Purpose of the study: Cementless hydroxyapatite-coated prostheses have proven their reliability, but how about their longevity? The intimate contact between the receiver bone and the prosthetic implant, due to the bone ongrowth, allows ‘union’ between the inert and living material. The purpose of this restrospective study was to evaluate the behavior of an anatomic femoral
The ABG stem (Anatomique Benoist Girard, How-medica) was realized of titanium alloy (TA6V) and it was designed to provide anchoring only at the femour’s metaphyseal portion. The long-term stability is achived by osteointegration of the implant at the metaphyseal region, which is coated with hydroxyapatite (HA) crystals. The plasma-sprayed HA coating has a tickness of 60 μm for the stem. The current study presents radiographic outcomes of more than one hundred primary uncemented HA stems with a long-term follow-up. One hundred and eleven ABG hip arthroplasties were evaluated with a mean follow-up of 9.8 years. The radiographical findings have been classified observing Engh’s stability criteria according to Gruen’s subdivision of the periprosthetic femoral zones. Dividing the hips into two different groups (in the first one the prosthesis implanted 11, 12 or 13 years ago and in the second one the prosthesis with a maximum age of 10 years) it’s possible to see as in the first group the radiolucent lines are quite reduced. Among the older prosthesis the percentage of radiolucent lines is 3.1% in zones 3 and 5 and 18.8% in zone 4. For what concerns the younger ones the percentage are 10.1% (zone 3), 21.5% (zone 4) and 15.2% (zone 5). We believe that there is a load transfer from the metaphyseal to the metadiaphyseal portion of the femur without a worsening of the clinical outcomes. The absence of reactive lines and lucencies around the proximal HA-coated portion of the stem supports an excellent circumferential bony ingrowth in the metaphyseal area of the proximal femur. According to these percentages we can say that there’s less presence of radiolucency in the oldest prosthesis and it could be possible to argue that radiolucent lines tend to reduce along the time. This is probably due to the increase of the strength of the stem anchorage.
Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design geometry using the system proposed by Radaelli et al. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper
Introduction and Aims: This study evaluated the proximal femoral remodelling associated with three uncemented femoral prostheses of different designs and surface treatments. We hypothesised that less bone loss will occur over time with a titanium implant designed for proximal stress transfer compared to a more rigid stem that produces diaphyseal loading. Method: During total hip arthroplasty (THA), patients were implanted with either: AML cobalt-chrome alloy porous-coated stem (11 patients), Osteonics titanium alloy
Introduction: The results of total hip arthroplasty in patients with avascular necrosis of the hip have been variable. This study analyzed the clinical and radiographic outcome of young patients (mean age of 39 years) treated with a proximally
We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis. 82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally
Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated with a mean follow-up of 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally
Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) system after twenty years analysing polyethylene wear and the appearance of osteolysis. Materials and Methods. 82 hips implanted between 1992 and 1995 were prospectively evaluated. The mean follow-up was 20.6 years (range, 18 to 23). A hemispherical porous-coated acetabular cup matched to a proximally
Background: According to the mid-term results obtained from the previous registry-based studies, survival of cementless stems for aseptic loosening in younger patients with primary osteoarthritis has been better than the survival of cemented stems. However, it has not been clear if the endurance against aseptic loosening of cementless cups is comparable to that of cemented cups. The aim of the present study was to analyze population-based long-term survival rates of the cemented and cementless total hip replacements in patients under the age of fifty-five years with primary osteoarthritis in Finland. Patients and Methods: Between 1980 and 2006, a total of 7310 primary total hip replacements performed for primary osteoarthritis in patients under the age of fifty-five years were entered in the Finnish Arthroplasty Registry. 4,032 of them fulfilled our inclusion criteria and were subjected to analysis. The implants included were classified in one of the three following groups: implants with a cementless, straight, proximally circumferentially porous-coated stem and a porous-coated press-fit cup (cementless group #1); implants with a cementless, anatomic, proximally circumferentially porous-coated and/ or
Aims: The purpose of this study is to compare the clinical outcome, radiological integration and survivorship associated with a porous coated stem and those associated with a
Introduction: In the last years, the use of second generation cementless anatomical stems has generated an increasing interest in primary total hip arthroplasty. They are believed to offer long term stability through appropriate stress transfer and bone remodelling in the proximal femur. We conducted a monocentric prospective study on a homogeneous series of total hip replacements performed with a cementless anatomic,
Purpose: The purpose of this work was to assess the quality of the bone reconstruction in contact with the long hydroxyapatite-coated locked femoral stem used in a consecutive series of patients undergoing revision total hip arthroplasty (RTHA). Material and methods: This series of 20 patients underwent RTHA for aseptic loosening (n=15) or septic loosening (n=5) of an AURA prosthesis. Mean age was 70.5 years. Mean time between insertion of the first stem and revision was 11 years for the aseptic patients and 2.6 years for the septic patients. Bony lesions of the femur were assessed with the SOFCOT classification: grade I=5, grade II=4, grade III=4, and grade IV=1. A transfemoral approach with a floating femoral segment was used in 14 patients and an endofemoral approach in six. The septic loosenings were reconstructed in two operative times in four patients and in one operation in one patient. An AURA reconstruction stem was used in 15 cases and a revision stem in five. A complementary cancellous bone graft with the endofemoral approach was used in six patients. Results: Two patients died. All others were reviewed at a mean follow-up of 26 months (range 12–46 months) for clinical and radiographic assessment (five patients also had a supplementary scan at more than three years follow-up). We had three dislocations at 15 days with no recurrence and one case of sepsis at three months which cured after wash out and adapted antibiotics. All the femoral segments healed starting on the tenth week. The PMA score improved from 9.1 to 15.66 and the Harris score from 43.5 to 85.5. At last follow-up, all femoral lesions had moved to a lower SOFCOT score. There was a tight contact between the AURA stem and the femur on the last follow-up scan which showed an increase in the cortical index from 1 to 8 cm from the metaphyseal spine of the stem. None of the patients experienced secondary unlocking or required revision for a shorter stem. Discussion: Revision after femoral failure with bone destruction using a non-cemented
Introduction & aims. The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration. Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail
Introduction First metatarsophalangeal (MTP) arthroplasty is a relatively uncommon procedure compared with hip and knee joint replacement. A range of different designs of first MTP prostheses have been proposed including metal hemi-arthroplasties, single-piece double-stem silicone designs, and multi-component designs. Of the latter group, a cobalt chrome-on-cobalt chrome prosthesis, which had a diamond like carbon (DLC) coating applied to its articulating faces and