Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app). A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability.Aims
Methods
Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes. A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.Aims
Methods
Migration analysis after total joint arthroplasty are performed using EBRA analysis (Krismer et al., 1997) or - more accurate but also much more cost-intensive and time-consuming – via radiostereometric analysis (RSA). For the latter, additional radiographs from two inclined perspectives are needed in regular intervals in order to define the position of the implant relative to tantalum bone markers which have been implanted during surgery of the artificial joint (Fig. 1). Modern analysis software promises a migration precision along the stem axis of a hip implant of less than 100 μm (Witvoet-Brahm et al., 2007). However, as the analysis is performed semi-automatically, the results are still dependent on the subjective evaluation of the X-rays by the observer. Thus, the present phantom study aims at evaluating the inter- and intra-observer reliability, the repeatability as well as the precision and gives insight into the potential and limits of the RSA method. Considering published models, an RSA phantom model has been developed which allows a continuous and exact positioning of the prostheses in all six degrees of freedom (Fig. 2). The position sensitivities of the translative and rotative positioning components are 1 μm and 5 to 24, respectively. The roentgen setup and Model-Based RSA software (3.3, Medis specials bv, Leiden, Netherlands) was evaluated using the SL-PLUS® standard hip stem (size 7, Smith & Nephew, Baar, Switzerland). The inter-observer (10 repetitions) and intra-observer (3 observers) reliability have been considered. Additionally, the influences of the model repositioning and inclination as well as the precision after migration and rotation along the stem axis are investigated.Background
Materials and Methods
Accurate detection of migration of hip arthroplasty stems without the burden of bone markers and stereo-radiographic equipment is of interest. This would facilitate the study of stem migration in an experimental setting, but more importantly, it would allow assessing stem loosening in patients with a painful hip outside a study protocol. We developed and validated a marker-free automated CT-based spatial analysis method (CTSA) to quantify stem-bone migration in successive CT scan acquisitions. First, we segmented the bone and stem within both three-dimensional images, then we pairwise registered those elements (Fig. 1). By comparing the rigid transformations of stem and bone, we calculated the migration of the stem with reference to the bone and transferred the three translation and three rotation parameters to an anatomic coordinate system. Based on the rigid transformation, we also calculated the point of the stem that presented the maximal migration (PMM). Accuracy was assessed in a stem-bone model (Fig. 2) by imposing 39 predefined stem rotations and translations, and by comparing those with values calculated with the CTSA tool. In all cases, differences were below 0.20 mm for translations and 0.19° for rotations (95% tolerance interval (95% TI) below 0.22 mm and 0.20°, largest standard deviation of the signed error (SDSE) 0.081 mm and 0.057°). Precision was defined as stem migration calculated in eight clinical relevant zero-migration scenarios. In all cases, precision was below 0.05 mm and 0.08° (95% TI below 0.06 mm and 0.08°, largest SDSE 0.012 mm and 0.020°). The largest displacement of the PMM on the stem was 0.169mm. The precision estimated in five patients was very dependent on the CT scan resolution and was below 0.48 mm and 0.37° (95% TI below 0.59 mm and 0.61°, largest SDSE 0.202 mm and 0.279°, largest displacement of the PMM 0.972 mm). In optimized conditions, the precision in patients improved largely and was below 0.040 mm and 0.111° (largest SDSE 0.202 mm and 0.279°, largest displacement of the PMM 0.156 mm). Our marker-free automated CT-based spatial analysis can detect
Purpose. This study re-examined the influence of the head shaft angle (HSA) on hip dislocation in a large cohort of children with cerebral palsy (CP). Method. The radiographs of GMFCS Level III – V children from a surveillance programme database were analysed and migration percentage (MP) and HSA measured. The first radiograph of each patient was taken to remove the effect of the surveillance programme. The most displaced hip in each child, by MP, was used for analysis and the corresponding HSA measured. Hip displacement was defined as MP >
40%
and logistic regression was used to adjust for HSA, GMFCS, age and sex. Results. 640 children were eligible (271 female (42.3%
), 369 male (57.7%
), mean age 8.2 years, GMFCS III: 160 (25%
), GMFCS IV: 184 (28.75%
), GMFCS V: 296 (46.25%
). 118 children (18.44%
) had a MP >
40%
and mean HSA was 160° (range 111 – 180°). Statistical analysis showed that an increasing HSA was associated with hip displacement (odds ratio of 1.02 for a 1° change). A 10° difference in HSA between two patients of the same age, sex and GMFCS gave odds of 1.26 of the patient with the higher HSA having hip displacement. Age and sex had no influence in this model, while a high GMFCS-level was a strong risk factor. Conclusion. Chougule et al found no correlation between HSA and
Purpose. The purpose of this paper is to describe the outcomes of major hip surgery for children with cerebral palsy and communication difficulties using a validated health related quality of life measure and a validated pain score. Method. Children with hypertonic bilateral cerebral palsy (CP) GMFCS levels IV and V, 2–15 years old, having femoral +
/- acetabular osteotomies for hip displacement were included if their ability to communicate necessitated the use of the CPCHILD (Caregiver Priorities and Child Health Index of Life with Disabilities) and PPP (Paediatric Pain Profile). The underlying indication for surgery was a
Though over ten-year follow-up results of impaction bone grafting for acetabular reconstruction from European countries are available in literatures, clinical reports from Asian countries are rare. The purpose of the present study is to assess mid-term clinical and radiographic follow-up results at least three years after acetabular reconstruction with impaction bone grafting technique by single surgeon in Japanese cohort. The senior author performed 24 acetabular revisions with impaction bone grafting technique in 24 patients from February 2001 to June 2005. The average age of the patients at the revision was 67.5 years (36–82 years). The average follow-up period was 5 years and 5 months (3–7.3 years). The reasons for the operation were aseptic loosening of sockets in 17
Background. Dislocation is a common complication after proximal and total femur prosthesis reconstruction for primary bone sarcoma patients. Expandable prosthesis in children puts an additional challenge due to the lengthening process. Hip stability is impaired due to multiple factors: Resection of the hip stabilizers as part of the sarcoma resection: forces acts on the hip during the lengthening; and mismatch of native growing acetabulum to the metal femoral head. Surgical solutions described in literature are various with reported low rates of success. Objective. Assess a novel 3D surgical planning technology by use of 3D models (computerized and physical), 3D planning, and Patient Specific Instruments (PSI) in supporting correction of young children suffering from hip instability after expandable prosthesis reconstruction following proximal femur resection. This innovative technology creates a new dimension of visualization and customization, and could improve understanding of this complex problem and facilitate the surgical decision making and procedure. Method. Two children, both patients with Ewing Sarcoma of the left proximal femur stage-IIB, ages 3/5 years at diagnosis, were treated with conventional chemotherapy followed by proximal femur resection. Both were reconstructed with expandable prosthesis (one at resection and other 4 years after resection).
Introduction. Acetabular reconstruction of a total hip arthroplasty (THA) for a case with severe bone loss is most challenging for surgeon. Relatively high rate of failure after the reconstruction surgery have been reported. We have used Kerboull-type acetabular reinforcement devices with morsellised or bulk bone allografts for these cases. The purpose of this study was to examine the midterm results of revision THA using Kerboull-type acetabular reinforcement devices. Patients and methods. We retrospectively reviewed 20 hips of revision THA (20 patients) between February 2002 and August 2010. The mean age of the patients at the time of surgery was 67.4 years (range 45–78). All of the cases were female. The mean duration of follow-up was 6.5 years (range 2.1–10.4). The reasons of revision surgeries were aseptic loosening in 10
This study evaluates outcomes of hip adductor surgery in children with cerebral palsy in preventing hip displacement. This review is from the perspective of an extended follow-up (beyond 3 years in contrast to currently available literature) and the Gross Motor Function Classification System (GMFCS). A retrospective audit was performed of children with cerebral palsy aged 2 to 10 years who had primary adductor surgery at the Royal Children’s Hospital Melbourne between January 1994 and December 2004. These children had
Scoliosis and hip subluxation/dislocation are common and often coexistent problems encountered in patients with cerebral palsy (CP). The underlying mechanism may be related to muscle imbalance. Surgical correction may become necessary in severe symptomatic cases. The effect of surgical correction of one deformity on the other is not well understood. We retrospectively reviewed a series of 17 patients with total body cerebral palsy with diagnoses of both scoliosis and hip subluxation who had undergone either surgical correction of their scoliosis (9 patients) or a hip reconstruction to correct hip deformity (8 patients). In all patients, the degree of progression of both deformities was measured, radiographically, using the Cobb angle for the spine and the percentage migration index for hip centre of rotation at intervals before and at least 18 months post surgery. All patients who underwent scoliosis correction had a progressive increase in the percentage of
Introduction: The aims of this study are:. To report and validate the early migration rates of the collarless polished tapered hip replacement using manual and computer measurements. To report early clinical results of the CPT hip. Patients and methods: 80 patients undergoing primary total hip replacement in a single centre were prospectively recruited into the trial. There were 59 females and 21 males: age range 31–84 years, (mean 68 years sd 9.86). Surgery was performed through an anterolateral approach in all cases. A standard cementing technique using a cement gun and cement restrictor was employed. The patients had standardised anteroposterior standing hip radiographs taken post operatively, then yearly. The migration was measured along the long axis of the femoral component In the anteroposterior plane, using the tip of the greater trochanter as a bony landmark. Measurements were made by two independent observers (specialist registrars). Plain radiographs were measured manually using a ruler and set square and digitised images using a software package designed in-house at Dundee University. Correction for magnification was incorporated. Hip assessments were performed at each review by an independent reviewer. Results: The mean migration rates and 95% confidence intervals (Cl) and mean Harris pain and Harris hip scores and Std Deviations were:. There was no significant difference between inter or intra observer measurements for
Purpose: We report the clinical and radiological outcome of revision of cemented hip arthroplasties using Hydroxyapatite ceramic (HAC) coated femoral and acetabular components. Patients and Methods: 66-revision hip arthroplasties were performed in 64 patients with JRI Furlong HAC coated femoral and acetabular components. The patients were followed for a mean 10.6 years (7–15). The femoral component was revised in all hips and the acetabular cup was revised in 52 hips (79%). The clinical outcome was measured using Harris, Charnley and Oxford hip scores. Anterior thigh pain was quantified on a visual analogue scale (VAS). The quality of life was assessed using EuroQol EQ-5D. All pre op, immediate post op and last follow up radiographs were analysed for ace-tabular and femoral component loosening. Results:The mean age was 78.2yrs (58–89yrs). The mean time to revision of the primary hip replacement was 96 months (24 to 161). 11 patients died due to causes unrelated to the index revision. At last follow up, the mean Harris and Oxford hip scores were 82 (59 – 100) and 24.4 (12-52) respectively. The Charnley score was 5.0 (3-6) for pain, 4.9 (3-6) for movement and 4.4 (3-6) for mobility. Acetabular bone grafting was performed in 26 (50%)
Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement.Aims
Methods
Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips. In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).Aims
Methods
Purpose. A Trabecular Metal Modular Acetabular System (Zimmer, Warsaw, Indiana, USA) is a peripheral rim expansion (elliptical) cup, i.e. a non-hemispherical cup. Radiologically a non-hemispherical cup may be deferent from other conventional hemispherical cups. We reviewed radiological findings of a Trabecular Metal Modular Acetabular System chronologically. Methods. Twenty six patients with osteoarthritis underwent primary total hip arthroplasty (THA) using a Trabecular Metal Modular Acetabular System from 2011 to April 2013. Twenty five patients (follow-up rate: 96.2%) 31 hips could be followed-up over a year were registered. In common, the diameter of every femoral head was 32 mm. We planned the acetabular cup inclination angle to be 45-degree, the cup coverage with host-bone (cup-CE angle) to be over 10-degree, and high hip center was allowed up to 20mm. In case of the cup-CE angle under 10-degree, an acetabular cup was placed medially using Dorr's medial protrusio technique. We established the medial protrusion angle indicating the degree of medial protrusion of an acetabular cup over the pelvic internal wall. The medial protrusion angle was defined by the center point of THA (C) and the 2 cross-points (X. 1. , X. 2. ) which the outline of an acetabular cup crosses the Kohler's line (Figure 1). The cup anteversion angle was measured by the method of Lewinnek, and the cup fixation was evaluated according to the Tompkin's classification. Results. The average follow-up period was 1 year and 3 months (1y1m to 2y8m). The mean diameter of the cup was 54 (48 to 56) mm. Seven high-hip center joints were recognized (2 to 11 mm). The average of cup inclination angle was 42 (32 to 52) degree, of cup anteversion angle was 14 (5 to 36) degree, and of cup CE angle was 25 (−14 to 45) degree. Dorr's medial protrusio technique was necessary in 18 hips. In these 18 hips, the average of medial protrusion angle was 57 (24 to 70) degree. In 4 hips of cup-CE angle less than 10 degree, acetabular bulky bone graft was added. All 31 hips showed the stable fixation, even in 18 hips undergone medial protrusio technique. There was none of
Introduction: The C-stem (DePuy, Leeds, UK) is triple tapered, polished and collarless. These features can facilitate distal stem migration within the cement mantle, a phenomenon first noticed on radiographs and later confirmed by radiostrereometric analysis (RSA) for the double tapered polished Exeter stem (Stryker, Mahwah, NJ). Low revision rates are reported for the Exeter stem and the view that early migration predicts later failure has not been confirmed with double tapered designs. If a triple tapered stem has any advantages is however not known. Patients and methods: 33 primary hip arthroplasties with a median age of 66 (46–74) years were followed for 2 years with radiostereometric analysis (RSA) at 3 months, 6 months, 1, 2 and 3 years. The diagnosis was primary osteoarthrosis in all
Hip resurfacing preserves proximal femoral bone stock, optimises stress transfer to the proximal femur and offers inherent stability and optimal range of movement. The early results of metal–on-polyethylene resurfacing designs were poor and the resurfacing concept was largely abandoned. Modern metal-on-metal articulations enabled the introduction of a new generation of hip resurfacings with encouraging early results. In 1997 two of the authors developed a hip resurfacing system utilizing a metal-on-metal bearing. Our study reports on the clinical and radiological outcomes of the first 200 hips that were treated with the Durom hip resurfacing at an average follow up of 4.6 years (range 3.5–6). Between May 2001 and December 2003, 200 consecutive hip resurfacings were performed on 189 patients, using the Durom hybrid metal-on-metal system. The average age of the patients was 50 years (range 22.5 – 72.3) and 119 were male. Patients were seen at 6 weeks and at 3, 6 and 12 months and annually thereafter for clinical and radiological evaluation. Clinical results were evaluated using the Harris Hip Score. A subjective assessment of patient satisfaction was obtained and patient activity was assessed using the UCLA activity score. No patient was lost to follow up. There were no dislocations and no femoral neck fractures. One femoral component was revised due to aseptic loosening 3.9 years postoperatively. There was one late acute haematogenous infection that was successfully treated elsewhere by debridement and retention of the prosthesis. The mean Harris Hip Score improved significantly from 46.7 preoperatively to 94.4 postoperatively. The mean HHS constituents for pain, function and motion all were significantly improved from the preoperative values of 11.9, 25.7 and 4.2 to 41.8, 43.4 and 4.8 respectively following the resurfacing procedure. The mean UCLA activity score was 7.2 indicating a relatively active patient population and 179 hips were rated as excellent by the patients. No cup was considered radiographically loose. Extensive radiologic changes were observed around the femoral stem in 2.5% of the