Advertisement for orthosearch.org.uk
Results 1 - 20 of 103
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 9 - 9
1 Jul 2016
Jawalkar H Aggarwal S Bilal A Oluwasegun A Tavakkolizadeh A Compson J
Full Access

Scaphoid fractures accounts for approximately 15% of all fractures of hand and wrist. Proximal pole fractures represent 10–20% of scaphoid fractures. Non –operative treatment shows high incidence of non-union and avascular necrosis. Surgical intervention with bone graft is associated with better outcome. The aim of this study was to evaluate the radiological and functional outcome of management of proximal pole scaphoid non-union with internal fixation and bone grafting. We included 35 patients with proximal pole scaphoid non-union (2008–2015). All patients underwent antegrade headless compression screw fixation and bone grafting at King's College Hospital, London (except one, who was fixed with Kirschner wire). 33 patients had bone graft from distal radius and two from iliac crest. Postoperatively patients were treated in plaster for 6–8 weeks, followed by splinting for 4–6 weeks and hand physiotherapy. All the patients were analysed at the final follow-up using DASH score and x-rays. Mean age of the patients was 28 years (20–61) in 32 men and 3 women. We lost three patients (9%) to follow up. At a mean follow up of 16 weeks (12–18) twenty three patients (66%) achieved radiological union. All patients but three (91%) achieved good functional outcome at mean follow up of 14 weeks (10–16). A good functional outcome can be achieved with surgical fixation and bone graft in proximal pole scaphoid fractures non-union. Pre-operative fragmentation of proximal pole dictates type of fixation (screw or k wire or no fixation). There was no difference in outcome whether graft was harvested from distal radius or iliac crest


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims. Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). Methods. In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years. Results. Mean follow-up was 4.6 years (4.1 to 5.0) in the CCS group and 5.5 years (5.25 to 5.75) in the VOOF group. The mean Harris Hip Score at two-year follow-up was 83.85 in the CCS group versus 88.00 in the VOOF group (p < 0.001). At the latest follow-up, all-cause failure rate was 29.1% in the CCS group and 11.7% in the VOOF group (p = 0.003). The total cost of the VOOF technique was 7.2% of a THA, and total cost of the CCS technique was 6.3% of a THA. Conclusion. The VOOF technique decreased all-cause failure rate compared to CCS. The total cost of VOOF was 13.5% greater than CCS, but 92.8% less than a THA. Increased cost of VOOF was considered acceptable to all patients in this series. VOOF technique provides a reasonable alternative to THA in patients who cannot afford a THA procedure. Cite this article: Bone Jt Open 2023;4(5):329–337


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 146 - 146
1 May 2011
Klos K Windolf M Boyko G Schwieger K Hofmann G Mückley T
Full Access

Background: Lapidus (first metatarsocuneiform joint) arthrodesis is an established procedure for the management of hallux valgus. This study investigated the utility of fixation with a medial locking plate with adjunct compression screw versus fixation with two crossed screws. Methods: Eight pairs of fresh-frozen human specimens were used in a matched paired test. Bone mineral density (BMD) was measured with peripheral quantitative computed tomography (pQCT). Fixation with two 4-mm-diameter crossed screws was compared versus a medial locking plate (X-Locking Plate 2.4/2.7; Synthes, Solothurn, Switzerland) with adjunct 4-mm-diameter compression screw. The specimens tested in a four-point bending test. Parameters obtained were initial stiffness; plantar joint-line gapping after one cycle, 100 and 1000 cycles; and number of cycles to failure. Failure was defined as ≥ 3 mm plantar gapping displacement. Results: The groups did not differ significantly with regard to BMD (p = 0.866) and initial stiffness (p = 0.889). The plate-and-screw construct showed significantly less movement during testing, and significantly (p = 0.001) more cycles to failure than did the crossed-screw construct. There was a significant correlation (crossed-screw construct: p = 0.014; plate-and-screw construct: p = 0.010) between BMD and the number of cycles to failure. Conclusions: Under cyclic loading conditions, the construct using a medial locking plate with adjunct compression screw was superior to the construct using two crossed screws. Clinical Relevance: The medial locking-plate technique described holds promise for shortening the time off weight-bearing and for reducing the risk of non-union


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 27 - 27
1 May 2012
Oddy M Konan S Meswania J Blunn G Madhav R
Full Access

Medial Displacement Osteotomy (MDO) of the os calcis is used to correct the hind foot valgus in a flat foot deformity. Screw fixation is commonly used although contemporary locking plate systems are now available. This study tested the hypothesis that a 10mm MDO would support a higher load to failure with a locked step plate than with a single cannulated screw. Materials and Methods. Eight pairs of embalmed cadaveric limbs harvested 10cm below the knee joint were axially loaded using a mechanical testing rig. Two pairs served as non-operated controls loaded to 4500N. The remaining limbs in pairs underwent a 10mm MDO of the os calcis and were stabilised with a locked step plate or a 7mm cannulated compression screw. One pair was loaded to 1600N (twice body weight) as a pilot study and the remaining 5 pairs were loaded to failure up to 4500N. The force-displacement curve and maximum force were correlated with observations of the mechanism of failure. Results. In one pair of control limbs, failure occurred with fractures through both os calcis bones, whilst the other pair did not undergo mechanical failure to 4500N. In the pilot osteotomy, the plate did not fail whilst loss of fixation with the screw was observed below 1600N. For the remaining five pairs, the median (with 95% Confidence Intervals) of the maximum force under load to failure were 1778.81N (1099.39 – 2311.66) and 826.13N (287.52 – 1606.67) for the plate and screw respectively (Wilcoxon Signed Rank test p=0.043). In those with screw fixation loaded to 4500N, the tuberosity fragment consistently failed by rotation and angulation into varus. Conclusion. In this model of load to failure with a medial displacement os calcis osteotomy, a locked step plate supported a significantly higher maximum force than a single large cannulated screw


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 262 - 262
1 Sep 2005
Lenehan B Murphy B McHugh P Curtin W
Full Access

Over the past four decades, internal fixation has continued to gain popularity as a method for treating fractures because of significant improvements in both implant design and materials. This biomechanical study compares the compressive forces generated by a conventional 4.5 AO/ASIF cortical screw lag screw with a differential pitch cortical compression screw in a simulated fracture model using whole bone composite femur. The differential pitch screw investigated in this study generates 82% of the compression generated by a conventional 4.5mm AO/ASIF cortical screw. Proving compression in diaphyseal fractures is achievable using a differential pitch screw. Sufficient compression is generated to allow osteosynthesis using a plate to be preformed independent of the lag screw positioning. It is thus advantageous over the traditional compromise that arises when exposure to the fracture site is limited, of either incorporating the lag screw into the plate of choosing a non-optimal plate or screw position. It is proposed as an adjunct to the internal fixation of long bone fractures and not a single fixation device


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 390 - 390
1 Sep 2005
Peleg E Mattan Y Liebergall M Mosheiff R
Full Access

Introduction: Decreasing the length of the side plate of the dynamic hip screw (DHS) would theoretically allow a smaller surgical incision, a shorter surgical time, decreased operative blood loss and minimal periosteal stripping. A new design of a very short plate (VSP) dynamic hip screw based on two diagonal screws has been developed. The new design was compared with the four hole side plate regarding its mechanical properties and bio-mechanical outcomes.

Methods: Four pairs of fresh frozen cadaveric femora were extracted from male corpses aged 25–43 (mean 34.8), mechanical loading was applied to four pairs of cadaveric femora which were fixated using the new system on one side and the conventional design on the other. The decline during the periodical loading and the breakage load of the fixated bones were measured. In addition, mechanical performance and probability for failure was assessed by conducting a mathematical analysis using the finite element method.

Results: The average deflection under excessive cyclic loading was 33% higher in bones with the VSP-DHS device than those with regular DHS. The average load failure during the collapse loading test was 312 kg for the VSP-DHS compared to 416 kg for the regular device. The mathematical analysis performed indicated that the maximal stress in the VSP-DHS reached values 3–4 fold higher than in the regular DHS.

Conclusions: Bio-mechanical evaluation was performed both by mechanical testing and theoretically. Although the new design offers a minimally invasive approach to subtrochanteric femur fracture fixation, it was found to have insufficient biomechanical performance resulting in high probability for mechanical failure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 117 - 117
1 Sep 2012
Gupta A Cooke C Wilkinson M Grazette A
Full Access

Prospective Randomised Control trial of 300 patients over a period of 3 years, 1 year post op follow up. Local ethic approval was attained for the study. Inclusion criteria: Age > 60, Consented to Participate in the study, Unstable Inter trochanteric fracture a) Sub trochanteric b) Medial Comminution c) Reverse Obliquity D)Severe Osteoporosis. Patients selected were randomized to Intra medullary Nail vs Hips screw. Variety of markers have been assessed: Pre OP: - Mechanism of injury, Mobility status, Pre OP ASA, Pre Op haemoglobin, living Conditions. Intra OP:- I.I Time, Time taken, Surgeon experience, Intra OP complications. Post OP:- Haemoglobin, mobility, radiographic analysis-Fracture stability and Tip Apex Distance, Thrombo embolic Complications. Follow up: - 6 weeks, 3,6,12 month follow up. There is considerable debate in literature regarding superiority of Compression Hip screw over Intra medullary nail for fixation of stable per trochanteric fractures of the femur. Biomechanical studies have shown superiority of Intra medullary device over a Compression Hip screw. Tenser et all showed an advantage over combined bending and compression failure. Mohammad et al found unstable subtrochanteric fractures with a gamma nail were stiffer. Kerush-Brinker showed that gamma nail had significantly greater fatigue strength and fatigue life. In unstable fractures Baumgartner et al found less intra op complications and less fluoroscopic time for a compression hip screw compared to a short intra medullary nail. There have been significant reports of fracture at the Tip of a short intra medullary nail. We think this complication can be avoided by using a long intra medullary device. Both in Australia and abroad the choice of which device to use depends largely on the preference of the surgeon


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 313 - 314
1 Jul 2011
Ahmad M Bajwa A Patil S Bhattacharya R Nanda R Danjoux G Hui A
Full Access

Introduction: To quantify the magnitude and incidence of haemodynamic changes that occurs during the fixation of extracapsular proximal femoral fractures when using either intra-medullary or extra-medullary fixation device. Methods: A prospective group of 31 patients with extra-capsular proximal femoral fractures were randomised to either fixation using an extra-medullary compression hip screw or an intra-medullary hip screw. All patients received a general anaesthetic adhering to a standardised anaesthetic protocol including invasive blood pressure monitoring and arterial blood gas sampling. Trans-oesophageal Doppler probe and monitor was used to record pre-operative hypovolaemia and peri-operative changes in cardiac output, stroke volume and corrected flow time (FTc – a reflection of left ventricular end diastolic pressure) during placement of implants. Results: 77% of patients were hypovolaemic preoperatively, which was corrected with an average of 439 mls of colloid replacement fluid. Application of the extra-medullary CHS produced no change in haemodynamic function. However on insertion of the IMHS we found a statistically significant reduction in stroke volume, cardiac output and FTc without changes in pulse rate or mean arterial pressure. The changes were transient with normal cardiac function returning by 5 mins post operatively. Conclusion: The transient fall in cardiac function during insertion of the intramedullary hip screw may be caused by fat embolism entering the venous circulation. As these changes are not detected with standard non-invasive monitoring we would recommend that intramedullary devices be used with caution in elderly patients who tend to have poor physiological reserve


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 85 - 85
1 Jan 2016
Suh Y Nho J Park J Lee Y Ha Y Koo K
Full Access

Introduction

In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty(BH), compression hip screw(CHS) and proximal femur nail antirotatory(PFNA) in treating comminuted intertrochanteric fractures(AO type, A2(21, 22, 23))

Materials and Methods

We retrospectively evaluated total 150 patients(BH:50, CHS:50, PFNA: 50) who were operated due to intertrochanteric fractures from March 2010 to Dec 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris hip score, ability of ambulation(Koval stage), visual analogue scale and radiologic limb length discrepancy(shortening). Landmark and radiologic length was checked.

–A: postoperative length

–A’: POD 1year

–B: immediate posteopative contralateral length(from hip center to distal tip of lesser trochanter)

–B’: POD 1year contralateral length(from hip center to distal tip of lesser trochanter)

Limb length(shortening) was adjusted considering difference of magnification

= {A × (B’/B)}− A’


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 551 - 552
1 Oct 2010
Khunda A Hui A Rookmoneea M
Full Access

Aim: To compare the acute haemoglobin level drop following hip fracture fixation with IMHS and CHS at James Cook University Hospital and assess whether the surgeon’s seniority has any effect on the amount of blood loss in these two procedures.

Methods: Trauma data base was searched for all IMHS procedures performed from January 2002 till March 2007 both included and CHS procedures performed from January 2007 till March 2008 both included.

There were 159 CHS procedures and 146 IMHS procedures. 137 CHS and 123 IMHS procedures fulfilled the blood testing and transfusion criteria.

Haemoglobin levels were used as an indication for blood loss attributable to surgery. The difference between the last level of haemoglobin checked preoperatively and the first post operative level performed between 12–48 hours postoperatively is calculated. Cases where blood transfusion was carried out preoperatively without further preoperative haemoglobin check were excluded, so were cases receiving intra or post operative blood transfusion prior to the defined postoperative haemoglobin check was carried out.

Results: SPSS 13.0 statistical package was used to analyse the results. Levene’s test proved equality of variances of blood loss within the two groups of patients undergoing one of the two procedures, P=0.5. Hence, Independent Samples T test was applicable and showed that patients undergoing an IMHS procedure dropped their haemoglobin levels by 2.96 g/dl. While, those undergoing a CHS procedure dropped their haemoglobin levels by 2.32 g/dl. The 0.64 g/dl difference in haemoglobin drop was statistically significant at 5% significance level with 95% CI (0.27 to 1.01), P=0.001.

The surgeons’ grades were classified into three groups as: Consultants, Registrars and Senior House Officers. Levene’s test again proved the variances of haemoglobin drop within each group to be homogeneous. Hence a One-Way ANOVA test was carried out showing that the differences in haemoglobin drop were not statistically significant when comparing the three groups of surgeons to each other. This was true for both IMHS and CHS procedures.

Conclusion: Patients undergoing a CHS procedure drop their haemoglobin levels by 0.64 g/dl less than those undergoing an IMHS procedure. The surgeon’s seniority does not make difference to the amount of haemoglobin level drop following either of the two procedures.

We recommend the use of CHS for stable fractures and reserve the IMHS for the unstable ones due to the increased blood loss with IMHS procedures.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 41 - 41
1 Feb 2020
Studders C Saliken D Shirzadi H Athwal G Giles J
Full Access

INTRODUCTION. Reverse shoulder arthroplasty (RSA) provides an effective alternative to anatomic shoulder replacements for individuals with cuff tear arthropathy, but certain osteoarthritic glenoid deformities make it challenging to achieve sufficient long term fixation. To compensate for bone loss, increase available bone stock, and lateralize the glenohumeral joint center of rotation, bony increased offset RSA (BIO-RSA) uses a cancellous autograft for baseplate augmentation that is harvested prior to humeral head resection. The motivations for this computational study are twofold: finite element (FE) studies of BIO-RSA are absent from the literature, and guidance in the literature on screw orientations that achieve optimal fixation varies. This study computationally evaluates how screw configuration affects BIO-RSA graft micromotion relative to the implant baseplate and glenoid. METHODS. A senior shoulder specialist (GSA) selected a scapula with a Walch Type B2 deformity from patient CT scans. DICOM images were converted to a 3D model, which underwent simulated BIO-RSA with three screw configurations: 2 divergent superior & inferior locking screws with 2 convergent anterior & posterior compression screws (SILS); 2 convergent anterior & posterior locking screws and 2 superior & inferior compression screws parallel to the baseplate central peg (APLS); and 2 divergent superior & inferior locking screws and 2 divergent anterior & posterior compression screws (AD). The scapula was assigned heterogeneous bone material properties based on the DICOM images’ Hounsfield unit (HU) values, and other components were assigned homogenous properties. Models were then imported into an FE program for analysis. Anterior-posterior and superior-inferior point loads and a lateral-medial distributed load simulated physiologic loading. Micromotion data between the RSA baseplate and bone graft as well as between the bone graft and glenoid were sub-divided into four quadrants. RESULTS. In all but 1 quadrant, APLS performed the worst with the graft having an average micromotion of 347.1µm & 355.9 µm relative to the glenoid and baseplate, respectively. The SILS configuration ranked second, having 211.2 µm & 274.4 µm relative to the glenoid and baseplate. AD performed best, allowing 247.4 µm & 225.4 µm of graft micromotion relative to the glenoid and baseplate. DISCUSSION. Both APLS and SILS techniques are described in the literature for BIO-RSA fixation; however, the data indicate that AD is superior in its ability to reduce graft micromotion, and thus some revision to common practices may be necessary. While these micromotion data are larger than data in the extant RSA literature, there are several factors that account for this. First, to properly model the difference between locking and compression screws, we simulated friction between the compression screw heads and baseplate rather than a tied constraint as done in other studies, resulting in larger micromotion. Second, the trabecular bone graft is at greater risk of deforming than metallic spacers used when studying micromotion with glenosphere lateralization, increasing graft deflection magnitude. Future work will investigate the effects of various BIO-RSA variables. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 79 - 79
7 Aug 2023
Houston J Everett S Choudhary A Middleton S Mandalia V
Full Access

Abstract. Introduction. Symptomatic osteochondritis dissecans (OCD) and traumatic osteochondral fractures (OCF) are treated with fixation with either metal or bioabsorbable device. We performed a comparative review of patients with OCD and traumatic OCF stabilised with Bio-Compression screws which are headless absorbable compression screws. Our aim was to determine whether there was a difference in outcomes between presentations. Methods. Retrospective single-centre cohort study of all patients with OCD and OCF treated with Bio-Compression screw between July 2017 and September 2022. All patients followed up until discharge with satisfactory clinical outcome. Primary outcome was return to theatre for ongoing pain or mechanical symptoms. Secondary outcome was evidence of fixation failure on follow-up MRI scan. Results. 20 patients included; 8 OCF and 12 OCD. Average age 21 (OCF), 24 (OCD). The most common location was patella (58%) in OCF or the medial femoral condyle (75%) in OCD. Traumatic defects were smaller (2.6cm2 vs 3.3cm2) although this was not statistically significant (p=0.28). In the OCF group one patient went on to have further surgery. There were no re-operations in the OCD group. Both groups had good outcomes and similar times to discharge. There was no evidence of fixation failure of Bio-Compression screws on MRI scans. Conclusions. Within the limits of this relatively small cohort there is no significant difference between outcomes for OCD or traumatic OCF fixation with Bio-Compression screws. Both groups demonstrate good outcomes irrespective of the location or the aetiology of the fragment


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 25 - 25
8 May 2024
Parsons A Parsons S
Full Access

Background. Whereas arthroscopic arthrodesis of the ankle is commonplace and of the subtalar joint is established, reports of arthroscopic talo-navicular fusion are a rarity. Aim. To review a case series to establish if arthroscopic talo-navicular arthrodesis is a feasible surgical option. Methods. Arthroscopic decortication of the talo-navicular joint is performed via x1-2 sinus tarsi portals and x1-2 accessory talo-navicular portals using a standard arthroscope and a 4.5 barrel burr. Internal fixation is by a 5mm screw from the navicular tuberosity and x2 headless compression screws introduced under image intensification from the dorsal navicular to the talar head. Between 2004 and 2017 a consecutive series of 164 patients underwent arthroscopic hindfoot arthrodeses of which 72 involved the talo-navicular joint. Only 13 procedures were of that joint alone in unsullied feet. The medical records of these 13 patients were reviewed to assess radiological fusion, complications and improvement of pre-operative state. Results. All Talo-navicular joints were successfully decorticated. All united radiologically by a mean 4.4 months (range 3–8). There were no major complications. All patients reported improvement to their pre-operative symptoms but one patient developed lateral column pain requiring fusion. Conclusions. Arthroscopic Talo-navicular arthrodesis is technically feasible with good rates of union. Complications were rare, making the technique attractive when encountering a poor soft tissue envelope. The surgery cannot be used if bone grafting is required. Long term discomfort can arise from adjacent joints. Accurate alignment is critical


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 110 - 110
10 Feb 2023
Kim K Wang A Coomarasamy C Foster M
Full Access

Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the headless compression screws (HCS), however there has been no cost analysis to compare the two. Therefore, this study aims to 1) review the cost of DIPJ fusion between k-wire and HCS 2) compare functional outcome and patient satisfaction between the two groups. A retrospective review was performed over a nine-year period from 2012-2021 in Counties Manukau. Cost analysis was performed between patients who underwent DIPJ fusion with either HCS or k-wire. Costs included were surgical cost, repeat operations and follow-up clinic costs. The difference in pre-operative and post-operative functional and pain scores were also compared using the patient rate wrist/hand evaluation (PRWHE). Of the 85 eligible patients, 49 underwent fusion with k-wires and 36 had HCS. The overall cost was significantly lower in the HCS group which was 6554 New Zealand Dollars (NZD), whereas this was 10408 NZD in the k-wire group (p<0.0001). The adjusted relative risk of 1.3 indicate that the cost of k-wires is 1.3 times more than HCS (P=0.0053). The patients’ post-operative PRWHE pain (−22 vs −18, p<0.0001) and functional scores (−38 vs −36, p<0.0001) improved significantly in HCS group compared to the k-wire group. Literatures have shown similar DIPJ fusion outcomes between k-wire and HCS. K-wires often need to be removed post-operatively due to the metalware irritation. This leads to more surgical procedures and clinic follow-ups, which overall increases the cost of DIPJ fusion with k-wires. DIPJ fusion with HCS is a more cost-effective with a lower surgical and follow-up costs compared to the k-wiring technique. Patients with HCS also tend to have a significant improvement in post-operative pain and functional scores


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 18 - 18
14 Nov 2024
Rau Y Amtsfeld J Reimers N Behrends L Hinz N Schulz AP
Full Access

Introduction. Hip fractures, with a global age-standardised incidence rate (per 100,000 population) of 187.2 (2019), are a major public health problem. With a 7.71 billion population worldwide in 2019, hip fractures, in general, are affecting around 14.43 million people per year globally. We aim to provide a nationwide epidemiological analysis of trochanteric fractures and their respective surgical treatments. In this study we research the epidemiology of trochanteric and subtrochanteric fractures, as well as their most common kinds of osteosynthesis, on a nationwide scale in Germany. Method. Data was retrieved from the national database of the German Ministry of Interior. ICD-10-GM and OPS-data from the period of 2006-2020 were analyzed, all patients with trochanteric/subtrochanteric fractures were included. Patients were grouped by age/gender and linear-regression was performed to calculate statistically significant correlations between variables/incidences. Result. 985,104 trochanteric and 178,810 subtrochanteric-fractures were reported during the analyzed period. This calculates to a mean incidence of 80.08±6.34 for pertrochanteric and 14.53±1.50 for subtrochanteric fractures per-million-inhabitants. In both fracture-types, a distinct dependence of incidence on age can be seen. Incidence rates equally rise in both sexes through the age groups with an increase of about 288-fold from those under 60 to those over the age of 90 in pertrochanteric fractures. Intramedullary nailing was the most common kind of treatment for both fracture types with augmentative cerclages on the rise throughout the whole period. Dynamic compression screws were decreasing in frequency. Conclusion. We found an ongoing increase of incidence among the elderly and an increase in intramedullary nailing as well as augmentative cerclages. Not only could we show an age-dependence of the incidences, but also a sex-dependence that seems to remain consistent in its development. While younger males (<60 years) are at a higher risk than their female peers, older females are at significantly higher risk than their male peers


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 52 - 52
1 Apr 2019
Roche C Yegres J Stroud N VanDeven J Wright T Flurin PH Zuckerman J
Full Access

Introduction. Aseptic glenoid loosening is a common failure mode of reverse shoulder arthroplasty (rTSA). Achieving initial glenoid fixation can be a challenge for the orthopedic surgeon since rTSA is commonly used in elderly osteoporotic patients and is increasingly used in scapula with significant boney defects. Multiple rTSA baseplate designs are available in the marketplace, these prostheses offer between 2 and 6 screw options, with each screw hole accepting a locking and/or compression screw of varying lengths (between 15 to 50mm). Despite these multiple implant offerings, little guidance exists regarding the minimal screw length and/or minimum screw number necessary to achieve fixation. To this end, this study analyzes the effect of multiple screw lengths and multiple screw numbers on rTSA initial glenoid fixation when tested in a low density (15pcf) polyurethane bone substitute model. Methods. This rTSA glenoid loosening test was conducted according to ASTM F 2028–17; we quantified glenoid fixation of a 38mm reverse shoulder (Equinoxe, Exactech, Inc) in a 15 pcf low density polyurethane block (Pacific Research, Inc) before and after cyclic testing of 750N for 10k cycles. To evaluate the effect of both screw fixation and screw number, glenoid baseplates were constructed using 2 and 4, 4.5×18mm diameter poly-axial locking compression screws (both n = 5) and 2 and 4, 4.5×46mm diameter poly-axial locking compression screws (both n = 5). A two-tailed unpaired student's t-test (p < 0.05) compared prosthesis displacements to evaluate each screw length (18 vs 46mm) and each screw number (2 vs 4). Results. All glenoid baseplates remained well-fixed after cyclic loading in the low density bone substitute block, regardless of screw length or screw number. As described in Table 1, the average pre- and post-cyclic displacement for baseplates with 18mm long screws was significantly greater than that of baseplates with 46mm long screws in both the A/P and S/I directions, with exception of displacements for 4 screws S/I-pre cyclic and 2 screws A/P-post cyclic loading. As described in Table 2, the average pre- and post-cyclic displacement for all baseplates with 2 screws was significantly greater than that of all baseplates with 4 screws, regardless of screw length in the A/P and S/I directions. Discussion and Conclusions. These results of this study demonstrate that rTSA glenoid baseplate fixation is impacted by both the number of screws and by the length of screws, with longer screws and more screws associated with significantly better initial fixation. However, it should be noted that none of the tested devices catastrophically failed in this non-defect/low-density model, demonstrating that adequate fixation can be achieved with as little as 2×18mm screws for some baseplate types. Care should be made when extrapolating these results to that of other designs. This study is limited by its use of only one implant design and by its use of a polyurethane substrate without any defect; future work should evaluate the effect of screw length and screw number in with multiple different prostheses in different densities of bone with and without defects


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 94 - 94
1 Jul 2020
Undurraga S Au K Salimian A Gammon B
Full Access

Longstanding un-united scaphoid fractures or scapholunate insufficiency can progress to degenerative wrist osteoarthritis (termed scaphoid non-union advanced collapse (SNAC) or scapho-lunate advanced collapse (SLAC) respectively). Scaphoid excision and partial wrist fusion is a well-established procedure for the surgical treatment of this condition. In this study we present a novel technique and mid-term results, where fusion is reserved for the luno-capitate and triquetro-hamate joints, commonly referred to as bicolumnar fusion. The purpose of this study was to report functional and radiological outcomes in a series of patients who underwent this surgical technique. This was a prospective study of 23 consecutive patients (25 wrists) who underwent a bicolumnar carpal fusion from January 2014 to January 2017 due to a stage 2 or 3 SNAC/SLAC wrist, with a minimum follow-up of one year. In all cases two retrograde cannulated headless compression screws were used for inter-carpal fixation. The clinical assessment consisted of range of motion, grip and pinch strength that were compared with the unaffected contralateral side where possible. Patient-reported outcome measures, including the DASH and PRWE scores were analysed. The radiographic assessment parameters consisted of fusion state and the appearance of the radio-lunate joint space. We also examined the relationship between the capito-lunate fusion angle and wrist range of motion, comparing wrists fused with a capito-lunate angle greater than 20° of extension with wrists fused in a neutral position. The average follow-up was 2.9 years. The mean wrist extension was 41°, flexion 36° and radial-ulnar deviation arc was 43° (70%, 52% and 63% of contralateral side respectively). Grip strength was 40 kg and pinch strength was 8.9 kg, both 93% of contralateral side. Residual pain for activities of daily living was 1.4 (VAS). The mean DASH and PRWE scores were 19±16 and 29±18 respectively. There were three cases of non-union (fusion rate of 88%). Two wrists were converted to total wrist arthroplasty and one partial fusion was revised and healed successfully. Patients with an extended capito-lunate fusion angle trended toward more wrist extension but this did not reach statistical significance (P= 0.07). Wrist flexion did not differ between groups. Radio-lunate joint space narrowing progressed in 2 patients but did not affect their functional outcome. After bicolumnar carpal fusion using retrograde headless screws, patients in this series maintained a functional flexion-extension arc of motion, with grip-pinch strength that was close to normal. These functional outcomes and fusion rates were comparable with standard 4-corner fusion technique. A capito-lunate fusion angle greater than 20° may provide more wrist extension but further investigation is required to establish this effect. This technique has the advantage that compression screws are placed in a retrograde fashion, which does not violate the proximal articular surface of the lunate, preserving the residual load-bearing articulation. Moreover, the hardware is completely contained, with no revision surgery for hardware removal required in this series


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 211 - 211
1 May 2006
Rydholm U Andersson T Linder L Maxander P Besjakov J Montgomery F Carlsson A
Full Access

25 RA patients with their ankles fused with an intramedullary nail were compared to 35 RA patients with their ankles fused with compression screws. 24/25 nailed patients showed radiographic healing at follow-up after 3 (1–8) years, and 26/35 ankles in the compression screw group examined after 6 (1–14) years healed after the first attempt and another 5 after repeat surgery. In the nailed group 23 patients were satisfied and 2 somewhat satisfied. In the compression screw group 20 were satisfied, 12 somewhat satisfied and 3 dissatisfied. There were 4 deep infections (3 healed after nail extraction and antibiotics, one unhealed) in the nail group and 1 deep infection (healed after antibiotics) in the compression screw group. Six patients in the nailed group also had a permanent plantar sensory loss. Conclusion: Ankle fusion with retrograde intramedullary nailing seems to result in a high rate of healing and satisfied patients, but cares a substantial risk of deep infection compared to fusion with compression screws, which has a lower fusion rate fewer satisfied patients, but less complications. RA patients with a normal subtalar joint are of course only managed by compression screws


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 94 - 94
1 Apr 2018
Patel A Li L Qureshi A Deierl K
Full Access

Introduction. Hoffa fractures are rare, intra-articular fractures of the femoral condyle in the coronal plane and involving the weight-bearing surface of the distal femur. Surgical fixation is warranted to achieve stability, early mobilisation and satisfactory knee function. We describe a unique type of Hoffa fracture in the coronal plane with sagittal split and intra-articular comminution. There is scant evidence in current literature with regards to surgical approaches, techniques and implants. We report of our case with a review of the literature. Case report. A 40 year old male motorcyclist was involved in a high speed road traffic collision. X-rays confirmed displaced unicondylar fracture of the lateral femoral condyle. CT showed sagittal split of the Hoffa fragment and intra-articular comminution. MRI showed partial rupture of the anterior cruciate ligament. The patient underwent definitive surgical treatment via a midline skin incision and lateral parapatellar approach using cannulated screws, headless compression screws and anti-glide plate. Weightbearing was commenced at 8 weeks. Arthroscopy and adhesiolysis was performed at 12 weeks to improve range of motion. The patient was discharged at one year with a pain-free, functional knee. Discussion. Hoffa fractures are high-energy fractures, often seen in young male motorcyclists with flexed and slightly abducted knee. Most papers recommend surgical fixation, however there is no widely accepted surgical method or rehabilitation regime. Varying surgical approaches, screw direction, choice of implants, and post-operative care have been described. Surgical approach depends on the configuration of the fracture. The medial/lateral parapatellar approach is commonly used as it does not compromise future arthroplasty, but it does not allow access to fix posterior comminution. Arthroscopic-assistance may be used with good outcomes and less tissue dissection. AP screws are widely reported in the literature, most likely due to easier access to the fracture site. PA screws may provide better stability, but access is more difficult. Fixation often involves passing screws through the articular surface, therefore the area damaged should be kept to a minimum by using the smallest possible screw; headless compression screws leave a smaller footprint in the articular cartilage. Locking plate augmentation generally gives good outcomes. Conclusion. Hoffa fractures are rare and difficult to treat. Surgical treatment is the best choice for optimum post-operative knee function. There is no consensus on choice of surgical approaches, techniques and implants, as these are dependent on fracture configuration. In this particular case we emphasise the importance of using an anti-glide plate to address the sagittal component. Despite the need for a secondary procedure, the treatment has had positive outcomes and may be used as a guide for treatment of future Hoffa fractures of a similar sub-type