Introduction. Total knee arthroplasty (TKA) is a well-established procedure associated with excellent clinical results. We have previously reported that intraoperative knee kinematics correlate with the clinical outcome in mobile bearing TKA. In addition, the intraoperative knee kinematics pattern does not correlate with the degree of preoperative
Primary total knee arthroplasty (TKA) is a reliable
procedure with reproducible long-term results. Nevertheless, there
are conditions related to the type of patient or local conditions
of the knee that can make it a difficult procedure. The most common
scenarios that make it difficult are discussed in this review. These
include patients with many previous operations and incisions, and
those with severe coronal deformities, genu recurvatum, a stiff
Purpose: The aim of this study was to see if there is any relationship between a positive hamstring shift test, which is a measure of
Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of leg length discrepancy (LLD) was present, requiring shortening femoral osteotomy. 12 patients underwent sequential proximal femoral resection with trochanteric osteotomy, 46 subtrochanteric, 6 midshaft, and 25 distal femoral osteotomies with simultaneous valgus correction were performed. All acetabular prostheses were placed in the true anatomical position. We used uncemented high porosity cups. Patients were followed up for a minimum of 12 months. All osteotomies healed uneventfully except 3 non-unions of the greater trochanter in the proximal femur resection group. No femoral shaft fractures in proximally based osteotomies. No significant LLD compared to the unaffected or reconstructed side. 2 patients suffered 3 and 5 degrees malrotation of the femur in the oblique sub-trochanteric group. 3 patients suffered transient sciatic nerve palsies. Shortening femoral osteotomies in the treatment of DDH are necessary to avoid injury to the sciatic nerve. In our series, we found transverse subtrochanteric osteotomies to be the most technically efficient, versatile and predictable in their clinical outcome, due to the ability to correct rotation and preserve the metaphyseal bone integrity, allowing for better initial stem stability. Distal femoral osteotomies allowed for controllable correction of valgus
Several emerging reports suggest an important involvement of the hindfoot alignment in the outcome of knee osteotomy. At present, studies lack a comprehensive overview. Therefore, we aimed to systematically review all biomechanical and clinical studies investigating the role of the hindfoot alignment in the setting of osteotomies around the knee. A systematic literature search was conducted on multiple databases combining “knee osteotomy” and “hindfoot/ankle alignment” search terms. Articles were screened and included according to the PRISMA guidelines. A quality assessment was conducted using the Quality Appraisal for Cadaveric Studies (QUACS) - and modified methodologic index for non-randomized studies (MINORS) scales. Three cadaveric, fourteen retrospective cohort and two case-control studies were eligible for review. Biomechanical hindfoot characteristics were positively affected (n=4), except in rigid subtalar joint (n=1) or talar tilt (n=1) deformity. Patient symptoms and/or radiographic alignment at the level of the hindfoot did also improve after knee osteotomy (n=13), except in case of a small pre-operative lateral distal tibia- and hip knee ankle (HKA) angulation or in case of a large HKA correction (>14.5°). Additionally, a pre-existent hindfoot deformity (>15.9°) was associated with undercorrection of lower limb alignment following knee osteotomy. The mean QUACS score was 61.3% (range: 46–69%) and mean MINORS score was 9.2 out of 16 (range 6–12) for non-comparative and 16.5 out of 24 (range 15–18) for comparative studies. Osteotomies performed to correct
Introduction. To evaluate the results of correction of
This study was performed at Assiut University, Assiut, Egypt. Anterior distal femoral hemiepiphysiodesis (ADFH) using intra-articular plates for the correction of paediatric fixed
Introduction. The constitutional knee anatomy in the coronal plane includes the distal femoral joint line obliquity (DFJLO) which in most patients is in slight valgus positioning. Despite this native anatomy, the mechanical positioning of the femoral component during primary total knee arthroplasty (TKA) often ignores the native DFJLO opting to place the femur in a set degree of valgus that varies upon the practitioner's practice and experience. Unfortunately, this technique is likely to generate high rate of distal lateral femoral overstuffing. This anatomical mismatch might be a cause of anterior knee pain and therefore partly explain the adverse functional outcomes of mechanically aligned (MA) TKA. Our study aims at assessing the relationship between constitutional knee anatomy and clinical outcomes of MA TKA. We hypothesized that a negative relationship would be found between the constitutional frontal
Introduction. Patients undergoing total knee arthroplasty (TKA) with end-stage osteoarthritis of knee have secondary foot and ankle pathology. Some compensatory changes occur at ankle and subtalar joint secondary to malalignment and deformity at the knee joint. Purpose was to evaluate the changes in hindfoot malalignment and foot deformities in patients with advanced osteoarthritis of knee requiring TKA and effect of correction of
Aim. To investigate the effect of the eight plate position in sagittal plane on tibial slope in temporary epiphysiodesis technique applied to the proximal tibia and whether there is a rebound effect after removing the plate. Method. Forty New Zealand rabbits (6 weeks old) were divided into four groups. In all groups, two 1.3 mm mini plates and cortical screws implantation were placed on both medial and lateral side of the proximal epiphysis of the right tibia. In Group 1 and 3, the plates were placed on anterior of the proximal tibial anatomical axis in the sagittal plane, and placed posteriorly in Group 2 and 4. The left tibia was examined as control in all groups. Group 1 and Group 2 were sacrificed after four week-follow-up. In Group 3 and Group 4, the implants were removed four weeks after index surgery and the rabbits were followed four more weeks to investigate the rebound effect. The tibial slope was measured on lateral X-rays every two weeks. Both medial and lateral plateau slopes were evaluated on photos of the dissected tibia. Results. In Group 1, right MTPA (medial tibial plateau angle) and left MTPA, right LTPA (lateral tibial plateau angle) and left LTPA, and right 4wTPPA (the tibial proximal posterior angle at 4th week) and left 4wTPPA values were compared with each other. There was a significant difference in MTPA, LTPA, and 4wTPPA in Group 1 (p: 0.003, 0.006, 0.004). In Group 1, the medial and lateral slope significantly decreased after 4 weeks. There was no significant difference in MTPA, LTP and 4wTPPA measurements in Group 2 (p= 0.719, 0.306, 0.446, respectively). In Group 2, the slope did not change in four weeks. There was a significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA (tibial proximal posterior angle at 8th week) in Group 3 (p= 0.005, 0.002, <0.001, <0.001, respectively). In Group 3, the slope decreased at 4th week and remained stabile during the next four week-follow up and no rebound effect was observed. There was no significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA measurements in Group 4 (p= 0.791, 0.116, 0.232, 0.924), respectively. In group 4, slope did not change at 4th week of index surgery and no rebound effect was observed in the next four week-follow up. Conclusion. If eight plates were placed on anterior of lateral proximal tibia axis on both medial and lateral side, the tibial slope would reduce, and remain stabile after implant removal. Care should be taken to place the plates on the line of proximal tibial axis in sagittal plane in temporary epiphysiodesis technique performed due to angular
With the success of the medial parapatellar approach (MPA) to total knee arthroplasty (TKA), current research is aimed at reducing iatrogenic microneurovascular and soft tissues damage to the knee. In an effort to avoid disruption to the medial structures of the knee, we propose a novel quadriceps-sparing, subvastus lateralis approach (SLA) to TKA. The aim of the present study is to compare if a SLA can provide adequate exposure of the internal compartment of the knee while reducing soft tissue damage, compared to the MPA. Less disruption of these tissues could translate to better patient outcomes, such as reduced post-operative pain, increased range of motion, reduced instances of patellar maltracking or necrosis, and a shorter recovery time. To determine if adequate exposure could be achieved, the length of the skin incision and perimeter of surgical exposure was compared amongst 22 paired fresh-frozen cadaveric lower limbs (five females/six males) which underwent TKA using the SLA or MPA approach. Additionally, subjective observations which included the percent of visibility of the femoral condyles and tibial plateau, as well as the patellar tracking, were noted in order to qualify adequate exposure. All procedures were conducted by the same surgeon. Subsequently, to determine the extent of soft tissue damage associated with the approaches, an observational assessment of the dynamic and static structures of the knee was performed, in addition to an examination of the microneurovascular structures involved. Dynamic and static structures were assessed by measuring the extent of muscular and ligamentus damage during gross dissection of the internal compartment of the knee. Microneurovascular involvement was evaluated through a microscopic histological examination of the tissue harvested adjacent to the capsular incision. Comparison of the mean exposure perimeter and length of incision was not significantly different between the SLA and the MPA (p>0.05). In fact, on average, the SLA facilitated a 5 mm larger exposure perimeter to the internal compartment, with an 8 mm smaller incision, compared to the MPA, additional investigation is required to assert the clinical implications of these findings. Preliminary analysis of the total visibility of the femoral condyles were comparable between the SLA and MPA, though the tibial plateau visibility appears slightly reduced in the SLA. Analyses of differences in soft tissue damage are in progress. Adequate exposure to the internal compartment of the knee can be achieved using an incision of similar length when the SLA to TKA is performed, compared to the standard MPA. Future studies should evaluate the versatility of the SLA through an examination of specimens with a known degree of
Background. We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result. Methods. From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus
An osteochondral defect greater than 3cm in diameter and 1cm in depth is best managed by an osteochondral allograft. If there is an associated
Introduction. Valgus deformity in an end stage osteoarthritic knee can be difficult to correct with no clear consensus on case management. Dependent on if the joint can be reduced and the degree of medial laxity or distension, a surgeon must use their discretion on the correct method for adequate lateral releases. Robotic assisted (RA) technology has been shown to have three dimensional (3D) cut accuracy which could assist with addressing these complex cases. The purpose of this work was to determine the number of soft tissue releases and component orientation of valgus cases performed with RA total knee arthroplasty (TKA). Methods. This study was a retrospective chart review of 72 RATKA cases with valgus deformity pre-operatively performed by a single surgeon from July 2016 to December 2017. Initial and final 3D component alignment, knee balancing gaps, component size, and full or partial releases were collected intraoperatively. Post-operatively, radiographs, adverse events, WOMAC total and KOOS Jr scores were collected at 6 months, 1 year and 2 year post-operatively. Results. Pre-operatively,
While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA. A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations.Aims
Methods
Background. Total knee arthroplasty (TKA) is an effective surgical procedure to alleviate excruciating pain and correct dysfunction due to severe
Objectives. Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments. Materials and Methods. Bone models were constructed from one volunteer (normal) and three patients with three different
An osteochondral defect greater than 3cm in diameter and 1cm in depth is best managed by an osteochondral allograft. If there is an associated
A prospective study of 276 TKA's performed in patients with valgus
Introduction: Majority of children with cerebral palsy patients suffer from fixed flexion contractures of their knees. Procedures commonly used to correct