Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 188 - 188
1 Mar 2010
Fearon A Smith P Dear K Scarvell J
Full Access

Severe and recalcitrant Greater Trochanteric Pain Syndrome (GTPS), previously known as Trochanteric bursitis, has been associated with torn gluteal tendons. The aim of this study was to assess the physical, functional and quality of life outcomes of combined bursectomy and gluteal tendon reconstructive surgery. 24 patients underwent combined bursectomy and gluteal tendon reconstruction under one surgeon. They were contacted by mail, email, and telephone. 16 were available for examination, two had revision surgery, one had interview only, one moved interstate, one declined and three were lost to follow up. An independent standardised assessment was undertaken. Hip muscle strength was measured by hand-held dynamometry. Trendelenburg sign was measured according to Hard-castle’s protocol and by observing gait. Functional and quality of life measures were assessed via the Harris Hip Score and the Oswestry Disability scale. Pain and satisfaction was measured via a 10cm visual analogue scale. All patients were female. The mean time from surgery was 18.9 months +/− 8.50. 10 had right sided surgery. The two patients who had revision surgery are not included in this data. Strength of hip abduction was weaker on the ipsilateral side (p< =.05). External rotation appeared to be weaker, however this was not statistically significant. Hardcastle’s single leg standing Trendelenburg sign was shorter on the ipsilateral side (16.3secs +/− 12.3 vs 22.1secs +/− 10.1, p< =.05). Five patients had an ipsilateral Trendelenburg gait, two had a contralateral Trendelen-burg gait. The mean recalled preoperative pain score was 67.73 +/− 31.51 out of 100. The mean post operative score was 14.44 +/− 16.1 (p< =.0005). Patient satisfaction with the results of surgery was rated at 80.7 +/−17.69, out of 100. With regard to function, the mean post operative Harris hip score was 70.9 +/− 25.73 out of 91, and the Oswestry disability score was 15.5 +/− 11.39, out of 100 where a low score indicates better outcome. Combined bursectomy and gluteal tendon reconstruction appears to be an effective procedure for the relief of pain in patients with recalcitrant GTPS in most patients. High patient satisfaction levels suggest that function and quality of life are improved following surgery. A prospective longitudinal study has commenced to verify these results


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 199 - 199
1 Apr 2005
Rosa D Maffulli N Corriero A Iacono V Leopardi P
Full Access

Neglected rupture of quadriceps tendon is an infrequently occurring lesion resulting from sport, but it is very interesting as regards the physiological and functional repercussions. The lesion is common in football players. The pathogenesis is a flexion trauma of knee. Many authors point out the importance of a pre-existent degeneration due to exogenous and endogenous factors. Pain, inextensible knee, ecchymosis, axe hit are a common presentation in acute events, difficult knee extension and pain in chronic. X-ray study shows calcification at the tendon-bone junction.

The treatment of neglected rupture of quadriceps tendon is surgical. If a defect of 5 cm or more is present between the ends of tendon the fascia lata can be used to correct the gap. When the ends can be apposed an end-to-end repair is possible. We treated a neglected rupture of quadriceps femoris muscle tendon in a bodybuilder with a particular technique: we stripped and harvested the semitendinosus and gracilis tendon and sutured them together. Then we made a transverse hole in the mid-portion of the patella; the tendons were passed through the transverse hole in the patella and sutured with the lateral, medial and intermendial vastus, and with the rectum femoral. At 6-month follow-up the patient has no pain and stability is improved, a practical range of knee motion regained. Full forceful extension is not completely restored.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 424 - 424
1 Jul 2010
Trickett RW Wilson C
Full Access

We describe a new method for reconstructing the patellar tendon following combined injury to the patellar tendon and anterior cruciate ligament (ACL).

Combined injuries to the patellar tendon and the ACL represent a rare and potentially serious injury pattern. The injury to the patellar tendon can often go undiagnosed at primary presentation. Reconstructive options for the patellar tendon are described but can be technically difficult, particularly if ipsilateral hamstring has been used for anterior cruciate ligament reconstruction. Evidence suggests combined injuries generally lead to poor long term outcome.

We describe a case of a 26 year old male who presented with a reconstructed ACL and a patellar tendon deficient knee. Diagnosis was confirmed on Magnetic Resonance Imaging (MRI). Ipsilateral hamstrings had been used as donor for ACL reconstruction. An Achilles tendon allograft with distal bone block was used in combination with contralateral semitendinosus and gracilis autograft to reconstruct the three bundles of the patellar tendon. The patient experienced no postoperative complications and was followed up radiologically and clinically. Computer Topography imaging performed at 6 months post-operatively showed union of the bony Achilles tendon block. MRI performed 1 year post-operatively showed good incorporation of the tendinous grafts and no evidence of degeneration or tearing. Oxford knee score at 6 months post-operatively was 31/48. One year post-operatively full pre-injury activity level had been achieved.

We believe this method to provide adequate strength and integrity, enabling early rehabilitation following this rare injury. It has also been shown to give a good functional outcome.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 2 - 2
22 Nov 2024
Roskar S Faganeli N Mihalic R Trebse R
Full Access

Aim. Arthroscopic interventions have revolutionized the treatment of joint pathologies. The appropriate diagnostics and treatment are required for infections after ligament reconstructions using non-resorbable material such as tendon grafts, anchors, and sutures, prone to biofilm formation. The infection rate is around 1% for knee and shoulder, while up to 4% for Achilles tendon reconstructions. Despite high number of these procedures worldwide, there is limited evidence about the best treatment protocol. Our study aimed to provide a general protocol for the treatment of small implants for soft tissue reconstruction. Method. Between 2019 and 2023, we treated 48 infections of ligament, meniscus, and tendon reconstructions out of 7291 related procedures performed in the same time period. Early infection (<30 days) were treated with an arthroscopic debridement and implant retention (DAIR), except Achilles tendons had open DAIR, while those with delayed or chronic infection (>30 days) were treated with extensive debridement and lavage combined with one-stage exchange (OSE) or implant removal. During surgery, at least 5 microbiological s and samples for histopathology were obtained. The removed material was sonicated. After surgery, all patients were one week on iv. antibiotics, followed by oral antibiofilm antibiotics for 6 weeks including rifampicin and/or a quinolone. All patients were followed for at least 1 year. Failure was defined as the need for additional revision surgery after finished iv. antibiotic treatment. Results. Among 48 patients, 38 were early and 10 were late acute or chronic infections. The incidence of infection for our cohort was 0.7%. We observed 27 infections after ligament reconstruction of the knee, 15 of the shoulder, 5 of the ankle, and 1 infection of the elbow joint. 40 patients were treated with DAIR, 5 with OSE, and 3 with implant removal. We had 11 C. acnes, 10 S. aureus, 6 S. epidermidis, 2 P. aeruginosa, 2 S. lugdunensis, 10 mixed flora, and 3 culture-negative infections. 12 patients received antibiotics before surgery, and all culture-negative infections were related to this subgroup. We observed 2 failures, both in a combination of proximal tibial osteotomy and ligament reconstruction of the knee joint. The success rate of our protocol was 96%. Conclusions. Prompt surgical treatment followed by 6 weeks of antibiotic treatment cured 96% of infections of small implants after reconstruction procedures of knee, shoulder, and ankle joints. Our study is the first to provide a treatment protocol for infections of small implants after ligament reconstruction procedures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 5 - 5
1 Feb 2020
Jenny J Guillotin C Boeri C
Full Access

Introduction. Chronic ruptures of the quadriceps tendon after total knee arthroplasty (TKA) are rare but are a devastating complication. The objective of this study was to validate the use of fresh frozen total fresh quadriceps tendon allografts for quadriceps tendon reconstruction. The hypothesis of this work was that the graft was functional in more than 67% of cases, a higher percentage than the results of conventional treatments. Material – methods. We designed a continuous monocentric retrospective study of all patients operated on between 2009 and 2017 for a chronic rupture of the quadriceps tendon after TKA by quadriceps allograft reconstruction. The usual demographic and perioperative data and the rehabilitation protocols followed were collected. Initial and final radiographs were analyzed to measure patellar height variation. The main criterion was the possibility of achieving an active extension of the knee with a quadriceps contraction force greater than or equal to 3/5 or the possibility of lifting the heel off the ground in a sitting position. Results. 29 patients with 33 allografts were included; 3 iterative allografts were performed on ruptures of the initial transplant and 1 patient was grafted on both sides in one step. There were 21 women and 8 men with a mean age of 73 years, and a mean body mass index of 33 kg/m. 2. Ruptures occurred in 22 cases after chronic periprosthetic infection. Walking was allowed immediately in 29 cases, but free mobilization was delayed in 29 cases. Complications affected 22 cases, but the majority of complications were not related to allograft use (including infectious failures and periprosthetic fractures). After a mean follow-up of 52 months, 28 allografts were still in place, and 22 allografts were considered functional. The active quadriceps extension force was rated on average at 3.5/5. The average pre/post-operative patellar height differential was +2 mm. Discussion. This continuous series of 33 allografts is in line with recent publications on the subject. It confirms their negative impact on the functional outcome of the TKA. The complication rate is high but the specific complication rate is not prohibitive. Two thirds of transplants are functional in the long term. Early rehabilitation procedures can be used in these difficult patients with encouraging results. The management of chronic ruptures of the quadriceps tendon after TKA by quadriceps allograft must be part of the current therapeutic options


Bone & Joint Research
Vol. 12, Issue 1 | Pages 72 - 79
18 Jan 2023
Welling MM Warbroek K Khurshid C van Oosterom MN Rietbergen DDD de Boer MGJ Nelissen RGHH van Leeuwen FWB Pijls BG Buckle T

Aims

Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (99mTc-UBI29-41-Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods.

Methods

99mTc-UBI29-41-Cy5 specificity for Stapylococcus aureus was assessed in vitro using fluorescence confocal imaging. Topical administration was used to highlight the location of S. aureus cultured on femoral prostheses using fluorescence imaging and freehand single photon emission CT (fhSPECT) scans. Gamma counting and fhSPECT were used to quantify the bacterial load and monitor cleaning with chlorhexidine. Microbiological culturing helped to relate the imaging findings with the number of (remaining) bacteria.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims

The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs).

Methods

This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 163 - 164
1 Feb 2003
Mann C Costi J Stanley R Clarnette R Campbell D Angel K Dobson P
Full Access

The effect of screw geometry on the pullout strength of Anterior Cruciate Ligament [ACL] reconstruction is well documented. Most research has looked at the effect of screw length and diameter, however other factors such as the degree of taper may also be important. Tapered screws should in theory be associated with increased pullout strength. This has not been demonstrated either clinically or in vitro before. The aim of this study was to compare the pullout strength of ACL reconstruction with a parallel against a tapered screw. A parallel and tapered screw were manufactured which were identical in all other respects. Sixty superficial digital flexors from the hind legs of sheep were harvested. The tendons were paired and combined to form a quadruple tendon reconstruction of approximately 7mm diameter as measured with graft sizer. An ACL reconstruction was performed on the proximal tibia of 30 bovine knees, which had been harvested in right and left knee pairs, using the quadruple tendon. Fifteen reconstructions were fixed using tapered screws and fifteen with non-tapered screws. The insertion torque of both tapered and non tapered screws were recorded using an instrumented torque screwdriver. The reconstructions were mounted in an Instron materials testing machine with an x-ray bearing system to eliminate horizontal forces, to ensure that the forces were all directed along the line of the tibial tunnel. The maximum pullout strengths were recorded in each case. Five knee pairs were subjected to bone densitometry scanning to ensure that any difference in pull out strength was not due to changes in bone density between right and left knee pairs. Results indicated that there was no difference between right and left knee pairs [p = 0.58] and that tapered screws were associated with significantly higher pull-out strengths [p=0.007] and insertion torques [p = 0.001]


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 58 - 58
1 Sep 2012
Young A Evans S
Full Access

This study was undertaken to assess for equivalence or superiority in tendon reconstruction techniques. This is an in vitro analysis of several, different, reconstruction techniques for chronic Achilles tendon ruptures. The surgical techniques have been borne out of surgical preference rather than biomechanical principles with little published research into their comparability. Surgical preferences are a result of the supposed benefits of reduced operative time, single operative incision and decreased morbidity. An animal model, after human cadaveric tissue dissection to guide the specimen construction, was used to compare the different techniques using bovine bone and tendon and tested using a material testing machine. Ultimate load to failure was recorded for all specimens and statistical analysis of the results was undertaken. A statistically significant difference was shown between all the techniques by analysis of variance. This will guide clinical application of these techniques. The use of bone tunnels, through which the flexor hallucis longus tendon can be passed, were found to be biomechanically superior, with regard to ultimate load to failure, to either bone anchors or end-to-end tendon suture techniques. Interference screws were found to have a large range in their ultimate load suggesting a lack of consistency in the results. The mean of the bone tunnel group (482.8N, SD 83.6N) is significantly (p < 0.01) higher than the mean of the bone anchor group (180.2N, SD 19.3N), which is, in turn, significantly (p < 0.01) higher than the mean of the Bunnell group (73.7N, SD 20.9N). This study is larger than any previous study found in the literature with regard to number of study groups and allows the techniques to be compared side by side


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 174 - 174
1 Sep 2012
Rogers B Kuchinad R Garbedian S Backstein D Safir O Gross A
Full Access

Introduction. A deficient abductor mechanism leads to significant morbidity and few studies have been published describing methods for reconstruction or repair. This study reports the reconstruction of hip abductor deficiency using human allograft. Methods. All patients were identified as having deficient abductor mechanisms following total hip arthroplasty through radiographic assessment, MRI, clinical examination and intra-operative exploration. All patients underwent hip abductor reconstruction using a variety of human allografts including proximal humeral, tensor fascia lata, quadriceps and patellar tendon. The type of allograft reconstruction used was customized to each patient, all being attached to proximal femur, allograft bone adjacent to host bone, with cerclage wires. If a mid-substance muscle rupture was identified an allograft tendon to host tendon reconstruction was performed. Results. Allograft reconstruction was performed in 15 patients over 18 months. One patient had an abductor deficiency after a primary total hip. All patients had an abductor lurch gait and positive Trendelenburg test preoperatively. Manual muscle strength testing showed significant weakness with a mean MRC grade of 3+/5. Peri-trochanteric pain was cited as a significant complaint in > 80 % of patients. Proximal humeral allografts, with rotator cuff, were used in 8 patients, 5 had tensor fascia lata and the remainder had patella with attached tendon allograft. The majority of patients had a reduction in pain and 8/15 (53%) increased their abductor strength by almost a full grade. A reduced lurch was observed in 10 (66%) patients and one patient re-dislocated after a failed revision for instability. Conclusion. To our knowledge, this is the largest reported series of allograft reconstruction for a deficient abductor mechanism following hip arthroplasty. A viable solution is demonstrated, with promising early results for a difficult problem, utilizing a straightforward technique with low morbidity


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 346 - 346
1 May 2009
Chen J Willers C Xu J Wang A Zheng M
Full Access

Large and retracted rotator cuff tendon tears fail to repair, or re-tear following surgical intervention. This study attempted to develop novel tissue engineering approaches using tenocytes-seeded bioscaffolds for tendon reconstruction of massive rotator cuff tendon defect in rabbits. Porcine small intestine submucosa (Restore™) and type I/III collagen bioscaffold (ACI-MaixTM) were chosen as bioscaffold carriers for autologous tenocytes. Biological characterization of autologous tenocytes was conducted prior to the implantation. The tenocyte-seeded bioscaffolds were implanted as interposition grafts to reconstruct massive rotator cuff tendon defects in rabbits. In situ re-implantation of the autologous rotator cuff tendon, excised during defect creation served as a positive control. Histological outcomes were analysed and semi-quantitatively graded at four and eight weeks after surgery. The results demonstrate that at four weeks both tenocyte-seeded bioscaffolds display inflammatory reaction similar to bioscaffold-only cuff reconstruction and the histological grading were inferior to control repair. However, at eight weeks inflammatory reaction of both tenocyte-seeded bioscaffolds were dramatically reduced as compared to bioscaffold alone. In addition, bioscaf-folds seeded with tenocytes generated similar histological appearance to that of the positive control. The implantation of autologous tenocytes on collagen-based bioscaffold offers improved rotator cuff tendon healing and remodelling compared to the implantation of bioscaffold alone


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 21 - 21
1 Mar 2009
Abalo E Farfalli G Politi B Aponte-Tinao L Ayerza M Muscolo D
Full Access

Pupose: The purpose of this study was to analyze the outcome of proximal tibia osteoarticular allografts after tumor resections. Material amd Methods: We performed a retrospective study over 58 patients in which a proximal tibia allograft reconstruction was undertaken. All patients were followed for a minimum of 5 years and allografts survival from the date of implantation to the date of revision or the time of the latest follow-up was determined with the use of the Kaplan-Meier method. In all patients, the patellar tendon from the host was reattached by suturing to overlapped donor flaps. Patients were clinically evaluated with the MSTS score system. Results: The global rate of allograft survival was 65% +/− 12% (+/− 2 SE) at five and ten years, with no significant difference between patients who received chemotherapy and those who did not. Allografts needed to be removed in twenty patients due to 12 infection, 4 local recurrences and 4 fractures. Active knee extension was restored in all patients with an average functional score of 26.3 points. Discussion: Survival analysis showed that 65% of proximal tibia osteoarticular allograft reconstructions remain stable at five and ten years. Patellar tendon reconstruction with allogeneic tissue in proximal tibia allograft restores active knee extension with an excellent functional result. Despite the incidence of complications, proximal tibia osteoarticular allografts continue to be a very valuable reconstructive procedure for large defects after resection of bone tumors


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 180 - 180
1 Mar 2006
Mota da Costa J Pinto A
Full Access

Material & Methods: Twenty three patients (15 male; 8 female) with an average 30 years old (16–63) presented with a posttraumatic multidirectional instability of the distal RU joint. In two occasions instability was associated to a malunited distal radial fracture which was corrected with a osteotomy. Through a dorsoulnar approach, the RU joint in all cases was inspected and found with no cartilage defects that could preclude this intervention. Also in all occasions there was an unrepairable peripheral TFCC detachment. In 11 cases the palmaris longus tendon was utilized, while in one the flexor superficialis of the ring finger was used. The graft was passed through an anteroposterior tunnel in the distal-medial edge of the radius and attached into another tunnel in the basistyloid fovea. The forearm was then immobilized in neutral pronosupination for 4–6 weeks, followed by appropriate physiotherapy. Results: At an average 18 months follow-up (6–36) 21 patients regained radioulnar stability (symmetrical passive displacement of the joint relative to the contralateral side). In two there was a limitation of more than 25° pronosupination. All 15 patients with a follow-up longer than one year had returned to their previous activities with a less than 20% loss of grip strength. Conclussion: Tendon reconstruction as suggested by Adams& Berger is anatomically sound, and it has shown promising short term results, certainly superior to the results obtained with other soft-tissue reconstructions


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 212 - 212
1 May 2006
Ryu JJ Ishii TT Nagaoka MM
Full Access

The recent advance of drug therapy for RA tends to replace preventive surgery, for example synovectomy. A rupture of a dorsal extensor tendon of the hand is an absolute indication for surgery, however. Such tendon ruptures are usually treated by tendon reconstruction and synovectomy of wrist joint. At our department, reconstructive surgery was administered with synovectomy for extensor tendon ruptures of the hand in 97 hands for 86 patients until June 2005. Recently, however, we occasionally encounter ruptures of extensor tendons not associated with severe synovitis. To treat such tendon ruptures, we usually administer tendon transfers in combination with tenosynovectomy through a small skin incision. Because this surgical procedure has achieved excellent results, we report our experience. This study included 15 patients who received tenosynovectomy in combination with tendon transfers in 14 hands since February 2001. This surgical procedure is indicated for tendon ruptures associated with mild synovitis (swelling) without instability on the ulnar distal end. As a rule, a 2–3 cm transverse skin incision was made on the dorsum of the hand under maxillary nerve block. After exposure of the distal ruptured end of the tendon, tenosynovectomy was administered through the incision. Then, the distal end was transferred to the adjacent normal tendon and fixed to it with sutures. Postoperatively, the repair was immobilized with bandage. The patient was allowed actively to extend and bend the hand on the next day. As a rule, this operation is administered on an outpatient basis. The postoperative course was uneventful, without rupture of the repair. The preoperative ranges of motion of the MP and PIP joints were retained postoperatively without difficulty in ADL


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 356 - 356
1 Mar 2004
Darlis NA Beris A Korompilias A Vekris M Mitsionis G Soucacos P
Full Access

Aim: Although primary ßexor tendon repair in children yields satisfactory results, some children end up with poor function because of delay in diagnosis, technical difþculties and the inability to follow a structured rehabilitation program. The aim of this study is to evaluate the functional outcome after two stage reconstruction with the modiþed Paneva technique (which includes creating a loop between the proximal stumps of Flexor Digitorum Profundus and Superþcialis in the þrst stage and reßecting the latter as a Ç pedicled È graft through the pseudosheath created around the silicone rod, in the second stage) in children. Methods: Nine patients (9 digits) with a mean age of 8,2 years (range 3 Ð15) were treated for zone II lesions. Their pre-operative status in the Boyes and Hunter scale was grade two in 3, grade three in 3, grade four in 1 and grade þve in 2 patients. Results: After a mean of 42 months of follow-up (minimum 12 months), according to the Buck-Gramco scale there were 4 excellent, 4 good and 1 poor result and according to the revised Strickland scale 3 excellent, 5 good and 1 poor. Children over the age of 10 had slightly improved Total Active Motion (mean +350) compared to younger ones. No signiþcant length discrepancies were noted. Two postoperative infections were treated and one graft-related re-operation was necessary. Conclusions: Staged ßexor tendon reconstruction in children is technically feasible and efþcient. Delaying such a reconstruction in younger children does not seem justi-þed


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 224 - 224
1 Mar 2003
Darlis N Beris A Korobilias A Vekris M Mitsionis G Soucacos P
Full Access

Although primary flexor tendon repair in children yields satisfactory results, some children end up with poor function because of delay in diagnosis, technical difficulties and the inability to follow a structured rehabilitation program. The aim of this study is to evaluate the functional outcome after two stage reconstruction with the modified Paneva technique (which includes creating a loop between the proximal stumps of Flexor Digitorum Profundus and Superficialis in the first stage and reflecting the latter as a “pedicled” graft through the pseudosheath created around the silicone rod, in the second stage) in children. Nine patients (nine digits) with a mean age of 8.2 year (range 3–15) were treated for zone II lesions. Their pre- operative status in the Boyes and Hunter scale was grade 2 in three, grade 3 in three, grade 4 in one and grade 5 in two patients. After a mean of 42 months of follow-up (minimum 12 months), according to the Buck-Gramco scale there were four excellent, four good and one poor result and according to the revised Strickland scale three excellent, five good and one poor. Children over the age of 10 had slightly improved Total Active Motion (mean +35°) compared to younger patients. No significant length discrepancies were noted. Two postoperative infections were treated and one graft-related re-operation was necessary. Staged flexor tendon reconstruction in children is technically feasible and efficient. Delaying such a reconstruction in younger children does not seem justified


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 569 - 569
1 Oct 2010
Bartl C Eichhorn S Holzapfel K Imhoff A Salzmann G Senftl M Seppel G Wörtler K
Full Access

In this retrospective study postoperative subscapularis (SSC) function was measured with an electronic force measurement plate (FMP) and clinical scores and correlated with SSC-muscle cross sectional area on defined MRI-sequences. 82 patients with subscapularis tears (34 isolated SSC tears and 48 combined SSC/SSP tears) were followed up at a mean of 38 (24–72) months after tendon reconstruction with the Constant score (CS) and clinical SSC-tests (Napoleon test, Lift off test). SSC-muscle function was assessed in the belly-press- and the lift off position using a custom made electronic FMP (force in Newton). SSC muscle strength values were compared with the contra-lateral side. SSC-muscle atrophy (muscle cross sectional area in mm. 2. ) was measured on standardised sagittal MRI-planes and compared with a healthy matched control group (CG) (Mann-Whitney-U-Test). The mean CS improved from 51p to 81p in isolated tears (group 1) and from an average 47 p to 78 p in combined tears (group 2) (each p< 0.01). Overall 85% of the patients rated their result as good or excellent. Positive and intermediate postop. Napoleon tests were still present in 30% in group 1 and in 25% in group 2. Mean postoperative SSC-muscle strength in the belly-press position averaged 64 N (contralatera sidel-CL: 86 N) in group 1 and 81 N (CL: 91 N) in group 2. Lift-off test strength averaged 36 N (CL: 69 N) in group 1 and 50 N (CL: 63 N) in group 2 (each p< 0.05). Postoperative MRI revealed a significant reduced SSC muscle cross sectional area for the operated side compared with the CG (group 1: SSC: 1974 mm. 2. ; CG 2980 mm. 2. p< 0,05; group 2: SSC: 1829 mm. 2. ; CG 2406 mm. 2. − SSP: 570 mm. 2. ; CG 812 mm. 2. each p< 0,05). Despite good clinical results after reconstruction of isolated and combined subscapularis tears a marked subscapularis strength deficit remains that is not reflected in the Constant Score, but can be detected with the new measurement device. Additionally a subscapularis muscle atrophy remains in the postoperative course that cannot be reversed by surgery


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 169 - 169
1 May 2011
Cheung G Miller D Wilson L Meyer C Kerin C Ford D
Full Access

The treatment of unstable distal radius fractures remains controversial. Volar locking plates provide stable fixation using the fixed angle device principle. More recently this technique has gained increasing popularity with several reports demonstrating good results. We present our experience from the first 259 patients performed at this institution. Method: Local Ethics Committee approval was obtained prior to the onset of the study. Theatre records and implant forms were used to recruit all patients in whom a Distal Volar Radius (DVR) Plate, (DePuy, Leeds, United Kingdom) was used for an unstable distal radius fracture between August 2005 and February 2008. Surgery was performed either by a consultant, or a specialist registrar. Two hundred and fifty nine consecutive patients were identified. Six patients had bilateral distal radius fractures. Patient records were reviewed, and each patient contacted via a postal questionnaire and Patient-Rated Wrist Evaluation (PRWE). Other outcome measures included return to work and complication rate. Results: Of the 259 patients 160 responses were received, response rate 62%. The mean follow up was 30.8 months, (Range 18–48). The mean age of the patients was 57.3 years (Range 16–93). The mean inpatient stay was 1.6 days, (mode 1 day). The median PRWE was 3; (range 0–83) and the mode was 0. Ninety four of the patients had a PRWE of ≤5. Seventy one out of 78 patients (91%) returned to the same job. The mean return to work was 40.6 days (SD37.5). There were 13 minor complications in total (7.8%). Six patients had extensor tendon irritation, of which two patients required extensor tendon reconstruction. One further patient had a spontaneous EPL rupture which was not associated with prominent metal work. Four (2.4%) patients had median nerve symptoms postoperatively. Two patients subsequently required carpal tunnel decompression, the other two settled spontaneously. Two (1.2%), patients developed Complex Regional Pain Syndrome. One patient developed a minor superficial wound infection. In all, 9 (5.4%) patients had removal of their metalwork, 6 for tendon irritation, 2 for wrist stiffness (one which was positioned too distally) and 1 for pin penetration into the joint. Discussion: Our results show that the DVR plate can be used reliably with good results and an early return to high levels of function. This is the largest series to date of the use of this distal volar locking plate


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 370 - 370
1 Oct 2006
Smith T Goodship A Birch H
Full Access

Introduction: Different tendons and ligaments have a specific elasticity which relates to their role in joint movement and locomotion. To ensure an optimal functional outcome it is essential that this mechanical property is restored following surgical procedures to repair or replace damaged tendons and ligaments. This demands appropriate selection of an autograft or artificial construct aided by an understanding of how molecular composition and morphology determines the stiffness of the material. This study tests the hypothesis that tendons with a higher elastic modulus (stiffer) have larger collagen fibril diameters and lower water and sulphated glycosaminoglycan (GAG) contents. Methods: The superficial digital flexor tendon (SDFT, 30 pairs), deep digital flexor tendon (DDFT, 6 pairs), suspensory ligament (SL, 6 pairs) and common digital extensor tendon (CDET, 6 pairs) were collected from the forelimbs of horses aged 2–23 years destroyed for reasons other than tendon injuries. Left limb tendons were tested to failure in a hydraulic materials testing machine (Dartec) following measurement of cross sectional area. Collagen fibril diameters, water content and sulphated GAG content were measured in tendon tissue from the right limb. Statistical significance was evaluated using Spearman’s correlation and a general linear model (SPSS software). Results: The elastic modulus was significantly (p< 0.001) different between the different structures and showed a significant positive correlation with the mass average collagen fibril diameter (MAFD) for the different structures and within the SDFT (FIG. I). The water content showed a significant negative correlation with elastic modulus and significant positive correlation with GAG content. Discussion and Conclusion: Tendons composed of a stiffer material have larger collagen fibril diameters which are associated with lower water and GAG contents. These characteristics should be considered when choosing suitable replacements in tendon reconstruction procedures. Future work to determine the mechanisms that control collagen fibril diameters and water content will aid in the design of bioengineered constructs


Bone & Joint Open
Vol. 2, Issue 2 | Pages 134 - 140
24 Feb 2021
Logishetty K Edwards TC Subbiah Ponniah H Ahmed M Liddle AD Cobb J Clark C

Aims

Restarting planned surgery during the COVID-19 pandemic is a clinical and societal priority, but it is unknown whether it can be done safely and include high-risk or complex cases. We developed a Surgical Prioritization and Allocation Guide (SPAG). Here, we validate its effectiveness and safety in COVID-free sites.

Methods

A multidisciplinary surgical prioritization committee developed the SPAG, incorporating procedural urgency, shared decision-making, patient safety, and biopsychosocial factors; and applied it to 1,142 adult patients awaiting orthopaedic surgery. Patients were stratified into four priority groups and underwent surgery at three COVID-free sites, including one with access to a high dependency unit (HDU) or intensive care unit (ICU) and specialist resources. Safety was assessed by the number of patients requiring inpatient postoperative HDU/ICU admission, contracting COVID-19 within 14 days postoperatively, and mortality within 30 days postoperatively.