knee arthrodesis or above-the-knee amputation (AKA). However, both methods are associated with considerable functional deficits and high complication rates. The primary aim of the current study is to analyse the clinical course, outcome and complications in patients with knee arthrodesis and AKA after PJI and to compare these two methods in terms of the analysed parameters. Method. Patients treated with a knee arthrodesis or AKA after PJI in an 11-year time period were included in this study. Demographic data, comorbidities, infecting characteristics and operative procedures were recorded. Patients were seen in regular intervals and underwent physical and radiographic examination. Major complications such as: re-infection, implant-failure, revision surgeries or stump healing disorders were recorded. Functional outcome with use of the Lower-Extremity-Functional-Score was assessed and the patients reported general health status (SF-12-questionnaire) was recorded. Results. In total 87 patients with a knee arthrodesis and 32 patients with an AKA after PJI were included. Knee arthrodesis was performed in 81 patients with a
The purpose of the following study was to present the general strategy for preserving the lower extremity by knee arthrodesis and to analyze the outcome of knee arthrodeses performed by a special